Abstract: In this paper a polymer electrolyte membrane (PEM)
fuel cell power system including burner, steam reformer, heat
exchanger and water heater has been considered to meet the
electrical, heating, cooling and domestic hot water loads of
residential building which in Tehran. The system uses natural gas as
fuel and works in CHP mode. Design and operating conditions of a
PEM fuel cell system is considered in this study. The energy
requirements of residential building and the number of fuel cell
stacks to meet them have been estimated. The method involved
exergy analysis and entropy generation thorough the months of the
year. Results show that all the energy needs of the building can be
met with 12 fuel cell stacks at a nominal capacity of 8.5 kW. Exergy
analysis of the CHP system shows that the increase in the ambient air
temperature from 1oC to 40oC, will have an increase of entropy
generation by 5.73%.Maximum entropy generates for 15 hour in 15th
of June and 15th of July is estimated to amount at 12624 (kW/K).
Entropy generation of this system through a year is estimated to
amount to 1004.54 GJ/k.year.
Abstract: Utilization of bagasse ash for silica sources is one of
the most common application for agricultural wastes and valuable
biomass byproducts in sugar milling. The high percentage silica
content from bagasse ash was used as silica source for sodium
silicate solution. Different heating temperature, time and acid
treatment were studies for silica extraction. The silica was
characterized using various techniques including X-ray fluorescence,
X-ray diffraction, Scanning electron microscopy, and Fourier
Transform Infrared Spectroscopy method,. The synthesis conditions
were optimized to obtain the bagasse ash with the maximum silica
content. The silica content of 91.57 percent was achieved from
heating of bagasse ash at 600°C for 3 hours under oxygen feeding
and HCl treatment. The result can be used as value added for bagasse
ash utilization and minimize the environmental impact of disposal
problems.
Abstract: This research was conducted to develop a correlation
between microstructure of HSLA steel and the mechanical properties
that occur as a result of both laser and mechanical forming processes
of the metal. The technique of forming flat metals by applying laser
beams is a relatively new concept in the manufacturing industry.
However, the effects of laser energy on the stability of metal alloy
phases have not yet been elucidated in terms of phase
transformations and microhardness. In this work, CO2 laser source
was used to irradiate the surface of a flat metal then the
microstructure and microhardness of the metal were studied on the
formed specimen. The extent to which the microstructure changed
depended on the heat inputs of up to 1000 J/cm2 with cooling rates of
about 4.8E+02 K/s. Experimental results revealed that the irradiated
surface of a HSLA steel had transformed to austenitic structure
during the heating process.
Abstract: In this study, multiwall carbon nanotubes (MWNTs)
were modified with nitric acid chemically and by dielectric barrier
discharge (DBD) plasma in an oxygen-based atmosphere. Used
carbon nanotubes (CNTs) were prepared by chemical vapour
deposition (CVD) floating catalyst method. For removing amorphous
carbon and metal catalyst, MWNTs were exposed to dry air and
washed with hydrochloric acid. Heating purified CNTs under helium
atmosphere caused elimination of acidic functional groups. Fourier
transformed infrared spectroscopy (FTIR) shows formation of
oxygen containing groups such as C=O and COOH. Brunauer,
Emmett, Teller (BET) analysis revealed that functionalization causes
generation of defects on the sidewalls and opening of the ends of
CNTs. Results of temperature-programmed desorption (TPD) and gas
chromatography(GC) indicate that nitric acid treatment create more
acidic groups than plasma treatment.
Abstract: Power transformer consists of components which are
under consistent thermal and electrical stresses. The major
component which degrades under these stresses is the paper
insulation of the power transformer. At site, lightning impulses and
cable faults may cause the winding deformation. In addition, the
winding may deform due to impact during transportation. A
deformed winding will excite more stress to its insulating paper thus
will degrade it. Insulation degradation will shorten the life-span of
the transformer. Currently there are two methods of detecting the
winding deformation which are Sweep Frequency Response
Analysis (SFRA) and Low Voltage Impulse Test (LVI). The latter
injects current pulses to the winding and capture the admittance
plot. In this paper, a transformer which experienced overheating and
arcing was identified, and both SFRA and LVI were performed.
