Abstract: This paper presents preference programming technique based multiple criteria decision making analysis for selecting a facility location for a new organization or expansion of an existing facility which is of vital importance for a decision support system and strategic planning process. The implementation of decision support systems is considered crucial to sustain competitive advantage and profitability persistence in turbulent environment. As an effective strategic management and decision making is necessary, multiple criteria decision making analysis supports the decision makers to formulate and implement the right strategy. The investment cost associated with acquiring the property and facility construction makes the facility location selection problem a long-term strategic investment decision, which rationalize the best location selection which results in higher economic benefits through increased productivity and optimal distribution network. Selecting the proper facility location from a given set of alternatives is a difficult task, as many potential qualitative and quantitative multiple conflicting criteria are to be considered. This paper solves a facility location selection problem using preference programming, which is an effective multiple criteria decision making analysis tool applied to deal with complex decision problems in the operational research environment. The ranking results of preference programming are compared with WSM, TOPSIS and VIKOR methods.
Abstract: The deployment of smart grid devices such as smart meters and smart switches (SS) supported by a reliable and fast communications system makes automated distribution possible, and thus, provides great benefits to electric power consumers and providers alike. However, more research is needed before the full utility of smart switch data is realized. This paper presents new automated switching techniques using SS within the electric power grid. A concise background of the SS is provided, and operational examples are shown. Organization and presentation of data obtained from SS are shown in the context of the future goal of total automation of the distribution network. The description of application techniques, the examples of success with SS, and the vision outlined in this paper serve to motivate future research pertinent to disturbance analysis automation.
Abstract: The use of more and more electronic power switches with a nonlinear behavior generates non-sinusoidal currents in distribution networks, which causes damage to domestic and industrial equipment. The multi-level shunt power active filter is subsequently shown to be an adequate solution to the problem raised. Nevertheless, the difficulty of adjusting the active filter DC supply voltage requires another technology to ensure it. In this article, a photovoltaic generator is associated with the DC bus power terminals of the active filter. The proposed system consists of a field of solar panels, three multi-level voltage inverters connected to the power grid and a non-linear load consisting of a six-diode rectifier bridge supplying a resistive-inductive load. Current control techniques of active and reactive power are used to compensate for both harmonic currents and reactive power as well as to inject active solar power into the distribution network. An algorithm of the search method of the maximum power point of type Perturb and observe is applied. Simulation results of the system proposed under the MATLAB/Simulink environment shows that the performance of control commands that reassure the solar power injection in the network, harmonic current compensation and power factor correction.
Abstract: The installation of photovoltaic based distributed generation (PVDG) in active distribution system can lead to voltage fluctuation due to the intermittent and unpredictable PVDG output power. This paper presented a method in mitigating the voltage rise by optimally locating and sizing the battery energy storage system (BESS) in PVDG integrated distribution network. The improved firefly algorithm is used to perform optimal placement and sizing. Three objective functions are presented considering the voltage deviation and BESS off-time with state of charge as the constraint. The performance of the proposed method is compared with another optimization method such as the original firefly algorithm and gravitational search algorithm. Simulation results show that the proposed optimum BESS location and size improve the voltage stability.
Abstract: During the recent past, due to the increase of electrical energy demand and governmental resources constraints in creating additional capacity in the generation, transmission, and distribution, privatization, and restructuring in electrical industry have been considered. So, in most of the countries, different parts of electrical industry like generation, transmission, and distribution have been separated in order to create competition. Considering these changes, environmental issues, energy growth, investment of private equity in energy generation units and difficulties of transmission lines expansion, distributed generation (DG) units have been used in power systems. Moreover, reduction in the need for transmission and distribution, the increase of reliability, improvement of power quality, and reduction of power loss have caused DG to be placed in power systems. On the other hand, considering low liquidity need, private investors tend to spend their money for DGs. In this project, the main goal is to offer an algorithm for planning and placing DGs in order to reduce the need for transmission and distribution network.
Abstract: The following article presents Technology Centre of
Ostrava (TCO) in the Czech Republic describing the structure and
main research areas realized by the project ENET - Energy Units for
Utilization of non Traditional Energy Sources. More details are
presented from the research program dealing with transformation,
accumulation and distribution of electric energy. Technology Centre
has its own energy mix consisting of alternative sources of fuel
sources that use of process gases from the storage part and also the
energy from distribution network. The article will be focus on the
properties and application possibilities SiC semiconductor devices for
power semiconductor converter for photovoltaic systems.
