Abstract: The electric power supplied by a photovoltaic power
generation systems depends on the solar irradiation and temperature.
The PV system can supply the maximum power to the load at a
particular operating point which is generally called as maximum
power point (MPP), at which the entire PV system operates with
maximum efficiency and produces its maximum power. Hence, a
Maximum power point tracking (MPPT) methods are used to
maximize the PV array output power by tracking continuously the
maximum power point. The proposed MPPT controller is designed
for 10kW solar PV system installed at Cape Institute of Technology.
This paper presents the fuzzy logic based MPPT algorithm. However,
instead of one type of membership function, different structures of
fuzzy membership functions are used in the FLC design. The
proposed controller is combined with the system and the results are
obtained for each membership functions in Matlab/Simulink
environment. Simulation results are decided that which membership
function is more suitable for this system.
Abstract: In this paper an isolated wind-diesel hybrid power
system has been considered for reactive power control study having
an induction generator for wind power conversion and synchronous
alternator with automatic voltage regulator (AVR) for diesel unit is
presented. The dynamic voltage stability evaluation is dependent on
small signal analysis considering a Static VAR Compensator (SVC)
and IEEE type -I excitation system. It's shown that the variable
reactive power source like SVC is crucial to meet the varying
demand of reactive power by induction generator and load and to
acquire an excellent voltage regulation of the system with minimum
fluctuations. Integral square error (ISE) criterion can be used to
evaluate the optimum setting of gain parameters. Finally the dynamic
responses of the power systems considered with optimum gain setting
will also be presented.
Abstract: There are a variety of reference current identification
methods, for the shunt active power filter (SAPF), such as the
instantaneous active and reactive power, the instantaneous active and
reactive current and the synchronous detection method are evaluated
and compared under ideal, non sinusoidal and unbalanced voltage
conditions. The SAPF performances, for the investigated
identification methods, are tested for a non linear load. The
simulation results, using Matlab Power System Blockset Toolbox
from a complete structure, are presented and discussed.
Abstract: A modeling approach for CMOS gates is presented
based on the use of the equivalent inverter. A new model for the
inverter has been developed using a simplified transistor current
model which incorporates the nanoscale effects for the planar
technology. Parametric expressions for the output voltage are
provided as well as the values of the output and supply current to be
compatible with the CCS technology. The model is parametric
according the input signal slew, output load, transistor widths, supply
voltage, temperature and process. The transistor widths of the
equivalent inverter are determined by HSPICE simulations and
parametric expressions are developed for that using a fitting
procedure. Results for the NAND gate shows that the proposed
approach offers sufficient accuracy with an average error in
propagation delay about 5%.
Abstract: This paper reports the numerical and experimental
performances of Double Glass Wall are investigated. Two
configurations were considered namely, the Double Clear Glass Wall
(DCGW) and the Double Translucent Glass Wall (DTGW). The
coupled governing equations as well as boundary conditions are
solved using the finite element method (FEM) via COMSOLTM
Multiphysics. Temperature profiles and flow field of the DCGW and
DTGW are reported and discussed. Different constant heat fluxes
were considered as 400 and 800 W.m-2 the corresponding initial
condition temperatures were 30.5 and 38.5ºC respectively. The
results show that the simulation results are in agreement with the
experimental data. Conclusively, the model considered in this study
could reasonable be used simulate the thermal and ventilation
performance of the DCGW and DTGW configurations.
Abstract: In this research article a comprehensive investigation
has been carried out to determine the effect of thermal cycle on
temperature dependent process parameters developed during gas
tungsten arc (GTA) welding of high carbon (AISI 1090) steel butt
joints. An experiment based thermal analysis has been performed to
obtain the thermal history. We have focused on different
thermophysical properties such as thermal conductivity, heat transfer
coefficient and cooling rate. Angular torch model has been utilized to
find out the surface heat flux and its variation along the fusion zone as
well as along the longitudinal direction from fusion boundary. After
welding and formation of weld pool, heat transfer coefficient varies
rapidly in the vicinity of molten weld bead and heat affected zone. To
evaluate the heat transfer coefficient near the fusion line and near the
rear end of the plate (low temperature region), established correlation
has been implemented and has been compared with empirical
correlation which is noted as coupled convective and radiation heat
transfer coefficient. Change in thermal conductivity has been
visualized by analytical model of moving point heat source. Rate of
cooling has been estimated by using 2-dimensional mathematical
expression of cooling rate and it has shown good agreement with
experimental temperature cycle. Thermophysical properties have been
varied randomly within 0 -10s time span.
