Abstract: Design of a fixed parameter robust STATCOM controller for a multi-machine power system through an H-? based loop-shaping procedure is presented. The trial and error part of the graphical loop-shaping procedure has been eliminated by embedding a particle swarm optimization (PSO) technique in the design loop. Robust controllers were designed considering the detailed dynamics of the multi-machine system and results were compared with reduced order models. The robust strategy employing loop-shaping and PSO algorithms was observed to provide very good damping profile for a wide range of operation and for various disturbance conditions.
Abstract: Droughts are complex, natural hazards that, to a
varying degree, affect some parts of the world every year. The range
of drought impacts is related to drought occurring in different stages
of the hydrological cycle and usually different types of droughts,
such as meteorological, agricultural, hydrological, and socioeconomical
are distinguished. Streamflow drought was analyzed by
the method of truncation level (at 70% level) on daily discharges
measured in 54 hydrometric stations in southwestern Iran. Frequency
analysis was carried out for annual maximum series (AMS) of
drought deficit volume and duration series. Some factors including
physiographic, climatic, geologic, and vegetation cover were studied
as influential factors in the regional analysis. According to the results
of factor analysis, six most effective factors were identified as area,
rainfall from December to February, the percent of area with
Normalized Difference Vegetation Index (NDVI)
Abstract: The energy consumption of home femto base stations
(BSs) can be reduced, by turning off the Wi-Fi radio interface when
there is no mobile station (MS) under the coverage of the BSs or
MSs do not transmit or receive data packet for long time, especially
in late night. In the energy-efficient home femto BSs, if MSs have
any data packet to transmit and the Wi-Fi radio interface in off
state, MSs wake up the Wi-Fi radio interface of home femto BSs
by using additional low power radio interface. In this paper, the
performance of the energy-efficient home femto BSs from the aspect
of energy consumption and cumulative average delay, and show the
effect of various parameters on energy consumption and cumulative
average delay. From the results, the tradeoff relationship between
energy consumption and cumulative average delay is shown and thus,
appropriate operation should be needed to balance the tradeoff.
Abstract: Load forecasting has always been the essential part of
an efficient power system operation and planning. A novel approach
based on support vector machines is proposed in this paper for annual
power load forecasting. Different kernel functions are selected to
construct a combinatorial algorithm. The performance of the new
model is evaluated with a real-world dataset, and compared with two
neural networks and some traditional forecasting techniques. The
results show that the proposed method exhibits superior performance.
Abstract: In this paper, we consider the problem of logic simplification for a special class of logic functions, namely complementary Boolean functions (CBF), targeting low power implementation using static CMOS logic style. The functions are uniquely characterized by the presence of terms, where for a canonical binary 2-tuple, D(mj) ∪ D(mk) = { } and therefore, we have | D(mj) ∪ D(mk) | = 0 [19]. Similarly, D(Mj) ∪ D(Mk) = { } and hence | D(Mj) ∪ D(Mk) | = 0. Here, 'mk' and 'Mk' represent a minterm and maxterm respectively. We compare the circuits minimized with our proposed method with those corresponding to factored Reed-Muller (f-RM) form, factored Pseudo Kronecker Reed-Muller (f-PKRM) form, and factored Generalized Reed-Muller (f-GRM) form. We have opted for algebraic factorization of the Reed-Muller (RM) form and its different variants, using the factorization rules of [1], as it is simple and requires much less CPU execution time compared to Boolean factorization operations. This technique has enabled us to greatly reduce the literal count as well as the gate count needed for such RM realizations, which are generally prone to consuming more cells and subsequently more power consumption. However, this leads to a drawback in terms of the design-for-test attribute associated with the various RM forms. Though we still preserve the definition of those forms viz. realizing such functionality with only select types of logic gates (AND gate and XOR gate), the structural integrity of the logic levels is not preserved. This would consequently alter the testability properties of such circuits i.e. it may increase/decrease/maintain the same number of test input vectors needed for their exhaustive testability, subsequently affecting their generalized test vector computation. We do not consider the issue of design-for-testability here, but, instead focus on the power consumption of the final logic implementation, after realization with a conventional CMOS process technology (0.35 micron TSMC process). The quality of the resulting circuits evaluated on the basis of an established cost metric viz., power consumption, demonstrate average savings by 26.79% for the samples considered in this work, besides reduction in number of gates and input literals by 39.66% and 12.98% respectively, in comparison with other factored RM forms.
