Abstract: Aiming the application of localized hyperthermia, a
magnetic induction system with new approaches is proposed. The techniques in this system for improving the effectiveness of localized hyperthermia are that using magnetic circuit and the multiple-coil array instead of a giant coil for generating magnetic field. Specially, amorphous metal is adopted as the material of magnetic circuit. Detail
design parameters of hardware are well described. Simulation tool is
employed for this work and experiment result is reported as well.
Abstract: Since polymerase chain reaction (PCR) has been
invented, it has emerged as a powerful tool in genetic analysis. The
PCR products are closely linked with thermal cycles. Therefore, to
reduce the reaction time and make temperature distribution uniform in
the reaction chamber, a novel oscillatory thermal cycler is designed.
The sample is placed in a fixed chamber, and three constant isothermal
zones are established and lined in the system. The sample is oscillated
and contacted with three different isothermal zones to complete
thermal cycles. This study presents the design of the geometric
characteristics of the chamber. The commercial software
CFD-ACE+TM is utilized to investigate the influences of various
materials, heating times, chamber volumes, and moving speed of the
chamber on the temperature distributions inside the chamber. The
chamber moves at a specific velocity and the boundary conditions
with time variations are related to the moving speed. Whereas the
chamber moves, the boundary is specified at the conditions of the
convection or the uniform temperature. The user subroutines compiled
by the FORTRAN language are used to make the numerical results
realistically. Results show that the reaction chamber with a rectangular
prism is heated on six faces; the effects of various moving speeds of
the chamber on the temperature distributions are examined. Regarding
to the temperature profiles and the standard deviation of the
temperature at the Y-cut cross section, the non-uniform temperature
inside chamber is found as the moving speed is larger than 0.01 m/s.
By reducing the heating faces to four, the standard deviation of the
temperature of the reaction chamber is under 1.4×10-3K with the range
of velocities between 0.0001 m/s and 1 m/s. The nature convective
boundary conditions are set at all boundaries while the chamber moves
between two heaters, the effects of various moving velocities of the
chamber on the temperature distributions are negligible at the assigned
time duration.
Abstract: The autonomic nervous system has a regulatory
structure that helps people adapt to changes in their environment by
adjusting or modifying some functions in response to stress, and regulating involuntary function of human organs. The purpose of this
study was to investigate the effect of combined stimulation, both
far-infrared heating and chiropractic, on the autonomic nervous system
activities using thermal image and heart rate variability. Six healthy subjects participated in this test. We compared the before and after
autonomic nervous system activities through obtaining thermal image
and photoplethysmogram signal. The thermal images showed that the
combined stimulation changed subject-s body temperature more
highly and widely than before. The result of heart rate variability
indicated that LF/HF ratio decreased. We concluded that combined
stimulation activates autonomic nervous system, and expected other
possibilities of this combined stimulation.
Abstract: The fabrication of porous NiTi shape memory alloys (SMAs) from elemental powder compacts was conducted by selfpropagating high temperature synthesis (SHS). Effects of the preheating temperature and the chamber pressure on the combustion characteristics as well as the final morphology and the composition of products were studied. The samples with porosity between 56.4 and 59.0% under preheating temperature in the range of 200-300°C and Ar-gas chamber pressure of 138 and 201 kPa were obtained. The pore structures were found to be dissimilar only in the samples processed with different preheating temperature. The major phase in the porous product is NiTi with small amounts of secondary phases, NiTi2 and Ni4Ti3. The preheating temperature and the chamber pressure have very little effect on the phase constituent. While the combustion temperature of the sample was notably increased by increasing the preheating temperature, they were slightly changed by varying the chamber pressure.
Abstract: In this paper an extensive verification of the extraction
method (published earlier) that consistently accounts for self-heating
and Early effect to accurately extract both base and thermal resistance
of bipolar junction transistors is presented. The method verification is
demonstrated on advanced RF SiGe HBTs were the extracted results
for the thermal resistance are compared with those from another
published method that ignores the effect of Early effect on internal
base-emitter voltage and the extracted results of the base resistance
are compared with those determined from noise measurements. A
self-consistency of our method in the extracted base resistance and
thermal resistance using compact model simulation results is also
carried out in order to study the level of accuracy of the method.