Abstract: The power converter that feeds high-frequency, highvoltage
transformers must be carefully designed due to parasitic
components, mainly the secondary winding capacitance and the
leakage inductance, that introduces resonances in relatively lowfrequency
range, next to the switching frequency. This paper
considers applications in which the load (resistive) has an
unpredictable behavior, changing from open to short-circuit condition
faster than the output voltage control loop could react. In this context,
to avoid overvoltage and over current situations, that could damage
the converter, the transformer or the load, it is necessary to find an
operation point that assure the desired output voltage in spite of the
load condition. This can done adjusting the frequency response of the
transformer adding an external inductance, together with selecting the
switching frequency to get stable output voltage independently of the
load.
Abstract: Distributed Generation (DG) can help in reducing the
cost of electricity to the costumer, relieve network congestion and
provide environmentally friendly energy close to load centers. Its
capacity is also scalable and it provides voltage support at distribution
level. Hence, DG placement and penetration level is an important
problem for both the utility and DG owner. DG allocation and capacity
determination is a nonlinear optimization problem. The objective
function of this problem is the minimization of the total loss of the
distribution system. Also high levels of penetration of DG are a new
challenge for traditional electric power systems. This paper presents a
new methodology for the optimal placement of DG and penetration
level of DG in distribution system based on General Algebraic
Modeling System (GAMS) and Genetic Algorithm (GA).
Abstract: This paper explains about the voltage output for DC to
DC boost converter between open loop, PID controller and fuzzy
logic controller through Matlab Simulink. Simulink input voltage was
set at 12V and the voltage reference was set at 24V. The analysis on
the deviation of voltage resulted that the difference between reference
voltage setting and the output voltage is always lower. Comparison
between open loop, PID and FLC shows that, the open loop circuit
having a bit higher on the deviation of voltage. The PID circuit
boosts for FLC has a lesser deviation of voltage and proved that it is
such a better performance on control the deviation of voltage during
the boost mode.
Abstract: This paper presents a study on Proportional Resonant
(PR) current control with additional PR harmonic compensators for
Grid Connected Photovoltaic (PV) Inverters. Both simulation and
experimental results will be presented. Testing was carried out on a
3kW Grid-Connected PV Inverter which was designed and
constructed for this research.
Abstract: A novel method to produce a fast high voltage solid
states switch using Insulated Gate Bipolar Transistors (IGBTs) is
presented for discharge-pumped gas lasers. The IGBTs are connected
in series to achieve a high voltage rating. An avalanche transistor is
used as the gate driver. The fast pulse generated by the avalanche
transistor quickly charges the large input capacitance of the IGBT,
resulting in a switch out of a fast high-voltage pulse. The switching
characteristic of fast-high voltage solid state switch has been estimated
in the multi-stage series-connected IGBT with the applied voltage of
several tens of kV. Electrical circuit diagram and the mythology of
fast-high voltage solid state switch as well as experimental results
obtained are presented.
Abstract: Hydrogenated amorphous carbon (a-C:H) films have
been synthesized by a radio frequency plasma enhanced chemical
vapor deposition (rf-PECVD) technique with different bias voltage
from 0.0 to -0.5 kV. The Raman spectra displayed the polymer-like
hydrogenated amorphous carbon (PLCH) film with 0.0 to -0.1 and
a-C:H films with -0.2 to -0.5 kV of bias voltages. The surface chemical
information of all films were studied by X-ray photoelectron
spectroscopy (XPS) technique, presented to C-C (sp2 and sp3) and C-O
bonds, and relative carbon (C) and oxygen (O) atomics contents. The
O contamination had affected on structure and optical properties. The
true density of PLCH and a-C:H films were characterized by X-ray
refractivity (XRR) method, showed the result as in the range of
1.16-1.73 g/cm3 that depending on an increasing of bias voltage. The
hardness was proportional to the true density of films. In addition, the
optical properties i.e. refractive index (n) and extinction coefficient (k)
of these films were determined by a spectroscopic ellipsometry (SE)
method that give formation to in 1.62-2.10 (n) and 0.04-0.15 (k)
respectively. These results indicated that the optical properties
confirmed the Raman results as presenting the structure changed with
applied bias voltage increased.
Abstract: Renewable energy is derived from natural processes
that are replenished constantly. Included in the definition is
electricity and heat generated from solar, wind, ocean, hydropower,
biomass, geothermal resources, and bio-fuels and hydrogen derived
from renewable resources. Each of these sources has unique
characteristics which influence how and where they are used. This
paper presents the modeling the simulation of solar and hydro hybrid
energy sources in MATLAB/SIMULINK environment. It simulates
all quantities of Hybrid Electrical Power system (HEPS) such as AC
output current of the inverter that injected to the load/grid, load
current, grid current. It also simulates power output from PV and
Hydraulic Turbine Generator (HTG), power delivered to or from grid
and finally power factor of the inverter for PV, HTG and grid. The
proposed circuit uses instantaneous p-q (real-imaginary) power
theory.