Abstract: This paper presents application artificial intelligent (AI) techniques, namely artificial neural network (ANN), adaptive neuro fuzzy interface system (ANFIS), to estimate the real power transfer between generators and loads. Since these AI techniques adopt supervised learning, it first uses modified nodal equation method (MNE) to determine real power contribution from each generator to loads. Then the results of MNE method and load flow information are utilized to estimate the power transfer using AI techniques. The 25-bus equivalent system of south Malaysia is utilized as a test system to illustrate the effectiveness of both AI methods compared to that of the MNE method. The mean squared error of the estimate of ANN and ANFIS power transfer allocation methods are 1.19E-05 and 2.97E-05, respectively. Furthermore, when compared to MNE method, ANN and ANFIS methods computes generator contribution to loads within 20.99 and 39.37msec respectively whereas the MNE method took 360msec for the calculation of same real power transfer allocation.
Abstract: This paper is a continuation of our daily energy peak load forecasting approach using our modified network which is part of the recurrent networks family and is called feed forward and feed back multi context artificial neural network (FFFB-MCANN). The inputs to the network were exogenous variables such as the previous and current change in the weather components, the previous and current status of the day and endogenous variables such as the past change in the loads. Endogenous variable such as the current change in the loads were used on the network output. Experiment shows that using endogenous and exogenous variables as inputs to the FFFBMCANN rather than either exogenous or endogenous variables as inputs to the same network produces better results. Experiments show that using the change in variables such as weather components and the change in the past load as inputs to the FFFB-MCANN rather than the absolute values for the weather components and past load as inputs to the same network has a dramatic impact and produce better accuracy.
Abstract: Computerized alarm systems have been applied
increasingly to nuclear power plants. For existing plants, an add-on
computer alarm system is often installed to the control rooms. Alarm
avalanches during the plant transients are major problems with the
alarm systems in nuclear power plants. Computerized alarm systems
can process alarms to reduce the number of alarms during the plant
transients. This paper describes various alarm processing methods, an
alarm cause tracking function, and various alarm presentation schemes
to show alarm information to the operators effectively which are
considered during the development of several computerized alarm
systems for Korean nuclear power plants and are found to be helpful to
the operators.
Abstract: Due to the deregulation of the Electric Supply
Industry and the resulting emergence of electricity market, the
volumes of power purchases are on the rise all over the world. In a
bid to meet the customer-s demand in a reliable and yet economic
manner, utilities purchase power from the energy market over and
above its own production. This paper aims at developing an optimal
power purchase model with two objectives viz economy and
environment ,taking various functional operating constraints such as
branch flow limits, load bus voltage magnitudes limits, unit capacity
constraints and security constraints into consideration.The price of
purchased power being an uncertain variable is modeled using fuzzy
logic. DEMO (Differential Evolution For Multi-objective
Optimization) is used to obtain the pareto-optimal solution set of the
multi-objective problem formulated. Fuzzy set theory has been
employed to extract the best compromise non-dominated solution.
The results obtained on IEEE 30 bus system are presented and
compared with that of NSGAII.
Abstract: The paper deals with the comparison study of
harmonic detection methods for a shunt active power filter. The
%THD and the power factor value at the PCC point after
compensation are considered for the comparison. There are three
harmonic detection methods used in the paper that are synchronous
reference frame method, synchronous detection method, and DQ axis
with Fourier method. In addition, the ideal current source is used to
represent the active power filter by assuming an infinitely fast
controller action of the active power filter. The simulation results
show that the DQ axis with Fourier method provides the minimum
%THD after compensation compared with other methods. However,
the power factor value at the PCC point after compensation is slightly
lower than that of synchronous detection method.