Next, the transformer was brought to the factory for untanking. The
untanking results revealed that the LVI is more accurate than the
SFRA method for this case study.
Abstract: This paper presents the study of hardness profile of spur gear heated by induction heating process in function of the machine parameters, such as the power (kW), the heating time (s) and the generator frequency (kHz). The global work is realized by 3D finite-element simulation applied to the process by coupling and resolving the electromagnetic field and the heat transfer problems, and it was performed in three distinguished steps. First, a Comsol 3D model was built using an adequate formulation and taking into account the material properties and the machine parameters. Second, the convergence study was conducted to optimize the mesh. Then, the surface temperatures and the case depths were deeply analyzed in function of the initial current density and the heating time in medium frequency (MF) and high frequency (HF) heating modes and the edge effect were studied. Finally, the simulations results are validated using experimental tests.
Abstract: The UK Government has emphasized the role of Local Authorities as a key player in its flagship residential energy efficiency strategies, by identifying and targeting areas for energy efficiency improvements. Residential energy consumption in England is characterized by significant geographical variation in energy demand, which makes centralized targeting of areas for energy efficiency intervention difficult. This paper draws on research which aims to understand how demographic, social, economic, urban form and climatic factors influence the geographical variations in English residential gas consumption. The paper reports the findings of a multiple regression model that shows how 64% of the geographical variation in residential gas consumption is accounted for by variations in these factors. Results from this study, after further refinement and validation, can be used by Local Authorities to identify areas within their boundaries that have higher than expected gas consumption, these may be prime targets for energy efficiency initiatives.
Abstract: The waverider is proved to be a remarkably useful
configuration for hypersonic glide vehicle (HGV) in terms of the high
lift-to-drag ratio. Due to the severe aerodynamic heating and the
processing technical restriction, the sharp leading edge of waverider
should be blunted, and then the flow characteristics and the
aerodynamic performance along the trajectory will change. In this
paper, the flow characteristics of a HGV, including the rarefied gas
effect and transition phenomenon, were studied based on a reference
trajectory. A numerical simulation was carried out to study the
performance of the HGV under a typical condition.
Abstract: The paper provides biomasses characteristics by
proximate analysis (volatile matter, fixed carbon and ash) and
ultimate analysis (carbon, hydrogen, nitrogen and oxygen) for the
prediction of the heating value equations. The heating value
estimation of various biomasses can be used as an energy evaluation.
Thirteen types of biomass were studied. Proximate analysis was
investigated by mass loss method and infrared moisture analyzer.
Ultimate analysis was analyzed by CHNO analyzer. The heating
values varied from 15 to 22.4MJ kg-1. Correlations of the calculated
heating value with proximate and ultimate analyses were undertaken
using multiple regression analysis and summarized into three and two
equations, respectively. Correlations based on proximate analysis
illustrated that deviation of calculated heating values from
experimental heating values was higher than the correlations based
on ultimate analysis.
Abstract: A group of Stellite alloys are studied in consideration
of temperature effects on their hardness and wear resistance. The
hardness test is conducted on a micro-hardness tester with a hot stage
equipped that allows heating the specimen up to 650°C. The wear
resistance of each alloy is evaluated using a pin-on-disc tribometer
with a heating furnace built-in that provides the temperature capacity
up to 450°C. The experimental results demonstrate that the hardness
and wear resistance of Stellite alloys behave differently at room
temperature and at high temperatures. The wear resistance of Stellite
alloys at room temperature mainly depends on their carbon content and
also influenced by the tungsten content in the alloys. However, at high
temperatures the wear mechanisms of Stellite alloys become more
complex, involving multiple factors. The relationships between
chemical composition, microstructure, hardness and wear resistance of
these alloys are studied, with focus on temperature effect on these
relations.
Abstract: The objective of this paper is to present a research
study of the convectors that are used for heating or cooling of the
living room or industrial halls. The key points are experimental
measurement and comprehensive numerical simulation of the flow
coming throughout the part of the convector such as heat exchanger,
input from the fan etc.. From the obtained results, the components of
the convector are optimized in sense to increase thermal power
efficiency due to improvement of heat convection or reduction of air
drag friction. Both optimized aspects are leading to the more
effective service conditions and to energy saving. The significant part
of the convector research is a design of the unique measurement
laboratory and adopting measure techniques. The new laboratory
provides possibility to measure thermal power efficiency and other
relevant parameters under specific service conditions of the
convectors.