Abstract: In this paper a scheme is proposed for generating
a programmable current reference which can be implemented
in the CMOS technology. The current can be varied over a
wide range by changing an external voltage applied to one
of the control gates of FGMOS (Floating Gate MOSFET).
For a range of supply voltages and temperature, CMOS
current reference is found to be dependent, this dependence
is compensated by subtracting two current outputs with the
same dependencies on the supply voltage and temperature.
The system performance is found to improve with the
use of FGMOS. Mathematical analysis of the proposed
circuit is done to establish supply voltage and temperature
independence. Simulation and performance evaluation of the
proposed current reference circuit is done using TANNER
EDA Tools. The current reference shows the supply and
temperature dependencies of 520 ppm/V and 312 ppm/oC,
respectively. The proposed current reference can operate down
to 0.9 V supply.
Abstract: With advances in solid-state power electronic devices
and microprocessors, various pulse-width-modulation (PWM)
techniques have been developed for industrial applications. This
paper presents the comparison of two different PWM techniques, the
sinusoidal PWM (SPWM) technique and the space-vector PWM
(SVPWM) technique applied to two level VSI for micro grid
applications. These two methods are compared by discussing their
ease of implementation and by analyzing the output harmonic spectra
of various output voltages (line-to-neutral voltages, and line-to-line
voltages) and their total harmonic distortion (THD). The SVPWM
technique in the under-modulation region can increase the
fundamental output voltage by 15.5% over the SPWM technique.
Abstract: In this paper, numerical solution of system of
Fredholm and Volterra integral equations by means of the Spline
collocation method is considered. This approximation reduces the
system of integral equations to an explicit system of algebraic
equations. The solution is collocated by cubic B-spline and the
integrand is approximated by the Newton-Cotes formula. The error
analysis of proposed numerical method is studied theoretically. The
results are compared with the results obtained by other methods to
illustrate the accuracy and the implementation of our method.
Abstract: This paper presents a method for the efficient
implementation of a unidirectional or bidirectional DC/DC converter.
The DC/DC converter is used essentially for energy exchange
between the low voltage service battery and a high voltage battery
commonly found in Electric Vehicle applications. In these
applications, apart from cost, efficiency of design is an important
characteristic. A useful way to reduce the size of electronic
equipment in the electric vehicles is proposed in this paper. The
technique simplifies the mechanical complexity and maximizes the
energy usage using the latest converter control techniques. Moreover
a bidirectional battery charger for hybrid electric vehicles is also
implemented in this paper. Several simulations on the test system
have been carried out in Matlab/Simulink environment. The results
exemplify the robustness of the proposed design methodology in case
of a 1.5 KW DC-DC converter.
Abstract: In this paper, design of solid-state battery/supercapacitor emulator based on dc-dc boost converter is described.
The emulator mimics charging behavior of any storage device based
on a predefined behavior set by the user. The device is operated by a
two-level control structure: high-level emulating controller and low-
level input voltage controller. Simulation and experimental results are
shown to demonstrate the emulator operation.
Abstract: In this paper, we present a comparative assessment of
Space Vector Pulse Width Modulation (SVPWM) and Model
Predictive Control (MPC) for two-level three phase (2L-3P) Voltage
Source Inverter (VSI). VSI with associated system is subjected to
both control techniques and the results are compared.
Matlab/Simulink was used to model, simulate and validate the
control schemes. Findings of this study show that MPC is superior to
SVPWM in terms of total harmonic distortion (THD) and
implementation.
Abstract: This paper presents a model predictive control (MPC)
of a utility interactive (UI) single phase inverter (SPI) for a
photovoltaic (PV) system at residential/distribution level. The
proposed model uses single-phase phase locked loop (PLL) to
synchronize SPI with the grid and performs MPC control in a dq
reference frame. SPI model consists of boost converter (BC),
maximum power point tracking (MPPT) control, and a full bridge
(FB) voltage source inverter (VSI). No PI regulators to tune and
carrier and modulating waves are required to produce switching
sequence. Instead, the operational model of VSI is used to synthesize
sinusoidal current and track the reference. Model is validated using a
three kW PV system at the input of UI-SPI in Matlab/Simulink.
Implementation and results demonstrate simplicity and accuracy, as
well as reliability of the model.