Abstract: Regarding previous research studies it was concluded
that thin-walled fiber-cement composites are able to conduct electric
current under specific conditions. This property is ensured by using
of various kinds of carbon materials. Though carbon fibers are less
conductive than metal fibers, composites with carbon fibers were
evaluated as better current conductors than the composites with metal
fibers. The level of electric conductivity is monitored by the means of
impedance measurement of designed samples. These composites
could be used for a range of applications such as heating of
trafficable surfaces or shielding of electro-magnetic fields.
The aim of the present research was to design an element with the
ability to monitor internal processes in building structures and
prevent them from collapsing. As a typical element for laboratory
testing there was chosen a concrete column, which was repeatedly
subjected to load by simple pressure with continual monitoring of
changes in electrical properties.
Abstract: To simulate heating systems in buildings, a research oriented computer code has been developed in Sharif University of Technology in Iran where the climate, existing heating equipment in buildings, consumer behavior and their interactions are considered for simulating energy consumption in conventional systems such as heaters, radiators and fan-coils. In order to validate the computer code, the available data of five buildings was used and the computed consumed energy was compared with the estimated energy extracted from monthly bills. The initial heating system was replaced by the alternative system and the effect of this change was observed on the energy consumption. As a result, the effect of changing heating equipment on energy consumption was investigated in different climates. Changing heater to radiator renders energy conservation up to 50% in all climates and changing radiator to fan-coil decreases energy consumption in climates with cold and dry winter.
Abstract: The onset of Marangoni convection in a horizontal
fluid layer with internal heat generation overlying a solid layer
heated from below is studied. The upper free surface of a fluid is
nondeformable and the bottom boundary are rigid and no-slip. The
resulting eigenvalue problem is solved exactly. The critical values of
the Marangoni numbers for the onset of Marangoni convection are
calculated and the latter is found to be critically dependent on the
internal heating, depth ratio and conductivity ratio. The effects of the
thermal conductivity and the thickness of the solid plate on the onset
of convective instability with internal heating are studied in detail.
Abstract: The substrate heater designed for this investigation is a front side substrate heating system. It consists of 10 conventional tungsten halogen lamps and an aluminum reflector, total input electrical power of 5 kW. The substrate is heated by means of a radiation from conventional tungsten halogen lamps directed to the substrate through a glass window. This design allows easy replacement of the lamps and maintenance of the system. Within 2 to 6 minutes the substrate temperature reaches 500 to 830 C by varying the vertical distance between the glass window and the substrate holder. Moreover, the substrate temperature can be easily controlled by controlling the input power to the system. This design gives excellent opportunity to deposit many deferent films at deferent temperatures in the same deposition time. This substrate heater was successfully used for Chemical Vapor Deposition (CVD) of many thin films, such as Silicon, iron, etc.
Abstract: Radiofrequency (RF) lesioning of nerves have been commonly used to alleviate chronic pain, where RF current preventing transmission of pain signals through the nerve by heating the nerve causing the pain. There are some factors that affect the temperature distribution and the nerve lesion size, one of these factors is the inhomogeneities in the tissue medium. Our objective is to calculate the temperature distribution and the nerve lesion size in an inhomogeneous medium surrounding the RF electrode. A two 3-D finite element models are used to compare the temperature distribution in the homogeneous and inhomogeneous medium. Also the effect of temperature-dependent electric conductivity on maximum temperature and lesion size is observed. Results show that the presence of an inhomogeneous medium around the RF electrode has a valuable effect on the temperature distribution and lesion size. The dependency of electric conductivity on tissue temperature increased lesion size.
Abstract: We successfully developed and tested a new
separation layer solving problems with unmanageable deposits inside the boilers of Zluticka Heating Plant. The deposits are mainly created
by glass-forming melts. We plotted straw ash compositions in K2OCaO-
SiO2 phase diagram and illustrated that they are in the area of low-melting eutectic points. To prevent the melting of ash and the
formation of deposits, we modified ash compositions by injecting additives into biomass fuel, and thus effectively suppressed deposits in a burner.
