Abstract: Insulators are one of the most significant equipment in power system. The insulators’ operation may affect the power flow, line loss and reliability. The electrical parameters that influence the performance of insulator are surface leakage current, corona and dry band arcing. Electric field stresses on the insulator surface will degrade the insulating properties and lead to puncture. Electric filed stresses can be analyzed by numerical methods and experimental evaluation. As per economic aspects, evaluation by numerical methods are best. In outdoor insulation, a hydrophobic surface can facilitate to prevent water film formation on the insulation surface, which is decisive for diminishing leakage currents and partial discharge (PD) under heavy polluted environments and harsh weather conditions. Polymer materials like silicone rubber have an outstanding hydrophobic property among general insulation materials. In this paper, electrical field intensity of 220 kV porcelain and polymer double tension insulator strings at critical regions are analyzed and compared by using Finite Element Method. Hydrophobic conditions of polymer insulator with equal and unequal water molecule conditions are verified by using finite element method.
Abstract: The curing process of insulation system for electrical machines plays a determinative role for its durability and reliability. Polar structure of insulating resin molecules and used filler of insulation system can be taken as an occasion to leverage it to enhance overall characteristics of insulation system, mechanically and electrically. The curing process regime for insulating system plays an important role for its mechanical and electrical characteristics by arranging the polymerization of chain structure for resin. In this research, the effect of electrical field application on in-curing insulating system for Global Vacuum Pressurized Impregnation (GVPI) system for traction motor was considered by performing the dissipation factor, polarization and de-polarization current (PDC) and voltage endurance (aging) measurements on sample test objects. Outcome results depicted obvious improvement in mechanical strength of the insulation system as well as higher electrical characteristics with routing and long-time (aging) electrical tests. Coming together, polarization of insulation system during curing process would enhance the machine life time.
Abstract: Water suspensions of in-organic (metals and oxides)
and organic nano-objects (chitozan and collagen) were subjected to
the treatment of direct and alternative electrical fields. In addition to
quasi-periodical spatial patterning resonance-like performance of
spatial distributions of these suspensions has been found at low
frequencies of alternating electrical field. These resonances are
explained as the result of creation of equilibrium states of groups of
charged nano-objects with opposite signs of charges at the interparticle
distances where the forces of Coulomb attraction are
compensated by the repulsion forces induced by relatively negative
polarization of hydrated regions surrounding the nanoparticles with
respect to pure water. The low frequencies of these resonances are
explained by comparatively big distances between the particles and
their big masses with t\respect to masses of atoms constituting
molecules with high resonance frequencies. These new resonances
open a new approach to detailed modeling and understanding of
mechanisms of the influence of electrical fields on the functioning of
internal organs of living organisms at the level of cells and neurons.
Abstract: High gain broadband plasmonic slot nano-antenna has
been considered. The theory of plasmonic slot nano-antenna (PSNA)
has been developed. The analytical model takes into account also the
electrical field inside the metal due to imperfectness of metal in
optical range, as well as numerical investigation based on finite
element method (FEM) has been realized. It should be mentioned that
Yagi-Uda configuration improves directivity in the plane of structure.
In contrast, in this paper the possibility of directivity improvement of
proposed PSNA in perpendicular plane of structure by using
reflection metallic surface placed under the slot in fixed distance has
been demonstrated. It is well known that a directivity improvement
brings to the antenna gain increasing. This method of diagram
improving is also well known from RF antenna design theory.
Moreover the improvement of directivity in the perpendicular plane
gives more flexibility in such application as improving the light and
atom, ion, molecule interactions by using such type of plasmonic slot
antenna. By the analogy of dipole type optical antennas the widening
of working wavelengths has been realized by using bowtie geometry
of slots, which made the antenna broadband.
Abstract: This paper presents the experimental results on space charge distribution in cross-linked polyethylene (XLPE) insulating material for 22 kV power distribution system cable by using pulse electroacoustic measurement technique (PEA). Numbers of XLPE insulating material ribbon having thickness 60 μm taken from unused 22 kV high voltage cable were used as specimen in this study. DC electric field stress was applied to test specimen at room temperature (25°C). Four levels of electric field stress, 25 kV/mm, 50 kV/mm, 75 kV/mm and 100 kV/mm, were used. In order to investigate space charge distribution characteristic, space charge distribution characteristics were measured after applying electric field stress 15 min, 30 min and 60 min, respectively. The results show that applied time and magnitude of dc electric field stress play an important role to the formation of space charge.
Abstract: In this paper, we summarize recent work of the authors on nanocomputing memory devices. We investigate two memory devices, each comprising a charged metallofullerene and carbon nanotubes. The first device involves two open nanotubes of the same radius that are joined by a centrally located nanotube of a smaller radius. A metallofullerene is then enclosed inside the structure. The second device also involves a etallofullerene that is located inside a closed carbon nanotube. Assuming the Lennard-Jones interaction energy and the continuum approximation, for both devices, the metallofullerene has two symmetrically placed equal minimum energy positions. On one side the metallofullerene represents the zero information state and by applying an external electrical field, it can overcome the energy barrier, and pass from one end of the tube to the other, where the metallofullerene then represents the one information state.
