Abstract: Nanofibers are defined as fibers with diameters less
than 100 nanometers. In this study, behaviours of activated carbon
nanofiber (ACNF), carbon nanofiber (CNF), polyacrylonitrile/ carbon
nanotube (PAN/CNT), polyvinyl alcohol/nanosilver (PVA/Ag) in
proton exchange membrane (PEM) fuel cells are investigated
experimentally. This material was used as gas diffusion layer (GDL)
in PEM fuel cells. In this study, the electrical conductivities of
nanofiber and nanofiber/nanoparticles have been studied to
understand their effects on PEM fuel cell performance. According to
the experimental results, the maximum electrical conductivity
performance of the fuel cell with nanofiber was found to be at
PVA/Ag (at UConn condition). The electrical conductivities of CNF,
ACNF, PAN/CNT are lower for PEM. The resistance of cell with
PVA/Ag is lower than the resistance of cell with PAN/CNT, ACNF,
CNF.
Abstract: Green and renewable energy is getting extraordinary
consideration today, because of ecological concerns made by blazing
of fossil powers. Photovoltaic and wind power generation are the
basic decisions for delivering power in this respects. Producing
power by the sun based photovoltaic systems is known to the world,
yet control makers may get confounded to pick between on-grid and
off-grid systems. In this exploration work, an endeavor is made to
compare the off-grid (stand-alone) and on-grid (grid-connected)
frameworks. The work presents relative examination, between two
distinctive PV frameworks situated at V.V.P. Engineering College,
Rajkot. The first framework is 100 kW remain solitary and the
second is 60 kW network joined. The real-time parameters compared
are; output voltage, load current, power in-flow, power output,
performance ratio, yield factor, and capacity factor. The voltage
changes and the power variances in both frameworks are given
exceptional consideration and the examination is made between the
two frameworks to judge the focal points and confinements of both
the frameworks.
Abstract: In the present study, feasibility of the selective surface
hydrophilization of polyvinyl chloride (PVC) by microwave treatment
was evaluated to facilitate the separation from automotive shredder
residue (ASR), by the froth flotation. The combination of 60 sec
microwave treatment with PAC, a sharp and significant decrease about
16.5° contact angle of PVC was observed in ASR plastic compared
with other plastics. The microwave treatment with the addition of PAC
resulted in a synergetic effect for the froth flotation, which may be a
result of the 90% selective separation of PVC from ASR plastics, with
82% purity. While, simple mixing with a nanometallic Ca/CaO/PO4
dispersion mixture immobilized 95-100% of heavy metals in ASR
soil/residues. The quantity of heavy metals leached from thermal
residues after treatment by nanometallic Ca/CaO/PO4 was lower than
the Korean standard regulatory limit for hazardous waste landfills.
Microwave treatment can be a simple and effective method for PVC
separation from ASR plastics.
Abstract: Direct Torque Control (DTC) is an AC drive control
method especially designed to provide fast and robust responses. In
this paper a progressive algorithm for direct torque control of threephase
induction drive system supplied by photovoltaic arrays using
voltage source inverter to control motor torque and flux with
maximum power point tracking at different level of insolation is
presented. Experimental results of the new DTC method obtained by
an experimental rapid prototype system for drives are presented.
Simulation and experimental results confirm that the proposed system
gives quick, robust torque and speed responses at constant switching
frequencies.
Abstract: A Multi-dimensional computational fluid dynamics
(CFD) two-phase model was developed with the aim to simulate
the in-core coolant circuit of a pressurized heavy water reactor
(PHWR) of a commercial nuclear power plant (NPP). Due to the
fact that this PHWR is a Reactor Pressure Vessel type (RPV),
three-dimensional (3D) detailed modelling of the large reservoirs of
the RPV (the upper and lower plenums and the downcomer) were
coupled with an in-house finite volume one-dimensional (1D) code
in order to model the 451 coolant channels housing the nuclear fuel.
Regarding the 1D code, suitable empirical correlations for taking into
account the in-channel distributed (friction losses) and concentrated
(spacer grids, inlet and outlet throttles) pressure losses were used.
A local power distribution at each one of the coolant channels
was also taken into account. The heat transfer between the coolant
and the surrounding moderator was accurately calculated using a
two-dimensional theoretical model. The implementation of subcooled
boiling and condensation models in the 1D code along with the use
of functions for representing the thermal and dynamic properties of
the coolant and moderator (heavy water) allow to have estimations
of the in-core steam generation under nominal flow conditions for a
generic fission power distribution. The in-core mass flow distribution
results for steady state nominal conditions are in agreement with the
expected from design, thus getting a first assessment of the coupled
1/3D model. Results for nominal condition were compared with
those obtained with a previous 1/3D single-phase model getting more
realistic temperature patterns, also allowing visualize low values of
void fraction inside the upper plenum. It must be mentioned that the
current results were obtained by imposing prescribed fission power
functions from literature. Therefore, results are showed with the aim
of point out the potentiality of the developed model.