Abstract: The paper deals with determination of electromagnetic
and temperature field distribution of induction heating system used
for pipe brazing. The problem is considered as coupled – time
harmonic electromagnetic and transient thermal field. It has been
solved using finite element method. The detailed maps of
electromagnetic and thermal field distribution have been obtained.
The good understanding of the processes in the considered system
ensures possibilities for control, management and increasing the
efficiency of the welding process.
Abstract: When designing satellites, one of the major issues aside for designing its primary subsystems is to devise its thermal. The thermal management of satellites requires solving different sets of issues with regards to modelling. If the satellite is well conditioned all other parts of the satellite will have higher temperature no matter what. The main issue of thermal modelling for satellite design is really making sure that all the other points of the satellite will be within the temperature limits they are designed. The insertion of power electronics in aerospace technologies is becoming widespread and the modern electronic systems used in space must be reliable and efficient with thermal management unaffected by outer space constraints. Many advanced thermal management techniques have been developed in recent years that have application in high power electronic systems. This paper presents a Three-Dimensional Modal Transmission Line Matrix (3D-TLM) implementation of transient heat flow in space power electronics. In such kind of components heat dissipation and good thermal management are essential. Simulation provides the cheapest tool to investigate all aspects of power handling. The 3DTLM has been successful in modeling heat diffusion problems and has proven to be efficient in terms of stability and complex geometry. The results show a three-dimensional visualisation of self-heating phenomena in the device affected by outer space constraints, and will presents possible approaches for increasing the heat dissipation capability of the power modules.
Abstract: The manufacturing transmission line tower parts has
being generated hazardous waste which is required proper disposal
of waste for protection of land pollution. Manufacturing Process in
the manufacturing of steel angle, plates, pipes, channels are passes
through conventional, semi automatic and CNC machines for
cutting, marking, punching, drilling, notching, bending operations.
All fabricated material Coated with thin layer of Zinc in Galvanizing
plant where molten zinc is used for coating. Prior to Galvanizing,
chemical like 33% concentrated HCl Acid, ammonium chloride and
d-oil being used for pretreatment of iron. The bath of water with
sodium dichromate is used for cooling and protection of the
galvanized steel. For the heating purpose the furnace oil burners are
used. These above process the Zinc dross, Zinc ash, ETP sludge and
waste pickled acid generated as hazardous waste. The RPG has
made captive secured land fill site, since 1997 since then it was
using for disposal of hazardous waste after completion of SLF
(Secured land fill) site. The RPG has raised height from ground
level then now it is being used for disposal of waste as he designed
the SLF after in creasing height of from GL it is functional without
leach ate or adverse impacts in the environment.
Abstract: Nanocrystalline thin film of Na0.1V2O5.nH2O xerogel
obtained by sol gel synthesis was used as gas sensor. Gas sensing
properties of different gases such as hydrogen, petroleum and
humidity were investigated. Applying XRD and TEM the size of the
nanocrystals is found to be 7.5 nm. SEM shows a highly porous
structure with submicron meter-sized voids present throughout the
sample. FTIR measurement shows different chemical groups
identifying the obtained series of gels. The sample was n-type
semiconductor according to the thermoelectric power and electrical
conductivity. It can be seen that the sensor response curves from
130oC to 150oC show a rapid increase in sensitivity for all types of
gas injection, low response values for heating period and the rapid
high response values for cooling period. This result may suggest that
this material is able to act as gas sensor during the heating and
cooling process.
Abstract: Using the finite element analyses, this paper discusses the effects of temperature-dependent material properties on the stress and temperature fields in a cracked metal plate under the electric current load. The practical and complicated results are obtained when the temperature-dependent material properties are adopted in the analysis. If the simplified (temperature-independent) material properties are used, incorrect results will be obtained.
