Abstract: One of the aims of the paper is to make a comparison
of experimental results with numerical simulation for a side cooler.
Specifically, it was the amount of air to be delivered by the side
cooler with fans running at 100%. This integral value was measured
and evaluated within the plane parallel to the front side of the side
cooler at a distance of 20mm from the front side. The flow field
extending from the side cooler to the space was also evaluated.
Another objective was to address the contribution of evaluated values
to the increase of data center energy consumption.
Abstract: Mobile Ad Hoc Networks (MANETs) are multi-hop
wireless networks in which all nodes cooperatively maintain network
connectivity. In such a multi-hop wireless network, every node may
be required to perform routing in order to achieve end-to-end
communication among nodes. These networks are energy constrained
as most ad hoc mobile nodes today operate with limited battery
power. Hence, it is important to minimize the energy consumption of
the entire network in order to maximize the lifetime of ad hoc
networks. In this paper, a mechanism involving the integration of
load balancing approach and transmission power control approach is
introduced to maximize the life-span of MANETs. The mechanism is
applied on Ad hoc On-demand Vector (AODV) protocol to make it
as energy aware AODV (EA_AODV). The simulation is carried out
using GloMoSim2.03 simulator. The results show that the proposed
mechanism reduces the average required transmission energy per
packet compared to the standard AODV.
Abstract: Due to rapid economic growth, Indonesia's energy needs is rapidly increasing. Indonesia-s primary energy consumption has doubled in 2007 compared to 2003. Indonesia's status change from oil net-exporter to oil net-importer country recently has increased Indonesia's concern over energy security. Due to this, oil import becomes center of attention in the dynamics of Indonesia's energy security. Conventional studies addressing Indonesia's energy security have focused on energy production sector. This study explores Indonesia-s energy security considering energy import sector by modeling and simulating Indonesia-s energy-related policies using system dynamics. Simulation result of Indonesia's energy security in 2020 in Business-As-Usual scenario shows that in term of supply demand ratio, energy security will be very high, but also it poses high dependence on energy import. The Alternative scenario result shows lower energy security in term of supply demand ratio and much lower dependence on energy import. It is also found that the Alternative scenario produce lower GDP growth.
Abstract: In this paper we present an energy efficient match-line
(ML) sensing scheme for high-speed ternary content-addressable
memory (TCAM). The proposed scheme isolates the sensing unit of
the sense amplifier from the large and variable ML capacitance. It
employs feedback in the sense amplifier to successfully detect a
match while keeping the ML voltage swing low. This reduced voltage
swing results in large energy saving. Simulation performed using
130nm 1.2V CMOS logic shows at least 30% total energy saving in
our scheme compared to popular current race (CR) scheme for
similar search speed. In terms of speed, dynamic energy, peak power
consumption and transistor count our scheme also shows better
performance than mismatch-dependant (MD) power allocation
technique which also employs feedback in the sense amplifier.
Additionally, the implementation of our scheme is simpler than CR
or MD scheme because of absence of analog control voltage and
programmable delay circuit as have been used in those schemes.
Abstract: Wireless Sensor Networks consist of small battery
powered devices with limited energy resources. once deployed, the
small sensor nodes are usually inaccessible to the user, and thus
replacement of the energy source is not feasible. Hence, One of the
most important issues that needs to be enhanced in order to improve
the life span of the network is energy efficiency. to overcome this
demerit many research have been done. The clustering is the one of
the representative approaches. in the clustering, the cluster heads
gather data from nodes and sending them to the base station. In this
paper, we introduce a dynamic clustering algorithm using genetic
algorithm. This algorithm takes different parameters into
consideration to increase the network lifetime. To prove efficiency of
proposed algorithm, we simulated the proposed algorithm compared
with LEACH algorithm using the matlab
Abstract: Trust and Energy consumption is the most challenging
issue in routing protocol design for Mobile ad hoc networks
(MANETs), since mobile nodes are battery powered and nodes
behaviour are unpredictable. Furthermore replacing and recharging
batteries and making nodes co-operative is often impossible in
critical environments like military applications. In this paper, we
propose a trust based energy aware routing model in MANET.
