Abstract: Transmission networks are an important part of an electric power system. The transmission lines not only have high power transmission capacity but also they are prone of larger magnitudes. Different types of faults occur in transmission lines such as single line to ground (L-G) fault, double line to ground (L-L-G) fault, line to line (L-L) fault and three phases (L-L-L) fault. These faults are needed to be cleared quickly in order to reduce damage caused to the system and they have high impact on the electrical power system equipment’s which are connected in transmission line. The main fault in transmission line is L-G fault. Therefore, protection relays are needed to protect transmission line. Overcurrent and earth fault relay is an important relay used to protect transmission lines, distribution feeders, transformers and bus couplers etc. Sometimes these relays can be used as main protection or backup protection. The modeling of protection relays is important to indicate the effects of network parameters and configurations on the operation of relays. Therefore, the modeling of overcurrent and earth fault relay is described in this paper. The overcurrent and earth fault relays with standard inverse definite minimum time are modeled and simulated by using MATLAB/Simulink software. The developed model was tested with L-G, L-L-G, L-L and L-L-L faults with various fault locations and fault resistance (0.001Ω). The simulation results are obtained by MATLAB software which shows the feasibility of analysis of transmission line protection with overcurrent and earth fault relay.
Abstract: The demand for power supply increases day by day in developing countries like India henceforth demand of reactive power support in the form of ancillary services provider also has been increased. The multi-line and multi-type Flexible alternating current transmission system (FACTS) controllers are playing a vital role to regulate power flow through the transmission line. Unified power flow controller and interline power flow controller can be utilized to control reactive power flow through the transmission line. In a restructured power system, the demand of such controller is being popular due to their inherent capability. The transmission pricing by using reactive power cost allocation through modified matrix methodology has been proposed. The FACTS technologies have quite costly assembly, so it is very useful to apportion the expenses throughout the restructured electricity industry. Therefore, in this work, after embedding the FACTS devices into load flow, the impact on the costs allocated to users in fraction to the transmission framework utilization has been analyzed. From the obtained results, it is clear that the total cost recovery is enhanced towards the Reactive Power flow through the different transmission line for 5 bus test system. The fair pricing policy towards reactive power can be achieved by the proposed method incorporating FACTS controller towards cost recovery of the transmission network.
Abstract: Single phase transmission lines are used to transfer data or energy between two users. Transient conditions such as switching operations and short circuit faults cause the generation of the fluctuation on the waveform to be transmitted. Spatial voltage distribution on the single phase transmission line may change owing to the position and duration of the short circuit fault in the system. In this paper, the state space representation of the single phase transmission line for short circuit fault and for various types of terminations is given. Since the transmission line is modeled in time domain using distributed parametric elements, the mathematical representation of the event is given in state space (time domain) differential equation form. It also makes easy to solve the problem because of the time and space dependent characteristics of the voltage variations on the distributed parametrically modeled transmission line.
Abstract: An electrical power system has some negative aspects such as flickering and deviations of voltage/power. This can be eliminated using energy storage devices that will provide a backup energy at the time of voltage/power deviations. Energy-storage devices get charging when system voltage/power is higher than reference value and discharging when system voltage/power is lower than reference value, it is acting as catalysts to provide energy boost. In this paper, a dynamic control of Unified Power Flow Controller (UPFC) integrated with superconducting magnetic energy storage (SMES) is developed to improve the power quality, power oscillation damping, and dynamic voltage stability through the transmission line. UPFC inter-connected to SMES through an interface with DC-DC chopper. This inter-connected system is capable of injecting (absorbing) the real and reactive power into (from) the system at the beginning of stability problems. In this paper, the simulation results of UPFC integrated with SMES and UPFC integrated with fuel cells (FCs) are compared using MATLAB/Simulink software package.
Abstract: In this paper, a modified Wilkinson power divider for
GSM application is presented. The quarter–wavelength microstrip
lines in the conventional Wilkinson power divider (WPD) are
replaced by one-eighth wavelength transmission line. Wilkinson
power divider is designed using λ/4 and λ/8 transmission line. It has
the operating frequency of 915 MHz which is used in the GSM
standard. The proposed Wilkinson Power Divider is designed using
the simulation tool Advanced Design System. The results of λ/8
transmission line are very close to the results of λ/4 transmission line.
The isolation loss of λ/8 transmission line is improved by introducing
a capacitor between the output ports. The proposed Wilkinson power
divider has the best return loss of greater than -10 dB and isolation
loss of -15.25 dB. The λ/8 transmission line Wilkinson power divider
has the reduced size of 53.9 percentages than λ/4 transmission line
WPD. The proposed design has simple structure, better isolation loss
and good insertion loss.