Abstract: The use of solar energy as a source for pumping water
is one of the promising areas in the photovoltaic (PV) application.
The energy of photovoltaic pumping systems (PVPS) can be widely
improved by employing an MPPT algorithm. This will lead
consequently to maximize the electrical motor speed of the system.
This paper presents a modified incremental conductance (IncCond)
MPPT algorithm with direct control method applied to a standalone
PV pumping system. The influence of the algorithm parameters on
system behavior is investigated and compared with the traditional
(INC) method. The studied system consists of a PV panel, a DC-DC
boost converter, and a PMDC motor-pump. The simulation of the
system by MATLAB-SIMULINK is carried out. Simulation results
found are satisfactory.
Abstract: This paper presents a model predictive control (MPC)
of a utility interactive three phase inverter (TPI) for a photovoltaic
(PV) system at commercial level. The proposed model uses phase
locked loop (PLL) to synchronize the TPI with the power electric
grid (PEG) and performs MPC control in a dq reference frame. TPI
model consists of a boost converter (BC), maximum power point
tracking (MPPT) control, and a three-leg voltage source inverter
(VSI). The operational model of VSI is used to synthesize the
sinusoidal current and track the reference. The model is validated
using a 35.7 kW PV system in Matlab/Simulink. Implementation
results show simplicity and accuracy, as well as reliability of the
model.
Abstract: The present study deals with the characterization of
CrSiN coatings obtained by PVD magnetron sputtering systems.
CrSiN films were deposited with different Si contents, in order to
check the effect of at.% variation on the different properties of the
Cr–N system. Coatings were characterized by scanning electron
microscopy (SEM) for thickness measurements, X-ray diffraction.
Surface morphology and the roughness characteristics were explored
using AFM, Mechanicals properties, elastic and plastic deformation
resistance of thin films were investigated using nanoindentation test. We observed that the Si addition improved the hardness and the
Young’s modulus of the Cr–N system. Indeed, the hardness value is
18,56 GPa for CrSiN coatings. Besides, the Young’s modulus value
is 224,22 GPa for CrSiN coatings for Si content of 1.2 at.%.
Abstract: The photovoltaic (PV) panel with no galvanic
isolation system is well known technique in the world which is
effective and delivers power with enhanced efficiency. The PV
generation presented here is for stand-alone system installed in
remote areas when as the resulting power gets connected to electronic
load installation instead of being tied to the grid. Though very small,
even then transformer-less topology is shown to be with leakage in
pico-ampere range. By using PWM technique PWM, leakage current
in different situations is shown. The results shown in this paper show
how the pico-ampere current is reduced to femto-ampere through use
of inductors and capacitors of suitable values of inductor and
capacitors with the load.
Abstract: This paper presents comparative analysis of
photovoltaic systems (PVS) and propose practical techniques to
improve operational efficiency of the PVS. The best engineering and
construction practices for PVS are identified and field oriented
recommendation are made. Comparative analysis of central and
string inverter based, as well as 600 and 1000VDC PVS are
performed. In addition, direct current (DC) and alternating current
(AC) photovoltaic (PV) module based systems are compared.
Comparison shows that 1000V DC String Inverters based PVS is the
best choice.
Abstract: Temperature effect on the performance of a photovoltaic module is one of the main concerns that face this renewable energy, especially in hot arid region, e.g. United Arab Emirates. Overheating of the PV modules reduces the open circuit voltage and the efficiency of the modules dramatically. In this work, water-cooling is developed to enhance the performance of PV modules. Different scenarios are tested under UAE weather conditions: front, back and double cooling. A spraying system is used for the front cooling whether a direct contact water system is used for the back cooling. The experimental results are compared to non-cooling module and the performance of the PV module is determined for different situations. The experimental results show that the front cooling is more effective than the back cooling and may decrease the temperature of the PV module significantly.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: In most existing buildings in hot climate, cooling
loads lead to high primary energy consumption and consequently
high CO2 emissions. These can be substantially decreased with
integrated renewable energy systems. Kuwait is characterized by its
dry hot long summer and short warm winter. Kuwait receives annual
total radiation more than 5280 MJ/m2 with approximately 3347 h of
sunshine. Solar energy systems consist of PV modules and parabolic
trough collectors are considered to satisfy electricity consumption,
domestic water heating, and cooling loads of an existing building.
