Abstract: This paper study the segmented split capacitor
Digital-to-Analog Converter (DAC) implemented in a differentialtype
12-bit Successive Approximation Analog-to-Digital Converter
(SA-ADC). The series capacitance split array method employed as it
reduced the total area of the capacitors required for high resolution
DACs. A 12-bit regular binary array structure requires 2049 unit
capacitors (Cs) while the split array needs 127 unit Cs. These results
in the reduction of the total capacitance and power consumption of
the series split array architectures as to regular binary-weighted
structures. The paper will show the 12-bit DAC series split capacitor
with 4-bit thermometer coded DAC architectures as well as the
simulation and measured results.
Abstract: A new nonlinear PID controller and its stability
analysis are presented in this paper. A nonlinear function is deduced
from the similarities between the control effort and the electric-field
effect of a capacitor. The conventional linear PID controller can be
modified into a nonlinear one by this function. To analyze the stability
of the nonlinear PID controlled system, an idea of energy equivalence
is adapted to avoid the conservativeness which is usually arisen from
some traditional theorems and Criterions. The energy equivalence is
naturally related with the conceptions of Passivity and T-Passivity. As
a result, an engineering guideline for the parameter design of the
nonlinear PID controller is obtained. An inverted pendulum system is
tested to verify the nonlinear PID control scheme.
Abstract: A wideband 2-1-1 cascaded ΣΔ modulator with a
single-bit quantizer in the two first stages and a 4-bit quantizer in the
final stage is developed. To reduce sensitivity of digital-to-analog
converter (DAC) nonlinearities in the feedback of the last stage,
dynamic element matching (DEM) is introduced. This paper presents
two modelling approaches: The first is MATLAB description and the
second is VHDL-AMS modelling of the proposed architecture and
exposes some high-level-simulation results allowing a behavioural
study. The detail of both ideal and non-ideal behaviour modelling are
presented. Then, the study of the effect of building blocks
nonidealities is presented; especially the influences of nonlinearity,
finite operational amplifier gain, amplifier slew rate limitation and
capacitor mismatch. A VHDL-AMS description presents a good
solution to predict system-s performances and can provide sensitivity
curves giving the impact of nonidealities on the system performance.
Abstract: At any point of time, a power system operating
condition should be stable, meeting various operational criteria and it
should also be secure in the event of any credible contingency. Present
day power systems are being operated closer to their stability limits
due to economic and environmental constraints. Maintaining a stable
and secure operation of a power system is therefore a very important
and challenging issue. Voltage instability has been given much
attention by power system researchers and planners in recent years,
and is being regarded as one of the major sources of power system
insecurity. Voltage instability phenomena are the ones in which the
receiving end voltage decreases well below its normal value and does
not come back even after setting restoring mechanisms such as VAR
compensators, or continues to oscillate for lack of damping against the
disturbances. Reactive power limit of power system is one of the major
causes of voltage instability. This paper investigates the effects of
coordinated series capacitors (SC) with static VAR compensators
(SVC) on steady-state voltage stability of a power system. Also, the
influence of the presence of series capacitor on static VAR
compensator controller parameters and ratings required to stabilize
load voltages at certain values are highlighted.
Abstract: This paper presents the impact study of GTO Controlled Series Capacitor (GCSC) parameters on measured impedance (Zseen) by MHO distance relays for single transmission line high voltage 220 kV in the presence of single phase to earth fault with fault resistance (RF). The study deals with a 220 kV single electrical transmission line of Eastern Algerian transmission networks at Group Sonelgaz (Algerian Company of Electrical and Gas) compensated by series Flexible AC Transmission System (FACTS) i.e. GCSC connected at midpoint of the transmission line. The transmitted active and reactive powers are controlled by three GCSC-s. The effects of maximum reactive power injected as well as injected maximum voltage by GCSC on distance relays measured impedance is treated. The simulations results investigate the effects of GCSC injected parameters: variable reactance (XGCSC), variable voltage (VGCSC) and reactive power injected (QGCSC) on measured resistance and reactance in the presence of earth fault with resistance fault varied between 5 to 50 Ω for three cases study.
Abstract: This paper presents two simplified models to
determine nodal voltages in power distribution networks. These
models allow estimating the impact of the installation of reactive
power compensations equipments like fixed or switched capacitor
banks. The procedure used to develop the models is similar to the
procedure used to develop linear power flow models of transmission
lines, which have been widely used in optimization problems of
operation planning and system expansion. The steady state non-linear
load flow equations are approximated by linear equations relating the
voltage amplitude and currents. The approximations of the linear
equations are based on the high relationship between line resistance
and line reactance (ratio R/X), which is valid for power distribution
networks. The performance and accuracy of the models are evaluated
through comparisons with the exact results obtained from the
solution of the load flow using two test networks: a hypothetical
network with 23 nodes and a real network with 217 nodes.