During route discovery, node with more trust and maximum energy
capacity is selected as a router based on a parameter called
'Reliability'. Route request from the source is accepted by a node
only if its reliability is high. Otherwise, the route request is
discarded. This approach forms a reliable route from source to
destination thus increasing network life time, improving energy
utilization and decreasing number of packet loss during transmission.
Abstract: The activities which are mostly related to the environmental performance need to be pointed, especially how logistics systems influence on environmental performance. This paper analyses how company could lead the initiative in this area by incorporating environmental management principles into their daily activities. The analysis is based on literature review about logistics and environment, the information from company R website as well as face-to-face interviews. A case study is given to show how they can turn practices into green while simultaneously meet the efficiency objectives. The research results show that the adoption of EMS and ISO 14001 certification is an effective tool for the logistics management. Such practices simultaneously reduce the negative contribute to better company performance. The results also show that the emissions to air and water, and energy consumption are the main logistics impacts to the environment.
Abstract: Energy consumption rate during the cooling process
of industrial glass tempering process is considerably high. In this
experimental study the effect of dimensionless jet to jet distance
(S/D) and jet to plate distance (H/D) on the cooling time have been
investigated. In the experiments 4 mm thick glass samples have been
used. Cooling unit consists of 16 mutually placed seamless aluminum
nozzles of 8 mm in diameter and 80 mm in length. Nozzles were in
staggered arrangement. Experiments were conducted with circular
jets for H/D values between 1 and 10, and for S/D values between 2
and 10. During the experiments Reynolds number has been kept
constant at 30000. Experimental results showed that the longest
cooling time with 87 seconds has been observed in the experiments
for S/D=10 and H/D=10 values, while the shortest cooling time with
42.5 seconds has been measured in the experiments for S/D=2 and
H/D=4 values.
Abstract: Greenhouse gases (GHG) emissions impose major
threat to global warming potential (GWP). Unfortunately
manufacturing sector is one of the major sources that contribute
towards the rapid increase in greenhouse gases (GHG) emissions. In
manufacturing sector electric power consumption is the major driver
that influences CO2 emission. Titanium alloys are widely utilized in
aerospace, automotive and petrochemical sectors because of their
high strength to weight ratio and corrosion resistance. Titanium
alloys are termed as difficult to cut materials because of their poor
machinability rating. The present study analyzes energy consumption
during cutting with reference to material removal rate (MRR).
Surface roughness was also measured in order to optimize energy
consumption.
Abstract: To simulate heating systems in buildings, a research oriented computer code has been developed in Sharif University of Technology in Iran where the climate, existing heating equipment in buildings, consumer behavior and their interactions are considered for simulating energy consumption in conventional systems such as heaters, radiators and fan-coils. In order to validate the computer code, the available data of five buildings was used and the computed consumed energy was compared with the estimated energy extracted from monthly bills. The initial heating system was replaced by the alternative system and the effect of this change was observed on the energy consumption. As a result, the effect of changing heating equipment on energy consumption was investigated in different climates. Changing heater to radiator renders energy conservation up to 50% in all climates and changing radiator to fan-coil decreases energy consumption in climates with cold and dry winter.
Abstract: This paper investigated the impact of ceiling height and window head heights variation on daylighting inside architectural teaching studio with a full width window. In architectural education, using the studio is more than normal classroom in most credit hours. Therefore, window position, size and dimension of studio have direct influence on level of daylighting. Daylighting design is a critical factor that improves student learning, concentration and behavior, in addition to these, it also reduces energy consumption. The methodology of analysis involves using Radiance in IES software under overcast and cloudy sky in Malaysia. It has been established that presentation of daylighting of architecture studio can be enhanced by changing the ceiling heights and window level, because, different ceiling heights and window head heights can contribute to different range of daylight levels.
Abstract: Building Sector is the major electricity consumer and
it is costly to building owners. Therefore the application of thermal
energy storage (TES) has gained attractive to reduce energy cost.
