Abstract: This paper presents congestion management in deregulated power systems. In a deregulated environment, every buyer wants to buy power from the cheapest generator available, irrespective of relative geographical location of buyer and seller. As a consequence of this, the transmission corridors evacuating the power of cheaper generators would get overloaded if all such transactions are approved. Congestion management is a mechanism to prioritize the transactions and commit to such a schedule which would not overload the network. The congestions in the transmission lines are determined by Optimal Power Flow (OPF) solution, which is carried by primal liner programming method. Congestion in the transmission lines are alleviated by connected Distributed Generation (DG) of micro grid at load bus. A method to determine the optimal location of DG unit has been suggested based on transmission line relief sensitivity based approach. The effectiveness of proposed method has been demonstrated on modified IEEE-14 and 30 bus test systems.
Abstract: Various studies have showed that about 90% of single line to ground faults occurred on High voltage transmission lines have transient nature. This type of faults is cleared by temporary outage (by the single phase auto-reclosure). The interval between opening and reclosing of the faulted phase circuit breakers is named “Dead Time” that is varying about several hundred milliseconds. For adjustment of traditional single phase auto-reclosures that usually are not intelligent, it is necessary to calculate the dead time in the off-line condition precisely. If the dead time used in adjustment of single phase auto-reclosure is less than the real dead time, the reclosing of circuit breakers threats the power systems seriously. So in this paper a novel approach for precise calculation of dead time in power transmission lines based on the network equivalencing in time domain is presented. This approach has extremely higher precision in comparison with the traditional method based on Thevenin equivalent circuit. For comparison between the proposed approach in this paper and the traditional method, a comprehensive simulation by EMTP-ATP is performed on an extensive power network.
Abstract: This paper proposes a mathematical model for transmission expansion employing optimization method with scenario analysis approach. Economic transmission planning, on the other hand, seeks investment opportunities so that network expansions can generate more economic benefits than the costs. This approach can be used as a decision model for building new transmission lines added to the existing transmission system minimizing costs of the entire system subject to various system’s constraints and consider of loss value of transmission system and N-1 checking. The results show that the proposed model is efficient to be applied for the larger scale of power system topology.
Abstract: According to the increasing utilization in power system, the transmission lines and power plants often operate in stability boundary and system probably lose its stable condition by over loading or occurring disturbance. According to the reasons that are mentioned, the prediction and recognition of voltage instability in power system has particular importance and it makes the network security stronger.This paper, by considering of power system contingencies based on the effects of them on Mega Watt Margin (MWM) and maximum loading point is focused in order to analyse the static voltage stability using continuation power flow method. The study has been carried out on IEEE 14-Bus Test System using Matlab and Psat softwares and results are presented.
Abstract: This paper presents a wavelet transform and Support
Vector Machine (SVM) based algorithm for estimating fault location
on transmission lines. The Discrete wavelet transform (DWT) is used
for data pre-processing and this data are used for training and testing
SVM. Five types of mother wavelet are used for signal processing to
identify a suitable wavelet family that is more appropriate for use in
estimating fault location. The results demonstrated the ability of SVM
to generalize the situation from the provided patterns and to
accurately estimate the location of faults with varying fault resistance.
Abstract: The protection of parallel transmission lines has been a challenging task due to mutual coupling between the adjacent circuits of the line. This paper presents a novel scheme for detection and classification of faults on parallel transmission lines. The proposed approach uses combination of wavelet transform and neural network, to solve the problem. While wavelet transform is a powerful mathematical tool which can be employed as a fast and very effective means of analyzing power system transient signals, artificial neural network has a ability to classify non-linear relationship between measured signals by identifying different patterns of the associated signals. The proposed algorithm consists of time-frequency analysis of fault generated transients using wavelet transform, followed by pattern recognition using artificial neural network to identify the type of the fault. MATLAB/Simulink is used to generate fault signals and verify the correctness of the algorithm. The adaptive discrimination scheme is tested by simulating different types of fault and varying fault resistance, fault location and fault inception time, on a given power system model. The simulation results show that the proposed scheme for fault diagnosis is able to classify all the faults on the parallel transmission line rapidly and correctly.