Abstract: With Power system movement toward restructuring along with factors such as life environment pollution, problems of transmission expansion and with advancement in construction technology of small generation units, it is expected that small units like wind turbines, fuel cells, photovoltaic, ... that most of the time connect to the distribution networks play a very essential role in electric power industry. With increase in developing usage of small generation units, management of distribution networks should be reviewed. The target of this paper is to present a new method for optimal management of active and reactive power in distribution networks with regard to costs pertaining to various types of dispersed generations, capacitors and cost of electric energy achieved from network. In other words, in this method it-s endeavored to select optimal sources of active and reactive power generation and controlling equipments such as dispersed generations, capacitors, under load tapchanger transformers and substations in a way that firstly costs in relation to them are minimized and secondly technical and physical constraints are regarded. Because the optimal management of distribution networks is an optimization problem with continuous and discrete variables, the new evolutionary method based on Ant Colony Algorithm has been applied. The simulation results of the method tested on two cases containing 23 and 34 buses exist and will be shown at later sections.
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: This work presents a new algorithm based on a combination of fuzzy (FUZ), Dynamic Programming (DP), and Genetic Algorithm (GA) approach for capacitor allocation in distribution feeders. The problem formulation considers two distinct objectives related to total cost of power loss and total cost of capacitors including the purchase and installation costs. The novel formulation is a multi-objective and non-differentiable optimization problem. The proposed method of this article uses fuzzy reasoning for sitting of capacitors in radial distribution feeders, DP for sizing and finally GA for finding the optimum shape of membership functions which are used in fuzzy reasoning stage. The proposed method has been implemented in a software package and its effectiveness has been verified through a 9-bus radial distribution feeder for the sake of conclusions supports. A comparison has been done among the proposed method of this paper and similar methods in other research works that shows the effectiveness of the proposed method of this paper for solving optimum capacitor planning problem.
Abstract: A universal current-mode biquad is described which
represents an economical variant of well-known KHN (Kerwin,
Huelsman, Newcomb) voltage-mode filter. The circuit consists of
two multiple-output OTAs and of two grounded capacitors. Utilizing
simple splitter of the input current and a pair of jumpers, all the basic
2nd-order transfer functions can be implemented. The principle is
verified by Spice simulation on the level of a CMOS structure of
OTAs.
Abstract: The realization of current-mode quadrature oscillators
using current controlled current conveyor transconductance
amplifiers (CCCCTAs) and grounded capacitors is presented. The
proposed oscillators can provide 2 sinusoidal output currents with 90º
phase difference. It is enabled non-interactive dual-current control for
both the condition of oscillation and the frequency of oscillation.
High output impedances of the configurations enable the circuit to be
cascaded without additional current buffers. The use of only
grounded capacitors is ideal for integration. The circuit performances
are depicted through PSpice simulations, they show good agreement
to theoretical anticipation.
Abstract: Static synchronous compensator (STATCOM) is a shunt connected voltage source converter (VSC), which can affect rapid control of reactive flow in the transmission line by controlling the generated a.c. voltage. The main aim of the paper is to design a power system installed with a Static synchronous compensator (STATCOM) and demonstrates the application of the linearised Phillips-heffron model in analyzing the damping effect of the STATCOM to improve power system oscillation stability. The proposed PI controller is designed to coordinate two control inputs: Voltage of the injection bus and capacitor voltage of the STATCOM, to improve the Dynamic stability of a SMIB system .The power oscillations damping (POD) control and power system stabilizer (PSS) and their coordinated action with proposed controllers are tested. The simulation result shows that the proposed damping controllers provide satisfactory performance in terms of improvements of dynamic stability of the system.
Abstract: Individually Network reconfiguration or Capacitor control
perform well in minimizing power loss and improving voltage
profile of the distribution system. But for heavy reactive power loads
network reconfiguration and for heavy active power loads capacitor
placement can not effectively reduce power loss and enhance
voltage profiles in the system. In this paper, an hybrid approach
that combine network reconfiguration and capacitor placement using
Harmony Search Algorithm (HSA) is proposed to minimize power
loss reduction and improve voltage profile. The proposed approach
is tested on standard IEEE 33 and 16 bus systems. Computational
results show that the proposed hybrid approach can minimize losses
more efficiently than Network reconfiguration or Capacitor control.
The results of proposed method are also compared with results
obtained by Simulated Annealing (SA). The proposed method has
outperformed in terms of the quality of solution compared to SA.
