Abstract: This paper presents a hybrid three phase rectifier for
high power factor application. This rectifier is composed by zero
voltage transition (ZVT) and zero current transition (ZCT) boost
converter with three phase diode bridge rectifier, in parallel with a six
pulse three phase pulse width modulation (PWM) controlled rectifier.
The proposed topology is capable of high power factor with DC
output voltage regulation by providing sinusoidal input. Also, it
increases the overall efficiency of the new hybrid rectifier to 94.56%
and the total harmonic distortion of the hybrid structure varies from
0% to 16% at nominal output power. This topology was simulated in
MATLAB/SIMULINK environment and the output waveforms
presented with experimental result.
Abstract: The mathematical analysis on radiation obtained and
the development of the solar photovoltaic (PV) array groundwater
pumping is needed in the rural areas of Thohoyandou for sizing and
power performance subject to the climate conditions within the area.
A simple methodology approach is developed for the directed
coupled solar, controller and submersible ground water pump system.
The system consists of a PV array, pump controller and submerged
pump, battery backup and charger controller. For this reason, the
theoretical solar radiation is obtained for optimal predictions and
system performance in order to achieve different design and
operating parameters. Here the examination of the PV schematic
module in a Direct Current (DC) application is used for obtainable
maximum solar power energy for water pumping. In this paper, a
simple efficient photovoltaic water pumping system is presented with
its theoretical studies and mathematical modeling of photovoltaics
(PV) system.
Abstract: The article presents the concept of an electromagnetic
circuit generator with permanent magnets mounted on the surface
rotor core designed for single phase work. Computation field-circuit
model was shown. The spectrum of time course of voltages in the
idle work was presented. The cross section with graphically
presentation of magnetic induction in particular parts of
electromagnetic circuits was presented. Distribution of magnetic
induction at the rated load point for each phase was shown. The time
course of voltages and currents for each phases for rated power were
displayed. An analysis of laboratory results and measurement of load
characteristics of the generator was discussed. The work deals with
three electromagnetic circuits of generators with permanent magnet
where output voltage characteristics versus rated power were
expressed.
Abstract: This study focuses on the cooling of a photovoltaic
panel (PV). Indeed, the cooling improves the conversion capacity of
this one and maintains, under extreme conditions of air temperature,
the panel temperature at an appreciable level which avoids the
altering. To do this, a fan provides forced circulation of air. Because
the fan is supplied by the panel, it is necessary to determine the
optimum operating point that unites efficiency of the PV with the
consumption of the fan. For this matter, numerical simulations are
performed at varying mass flow rates of air, under two extreme air
temperatures (50°C, 25°C) and a fixed solar radiation (1000W.m2) in
a case of no wind.
Abstract: Voltage sags are the most common power quality
disturbance in the distribution system. It occurs due to the fault in the
electrical network or by the starting of a large induction motor and
this can be solved by using the custom power devices such as
Dynamic Voltage Restorer (DVR). In this paper DVR is proposed to
compensate voltage sags on critical loads dynamically. The DVR
consists of VSC, injection transformers, passive filters and energy
storage (lead acid battery). By injecting an appropriate voltage, the
DVR restores a voltage waveform and ensures constant load voltage.
The simulation and experimental results of a DVR using MATLAB
software shows clearly the performance of the DVR in mitigating
voltage sags.
Abstract: In development of floating photovoltaic generation
system, finding a suitable place of installation is as important as
development of economically feasible and stable structure. Especially
since floating photovoltaic system has its facility floating on water
surface, it is extremely important to review the effects of weather
conditions such as wind, water flow and floating matters, various
factors (such as fogs) that can reduce generation efficiency, possibility
of connection with power system, and legal restrictions. The method of
investigating suitable area and resource for development of
tracking-type floating photovoltaic generation system was proposed in
this paper, which can be used for development of floating and ocean
photovoltaic system in the future.
Abstract: This paper aims at finding a suitable neural network
for monitoring congestion level in electrical power systems. In this
paper, the input data has been framed properly to meet the target
objective through supervised learning mechanism by defining normal
and abnormal operating conditions for the system under study. The
congestion level, expressed as line congestion index (LCI), is
evaluated for each operating condition and is presented to the NN
along with the bus voltages to represent the input and target data.
Once, the training goes successful, the NN learns how to deal with a
set of newly presented data through validation and testing
mechanism. The crux of the results presented in this paper rests on
performance comparison of a multi-layered feed forward neural
network with eleven types of back propagation techniques so as to
evolve the best training criteria. The proposed methodology has been
tested on the standard IEEE-14 bus test system with the support of
MATLAB based NN toolbox. The results presented in this paper
signify that the Levenberg-Marquardt backpropagation algorithm
gives best training performance of all the eleven cases considered in
this paper, thus validating the proposed methodology.