Abstract: A novel and efficient approach to realize
fractional-order capacitors is investigated in this paper. Meanwhile, a
new approach which is more efficient for semiconductor
implementation of fractional-order capacitors is proposed. The
feasibility of the approach has been verified with the preliminary
measured results.
Abstract: The line sleeves on power transmission line connects
two conductors while the transmission line is constructing. However,
the line sleeves sometimes cause transmission line break down,
because the line sleeves are deteriorated and decayed by acid rain.
When the transmission line is broken, the economical loss is huge.
Therefore the line sleeves on power transmission lines should be
inspected periodically to prevent power failure. In this paper, Korea
Electric Power Research Institute reviewed several robots to inspect
line status and proposes a robot to inspect line sleeve by measuring
magnetic field on line sleeve. The developed inspection tool can
reliable to move along transmission line and overcome several
obstacles on transmission line. The developed system is also applied
on power transmission line and verified the efficiency of the robot.
Abstract: In this paper, the transformers over-load problem of Shiraz substation in Fars Regional Electric Company (FREC) is investigated for a period of three years plan. So the suggestions for using phase shifting transformer (PST) and unified power flow controller (UPFC) in order to solve this problem are examined in details and finally, some economical and practical designs will be given in order to solve the related problems. Practical consideration and using the basic and fundamental concept of powers in transmission lines in order to find the economical design are the main advantages of this research. The simulation results of the integrated overall system with different designs compare them base on economical and practical aspects to solve the over-load and loss-reduction.
Abstract: The distance protection mainly the impedance relay which is considered as the main protection for transmission lines can be subjected to impedance measurement error which is, mainly, due to the fault resistance and to the power fluctuation. Thus, the impedance relay may not operate for a short circuit at the far end of the protected line (case of the under reach) or operates for a fault beyond its protected zone (case of overreach). In this paper, an approach to fault detection by a distance protection, which distinguishes between the faulty conditions and the effect of overload operation mode, has been developed. This approach is based on the symmetrical components; mainly the negative sequence, and it is taking into account both the effect of fault resistance and the overload situation which both have an effect upon the reliability of the protection in terms of dependability for the former and security for the latter.
Abstract: Discrete particle swarm optimization (DPSO) is a
powerful stochastic evolutionary algorithm that is used to solve the
large-scale, discrete and nonlinear optimization problems. However,
it has been observed that standard DPSO algorithm has premature
convergence when solving a complex optimization problem like
transmission expansion planning (TEP). To resolve this problem an
advanced discrete particle swarm optimization (ADPSO) is proposed
in this paper. The simulation result shows that optimization of lines
loading in transmission expansion planning with ADPSO is better
than DPSO from precision view point.
Abstract: Protection system hidden failures have been identified as one of the main causes of system cascading collapse resulting to power system instability. In this paper, a systematic approach is presented in order to identify the probability of a system cascading collapse by taking into consideration the effect of protection system hidden failure. This includes the accurate calculation of the probability of hidden failure as it will provide significant impinge on the findings of the probability of system cascading collapse. The probability of a system cascading collapse is then used to identify the initial tripping of sensitive transmission lines which will contribute to a critical system cascading collapse. Based on the results obtained from this study, it is important to decide on the accurate value of the hidden failure probability as it will affect the probability of a system cascading collapse.
Abstract: To determine the presence and location of faults in a transmission by the adaptation of protective distance relay based on the measurement of fixed settings as line impedance is achieved by several different techniques. Moreover, a fast, accurate and robust technique for real-time purposes is required for the modern power systems. The appliance of radial basis function neural network in transmission line protection is demonstrated in this paper. The method applies the power system via voltage and current signals to learn the hidden relationship presented in the input patterns. It is experiential that the proposed technique is competent to identify the particular fault direction more speedily. System simulations studied show that the proposed approach is able to distinguish the direction of a fault on a transmission line swiftly and correctly, therefore suitable for the real-time purposes.
Abstract: This paper presents a model for analysis the induced voltage of transmission lines (energized) acting on neighboring distribution lines (de-energized). From environmental restrictions, 22 kV distribution lines need to be installed under 115 kV transmission lines. With the installation of the two parallel circuits like this, they make the induced voltage which can cause harm to operators. This work was performed with the ATP-EMTP modeling to analyze such phenomenon before field testing. Simulation results are used to find solutions to prevent danger to operators who are on the pole.
