Abstract: This paper presents a novel statistical description of
the counterpoise effective length due to lightning surges, where the
(impulse) effective length had been obtained by means of regressive
formulas applied to the transient simulation results. The effective
length is described in terms of a statistical distribution function, from
which median, mean, variance, and other parameters of interest could
be readily obtained. The influence of lightning current amplitude,
lightning front duration, and soil resistivity on the effective length has
been accounted for, assuming statistical nature of these parameters. A
method for determining the optimal counterpoise length, in terms of
the statistical impulse effective length, is also presented. It is based on
estimating the number of dangerous events associated with lightning
strikes. Proposed statistical description and the associated method
provide valuable information which could aid the design engineer in
optimising physical lengths of counterpoises in different grounding
arrangements and soil resistivity situations.
Abstract: The condition of lightning surge causes the traveling waves and the temporary increase in voltage in the transmission line system. Lightning is the most harmful for destroying the transmission line and setting devices so it is necessary to study and analyze the temporary increase in voltage for designing and setting the surge arrester. This analysis describes the figure of the lightning wave in transmission line with 115 kV voltage level in Thailand by using ATP/EMTP program to create the model of the transmission line and lightning surge. Because of the limit of this program, it must be calculated for the geometry of the transmission line and surge parameter and calculation in the manual book for the closest value of the parameter. On the other hand, for the effects on surge protector when the lightning comes, the surge arrester model must be right and standardized as metropolitan electrical authority's standard. The candidate compared the real information to the result from calculation, also. The results of the analysis show that the temporary increase in voltage value will be rise to 326.59 kV at the line which is done by lightning when the surge arrester is not set in the system. On the other hand, the temporary increase in voltage value will be 182.83 kV at the line which is done by lightning when the surge arrester is set in the system and the period of the traveling wave is reduced, also. The distance for setting the surge arrester must be as near to the transformer as possible. Moreover, it is necessary to know the right distance for setting the surge arrester and the size of the surge arrester for preventing the temporary increase in voltage, effectively.
Abstract: This paper describes a finite-difference time-domainFDTD) method to analyze lightning surge propagation in electric transmission lines. Numerical computation of solving the Telegraphist-s equations is determined and investigated its effectiveness. A source of lightning surge wave on power transmission lines is modeled by using Heidler-s surge model. The
proposed method was tested against medium-voltage power
transmission lines in comparison with the solution obtained by using
lattice diagram. As a result, the calculation showed that the method is one of accurate methods to analyze transient
lightning wave in power transmission lines.