Abstract: In order to compare the performance of the carbon dioxide and HFC-125 heat pumps for medium-and high-temperature heating, both heat pump cycles were optimized using a simulation method. To fairly compare the performance of the cycles by using different working fluids, each cycle was optimized from the viewpoint of heating COP by two design parameters. The first is the gas cooler exit temperature and the other is the ratio of the overall heat conductance of the gas cooler to the combined overall heat conductance of the gas cooler and the evaporator. The inlet and outlet temperatures of secondary fluid of the gas cooler were fixed at 40/90°C and 40/150°C.The results shows that the HFC-125 heat pump has 6% higher heating COP than carbon dioxide heat pump when the heat sink exit temperature is fixed at 90ºC, while the latter outperforms the former when the heat sink exit temperature is fixed at 150ºC under the simulation conditions considered in the present study.
Abstract: Heating systems are a necessity for regions which
brace extreme cold weather throughout the year. To maintain a comfortable temperature inside a given place, heating systems
making use of- Hydronic boilers- are used. The principle of a single
pipe system serves as a base for their working. It is mandatory for these heating systems to control the room temperature, thus
maintaining a warm environment. In this paper, the concept of regulation of the room temperature over a wide range is established
by using an Adaptive Fuzzy Controller (AFC). This fuzzy controller automatically detects the changes in the outside temperatures and
correspondingly maintains the inside temperature to a palatial value. Two separate AFC's are put to use to carry out this function: one to
determine the quantity of heat needed to reach the prospective temperature required and to set the desired temperature; the other to control the position of the valve, which is directly proportional to the
error between the present room temperature and the user desired temperature. The fuzzy logic controls the position of the valve as per
the requirement of the heat. The amount by which the valve opens or closes is controlled by 5 knob positions, which vary from minimum to maximum, thereby regulating the amount of heat flowing through the valve. For the given test system data, different de-fuzzifier
methods have been implemented and the results are compared. In order to validate the effectiveness of the proposed approach, a fuzzy controller has been designed by obtaining a test data from a real time
system. The simulations are performed in MATLAB and are verified with standard system data. The proposed approach can be implemented for real time applications.
Abstract: Non-uniform current distribution in polymer
electrolyte membrane fuel cells results in local over-heating,
accelerated ageing, and lower power output than expected. This
issue is very critical when fuel cell experiences water flooding. In
this work, the performance of a PEM fuel cell is investigated under
cathode flooding conditions. Two-dimensional partially flooded
GDL models based on the conservation laws and electrochemical
relations are proposed to study local current density distributions
along flow fields over a wide range of cell operating conditions.
The model results show a direct association between cathode inlet
humidity increases and that of average current density but the
system becomes more sensitive to flooding. The anode inlet
relative humidity shows a similar effect. Operating the cell at
higher temperatures would lead to higher average current densities
and the chance of system being flooded is reduced. In addition,
higher cathode stoichiometries prevent system flooding but the
average current density remains almost constant. The higher anode
stoichiometry leads to higher average current density and higher
sensitivity to cathode flooding.
Abstract: The increasing demand for sufficient and clean
energy forces industrial and service companies to align their strategies towards efficient consumption. This trend refers also to the
residential building sector. There, large amounts of energy consumption are caused by house and facility heating. Many of the
operated hot water heating systems lack hydraulic balanced working
conditions for heat distribution and –transmission and lead to
inefficient heating. Through hydraulic balancing of heating systems,
significant energy savings for primary and secondary energy can be
achieved. This paper addresses the use of KNX-technology (Smart
Buildings) in residential buildings to ensure a dynamic adaption of
hydraulic system's performance, in order to increase the heating
system's efficiency. In this paper, the procedure of heating system
segmentation into hydraulically independent units (meshes) is
presented. Within these meshes, the heating valve are addressed and
controlled by a central facility server. Feasibility criteria towards
such drivers will be named. The dynamic hydraulic balance is
achieved by positioning these valves according to heating loads, that
are generated from the temperature settings in the corresponding
rooms. The energetic advantages of single room heating control
procedures, based on the application FacilityManager, is presented.