Many attractive tariff packages are being offered by the electricity
provider to promote TES. The tariff packages offered higher cost of
electricity during peak period and lower cost of electricity during off
peak period. This paper presented the return of initial investment by
implementing a centralized air-conditioning plant integrated with
thermal energy storage with partially operation strategies. Building
load profile will be calculated hourly according to building
specification and building usage trend. TES operation conditions will
be designed according to building load demand profile, storage
capacity, tariff packages and peak/off peak period. The Payback
Period analysis method was used to evaluate economic analysis. The
investment is considered a good investment where by the initial cost
is recovered less than ten than seven years.
Abstract: The globe Sustainability has become the subject of international attention, the key reason is that global climate change. Climate and disasters around the abnormal frequency multiplier, the global temperature of the catastrophe and disaster continue to occur throughout the world, as well as countries around the world. Currently there are many important international conferences and policy, it is a "global environmental sustainability " and "living human health " as the goal of development, including the APEC 2007 meeting to "climate Clean Energy" as the theme Sydney Declaration, 2008 World Economic Forum's "Carbon - promote Cool Earth energy efficiency improvement project", the EU proposed "Green Idea" program, the Japanese annual policy, "low-carbon society, sustainable eco-city environment (Eco City) "And from 2009 to 2010 to promote the "Eco-Point" to promote green energy and carbon reduction products .And the 2010 World Climate Change Conference (COP16 United Nations Climate Change Conference Copenhagen), the world has been the subject of Negative conservative "Environmental Protection ", "save energy consumption, " into a positive response to the "Sustainable " and" LOHAS", while Taiwan has actively put forward eco-cities, green building, green building materials and other related environmental response Measures, especially green building construction environment that is the basis of factors, the most widely used application level, and direct contact with human health and the key to sustainable planet. "Sustainable development "is a necessary condition for continuation of the Earth, "healthy and comfortable" is a necessary condition for the continuation of life, and improve the "quality" is a necessary condition for economic development, balance between the three is "to enhance the efficiency of ", According to the World Business Council for Sustainable Development (WBCSD) for the "environmental efficiency "(Eco-Efficiency) proposed: " the achievement of environmental efficiency, the price to be competitive in the provision of goods or services to meet people's needs, improve living Quality at the same time, the goods or services throughout the life cycle. Its impact on the environment and natural resource utilization and gradually reduced to the extent the Earth can load. "whichever is the economy "Economic" and " Ecologic". The research into the methodology to obtain the Taiwan Green Building Material Labeling product as the scope of the study, by investigating and weight analysis to explore green building environmental load (Ln) factor and the Green Building Quality (Qn) factor to Establish green building environmental efficiency assessment model (GBM Eco-Efficiency). And building materials for healthy green label products for priority assessment object, the object is set in the material evidence for the direct response to the environmental load from the floor class-based, explicit feedback correction to the Green Building environmental efficiency assessment model, "efficiency " as a starting point to achieve balance between human "health "and Earth "sustainable development of win-win strategy. The study is expected to reach 1.To establish green building materials and the quality of environmental impact assessment system, 2. To establish value of GBM Eco-Efficiency model, 3. To establish the GBM Eco-Efficiency model for application of green building material feedback mechanisms.
Abstract: Solar shading designs are important for reduction of building energy consumption and improvement of indoor thermal environment. This paper carried out a number of building simulations for evaluation of the energy performance of different shading devices based on incremental costs. The results show that movable shading devices lower incremental costs by up to 50% compared with fixed ones for the same building energy efficiency for residential buildings, and wing panel shadings are much more suitable in commercial buildings than baring screen ones and overhangs for commercial buildings.
Abstract: Sensor networks are often deployed in unattended
environments, thus leaving these networks vulnerable to false data
injection attacks in which an adversary injects forged reports into the
network through compromised nodes, with the goal of deceiving the
base station or depleting the resources of forwarding nodes. Several
research solutions have been recently proposed to detect and drop such
forged reports during the forwarding process. Each design can provide
the equivalent resilience in terms of node compromising. However,
their energy consumption characteristics differ from each other. Thus,
employing only a single filtering scheme for a network is not a
recommendable strategy in terms of energy saving. It's very important
the threshold determination for message authentication to identify. We
propose the recursive contract net protocols which less energy level of
terminal node in wireless sensor network.
