Abstract: A novel and efficient approach to realize
fractional-order capacitors is investigated in this paper. Meanwhile, a
new approach which is more efficient for semiconductor
implementation of fractional-order capacitors is proposed. The
feasibility of the approach has been verified with the preliminary
measured results.
Abstract: Performance of vehicle depends on driving patterns
and vehicle drive train configuration. Driving patterns depends on
traffic condition, road condition and driver behavior. HEV design is
carried out under certain constrain like vehicle operating range,
acceleration, decelerations, maximum speed and road grades which
are directly related to the driving patterns. Therefore the detailed
study on HEV performance over a different drive cycle is required
for selection and sizing of HEV components. A simple hardware is
design to measured velocity v/s time profile of the vehicle by
operating vehicle on Indian roads under real traffic conditions. To
size the HEV components, a detailed dynamic model of the vehicle is
developed considering the effect of inertia of rotating components
like wheels, drive chain, engine and electric motor. Using vehicle
model and different Indian drive cycles data, total tractive power
demanded by vehicle and power supplied by individual components
has been calculated.Using above information selection and estimation
of component sizing for HEV is carried out so that HEV performs
efficiently under hostile driving condition. Complete analysis is
carried out in LABVIEW.
Abstract: Voltage stability has become an important issue to many power systems around the world due to the weak systems and long line on power system networks. In this paper, MATLAB load flow program is applied to obtain the weak points in the system combined with finding the voltage stability limit. The maximum permissible loading of a system, within the voltage stability limit, is usually determined. The methods for varying tap ratio (using tap changing transformer) and applying different values of shunt capacitor injection to improve the voltage stability within the limit are also provided.
Abstract: A high precision temperature insensitive current and voltage reference generator is presented. It is specifically developed for temperature compensated oscillator. The circuit, designed using MXIC 0.5um CMOS technology, has an operating voltage that ranges from 2.6V to 5V and generates a voltage of 1.21V and a current of 6.38 ӴA. It exhibits a variation of ±0.3nA for the current reference and a stable output for voltage reference as the temperature is varied from 0°C to 70°C. The power supply rejection ratio obtained without any filtering capacitor at 100Hz and 10MHz is -30dB and -12dB respectively.
Abstract: In contrast to conventional generators, self-excited induction generators are found to be most suitable machines for wind energy conversion in remote and windy areas due to many advantages over grid connected machines. This papers presents a Self-Excited Induction Generator (SEIG) driven by wind turbine and supplying an induction motor which is coupled to a centrifugal pump. A method to describe the steady state performance based on nodal analysis is presented. Therefore the advanced knowledge of the minimum excitation capacitor value is required. The effects of variation of excitation capacitance on system and rotor speed under different loading conditions have been analyzed and considered to optimize induction motor pump performances.
Abstract: In this paper, a technique is proposed to implement
an artificial voltage-controlled capacitance or inductance which can
replace the well-known varactor diode in many applications. The
technique is based on injecting the current of a voltage-controlled
current source onto a fixed capacitor or inductor. Then, by controlling
the transconductance of the current source by an external bias voltage,
a voltage-controlled capacitive or inductive reactance is obtained.
The proposed voltage-controlled reactance devices can be designed
to work anywhere in the frequency spectrum. Practical circuits for the
proposed voltage-controlled reactances are suggested and simulated.
Abstract: An electric power system includes a generating, a
transmission, a distribution, and consumers subsystems. An electrical
power network in Tanzania keeps growing larger by the day and
become more complex so that, most utilities have long wished for
real-time monitoring and remote control of electrical power system
elements such as substations, intelligent devices, power lines,
capacitor banks, feeder switches, fault analyzers and other physical
facilities. In this paper, the concept of automation of management of
power systems from generation level to end user levels was
determined by using Power System Simulator for Engineering
(PSS/E) version 30.3.2.
Abstract: Three similar negative differential resistance (NDR)
profiles with both high peak to valley current density ratio (PVCDR)
value and high peak current density (PCD) value in unity resonant
tunneling electronic circuit (RTEC) element is developed in this paper.