Abstract: Coal fly ash (CFA) generated by coal-based thermal
power plants is mainly composed of quartz, mullite, and unburned
carbon. In this study, the effect of unburned carbon on CFA toward
its adsorption capacity was investigated. CFA with various carbon
content was obtained by refluxing it with sulfuric acid having various
concentration at various temperature and reflux time, by heating at
400-800°C, and by sieving into 100-mesh in particle size. To
evaluate the effect of unburned carbon on CFA toward its adsorption
capacity, adsorption of methyl violet solution with treated CFA was
carried out. The research shows that unburned carbon leads to
adsorption capacity decrease. The highest adsorption capacity of
treated CFA was found 5.73 x 10-4mol.g-1.
Abstract: This paper presents the results of the preliminary investigation of microwave (MW) irradiation pretreatments on the anaerobic digestion of food residues using biochemical methane potential (BMP) assays. Low solids systems with a total solids (TS) content ranging from 5.0-10.0% were analyzed. The inoculum to bulk mass of substrates to water ratio was 1:2:2 (mass basis). The experimental conditions for pretreatments were as follows: a control (no MW irradiation), two runs with MW irradiation for 15 and 30 minutes at 320 W, and another two runs with MW irradiation at 528 W for 30 and 60 minutes. The cumulative biogas production were 6.3 L and 8.7 L for 15min/320 W and 30min/320 W MW irradiation conditions, respectively, and 10.5 L and 11.4 L biogas for 30min/528 W and 60min/528 W, respectively, as compared to the control giving 5.8 L biogas. Both an increase in exposure time of irradiation and power of MW had increased the rate and yield of biogas. Singlefactor ANOVA tests (p
Abstract: This paper presented a modified efficient inductive
powering link based on ASK modulator and proposed efficient class-
E power amplifier. The design presents the external part which is
located outside the body to transfer power and data to the implanted
devices such as implanted Microsystems to stimulate and monitoring
the nerves and muscles. The system operated with low band
frequency 10MHZ according to industrial- scientific – medical (ISM)
band to avoid the tissue heating. For external part, the modulation
index is 11.1% and the modulation rate 7.2% with data rate 1 Mbit/s
assuming Tbit = 1us. The system has been designed using 0.35-μm
fabricated CMOS technology. The mathematical model is given and
the design is simulated using OrCAD P Spice 16.2 software tool and
for real-time simulation, the electronic workbench MULISIM 11 has
been used.
Abstract: Chemical detection is still a continuous challenge when
it comes to designing single-walled carbon nanotube (SWCNT)
sensors with high selectivity, especially in complex chemical
environments. A perfect example of such an environment would be in
thermally oxidized soybean oil. At elevated temperatures, oil oxidizes
through a series of chemical reactions which results in the formation of
monoacylglycerols, diacylglycerols, oxidized triacylglycerols, dimers,
trimers, polymers, free fatty acids, ketones, aldehydes, alcohols,
esters, and other minor products. In order to detect the rancidity of
oxidized soybean oil, carbon nanotube chemiresistor sensors have
been coated with polyethylenimine (PEI) to enhance the sensitivity
and selectivity. PEI functionalized SWCNTs are known to have a high
selectivity towards strong electron withdrawing molecules. The
sensors were very responsive to different oil oxidation levels and
furthermore, displayed a rapid recovery in ambient air without the
need of heating or UV exposure.
Abstract: Team distillation assisted by microwave extraction
(SDAM) considered as accelerated technique extraction is a
combination of microwave heating and steam distillation, performed
at atmospheric pressure. SDAM has been compared with the same
technique coupled with the cryogrinding of seeds (SDAM -CG).