Abstract: This paper presents a case study of using STATCOM to enhance the performance of Al-Qatraneh 33-kV transmission line. The location of the STATCOM was identified by maintaining minimum voltage drops at the 110 load nodes. The transmission line and the 110 load nodes have been modeled by MATLAB/Simulink. The suggested STATCOM and its location will increase the transmission capability of this transmission line and overcome the overload expected in the year 2020. The annual percentage loading rise has been considered as 14.35%. A graphical representation of the line-to-line voltages and the voltage drops at different load nodes is illustrated.
Abstract: Crosstalk among interconnects and printed-circuit
board (PCB) traces is a major limiting factor of signal quality in highspeed
digital and communication equipments especially when fast
data buses are involved. Such a bus is considered as a planar
multiconductor transmission line. This paper will demonstrate how
the finite difference time domain (FDTD) method provides an exact
solution of the transmission-line equations to analyze the near end
and the far end crosstalk. In addition, this study makes it possible to
analyze the rise time effect on the near and far end voltages of the
victim conductor. The paper also discusses a statistical analysis,
based upon a set of several simulations. Such analysis leads to a
better understanding of the phenomenon and yields useful
information.
Abstract: Static VAR System (SVS) is a kind of FACTS device which is used in power system primarily for the purpose of voltage and reactive power control. In this paper presents a systematic approach for designing SVS supplementary controller, which is used to improve the damping of power system oscillation. The combined bus voltage and line current (CBVLC) supplementary controller has been developed and incorporated in the SVS control system located at the middle of the series compensated long transmission line. Damping of torsional stresses due to subsynchronous resonance resulting from series capacitive compensation using CBVLC is investigated in this paper. Simulation results are carried out with MATLAB/Simulink on the IEEE first benchmark model (FBM). The simulation results show that the oscillations are satisfactorily damped out by the SVS supplementary controller. Time domain simulation is performed on power system and the results demonstrate the effectiveness of the proposed controller.
Abstract: The line sleeves on power transmission line connects
two conductors while the transmission line is constructing. However,
the line sleeves sometimes cause transmission line break down,
because the line sleeves are deteriorated and decayed by acid rain.
When the transmission line is broken, the economical loss is huge.
Therefore the line sleeves on power transmission lines should be
inspected periodically to prevent power failure. In this paper, Korea
Electric Power Research Institute reviewed several robots to inspect
line status and proposes a robot to inspect line sleeve by measuring
magnetic field on line sleeve. The developed inspection tool can
reliable to move along transmission line and overcome several
obstacles on transmission line. The developed system is also applied
on power transmission line and verified the efficiency of the robot.
Abstract: A considerable progress has been achieved in transient
stability analysis (TSA) with various FACTS controllers. But, all
these controllers are associated with single transmission line. This
paper is intended to discuss a new approach i.e. a multi-line FACTS
controller which is interline power flow controller (IPFC) for TSA of
a multi-machine power system network. A mathematical model of
IPFC, termed as power injection model (PIM) presented and this
model is incorporated in Newton-Raphson (NR) power flow
algorithm. Then, the reduced admittance matrix of a multi-machine
power system network for a three phase fault without and with IPFC
is obtained which is required to draw the machine swing curves. A
general approach based on L-index has also been discussed to find
the best location of IPFC to reduce the proximity to instability of a
power system. Numerical results are carried out on two test systems
namely, 6-bus and 11-bus systems. A program in MATLAB has
been written to plot the variation of generator rotor angle and speed
difference curves without and with IPFC for TSA and also a simple
approach has been presented to evaluate critical clearing time for test
systems. The results obtained without and with IPFC are compared
and discussed.
Abstract: The distance protection mainly the impedance relay which is considered as the main protection for transmission lines can be subjected to impedance measurement error which is, mainly, due to the fault resistance and to the power fluctuation. Thus, the impedance relay may not operate for a short circuit at the far end of the protected line (case of the under reach) or operates for a fault beyond its protected zone (case of overreach). In this paper, an approach to fault detection by a distance protection, which distinguishes between the faulty conditions and the effect of overload operation mode, has been developed. This approach is based on the symmetrical components; mainly the negative sequence, and it is taking into account both the effect of fault resistance and the overload situation which both have an effect upon the reliability of the protection in terms of dependability for the former and security for the latter.
Abstract: In this paper the performance of unified power flow
controller is investigated in controlling the flow of po wer over the
transmission line. Voltage sources model is utilized to study the
behaviour of the UPFC in regulating the active, reactive power and
voltage profile. This model is incorporated in Newton Raphson
algorithm for load flow studies. Simultaneous method is employed
in which equations of UPFC and the power balance equations of
network are combined in to one set of non-linear algebraic equations.
It is solved according to the Newton raphson algorithm. Case studies
are carried on standard 5 bus network. Simulation is done in Matlab.
The result of network with and without using UPFC are compared in
terms of active and reactive power flows in the line and active and
reactive power flows at the bus to analyze the performance of UPFC.