Abstract: This paper presents a systematic procedure for modelling and simulation of a power system installed with a power system stabilizer (PSS) and a flexible ac transmission system (FACTS)-based controller. For the design purpose, the model of example power system which is a single-machine infinite-bus power system installed with the proposed controllers is developed in MATLAB/SIMULINK. In the developed model synchronous generator is represented by model 1.1. which includes both the generator main field winding and the damper winding in q-axis so as to evaluate the impact of PSS and FACTS-based controller on power system stability. The model can be can be used for teaching the power system stability phenomena, and also for research works especially to develop generator controllers using advanced technologies. Further, to avoid adverse interactions, PSS and FACTS-based controller are simultaneously designed employing genetic algorithm (GA). The non-linear simulation results are presented for the example power system under various disturbance conditions to validate the effectiveness of the proposed modelling and simultaneous design approach.
Abstract: Regenerative Thermal Oxidizer (RTO) is one of the
best solutions for removal of Volatile Organic Compounds (VOC)
from industrial processes. In the RTO, VOC in a raw gas are usually
decomposed at 950-1300 K and the combustion heat of VOC is
recovered by regenerative heat exchangers charged with ceramic
honeycombs. The optimization of the treatment of VOC leads to the
reduction of fuel addition to VOC decomposition, the minimization of
CO2 emission and operating cost as well.
In the present work, the thermal efficiency of the RTO was
investigated experimentally in a pilot-scale RTO unit using toluene as
a typical representative of VOC. As a result, it was recognized that the
radiative heat transfer was dominant in the preheating process of a raw
gas when the gas flow rate was relatively low. Further, it was found
that a minimum heat exchanger volume to achieve self combustion of
toluene without additional heating of the RTO by fuel combustion was
dependent on both the flow rate of a raw gas and the concentration of
toluene. The thermal efficiency calculated from fuel consumption and
the decomposed toluene ratio, was found to have a maximum value of
0.95 at a raw gas mass flow rate of 1810 kg·h-1 and honeycombs height
of 1.5m.
Abstract: This paper deals with a novel approach of power
transformers diagnostics. This approach identifies the exact location
and the range of a fault in the transformer and helps to reduce
operation costs related to handling of the faulty transformer, its
disassembly and repair. The advantage of the approach is a
possibility to simulate healthy transformer and also all faults, which
can occur in transformer during its operation without its
disassembling, which is very expensive in practice. The approach is
based on creating frequency dependent impedance of the transformer
by sweep frequency response analysis measurements and by 3D FE
parametrical modeling of the fault in the transformer. The parameters
of the 3D FE model are the position and the range of the axial short
circuit. Then, by comparing the frequency dependent impedances of
the parametrical models with the measured ones, the location and the
range of the fault is identified. The approach was tested on a real
transformer and showed high coincidence between the real fault and
the simulated one.
Abstract: This paper considers the influence of promotion
instruments for renewable energy sources (RES) on a multi-energy
modeling framework. In Europe, so called Feed-in Tariffs are
successfully used as incentive structures to increase the amount of
energy produced by RES. Because of the stochastic nature of large
scale integration of distributed generation, many problems have
occurred regarding the quality and stability of supply. Hence, a
macroscopic model was developed in order to optimize the power
supply of the local energy infrastructure, which includes electricity,
natural gas, fuel oil and district heating as energy carriers. Unique
features of the model are the integration of RES and the adoption of
Feed-in Tariffs into one optimization stage. Sensitivity studies are
carried out to examine the system behavior under changing profits
for the feed-in of RES. With a setup of three energy exchanging
regions and a multi-period optimization, the impact of costs and
profits are determined.