Abstract: Anultra-low power capacitor less low-dropout voltage
regulator with improved transient response using gain enhanced feed
forward path compensation is presented in this paper. It is based on a
cascade of a voltage amplifier and a transconductor stage in the feed
forward path with regular error amplifier to form a composite gainenhanced
feed forward stage. It broadens the gain bandwidth and thus
improves the transient response without substantial increase in power
consumption. The proposed LDO, designed for a maximum output
current of 100 mA in UMC 180 nm, requires a quiescent current of
69 )A. An undershot of 153.79mV for a load current changes from
0mA to 100mA and an overshoot of 196.24mV for current change of
100mA to 0mA. The settling time is approximately 1.1 )s for the
output voltage undershooting case. The load regulation is of 2.77
)V/mA at load current of 100mA. Reference voltage is generated by
using an accurate band gap reference circuit of 0.8V.The costly
features of SOC such as total chip area and power consumption is
drastically reduced by the use of only a total compensation
capacitance of 6pF while consuming power consumption of 0.096
mW.
Abstract: Two types of commercial cylindrical lithium ion
batteries (Panasonic 3.4 Ah NCR-18650B and Samsung 2.9 Ah
INR-18650), were investigated experimentally. The capacities of these
samples were individually measured using constant current-constant
voltage (CC-CV) method at different ambient temperatures (-10°C,
0°C, 25°C). Their internal resistance was determined by
electrochemical impedance spectroscopy (EIS) and pulse discharge
methods. The cells with different configurations of parallel connection
NCR-NCR, INR-INR and NCR-INR were charged/discharged at the
aforementioned ambient temperatures. The results showed that the
difference of internal resistance between cells much more evident at
low temperatures. Furthermore, the parallel connection of NCR-NCR
exhibits the most uniform temperature distribution in cells at -10°C,
this feature is quite favorable for the safety of the battery pack.
Abstract: Among all FACTS devices, the unified power flow
controller (UPFC) is considered to be the most versatile device.
This is due to its capability to control all the transmission system
parameters (impedance, voltage magnitude, and phase angle). With
the growing interest in UPFC, the attention to develop a mathematical
model has increased. Several models were introduced for UPFC in
literature for different type of studies in power systems. In this paper
a novel comparison study between two dynamic models of UPFC
with their proposed control strategies.
Abstract: Lightning protection systems (LPS) for wind power
generation is becoming an important public issue. A serious damage
of blades, accidents where low-voltage and control circuit
breakdowns are frequently occur in many wind farms. A grounding
system is one of the most important components required for
appropriate LPSs in wind turbines WTs. Proper design of a wind
turbine grounding system is demanding and several factors for the
proper and effective implementation must taken into account. In this
paper proposed procedure of proper design of grounding systems for
a wind turbine was introduced. This procedure depends on measuring
of ground current of simulated wind farm under lightning taking into
consideration the soil ionization. The procedure also includes the
Ground Potential Rise (GPR) and the voltage distributions at ground
surface level and Touch potential. In particular, the contribution of
mitigating techniques, such as rings, rods and the proposed design
were investigated.
Abstract: This paper presents the voltage problem location
classification using performance of Least Squares Support Vector
Machine (LS-SVM) and Learning Vector Quantization (LVQ) in
electrical power system for proper voltage problem location
implemented by IEEE 39 bus New- England. The data was collected
from the time domain simulation by using Power System Analysis
Toolbox (PSAT). Outputs from simulation data such as voltage, phase
angle, real power and reactive power were taken as input to estimate
voltage stability at particular buses based on Power Transfer Stability
Index (PTSI).The simulation data was carried out on the IEEE 39 bus
test system by considering load bus increased on the system. To verify
of the proposed LS-SVM its performance was compared to Learning
Vector Quantization (LVQ). The results showed that LS-SVM is faster
and better as compared to LVQ. The results also demonstrated that the
LS-SVM was estimated by 0% misclassification whereas LVQ had
7.69% misclassification.
Abstract: This paper presents the electrical effect of two neighboring distribution substation during the construction phase. The size of auxiliary grounding grid have an effect on entire grounding system. The bigger the size of auxiliary grounding grid, the lower the GPR and maximum touch voltage, with the exception that when the two grids are unconnected, i.e. the bigger the size of auxiliary grounding grid, the higher the maximum step voltage. The results in this paper could be served as design guideline of grounding system, and perhaps remedy of some troublesome grounding grids in power distribution’s system. Modeling and simulation is carried out on the Current Distribution Electromagnetic interference Grounding and Soil structure (CDEGS) program. The simulation results exhibit the design and analysis of power system grounding and perhaps could be set as a standard in grounding system design and modification in distribution substations.