Isolation and concentration of volatile compounds are performed by a
single stage for the extraction of essential oil from Cuminum
cyminum seeds. The essential oils extracted by these two methods for
5 min were quantitatively (yield) and qualitatively (aromatic profile)
no similar. These methods yield an essential oil with higher amounts
of more valuable oxygenated compounds, and allow substantial
savings of costs, in terms of time, energy and plant material. SDAM
and SDAM-CG is a green technology and appears as a good
alternative for the extraction of essential oils from aromatic plants.
Abstract: To simulate heating systems in buildings, a research oriented computer code has been developed in Sharif University of Technology in Iran where the climate, existing heating equipment in buildings, consumer behavior and their interactions are considered for simulating energy consumption in conventional systems such as heaters, radiators and fan-coils. In order to validate the computer code, the available data of five buildings was used and the computed consumed energy was compared with the estimated energy extracted from monthly bills. The initial heating system was replaced by the alternative system and the effect of this change was observed on the energy consumption. As a result, the effect of changing heating equipment on energy consumption was investigated in different climates. Changing heater to radiator renders energy conservation up to 50% in all climates and changing radiator to fan-coil decreases energy consumption in climates with cold and dry winter.
Abstract: The present study is aim to prepare and evaluate the selfnanoemulsifying drug delivery (SNEDDS) system of a poorly water soluble drug valsartan in order to achieve a better dissolution rate which would further help in enhancing oral bioavailability. The present research work describes a SNEDDS of valsartan using labrafil M 1944 CS, Tween 80 and Transcutol HP. The pseudoternary phase diagrams with presence and absence of drug were plotted to check for the emulsification range and also to evaluate the effect of valsartan on the emulsification behavior of the phases. The mixtures consisting of oil (labrafil M 1944 CS) with surfactant (tween 80), co-surfactant (Transcutol HP) were found to be optimum formulations. Prepared formulations were evaluated for its particle size distribution, nanoemulsifying properties, robustness to dilution, self emulsication time, turbidity measurement, drug content and invitro dissolution. The optimized formulations are further evaluated for heating cooling cycle, centrifugation studies, freeze thaw cycling, particle size distribution and zeta potential were carried out to confirm the stability of the formed SNEDDS formulations. The prepared formulation revealed t a significant improvement in terms of the drug solubility as compared with marketed tablet and pure drug.
Abstract: Heating is inevitable in any bearing operation. This
leads to not only the thinning of the lubricant but also could lead to a
thermal deformation of the bearing. The present work is an attempt to
analyze the influence of thermal deformation on the thermohydrodynamic
lubrication of infinitely long tilted pad slider rough
bearings. As a consequence of heating the slider is deformed and is
assumed to take a parabolic shape. Also the asperities expand leading
to smaller effective film thickness. Two different types of surface
roughness are considered: longitudinal roughness and transverse
roughness. Christensen-s stochastic approach is used to derive the
Reynolds-type equations. Density and viscosity are considered to be
temperature dependent. The modified Reynolds equation, momentum
equation, continuity equation and energy equation are decoupled and
solved using finite difference method to yield various bearing
characteristics. From the numerical simulations it is observed that the
performance of the bearing is significantly affected by the thermal
distortion of the slider and asperities and even the parallel sliders
seem to carry some load.
Abstract: A CFD study on heat flux reduction in hypersonic flow with opposing jet has been conducted. Flowfield parameters, reattachment point position, surface pressure distributions and heat flux distributions are obtained and validated with experiments. The physical mechanism of heat reduction has been analyzed. When the opposing jet blows, the freestream is blocked off, flows to the edges and not interacts with the surface to form aerodynamic heating. At the same time, the jet flows back to form cool recirculation region, which reduces the difference in temperature between the surface and the nearby gas, and then reduces the heat flux. As the pressure ratio increases, the interface between jet and freestream is gradually pushed away from the surface. Larger the total pressure ratio is, lower the heat flux is. To study the effect of the intensity of opposing jet more reasonably, a new parameter RPA has been introduced by combining the flux and the total pressure ratio. The study shows that the same shock wave position and total heat load can be obtained with the same RPA with different fluxes and the total pressures, which means the new parameter could stand for the intensity of opposing jet and could be used to analyze the influence of opposing jet on flow field and aerodynamic heating.