Abstract: This paper presents the impact study of GTO Controlled Series Capacitor (GCSC) parameters on measured impedance (Zseen) by MHO distance relays for single transmission line high voltage 220 kV in the presence of single phase to earth fault with fault resistance (RF). The study deals with a 220 kV single electrical transmission line of Eastern Algerian transmission networks at Group Sonelgaz (Algerian Company of Electrical and Gas) compensated by series Flexible AC Transmission System (FACTS) i.e. GCSC connected at midpoint of the transmission line. The transmitted active and reactive powers are controlled by three GCSC-s. The effects of maximum reactive power injected as well as injected maximum voltage by GCSC on distance relays measured impedance is treated. The simulations results investigate the effects of GCSC injected parameters: variable reactance (XGCSC), variable voltage (VGCSC) and reactive power injected (QGCSC) on measured resistance and reactance in the presence of earth fault with resistance fault varied between 5 to 50 Ω for three cases study.
Abstract: Analytical expression for maximum power transfer
through a transmission line limited by voltage stability has been
formulated using exact representation of transmission line with
ABCD parameters. The expression has been used for plotting PV
curve at different power factors of a radial transmission line.
Limiting values of reactive power have been obtained.
Abstract: Distance protection of transmission lines including advanced flexible AC transmission system (FACTS) devices has been a very challenging task. FACTS devices of interest in this paper are static synchronous series compensators (SSSC) and unified power flow controller (UPFC). In this paper, a new algorithm is proposed to detect and classify the fault and identify the fault position in a transmission line with respect to a FACTS device placed in the midpoint of the transmission line. Discrete wavelet transformation and wavelet entropy calculations are used to analyze during fault current and voltage signals of the compensated transmission line. The proposed algorithm is very simple and accurate in fault detection and classification. A variety of fault cases and simulation results are introduced to show the effectiveness of such algorithm.
Abstract: This paper presents the mathematical model of electric field and magnetic field in transmission system, which performs in second-order partial differential equation. This research has conducted analyzing the electromagnetic field radiating to atmosphere around the transmission line, when there is the transmission line transposition in case of long distance distribution. The six types of 500 kV transposed HV transmission line with double circuit will be considered. The computer simulation is applied finite element method that is developed by MATLAB program. The problem is considered to two dimensions, which is time harmonic system with the graphical performance of electric field and magnetic field. The impact from simulation of six types long distance distributing transposition will not effect changing of electric field and magnetic field which surround the transmission line.
Abstract: This paper presents the development of adaptive
distance relay for protection of parallel transmission line with mutual
coupling. The proposed adaptive relay, automatically adjusts its
operation based on the acquisition of the data from distance relay of
adjacent line and status of adjacent line from line circuit breaker IED
(Intelligent Electronic Device). The zero sequence current of the
adjacent parallel transmission line is used to compute zero sequence
current ratio and the mutual coupling effect is fully compensated.
The relay adapts to changing circumstances, like failure in
communication from other relays and non - availability of adjacent
transmission line. The performance of the proposed adaptive relay is
tested using steady state and dynamic test procedures. The fault
transients are obtained by simulating a realistic parallel transmission
line system with mutual coupling effect in PSCAD. The evaluation
test results show the efficacy of adaptive distance relay over the
conventional distance relay.
Abstract: Series compensators have been used for many years,
to increase the stability and load ability of transmission line. They
compensate retarded or advanced volt drop of transmission lines
by placing advanced or retarded voltage in series with them to
compensate the effective reactance, which cause to increase load
ability of transmission lines. In this paper, two method of fuzzy
controller, based on power reference tracking and impedance
reference tracking have been developed on TCSC controller in
order to increase load ability and improving power oscillation
damping of system. In these methods, fire angle of thyristors are
determined directly through the special Rule-bases with the error
and change of error as the inputs. The simulation results of two
area four- machines power system show the good performance of
power oscillation damping in system. Comparison of this method
with classical PI controller shows the increasing speed of system
response in power oscillation damping.
Abstract: This paper provides the design steps of a robust Linear
Matrix Inequality (LMI) based iterative multivariable PID controller
whose duty is to drive a sample power system that comprises a
synchronous generator connected to a large network via a step-up
transformer and a transmission line. The generator is equipped with
two control-loops, namely, the speed/power (governor) and voltage
(exciter). Both loops are lumped in one where the error in the
terminal voltage and output active power represent the controller
inputs and the generator-exciter voltage and governor-valve position
represent its outputs. Multivariable PID is considered here because of
its wide use in the industry, simple structure and easy
implementation. It is also preferred in plants of higher order that
cannot be reduced to lower ones. To improve its robustness to
variation in the controlled variables, H∞-norm of the system transfer
function is used. To show the effectiveness of the controller, divers
tests, namely, step/tracking in the controlled variables, and variation
in plant parameters, are applied. A comparative study between the
proposed controller and a robust H∞ LMI-based output feedback is
given by its robustness to disturbance rejection. From the simulation
results, the iterative multivariable PID shows superiority.