Investigating the Effect of Using Capacitors in the Pumping Station on the Harmonic Contents (Case Study: Kafr El - Shikh Governorate, Egypt)

Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.


Authors:



References:
[1] "Compensation Capacitors Effect on Harmonics Distribution in
Electrical Networks"; Hamoudi Moncef, European Journal of Scientific
Research, ISSN 1450-216X Vol.27 No.3 (2009), pp.392-399.
[2] "Investigation of switched capacitors effect on harmonic distortion
levels and performance analysis with active power filter"; Samet Biricik,
ISSN 0033-2097, R. 86 NR 11a/2010.
[3] "Effects of Capacitor Bank Defects on Harmonic Distortion and Park-s
Pattern Analysis in Induction Motors"; G. Das, World Academy of
Science, Engineering and Technology 62 2010,P(249-253).
[4] "Harmonics and how they relate to power factor"; W. Mack Grady,
power quality issues & opportunities conference (pqa-93), San Diego,
November 1993.
[5] "Harmonics and Transient Over voltages Due to Capacitor Switching",
Adly A. Girgis, IEEE transactions on industry applications, vol. 29, no.
6, November-December 1993.
[6] Robert F. Martin. "Harmonic Currents", Compliance Engineering,
http://www.ce-mag.com/99ARG/Martin103, retrieved 2010.
[7] "Power quality limited for power quality engineering",
http://www.pqeltd.com/index.htm.
[8] "Practical power factor correction",
http://www.allaboutcircuits.com/vol_2/chpt_11/5.
[9] "Reactive Power Factor Correction Capacitors", http://www.schneiderelectric.
us/sites/us/en.
[10] "Power factor From
[11] Wikipedia, the free encyclopedia",
http://en.wikipedia.org/wiki/Talk:Power_factor.