This paper presents the results of an extensive program of energy
conservation and energy generation using integrated photovoltaic
(PV) modules and Parabolic Trough Collectors (PTC). The program
conducted on an existing institutional building intending to convert it
into a Net-Zero Energy Building (NZEB) or near net Zero Energy
Building (nNZEB). The program consists of two phases; the first
phase is concerned with energy auditing and energy conservation
measures at minimum cost and the second phase considers the
installation of photovoltaic modules and parabolic trough collectors.
The 2-storey building under consideration is the Applied Sciences
Department at the College of Technological Studies, Kuwait. Single
effect lithium bromide water absorption chillers are implemented to
provide air conditioning load to the building. A numerical model is
developed to evaluate the performance of parabolic trough collectors
in Kuwait climate. Transient simulation program (TRNSYS) is
adapted to simulate the performance of different solar system
components. In addition, a numerical model is developed to assess
the environmental impacts of building integrated renewable energy
systems. Results indicate that efficient energy conservation can play
an important role in converting the existing buildings into NZEBs as
it saves a significant portion of annual energy consumption of the
building. The first phase results in an energy conservation of about
28% of the building consumption. In the second phase, the integrated
PV completely covers the lighting and equipment loads of the
building. On the other hand, parabolic trough collectors of optimum
area of 765 m2 can satisfy a significant portion of the cooling load,
i.e about73% of the total building cooling load. The annual avoided
CO2 emission is evaluated at the optimum conditions to assess the
environmental impacts of renewable energy systems. The total annual
avoided CO2 emission is about 680 metric ton/year which confirms
the environmental impacts of these systems in Kuwait.
Abstract: Graphene was dispersed using a tip sonicator and the
effect of surfactants were analysed. Sodium Dodecyl Sulphate (SDS)
and Polyvinyl Alcohol (PVA) were compared to observe whether or
not they had any effect on any de-wrinkling, and secondly whether
they aided to achieve better dispersions. There is a huge demand for
wrinkle free graphene as this will greatly increase its usefulness in
various engineering applications. A comprehensive literature on dewrinkling
graphene has been discussed. Low magnification Scanning
Electronic Microscopy (SEM) was conducted to assess the quality of
graphene de-wrinkling. The utilization of the PVA has significant
effect on de-wrinkling whereas SDS had minimal effect on the dewrinkling
of graphene.
Abstract: Concrete is strong in compression however weak in
tension. The tensile strength as well as ductile property of concrete
could be improved by addition of short dispersed fibers. Polyethylene
terephthalate (PET) fiber obtained from hand cutting or mechanical
slitting of plastic sheets generally used as discrete reinforcement in
substitution of steel fiber. PET fiber obtained from the former process
is in the form of straight slit sheet pattern that impart weaker
mechanical bonding behavior in the concrete matrix. To improve the
limitation of straight slit sheet fiber the present study considered two
additional geometry of fiber namely (a) flattened end slit sheet and
(b) deformed slit sheet. The mix for plain concrete was design for a
compressive strength of 25 MPa at 28 days curing time with a watercement
ratio of 0.5. Cylindrical and beam specimens with 0.5% fibers
volume fraction and without fibers were cast to investigate the
influence of geometry on the mechanical properties of concrete. The
performance parameters mainly studied include flexural strength,
splitting tensile strength, compressive strength and ultrasonic pulse
velocity (UPV). Test results show that geometry of fiber has a
marginal effect on the workability of concrete. However, it plays a
significant role in achieving a good compressive and tensile strength
of concrete. Further, significant improvement in term of flexural and
energy dissipation capacity were observed from other fibers as
compared to the straight slit sheet pattern. Also, the inclusion of PET
fiber improved the ability in absorbing energy in the post-cracking
state of the specimen as well as no significant porous structures.
Abstract: Photovoltaic (PV) power generation systems, mainly
small scale, are rapidly being deployed in Jordan. The impact of these
systems on the grid has not been studied or analyzed. These systems
can cause many technical problems such as reverse power flows and
voltage rises in distribution feeders, and real and reactive power
transients that affect the operation of the transmission system. To
fully understand and address these problems, extensive research,
simulation, and case studies are required. To this end, this paper
studies the cloud shadow effect on the power generation of a ground
mounted PV system installed at the test field of the Renewable
Energy Center at the Applied Science University.