The PCD values and valley current density (VCD) values of the three
NDR curves are all about 3.5 A and 0.8 A, respectively. All PV values
of NDR curves are 0.40 V, 0.82 V, and 1.35 V, respectively. The VV
values are 0.61 V, 1.07 V, and 1.69 V, respectively. All PVCDR
values reach about 4.4 in three NDR curves. The PCD value of 3.5 A
in triple PVCDR RTEC element is better than other resonant
tunneling devices (RTD) elements. The high PVCDR value is
concluded the lower VCD value about 0.8 A. The low VCD value is
achieved by suitable selection of resistors in triple PVCDR RTEC
element. The low PV value less than 1.35 V possesses low power
dispersion in triple PVCDR RTEC element. The designed multiple
value logical level (MVLL) system using triple PVCDR RTEC
element provides equidistant logical level. The logical levels of
MVLL system are about 0.2 V, 0.8 V, 1.5 V, and 2.2 V from low
voltage to high voltage and then 2.2 V, 1.3 V, 0.8 V, and 0.2 V from
high voltage back to low voltage in half cycle of sinusoid wave. The
output level of four levels MVLL system is represented in 0.3 V, 1.1 V,
1.7 V, and 2.6 V, which satisfies the NMP condition of traditional
two-bit system. The remarkable logical characteristic of improved
MVLL system with paralleled capacitor are with four significant
stable logical levels about 220 mV, 223 mV, 228 mV, and 230 mV.
The stability and articulation of logical levels of improved MVLL
system are outstanding. The average holding time of improved MVLL
system is approximately 0.14 μs. The holding time of improved
MVLL system is fourfold than of basic MVLL system. The function of
additional capacitor in the improved MVLL system is successfully
discovered.
Abstract: In this paper optimal capacitor placement problem has
been formulated in a restructured distribution network. In this
scenario the distribution network operator can consider reactive
energy also as a service that can be sold to transmission system. Thus
search for optimal location, size and number of capacitor banks with
the objective of loss reduction, maximum income from selling
reactive energy to transmission system and return on investment for
capacitors, has been performed. Results is influenced with economic
value of reactive energy, therefore problem has been solved for
various amounts of it. The implemented optimization technique is
genetic algorithm. For any value of reactive power economic value,
when reverse of investment index increase and change from zero or
negative values to positive values, the threshold value of selling
reactive power has been obtained. This increasing price of economic
parameter is reasonable until the network losses is less than loss
before compensation.
Abstract: Micro power sources are required to be used in autonomous microelectromechanical system (MEMS). In this paper,
we designed and fabricated a three dimensional (3D) MEMS supercapacitor, which is consisting of conformal silicon
dioxide/titanium/polypyrrole (PPy) layers on silicon substrate. At first, ''through-structure'' was fabricated on the silicon substrate by high-aspect-ratio deep reactive ion etching (DRIE) method, which enlarges the available surface area significantly. Then the SiO2/Ti/PPy layers grew sequentially on the ³through-structure´. Finally, the supercapacitor was investigated by electrochemical methods.
Abstract: Improving the reactive power and voltage profile of a
distribution substation is investigated in this paper. The purpose is to
properly determination of the shunt capacitors on/off status and
suitable tap changer (TC) position of a substation transformer. In
addition, the limitation of secondary bus voltage, the maximum
allowable number of switching operation in a day for on load tap
changer and on/off status of capacitors are taken into account. To
achieve these goals, an artificial neural network (ANN) is designed to
provide preliminary scheduling. Input of ANN is active and reactive
powers of transformer and its primary and secondary bus voltages.
The output of ANN is capacitors on/off status and TC position. The
preliminary schedule is further refined by fuzzy dynamic
programming in order to reach the final schedule. The operation of
proposed method in Q/V improving is compared with the results
obtained by operator operation in a distribution substation.
Abstract: This paper presents a new and efficient approach for capacitor placement in radial distribution systems that determine the optimal locations and size of capacitor with an objective of improving the voltage profile and reduction of power loss. The solution methodology has two parts: in part one the loss sensitivity factors are used to select the candidate locations for the capacitor placement and in part two a new algorithm that employs Plant growth Simulation Algorithm (PGSA) is used to estimate the optimal size of capacitors at the optimal buses determined in part one. The main advantage of the proposed method is that it does not require any external control parameters. The other advantage is that it handles the objective function and the constraints separately, avoiding the trouble to determine the barrier factors. The proposed method is applied to 9, 34, and 85-bus radial distribution systems. The solutions obtained by the proposed method are compared with other methods. The proposed method has outperformed the other methods in terms of the quality of solution.
Abstract: Most of the losses in a power system relate to
the distribution sector which always has been considered.
From the important factors which contribute to increase losses
in the distribution system is the existence of radioactive flows.