Abstract: Partial shadowing is one of the problems that are always faced in terrestrial applications of solar photovoltaic (PV). The effects of partial shadow on the energy yield of conventional mono-crystalline and multi-crystalline PV modules have been researched for a long time. With deployment of new thin-film solar PV modules in the market, it is important to understand the performance of new PV modules operating under the partial shadow in the tropical zone. This paper addresses the impacts of different partial shadowing on the operating characteristics of four different types of solar PV modules that include multi-crystalline, amorphous thin-film, CdTe thin-film and CIGS thin-film PV modules.
Abstract: Most of the PV systems are designed with transformer for safety purpose with galvanic isolation. However, the transformer is big, heavy and expensive. Also, it reduces the overall frequency of the conversion stage. Generally PV inverter with transformer is having efficiency around 92%–94% only. To overcome these problems, transformerless PV system is introduced. It is smaller, lighter, cheaper and higher in efficiency. However, dangerous leakage current will flow between PV array and the grid due to the stray capacitance. There are different types of configurations available for transformerless inverters like H5, H6, HERIC, oH5, and Dual paralleled buck inverter. But each configuration is suffering from its own disadvantages like high conduction losses, shoot-through issues of switches, dead-time requirements at zero crossing instants of grid voltage to avoid grid shoot-through faults and MOSFET reverse recovery issues. The main objective of the proposed transformerless inverter is to address two key issues: One key issue for a transformerless inverter is that it is necessary to achieve high efficiency compared to other existing inverter topologies. Another key issue is that the inverter configuration should not have any shoot-through issues for higher reliability.
Abstract: Static VAR System (SVS) is a kind of FACTS device which is used in power system primarily for the purpose of voltage and reactive power control. In this paper presents a systematic approach for designing SVS supplementary controller, which is used to improve the damping of power system oscillation. The combined bus voltage and line current (CBVLC) supplementary controller has been developed and incorporated in the SVS control system located at the middle of the series compensated long transmission line. Damping of torsional stresses due to subsynchronous resonance resulting from series capacitive compensation using CBVLC is investigated in this paper. Simulation results are carried out with MATLAB/Simulink on the IEEE first benchmark model (FBM). The simulation results show that the oscillations are satisfactorily damped out by the SVS supplementary controller. Time domain simulation is performed on power system and the results demonstrate the effectiveness of the proposed controller.
Abstract: A new algorithm based on the lattice Boltzmann method (LBM) is proposed as a potential solver for one-dimensional heat and mass transfer for isothermal carbonization of wood particles. To check the validity of this algorithm, the LBM results have been compared with the published data and a good agreement is obtained. Then, the model is used to study the effect of reactor temperature and particle size on the evolution of the local temperature and mass loss inside the wood particle.
Abstract: The Indian subcontinent is facing a massive challenge with regards to energy security in its member countries; to provide reliable electricity to facilitate development across various sectors of the economy and consequently achieve the developmental targets. The instability of the current precarious situation is observable in the frequent system failures and blackouts.
The deployment of interconnected electricity ‘Supergrid’ designed to carry huge quanta of power across the Indian sub-continent is proposed in this paper. Not only enabling energy security in the subcontinent it will also provide a platform for Renewable Energy Sources (RES) integration. This paper assesses the need and conditions for a Supergrid deployment and consequently proposes a meshed topology based on Voltage Source High Voltage Direct Current (VSC- HVDC) converters for the Supergrid modeling. Various control schemes for the control of voltage and power are utilized for the regulation of the network parameters. A 3 terminal Multi Terminal Direct Current (MTDC) network is used for the simulations.
Abstract: The high efficiency power management IC (PMIC) with switching device is presented in this paper. PMIC is controlled with PFM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS (DT-CMOS) with low on-resistance is designed to decrease conduction loss. The threshold voltage of DT-CMOS drops as the gate voltage increase, resulting in a much higher current handling capability than standard MOSFET. PFM control circuits consist of a generator, AND gate and comparator. The generator is made to have 1.2MHz oscillation voltage. The DC-DC converter based on PFM control circuit and low on-resistance switching device is presented in this paper.
Abstract: For Common R or R-L load to apply arbitrary voltage,
the bridge traditional inverters don’t have any difficulties by PWM
method. However for driving some piezoelectric actuator, arbitrary
voltage not a pulse but a steady voltage should be applied.
Piezoelectric load is considered as R-C load and its voltage does not
decrease even though the applied voltage decreases. Therefore it needs
some special inverter with circuit that can discharge the capacitive
energy. Especially for unidirectional arbitrary voltage driving like as
sine wave, it becomes more difficult problem. In this paper, a charge
and discharge circuit for unidirectional arbitrary voltage driving for
piezoelectric actuator is proposed. The circuit has charging and
discharging switches for increasing and decreasing output voltage.
With the proposed simple circuit, the load voltage can have any
unidirectional level with tens of bandwidth because the load voltage
can be adjusted by switching the charging and discharging switch
appropriately. The appropriateness is proved from the simulation of
the proposed circuit.