Abstract: The interline power flow controller (IPFC) is one of
the latest generation flexible AC transmission systems (FACTS)
controller used to control power flows of multiple transmission lines.
This paper presents a mathematical model of IPFC, termed as power
injection model (PIM). This model is incorporated in Newton-
Raphson (NR) power flow algorithm to study the power flow control
in transmission lines in which IPFC is placed. A program in
MATLAB has been written in order to extend conventional NR
algorithm based on this model. Numerical results are carried out on a
standard 2 machine 5 bus system. The results without and with IPFC
are compared in terms of voltages, active and reactive power flows to
demonstrate the performance of the IPFC model.
Abstract: High Voltage (HV) transmission lines are widely
spread around residential places. They take all forms of shapes:
concrete, steel, and timber poles. Earth grid always form part of the
HV transmission structure, whereat soil resistivity value is one of the
main inputs when it comes to determining the earth grid
requirements. In this paper, the soil structure and its implication on
the electrode resistance of HV transmission poles will be explored. In
Addition, this paper will present simulation for various soil structures
using IEEE and Australian standards to verify the computation with
CDEGS software. Furthermore, the split factor behavior under
different soil resistivity structure will be presented using CDEGS
simulations.
Abstract: Voltage collapse is instability of heavily loaded electric
power systems that cause to declining voltages and blackout. Power
systems are predicated to become more heavily loaded in the future
decade as the demand for electric power rises while economic and
environmental concerns limit the construction of new transmission
and generation capacity. Heavily loaded power systems are closer to
their stability limits and voltage collapse blackouts will occur if
suitable monitoring and control measures are not taken. To control
transmission lines, it can be used from FACTS devices.
In this paper Harmony search algorithm (HSA) and Genetic
Algorithm (GA) have applied to determine optimal location of
FACTS devices in a power system to improve power system stability.
Three types of FACTS devices (TCPAT, UPFS, and SVC) have been
introduced. Bus under voltage has been solved by controlling reactive
power of shunt compensator. Also a combined series-shunt
compensators has been also used to control transmission power flow
and bus voltage simultaneously.
Different scenarios have been considered. First TCPAT, UPFS, and
SVC are placed solely in transmission lines and indices have been
calculated. Then two types of above controller try to improve
parameters randomly. The last scenario tries to make better voltage
stability index and losses by implementation of three types controller
simultaneously. These scenarios are executed on typical 34-bus test
system and yields efficiency in improvement of voltage profile and
reduction of power losses; it also may permit an increase in power
transfer capacity, maximum loading, and voltage stability margin.
Abstract: Transmission network expansion planning (TNEP) is
a basic part of power system planning that determines where, when
and how many new transmission lines should be added to the
network. Up till now, various methods have been presented to solve
the static transmission network expansion planning (STNEP)
problem. But in all of these methods, transmission expansion
planning considering network adequacy restriction has not been
investigated. Thus, in this paper, STNEP problem is being studied
considering network adequacy restriction using discrete particle
swarm optimization (DPSO) algorithm. The goal of this paper is
obtaining a configuration for network expansion with lowest
expansion cost and a specific adequacy. The proposed idea has been
tested on the Garvers network and compared with the decimal
codification genetic algorithm (DCGA). The results show that the
network will possess maximum efficiency economically. Also, it is
shown that precision and convergence speed of the proposed DPSO
based method for the solution of the STNEP problem is more than
DCGA approach.
Abstract: This paper describes a finite-difference time-domainFDTD) method to analyze lightning surge propagation in electric transmission lines. Numerical computation of solving the Telegraphist-s equations is determined and investigated its effectiveness. A source of lightning surge wave on power transmission lines is modeled by using Heidler-s surge model. The
proposed method was tested against medium-voltage power
transmission lines in comparison with the solution obtained by using
lattice diagram. As a result, the calculation showed that the method is one of accurate methods to analyze transient
lightning wave in power transmission lines.
Abstract: Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, impact of high voltage lines on the surrounding environment especially on the control room has been investigated, then to reduce electromagnetic radiation, various methods of shielding are provided and shielding effectiveness of them has been compared. It should be expressed that simulations have been done by the finite element method (FEM).