Abstract: The choice evaluation between oil-immersed and dry-type transformers is often controlled by cost, location, and application. This paper compares the electrical performance of liquid- filled and dry-type transformers, which will assist the customer to choose the right and efficient ones for particular applications. An accurate assessment of the time-average flux density, electric field intensity and voltage distribution in an oil-insulated and a dry-type transformer have been computed and investigated. The detailed transformer modeling and analysis has been carried out to determine electrical parameter distributions. The models of oil-immersed and dry-type transformers are developed and solved by using the finite element method (FEM) to compare the electrical parameters. The effects of non-uniform and non-coherent voltage gradient, flux density and electric field distribution on the power losses and insulation properties of transformers are studied in detail. The results show that, for the same voltage and kilo-volt-ampere (kVA) rating, oil-immersed transformers have better insulation properties and less hysteresis losses than the dry-type.
Abstract: The spoke type rotor can be used to obtain magnetic
flux concentration in permanent magnet machines. This allows the
air gap magnetic flux density to exceed the remanent flux density
of the permanent magnets but gives problems with leakage fluxes
in the magnetic circuit. The end leakage flux of one spoke type
permanent magnet rotor design is studied through measurements and
finite element simulations. The measurements are performed in the
end regions of a 12 kW prototype generator for a vertical axis
wind turbine. The simulations are made using three dimensional
finite elements to calculate the magnetic field distribution in the
end regions of the machine. Also two dimensional finite element
simulations are performed and the impact of the two dimensional
approximation is studied. It is found that the magnetic leakage flux
in the end regions of the machine is equal to about 20% of the flux
in the permanent magnets. The overestimation of the performance by
the two dimensional approximation is quantified and a curve-fitted
expression for its behavior is suggested.
Abstract: The influence of slot wedges permeability on the electromagnetic performance of three-phase permanent magnet synchronous machine is investigated in this paper. It is shown that the back-EMF waveform, electromagnetic torque and electromagnetic torque ripple are all significantly affected by slot wedges permeability. The paper presents an accurate analytical subdomain model and confirmed by finite-element analyses.
Abstract: In this study, electric field distribution analyses for
three pylon models are carried out by a Finite Element Method
(FEM) based software. Analyses are performed in both stationary and
time domains to observe instantaneous values along with the
effective ones. Considering the results of the study, different line
geometries is considerably affecting the magnitude and distribution
of electric field although the line voltages are the same. Furthermore,
it is observed that maximum values of instantaneous electric field
obtained in time domain analysis are quite higher than the effective
ones in stationary mode. In consequence, electric field distribution
analyses should be individually made for each different line model
and the limit exposure values or distances to residential buildings
should be defined according to the results obtained.
Abstract: This paper presents the effect of electric field
distribution which is an electric field intensity analysis. Consideration
of the dielectric heating of grains and insects, the rice and rice
weevils are utilized for dielectric heating analysis. Furthermore, this
analysis compares the effect of electric field distribution in rice and
rice weevil. In this simulation, two copper plates are used to generate
the electric field for dielectric heating system and put the rice
materials between the copper plates. The simulation is classified in
two cases, which are case I one rice weevil is placed in the rice and
case II two rice weevils are placed at different position in the rice.
Moreover, the probes are located in various different positions on
plate. The power feeding on this plate is optimized by using CST EM
studio program of 1000 watt electrical power at 39 MHz resonance
frequency. The results of two cases are indicated that the most
electric field distribution and intensity are occurred on the rice and
rice weevils at the near point of the probes. Moreover, the heat is
directed to the rice weevils more than the rice. When the temperature
of rice and rice weevils are calculated and compared, the rice weevils
has the temperature more than rice is about 41.62 Celsius degrees.
These results can be applied for the dielectric heating applications to
eliminate insect.
Abstract: To reveal the temperature field distribution of disc
brake in downward belt conveyor, mathematical models of heat
transfer for disc brake were established combined with heat transfer
theory. Then, the simulation process was stated in detail and the
temperature field of disc brake under conditions of dynamic speed and
dynamic braking torque was numerically simulated by using ANSYS
software. Finally the distribution and variation laws of temperature
field in the braking process were analyzed. Results indicate that the
maximum surface temperature occurs at a time before the brake end
and there exist large temperature gradients in both radial and axial
directions, while it is relatively small in the circumferential direction.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetical and thermal stresses remain major failures for
insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: Charging and discharging phenomenon on the surface
of materials can be found in plasma display panel, spacecraft
charging, high voltage insulator, etc. This report gives a simple
explanation on this phenomenon. A scanning electron microscope
was used not only as a tool to produce energetic electron beam to
charge an insulator without metallic coating and to produce a surface
discharging (surface breakdown/flashover) but also to observe the
visible charging and discharging on the sample surface. A model of
electric field distribution on the surface was developed in order to
explain charging and discharging phenomena. Since charging and
discharging process involves incubation time, therefore this process
can be used to evaluate the insulation property of materials under
electron bombardment.
Abstract: This paper presents the simulation the results of
electric field and potential distributions along surface of silicone
rubber polymer insulators. Near the same leakage distance subjected
to 15 kV in 50 cycle salt fog ageing test, alternate sheds silicone
rubber polymer insulator showed better contamination performance
than straight sheds silicone rubber polymer insulator. Severe surface
ageing was observed on the straight sheds insulator. The objective of
this work is to elucidate that electric field distribution along straight
sheds insulator higher than alternate shed insulator in salt fog ageing
test. Finite element method (FEM) is adopted for this work. The
simulation results confirmed the experimental data, as well.