Abstract: The increasing demand for sufficient and clean
energy forces industrial and service companies to align their strategies towards efficient consumption. This trend refers also to the
residential building sector. There, large amounts of energy consumption are caused by house and facility heating. Many of the
operated hot water heating systems lack hydraulic balanced working
conditions for heat distribution and –transmission and lead to
inefficient heating. Through hydraulic balancing of heating systems,
significant energy savings for primary and secondary energy can be
achieved. This paper addresses the use of KNX-technology (Smart
Buildings) in residential buildings to ensure a dynamic adaption of
hydraulic system's performance, in order to increase the heating
system's efficiency. In this paper, the procedure of heating system
segmentation into hydraulically independent units (meshes) is
presented. Within these meshes, the heating valve are addressed and
controlled by a central facility server. Feasibility criteria towards
such drivers will be named. The dynamic hydraulic balance is
achieved by positioning these valves according to heating loads, that
are generated from the temperature settings in the corresponding
rooms. The energetic advantages of single room heating control
procedures, based on the application FacilityManager, is presented.
Abstract: The building sector is the largest energy consumer and
CO2 emitter in the European Union (EU) and therefore the active
reduction of energy consumption and elimination of energy wastage
are among the main goals in it. Healthy housing and energy
efficiency are affected by many factors which set challenges to
monitoring, control and research of indoor air quality (IAQ) and
energy consumption, especially in old buildings. These challenges
include measurement and equipment costs, for example.
Additionally, the measurement results are difficult to interpret and
their usage in the ventilation control is also limited when taking into
account the energy efficiency of housing at the same time. The main
goal of this study is to develop a cost-effective building monitoring
and control system especially for old buildings. The starting point or
keyword of the development process is a wireless system; otherwise
the installation costs become too high. As the main result, this paper
describes an idea of a wireless building monitoring and control
system. The first prototype of the system has been installed in 10
residential buildings and in 10 school buildings located in the City of
Kuopio, Finland.
Abstract: The energy consumption and delay in read/write
operation of conventional SRAM is investigated analytically as well
as by simulation. Explicit analytical expressions for the energy
consumption and delay in read and write operation as a function of
device parameters and supply voltage are derived. The expressions are
useful in predicting the effect of parameter changes on the energy
consumption and speed as well as in optimizing the design of
conventional SRAM. HSPICE simulation in standard 0.25μm CMOS
technology confirms precision of analytical expressions derived from
this paper.
Abstract: One of the potential and effective ways of
storing thermal energy in buildings is the integration of brick with phase change materials (PCMs). This paper presents a two-dimensional model for simulating and analyzing of PCM
in order to minimize energy consumption in the buildings. The numerical approach has been used with the real weather data of a selected city of Iran (Tehran). Two kinds of brick integrated PCM are investigated and compared base on
outdoor weather conditions and the amount of energy
consumption. The results show a significant reduction in
maximum entering heat flux to building about 32.8%
depending on PCM quantity. The results are analyzed by
various temperature contour plots. The contour plots
illustrated the time dependent mechanism of entering heat flux for a brick integrated with PCM. Further analysis is developed to investigate the effect of PCM location on the inlet heat flux. The results demonstrated that to achieve maximum performance of PCM it is better to locate PCM near the outdoor.
Abstract: The purpose of this research was develop a biological
nutrient removal (BNR) system which has low energy consumption, sludge production, and land usage. These indicate that BNR system could be a alternative of future wastewater treatment in ubiquitous
city(U-city). Organics and nitrogen compounds could be removed by this system so that secondary or tertiary stages of wastewater treatment satisfy their standards. This system was composed of oxic and anoxic
filter filed with PVDC and POM media. Anoxic/oxic filter system operated under empty bed contact time of 4 hours by increasing
recirculation ratio from 0 to 100 %. The system removals of total nitrogen and COD were 76.3% and 93%, respectively. To be observed
internal behavior in this system SCOD, NH3-N, and NO3-N were
conducted and removal shows range of 25~100%, 59~99%, and
70~100%, respectively.