Abstract: This paper deals with the simulation of a Boost Power Factor Correction (PFC) Converter with Electro Magnetic Interference (EMI) Filter. The diode rectifier with output capacitor gives poor power factor. The Boost Converter of PFC Circuit is analyzed and then simulated with diode rectifier. The Boost PFC Converter with EMI Filter is simulated for resistive load. The power factor is improved using the proposed converter.
Abstract: An enhanced particle swarm optimization algorithm
(PSO) is presented in this work to solve the non-convex OPF
problem that has both discrete and continuous optimization variables.
The objective functions considered are the conventional quadratic
function and the augmented quadratic function. The latter model
presents non-differentiable and non-convex regions that challenge
most gradient-based optimization algorithms. The optimization
variables to be optimized are the generator real power outputs and
voltage magnitudes, discrete transformer tap settings, and discrete
reactive power injections due to capacitor banks. The set of equality
constraints taken into account are the power flow equations while the
inequality ones are the limits of the real and reactive power of the
generators, voltage magnitude at each bus, transformer tap settings,
and capacitor banks reactive power injections. The proposed
algorithm combines PSO with Newton-Raphson algorithm to
minimize the fuel cost function. The IEEE 30-bus system with six
generating units is used to test the proposed algorithm. Several cases
were investigated to test and validate the consistency of detecting
optimal or near optimal solution for each objective. Results are
compared to solutions obtained using sequential quadratic
programming and Genetic Algorithms.
Abstract: Happening of Ferroresonance phenomenon is one of the reasons of consuming and ruining transformers, so recognition of Ferroresonance phenomenon has a special importance. A novel method for classification of Ferroresonance presented in this paper. Using this method Ferroresonance can be discriminate from other transients such as capacitor switching, load switching, transformer switching. Wavelet transform is used for decomposition of signals and Competitive Neural Network used for classification. Ferroresonance data and other transients was obtained by simulation using EMTP program. Using Daubechies wavelet transform signals has been decomposed till six levels. The energy of six detailed signals that obtained by wavelet transform are used for training and trailing Competitive Neural Network. Results show that the proposed procedure is efficient in identifying Ferroresonance from other events.
Abstract: A fully on-chip low drop-out (LDO) voltage regulator with 100pF output load capacitor is presented. A novel frequency compensation scheme using current buffer is adopted to realize single dominant pole within the unit gain frequency of the regulation loop, the phase margin (PM) is at least 50 degree under the full range of the load current, and the power supply rejection (PSR) character is improved compared with conventional Miller compensation. Besides, the differentiator provides a high speed path during the load current transient. Implemented in 0.18μm CMOS technology, the LDO voltage regulator provides 100mA load current with a stable 1.8V output voltage consuming 80μA quiescent current.
Abstract: The continued interest in the use of distributed generation in recent years is leading to the growth in number of distributed generators connected to distribution networks. Steady state voltage rise resulting from the connection of these generators can be a major obstacle to their connection at lower voltage levels. The present electric distribution network is designed to keep the customer voltage within tolerance limit. This may require a reduction in connectable generation capacity, under utilization of appropriate generation sites. Thus distribution network operators need a proper voltage regulation method to allow the significant integration of distributed generation systems to existing network. In this work a voltage rise problem in a typical distribution system has been studied. A method for voltage regulation of distribution system with multiple DG system by coordinated operation distributed generator, capacitor and OLTC has been developed. A sensitivity based analysis has been carried out to determine the priority for individual generators in multiple DG environment. The effectiveness of the developed method has been evaluated under various cases through simulation results.
Abstract: This paper undertakes the problem of optimal
capacitor placement in a distribution system. The problem is how to
optimally determine the locations to install capacitors, the types and
sizes of capacitors to he installed and, during each load level,the
control settings of these capacitors in order that a desired objective
function is minimized while the load constraints,network constraints
and operational constraints (e.g. voltage profile) at different load
levels are satisfied. The problem is formulated as a combinatorial
optimization problem with a nondifferentiable objective function.
Four solution mythologies based on algorithms (GA),tabu search
(TS), and hybrid GA-SA algorithms are presented.The solution
methodologies are preceded by a sensitivity analysis to select the
candidate capacitor installation locations.
Abstract: This article presents new current-mode oscillator circuits using CDTAs which is designed from block diagram. The proposed circuits consist of two CDTAs and two grounded capacitors. The condition of oscillation and the frequency of oscillation can be adjusted by electronic method. The circuits have high output impedance and use only grounded capacitors without any external resistor which is very appropriate to future development into an integrated circuit. The results of PSPICE simulation program are corresponding to the theoretical analysis.