Abstract: Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, a source of alternating current (50 Hz) and a clear victim in a certain distance from the source is placed. With this simple model, the effects of electromagnetic radiation from the source to the victim will be investigated and several methods to reduce these effects have been presented. Therefore passive and active shields have been used. In some steps, shielding effectiveness of proposed shields will be compared. . It should be noted that simulations have been done by the finite element method (FEM).
Abstract: This paper presents a microstrip meandered open
circuited stub with bandstop characteristic. The proposed structure is
designed on a high frequency laminate with dielectric constant of 4.0
and board thickness of 0.508 millimeters. The scattering parameters
and electromagnetic field distributions at various frequencies are
investigated by modeling the structure with three dimensional
electromagnetic simulation tool. In order to describe the resonant
and bandstop characteristic of the meandered open circuited stub, a
Smith chart as well as electric field at various frequencies and phases
is illustrated accordingly. The structure can be an alternative method
in suppressing the harmonic response of a bandpass filter.
Abstract: The paper deals with determination of electromagnetic
and temperature field distribution of induction heating system used
for pipe brazing. The problem is considered as coupled – time
harmonic electromagnetic and transient thermal field. It has been
solved using finite element method. The detailed maps of
electromagnetic and thermal field distribution have been obtained.
The good understanding of the processes in the considered system
ensures possibilities for control, management and increasing the
efficiency of the welding process.
Abstract: This paper proposes a set of quasi-static mathematical
model of magnetic fields caused by high voltage conductors of
distribution transformer by using a set of second-order partial
differential equation. The modification for complex magnetic field
analysis and time-harmonic simulation are also utilized. In this
research, transformers were study in both balanced and unbalanced
loading conditions. Computer-based simulation utilizing the threedimensional
finite element method (3-D FEM) is exploited as a tool
for visualizing magnetic fields distribution volume a distribution
transformer. Finite Element Method (FEM) is one among popular
numerical methods that is able to handle problem complexity in
various forms. At present, the FEM has been widely applied in most
engineering fields. Even for problems of magnetic field distribution,
the FEM is able to estimate solutions of Maxwell-s equations
governing the power transmission systems. The computer simulation
based on the use of the FEM has been developed in MATLAB
programming environment.
Abstract: This paper presents the simulation results of electric field and potential distributions along surface of silicone rubber polymer insulators under clean and various contamination conditions with/without water droplets. Straight sheds insulator having leakage distance 290 mm was used in this study. Two type of contaminants, playwood dust and cement dust, have been studied the effect of contamination on the insulator surface. The objective of this work is to comparison the effect of contamination on potential and electric field distributions along the insulator surface when water droplets exist on the insulator surface. Finite element method (FEM) is adopted for this work. The simulation results show that contaminations have no effect on potential distribution along the insulator surface while electric field distributions are obviously depended on contamination conditions.
Abstract: Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, impact of high voltage lines on the surrounding environment especially on the control room has been investigated, then to reduce electromagnetic radiation, various methods of shielding are provided and shielding effectiveness of them has been compared. It should be expressed that simulations have been done by the finite element method (FEM).
Abstract: In this paper, the computation of the electrical field distribution around AC high-voltage lines is demonstrated. The advantages and disadvantages of two different methods are described to evaluate the electrical field quantity. The first method is a seminumerical method using the laws of electrostatic techniques to simulate the two-dimensional electric field under the high-voltage overhead line. The second method which will be discussed is the finite element method (FEM) using specific boundary conditions to compute the two- dimensional electric field distributions in an efficient way.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetically and thermal stresses remain major failures
for insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: In the present work, an attempt is made to understand
electromagnetic field confinement in a subwavelength waveguide
structure using concepts of quantum mechanics. Evanescent field in
the waveguide is looked as inability of the photon to get confined in
the waveguide core and uncertainty of position is assigned to it. The
momentum uncertainty is calculated from position uncertainty.
Schrödinger wave equation for the photon is written by incorporating
position-momentum uncertainty. The equation is solved and field
distribution in the waveguide is obtained. The field distribution and
power confinement is compared with conventional waveguide theory.
They were found in good agreement with each other.
Abstract: Optimal selection of electrical insulations in electrical
machinery insures reliability during operation. From the insulation
studies of view for electrical machines, stator is the most important
part. This fact reveals the requirement for inspection of the electrical
machine insulation along with the electro-thermal stresses. In the
first step of the study, a part of the whole structure of machine in
which covers the general characteristics of the machine is chosen,
then based on the electromagnetic analysis (finite element method),
the machine operation is simulated. In the simulation results, the
temperature distribution of the total structure is presented
simultaneously by using electro-thermal analysis. The results of
electro-thermal analysis can be used for designing an optimal cooling
system. In order to design, review and comparing the cooling
systems, four wiring structures in the slots of Stator are presented.
The structures are compared to each other in terms of electrical,
thermal distribution and remaining life of insulation by using Finite
Element analysis. According to the steps of the study, an optimization
algorithm has been presented for selection of appropriate structure.
Abstract: A power cable is widely used for power supply in
power distributing networks and power transmission lines. Due to
limitations in the production, delivery and setting up power cables,
they are produced and delivered in several separate lengths. Cable
itself, consists of two cable terminations and arbitrary number of
cable joints, depending on the cable route length. Electrical stress
control is needed to prevent a dielectric breakdown at the end of the
insulation shield in both the air and cable insulation. Reliability of
cable joint depends on its materials, design, installation and operating
environment. The paper describes design and performance results for
new modeled cable joints. Design concepts, based on numerical
calculations, must be correct. An Equivalent Electrodes
Method/Boundary Elements Method-hybrid approach that allows
electromagnetic field calculations in multilayer dielectric media,
including inhomogeneous regions, is presented.