Abstract: This paper focuses on PSS/E modeling of wind farms
of Doubly-fed Induction Generator (DFIG) type and their impact on
issues of power system operation. Since Wind Turbine Generators
(WTG) don-t have the same characteristics as synchronous
generators, the appropriate modeling of wind farms is essential for
transmission system operators to analyze the best options of
transmission grid reinforcements as well as to evaluate the wind
power impact on reliability and security of supply. With the high
excepted penetration of wind power into the power system a
simultaneous loss of Wind Farm generation will put at risk power
system security and reliability. Therefore, the main wind grid code
requirements concern the fault ride through capability and frequency
operation range of wind turbines. In case of grid faults wind turbines
have to supply a definite reactive power depending on the
instantaneous voltage and to return quickly to normal operation.
Abstract: In this paper a new approach for transmission pricing
is presented. The main idea is voltage angle allocation, i.e.
determining the contribution of each contract on the voltage angle of
each bus. DC power flow is used to compute a primary solution for
angle decomposition. To consider the impacts of system non-linearity
on angle decomposition, the primary solution is corrected in different
iterations of decoupled Newton-Raphson power flow. Then, the
contribution of each contract on power flow of each transmission line
is computed based on angle decomposition. Contract-related flows
are used as a measure for “extent of use" of transmission network
capacity and consequently transmission pricing. The presented
approach is applied to a 4-bus test system and IEEE 30-bus test
system.
Abstract: This paper presents a methodology towards the emulation of the electrical power consumption of the RF device during the cellular phone/handset transmission mode using the LTE technology. The emulation methodology takes the physical environmental variables and the logical interface between the baseband and the RF system as inputs to compute the emulated power dissipation of the RF device. The emulated power, in between the measured points corresponding to the discrete values of the logical interface parameters is computed as a polynomial interpolation using polynomial basis functions. The evaluation of polynomial and spline curve fitting models showed a respective divergence (test error) of 8% and 0.02% from the physically measured power consumption. The precisions of the instruments used for the physical measurements have been modeled as intervals. We have been able to model the power consumption of the RF device operating at 5MHz using homotopy between 2 continuous power consumptions of the RF device operating at the bandwidths 3MHz and 10MHz.
Abstract: The power consumption of an Optical Packet Switch
equipped with SOA technology based Spanke switching fabric is
evaluated. Sophisticated analytical models are introduced to evaluate
the power consumption versus the offered traffic, the main
switch parameters, and the used device characteristics. The impact
of Amplifier Spontaneous Emission (ASE) noise generated by a
transmission system on the power consumption is investigated. As
a matter of example for 32×32 switches supporting 64 wavelengths
and offered traffic equal to 0,8, the average energy consumption per
bit is 5, 07 · 10-2 nJ/bit and increases if ASE noise introduced by
the transmission systems is increased.
Abstract: This research deals with techno economic analysis to select the most economic desalination method for Asalouyeh combined cycle power plant . Due to lack of fresh water, desalination of sea water is necessary to provide required DM water of Power Plant. The most common desalination methods are RO, MSF, MED, and MED–TVC. In this research, methods of RO, MED, and MED– TVC have been compared. Simulation results show that recovery of heat of exhaust gas of main stack is optimum case for providing DM water required for injected steam of MED desalination. This subject is very important because of improving thermal efficiency of power plant using extra heat recovery. Also, it has been shown that by adding 3 rows of finned tube to de-aerator evaporator, which is very simple and low cost, required steam for generating 5200 m3/day of desalinated water is obtainable.
Abstract: This study presents a new approach based on Tanaka's
fuzzy linear regression (FLP) algorithm to solve well-known power
system economic load dispatch problem (ELD). Tanaka's fuzzy linear
regression (FLP) formulation will be employed to compute the
optimal solution of optimization problem after linearization. The
unknowns are expressed as fuzzy numbers with a triangular
membership function that has middle and spread value reflected on
the unknowns. The proposed fuzzy model is formulated as a linear
optimization problem, where the objective is to minimize the sum of
the spread of the unknowns, subject to double inequality constraints.
Linear programming technique is employed to obtain the middle and
the symmetric spread for every unknown (power generation level).
Simulation results of the proposed approach will be compared with
those reported in literature.