Abstract: Using strength Pulse Electrical Field (PEF) in food
industries is a non-thermal process that can deactivate
microorganisms and increase penetration in plant and animals tissues
without serious impact on food taste and quality. In this paper designing and fabricating of a PEF generator has been presented. Pulse generation methods have been surveyed and the best of them
selected. The equipment by controller set can generate square pulse with adjustable parameters such as amplitude 1-5kV, frequency 0.1-10Hz, pulse width 10-100s, and duty cycle 0-100%. Setting the number of pulses, and presenting the output voltage and current
waveforms on the oscilloscope screen are another advantages of this
equipment. Finally, some food samples were tested that yielded the satisfactory results. PEF applying had considerable effects on potato, banana and purple cabbage. It caused increase Brix factor from 0.05
to 0.15 in potato solution. It is also so effective in extraction color material from purple cabbage. In the last experiment effects of PEF
voltages on color extraction of saffron scum were surveyed (about 6% increasing yield).
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetical and thermal stresses remain major failures for
insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, a source of alternating current (50 Hz) and a clear victim in a certain distance from the source is placed. With this simple model, the effects of electromagnetic radiation from the source to the victim will be investigated and several methods to reduce these effects have been presented. Therefore passive and active shields have been used. In some steps, shielding effectiveness of proposed shields will be compared. . It should be noted that simulations have been done by the finite element method (FEM).
Abstract: Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, impact of high voltage lines on the surrounding environment especially on the control room has been investigated, then to reduce electromagnetic radiation, various methods of shielding are provided and shielding effectiveness of them has been compared. It should be expressed that simulations have been done by the finite element method (FEM).
Abstract: In this paper, the computation of the electrical field distribution around AC high-voltage lines is demonstrated. The advantages and disadvantages of two different methods are described to evaluate the electrical field quantity. The first method is a seminumerical method using the laws of electrostatic techniques to simulate the two-dimensional electric field under the high-voltage overhead line. The second method which will be discussed is the finite element method (FEM) using specific boundary conditions to compute the two- dimensional electric field distributions in an efficient way.
Abstract: In nature, electromagnetic fields always appear like
atmosphere static electric field, the earth's static magnetic field and
the wide-rang frequency electromagnetic field caused by lightening.
However, besides natural electromagnetic fields (EMF), today human
beings are mostly exposed to artificial electromagnetic fields due to
technology progress and outspread use of electrical devices. To
evaluate nuisance of EMF, it is necessary to know field intensity for
every frequency which appears and compare it with allowed values.
Low frequency EMF-s around transmission and distribution lines are
time-varying quasi-static electromagnetic fields which have
conservative component of low frequency electrical field caused by
charges and eddy component of low frequency magnetic field caused
by currents. Displacement current or field delay are negligible, so
energy flow in quasi-static EMF involves diffusion, analog like heat
transfer. Electrical and magnetic field can be analyzed separately.
This paper analysis the numerical calculations in ELF-400 software
of EMF in distribution substation in shopping center. Analyzing the
results it is possible to specify locations exposed to the fields and
give useful suggestion to eliminate electromagnetic effect or reduce it
on acceptable level within the non-ionizing radiation norms and
norms of protection from EMF.
Abstract: Optimal selection of electrical insulations in electrical
machinery insures reliability during operation. From the insulation
studies of view for electrical machines, stator is the most important
part. This fact reveals the requirement for inspection of the electrical
machine insulation along with the electro-thermal stresses. In the
first step of the study, a part of the whole structure of machine in
which covers the general characteristics of the machine is chosen,
then based on the electromagnetic analysis (finite element method),
the machine operation is simulated. In the simulation results, the
temperature distribution of the total structure is presented
simultaneously by using electro-thermal analysis. The results of
electro-thermal analysis can be used for designing an optimal cooling
system. In order to design, review and comparing the cooling
systems, four wiring structures in the slots of Stator are presented.
The structures are compared to each other in terms of electrical,
thermal distribution and remaining life of insulation by using Finite
Element analysis. According to the steps of the study, an optimization
algorithm has been presented for selection of appropriate structure.
Abstract: Meshless Finite Element Methods, namely element-free Galerkin and point-interpolation method were implemented and tested concerning their applicability to typical engineering problems like electrical fields and structural mechanics. A class-structure was developed which allows a consistent implementation of these methods together with classical FEM in a common framework. Strengths and weaknesses of the methods under investigation are discussed. As a result of this work joint usage of meshless methods together with classical Finite Elements are recommended.