Abstract: Distributed Generation (DG) systems are considered an integral part in future distribution system planning. Appropriate size and location of distributed generation plays a significant role in minimizing power losses in distribution systems. Among the benefits of distributed generation is the reduction in active power losses, which can improve the system performance, reliability and power quality. In this paper, Artificial Bee Colony (ABC) algorithm is proposed to determine the optimal DG-unit size and location by loss sensitivity index in order to minimize the real power loss, total harmonic distortion (THD) and voltage sag index improvement. Simulation study is conducted on 69-bus radial test system to verify the efficacy of the proposed method.
Abstract: This paper, proposes a control system for use with microgrid consiste of multiple small scale embedded generation networks (SSEG networks) connected to the 33kV distribution network. The proposed controller controls power flow in the grid-connected mode of operation, enables voltage and frequency control when the SSEG networks are islanded, and resynchronises the SSEG networks with the utility before reconnecting them. The performance of the proposed controller has been tested in simulations using PSCAD.
Abstract: This paper presents a simple approach for load
flow analysis of a radial distribution network. The proposed
approach utilizes forward and backward sweep algorithm
based on Kirchoff-s current law (KCL) and Kirchoff-s voltage
law (KVL) for evaluating the node voltages iteratively. In this
approach, computation of branch current depends only on the
current injected at the neighbouring node and the current in
the adjacent branch. This approach starts from the end nodes
of sub lateral line, lateral line and main line and moves
towards the root node during branch current computation. The
node voltage evaluation begins from the root node and moves
towards the nodes located at the far end of the main, lateral
and sub lateral lines. The proposed approach has been tested
using four radial distribution systems of different size and
configuration and found to be computationally efficient.
Abstract: In this paper a combination approach of two heuristic-based algorithms: genetic algorithm and tabu search is proposed. It has been developed to obtain the least cost based on the split-pipe design of looped water distribution network. The proposed combination algorithm has been applied to solve the three well-known water distribution networks taken from the literature. The development of the combination of these two heuristic-based algorithms for optimization is aimed at enhancing their strengths and compensating their weaknesses. Tabu search is rather systematic and deterministic that uses adaptive memory in search process, while genetic algorithm is probabilistic and stochastic optimization technique in which the solution space is explored by generating candidate solutions. Split-pipe design may not be realistic in practice but in optimization purpose, optimal solutions are always achieved with split-pipe design. The solutions obtained in this study have proved that the least cost solutions obtained from the split-pipe design are always better than those obtained from the single pipe design. The results obtained from the combination approach show its ability and effectiveness to solve combinatorial optimization problems. The solutions obtained are very satisfactory and high quality in which the solutions of two networks are found to be the lowest-cost solutions yet presented in the literature. The concept of combination approach proposed in this study is expected to contribute some useful benefits in diverse problems.
Abstract: In this paper optimal capacitor placement problem has
been formulated in a restructured distribution network. In this
scenario the distribution network operator can consider reactive
energy also as a service that can be sold to transmission system. Thus
search for optimal location, size and number of capacitor banks with
the objective of loss reduction, maximum income from selling
reactive energy to transmission system and return on investment for
capacitors, has been performed. Results is influenced with economic
value of reactive energy, therefore problem has been solved for
various amounts of it. The implemented optimization technique is
genetic algorithm. For any value of reactive power economic value,
when reverse of investment index increase and change from zero or
negative values to positive values, the threshold value of selling
reactive power has been obtained. This increasing price of economic
parameter is reasonable until the network losses is less than loss
before compensation.
Abstract: This paper shows the results obtained in the analysis
of the impact of distributed generation (DG) on distribution losses
and presents a new algorithm to the optimal allocation of distributed
generation resources in distribution networks. The optimization is
based on a Hybrid Genetic Algorithm and Particle Swarm
Optimization (HGAPSO) aiming to optimal DG allocation in
distribution network. Through this algorithm a significant
improvement in the optimization goal is achieved. With a numerical
example the superiority of the proposed algorithm is demonstrated in
comparison with the simple genetic algorithm.
Abstract: Most of the losses in a power system relate to
the distribution sector which always has been considered.
From the important factors which contribute to increase losses
in the distribution system is the existence of radioactive flows.
The most common way to compensate the radioactive power
in the system is the power to use parallel capacitors. In
addition to reducing the losses, the advantages of capacitor
placement are the reduction of the losses in the release peak of
network capacity and improving the voltage profile. The point
which should be considered in capacitor placement is the
optimal placement and specification of the amount of the
capacitor in order to maximize the advantages of capacitor
placement.