Abstract: These Monolayer and multilayer coatings of CrN and
AlCrN deposited on 100Cr6 (AISI 52100) substrate by PVD
magnetron sputtering system. The microstructures of the coatings
were characterized using atomic force microscopy (AFM). The AFM
analysis revealed the presence of domes and craters that are
uniformly distributed over all surfaces of the various layers.
Nanoindentation measurement of CrN coating showed maximum
hardness (H) and modulus (E) of 14 GPa and 190 GPa, respectively.
The measured H and E values of AlCrN coatings were found to be 30
GPa and 382 GPa, respectively. The improved hardness in both the
coatings was attributed mainly to a reduction in crystallite size and
decrease in surface roughness. The incorporation of Al into the CrN
coatings has improved both hardness and Young’s modulus.
Abstract: In this study, to clarify the effectiveness of an
aluminum/chromium/tungsten-based-coated tool for cutting sintered
steel, tool wear was experimentally investigated. The sintered steel
was turned with the (Al60,Cr25,W15)N-, (Al60,Cr25,W15)(C,N)- and
(Al64,Cr28,W8)(C,N)-coated cemented carbide tools according to the
physical vapor deposition (PVD) method. Moreover, the tool wear of
the aluminum/chromium/tungsten-based-coated item was compared
with that of the (Al,Cr)N coated tool. Furthermore, to clarify the tool
wear mechanism of the aluminum/chromium/tungsten-coating film for
cutting sintered steel, Scanning Electron Microscope observation and
Energy Dispersive x-ray Spectroscopy mapping analysis were
conducted on the abraded surface. The following results were
obtained: (1) The wear progress of the (Al64,Cr28,W8)(C,N)-coated
tool was the slowest among that of the five coated tools. (2) Adding
carbon (C) to the aluminum/chromium/tungsten-based-coating film
was effective for improving the wear-resistance. (3) The main wear
mechanism of the (Al60,Cr25,W15)N-, the (Al60,Cr25,W15)(C,N)-
and the (Al64,Cr28,W8)(C,N)-coating films was abrasive wear.
Abstract: In recent years a new method of combination
treatment for cancer has been developed and studied that has led to
significant advancements in the field of cancer therapy. Hyperthermia
is a traditional therapy that, along with a creation of a medically
approved level of heat with the help of an alternating magnetic AC
current, results in the destruction of cancer cells by heat. This paper
gives details regarding the production of the spherical nanocomposite
PVA/γ-Fe2O3 in order to be used for medical purposes such as tumor
treatment by hyperthermia. To reach a suitable and evenly distributed
temperature, the nanocomposite with core-shell morphology and
spherical form within a 100 to 200 nanometer size was created using
phase separation emulsion, in which the magnetic nano-particles γ-
Fe2O3 with an average particle size of 20 nano-meters and with
different percentages of 0.2, 0.4, 0.5 and 0.6 were covered by
polyvinyl alcohol. The main concern in hyperthermia and heat
treatment is achieving desirable specific absorption rate (SAR) and
one of the most critical factors in SAR is particle size. In this project
all attempts has been done to reach minimal size and consequently
maximum SAR. The morphological analysis of the spherical
structure of the nanocomposite PVA/γ-Fe2O3 was achieved by SEM
analyses and the study of the chemical bonds created was made
possible by FTIR analysis. To investigate the manner of magnetic
nanocomposite particle size distribution a DLS experiment was
conducted. Moreover, to determine the magnetic behavior of the γ-
Fe2O3 particle and the nanocomposite PVA/γ-Fe2O3 in different
concentrations a VSM test was conducted. To sum up, creating
magnetic nanocomposites with a spherical morphology that would be
employed for drug loading opens doors to new approaches in
developing nanocomposites that provide efficient heat and a
controlled release of drug simultaneously inside the magnetic field,
which are among their positive characteristics that could significantly
improve the recovery process in patients.
Abstract: It is the worldwide problem that the recycled PVB is
not recycled and it is wildly stored in landfills. However, PVB has
similar chemical properties such as PVC. Moreover, both of these
polymers are plasticized. Therefore, the study of thermal properties
of plasticized PVC and the recycled PVB obtained by recycling of
windshields is carried out. This work has done in order to find nondegradable
processing conditions applicable for both polymers.
Tested PVC contained 38% of plasticizer diisononyl phthalate
(DINP) and PVB was plasticized with 28% of triethylene glycol,
bis(2-ethylhexanoate) (3GO). The thermal and thermo-oxidative
decomposition of both vinyl polymers are compared by calorimetric
analysis and by tensile strength analysis.