The most common way to compensate the radioactive power
in the system is the power to use parallel capacitors. In
addition to reducing the losses, the advantages of capacitor
placement are the reduction of the losses in the release peak of
network capacity and improving the voltage profile. The point
which should be considered in capacitor placement is the
optimal placement and specification of the amount of the
capacitor in order to maximize the advantages of capacitor
placement.
In this paper, a new technique has been offered for the
placement and the specification of the amount of the constant
capacitors in the radius distribution network on the basis of
Genetic Algorithm (GA). The existing optimal methods for
capacitor placement are mostly including those which reduce
the losses and voltage profile simultaneously. But the
retaliation cost and load changes have not been considered as
influential UN the target function .In this article, a holistic
approach has been considered for the optimal response to this
problem which includes all the parameters in the distribution
network: The price of the phase voltage and load changes. So,
a vast inquiry is required for all the possible responses. So, in
this article, we use Genetic Algorithm (GA) as the most
powerful method for optimal inquiry.
Abstract: This paper presents a new method which applies an
artificial bee colony algorithm (ABC) for capacitor placement in
distribution systems with an objective of improving the voltage profile
and reduction of power loss. The ABC algorithm is a new population
based meta heuristic approach inspired by intelligent foraging behavior
of honeybee swarm. The advantage of ABC algorithm is that
it does not require external parameters such as cross over rate and
mutation rate as in case of genetic algorithm and differential evolution
and it is hard to determine these parameters in prior. The other
advantage is that the global search ability in the algorithm is implemented
by introducing neighborhood source production mechanism
which is a similar to mutation process. To demonstrate the validity
of the proposed algorithm, computer simulations are carried out on
69-bus system and compared the results with the other approach
available in the literature. The proposed method has outperformed the
other methods in terms of the quality of solution and computational
efficiency.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.
Abstract: This paper presents an efficient algorithm for
optimization of radial distribution systems by a network
reconfiguration to balance feeder loads and eliminate overload
conditions. The system load-balancing index is used to determine the
loading conditions of the system and maximum system loading
capacity. The index value has to be minimum in the optimal network
reconfiguration of load balancing. A method based on Tabu search
algorithm, The Tabu search algorithm is employed to search for the
optimal network reconfiguration. The basic idea behind the search is
a move from a current solution to its neighborhood by effectively
utilizing a memory to provide an efficient search for optimality. It
presents low computational effort and is able to find good quality
configurations. Simulation results for a radial 69-bus system with
distributed generations and capacitors placement. The study results
show that the optimal on/off patterns of the switches can be identified
to give the best network reconfiguration involving balancing of
feeder loads while respecting all the constraints.
Abstract: With the rapid advanced of technology, the industrial processes become increasingly demanding, from the point of view, power quality and controllability. The advent of multi levels inverters responds partially to these requirements. But actually, the new generation of multi-cells inverters permits to reach more performances, since, it offers more voltage levels. The disadvantage in the increase of voltage levels by the number of cells in cascades is on account of series igbts synchronisation loss, from where, a limitation of cells in cascade to 4. Regarding to these constraints, a new topology is proposed in this paper, which increases the voltage levels of the three-cell inverter from 4 to 8; with the same number of igbts, and using less stored energy in the flaying capacitors. The details of operation and modelling of this new inverter structure are also presented, then tested thanks to a three phase induction motor. KeywordsFlaying capacitors, Multi-cells inverter, pwm, switchers, modelling.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: This paper presents the design of a low power second-order continuous-time sigma-delta modulator for low power
applications. The loop filter of this modulator has been implemented based on the nonlinear transconductance-capacitor (Gm-C) by employing current-mode technique. The nonlinear transconductance uses floating gate MOS (FG-MOS) transistors that operate in weak inversion region. The proposed modulator features low power consumption (
Abstract: There are a many of needs for the development of
SiC-based hydrogen sensor for harsh environment applications. We
fabricated and investigated Pd/Ta2O5/SiC-based hydrogen sensors
with MOS capacitor structure for high temperature process monitoring
and leak detection applications in such automotive, chemical and
petroleum industries as well as direct monitoring of combustion
processes. In this work, we used silicon carbide (SiC) as a substrate to
replace silicon which operating temperatures are limited to below
200°C. Tantalum oxide was investigated as dielectric layer which has
high permeability for hydrogen gas and high dielectric permittivity,
compared with silicon dioxide or silicon nitride. Then, electrical
response properties, such as I-V curve and dependence of capacitance
on hydrogen concentrations were analyzed in the temperature ranges
of room temperature to 500°C for performance evaluation of the
sensor.