In this paper, a new technique has been offered for the
placement and the specification of the amount of the constant
capacitors in the radius distribution network on the basis of
Genetic Algorithm (GA). The existing optimal methods for
capacitor placement are mostly including those which reduce
the losses and voltage profile simultaneously. But the
retaliation cost and load changes have not been considered as
influential UN the target function .In this article, a holistic
approach has been considered for the optimal response to this
problem which includes all the parameters in the distribution
network: The price of the phase voltage and load changes. So,
a vast inquiry is required for all the possible responses. So, in
this article, we use Genetic Algorithm (GA) as the most
powerful method for optimal inquiry.
Abstract: The security of power systems against malicious cyberphysical
data attacks becomes an important issue. The adversary
always attempts to manipulate the information structure of the power
system and inject malicious data to deviate state variables while
evading the existing detection techniques based on residual test. The
solutions proposed in the literature are capable of immunizing the
power system against false data injection but they might be too costly
and physically not practical in the expansive distribution network.
To this end, we define an algebraic condition for trustworthy power
system to evade malicious data injection. The proposed protection
scheme secures the power system by deterministically reconfiguring
the information structure and corresponding residual test. More
importantly, it does not require any physical effort in either microgrid
or network level. The identification scheme of finding meters being
attacked is proposed as well. Eventually, a well-known IEEE 30-bus
system is adopted to demonstrate the effectiveness of the proposed
schemes.
Abstract: In this paper a procedure for the split-pipe design of looped water distribution network based on the use of simulated annealing is proposed. Simulated annealing is a heuristic-based search algorithm, motivated by an analogy of physical annealing in solids. It is capable for solving the combinatorial optimization problem. In contrast to the split-pipe design that is derived from a continuous diameter design that has been implemented in conventional optimization techniques, the split-pipe design proposed in this paper is derived from a discrete diameter design where a set of pipe diameters is chosen directly from a specified set of commercial pipes. The optimality and feasibility of the solutions are found to be guaranteed by using the proposed method. The performance of the proposed procedure is demonstrated through solving the three well-known problems of water distribution network taken from the literature. Simulated annealing provides very promising solutions and the lowest-cost solutions are found for all of these test problems. The results obtained from these applications show that simulated annealing is able to handle a combinatorial optimization problem of the least cost design of water distribution network. The technique can be considered as an alternative tool for similar areas of research. Further applications and improvements of the technique are expected as well.
Abstract: Wind power is among the most actively developing distributed generation (DG) technology. Majority of the wind power based DG technologies employ wind turbine induction generators (WTIG) instead of synchronous generators, for the technical advantages like: reduced size, increased robustness, lower cost, and increased electromechanical damping. However, dynamic changes of wind speed make the amount of active/reactive power injected/drawn to a WTIG embedded distribution network highly variable. This paper analyzes the effect of wind speed changes on the active and reactive power penetration to the wind energy embedded distribution network. Four types of wind speed changes namely; constant, linear change, gust change and random change of wind speed are considered in the analysis. The study is carried out by three-phase, non-linear, dynamic simulation of distribution system component models. Results obtained from the investigation are presented and discussed.
Abstract: Solar Cells are destined to supply electric energy beginning from primary resources. It can charge a battery up to 12V dc. For residential use an inverter for 12V dc to 220Vac conversion is desired. For this a static DC-AC converter is necessarily inserted between the solar cells and the distribution network. This paper describes a new P.W.M. strategy for a voltage source inverter. This modulation strategy reduces the energy losses and harmonics in the P.W.M. voltage source inverter. This technique allows the P.W.M. voltage source inverter to become a new feasible solution for solar home application.
Abstract: Distributed Power generation has gained a lot of
attention in recent times due to constraints associated with
conventional power generation and new advancements in DG
technologies .The need to operate the power system economically
and with optimum levels of reliability has further led to an increase
in interest in Distributed Generation. However it is important to place
Distributed Generator on an optimum location so that the purpose of
loss minimization and voltage regulation is dully served on the
feeder. This paper investigates the impact of DG units installation on
electric losses, reliability and voltage profile of distribution networks.
In this paper, our aim would be to find optimal distributed
generation allocation for loss reduction subjected to constraint of
voltage regulation in distribution network. The system is further
analyzed for increased levels of Reliability. Distributed Generator
offers the additional advantage of increase in reliability levels as
suggested by the improvements in various reliability indices such as
SAIDI, CAIDI and AENS. Comparative studies are performed and
related results are addressed. An analytical technique is used in order
to find the optimal location of Distributed Generator. The suggested
technique is programmed under MATLAB software. The results
clearly indicate that DG can reduce the electrical line loss while
simultaneously improving the reliability of the system.