Abstract: The distribution networks are often exposed to harmful
incidents which can halt the electricity supply of the customer. In this
context, we studied a real case of a critical zone of the Tunisian
network which is currently characterized by the dysfunction of its
plan of protection. In this paper, we were interested in the
harmonization of the protection plan settings in order to ensure a
perfect selectivity and a better continuity of service on the whole of
the network.
Abstract: In this paper, an analysis of some model order
reduction techniques is presented. A new hybrid algorithm for model
order reduction of linear time invariant systems is compared with the
conventional techniques namely Balanced Truncation, Hankel Norm
reduction and Dominant Pole Algorithm (DPA). The proposed hybrid
algorithm is known as Clustering Dominant Pole Algorithm (CDPA),
is able to compute the full set of dominant poles and its cluster center
efficiently. The dominant poles of a transfer function are specific
eigenvalues of the state space matrix of the corresponding dynamical
system. The effectiveness of this novel technique is shown through
the simulation results.
Abstract: This paper discusses the undesirable charge transfer
through the parasitic capacitances of the input transistors in a
multi-inputs voltage sense amplifier. Its intrinsic rail-to-rail voltage
transitions at the output nodes inevitably disturb the input sides
through the capacitive coupling between the outputs and inputs. Then,
it can possible degrade the stabilities of the reference voltage levels.
Moreover, it becomes more serious in multi-channel systems by
altering them for other channels, and so degrades the linearity of the
overall systems. In order to alleviate the internal node voltage
transition, the internal node stabilization techniques are proposed. It
achieves 45% and 40% improvements for node stabilization and input
referred disturbance, respectively.
Abstract: Based on the experimental data, the impact of
resistance and reactance of the winding, as well as the magnetic
permeability of the magnetic circuit steel material on the value of the
electromotive force of the induction converter is investigated. The
obtained results allow estimating the main technological spreads and
determining the maximum level of the electromotive force change.
By the method of experiment planning, the expression of a
polynomial for the electromotive force which can be used to estimate
the adequacy of mathematical models to be used at the investigation
and design of induction converters is obtained.
Abstract: ESPRIT-TLS method appears a good choice for high
resolution fault detection in induction machines. It has a very high
effectiveness in the frequency and amplitude identification.
Contrariwise, it presents a high computation complexity which
affects its implementation in real time fault diagnosis. To avoid this
problem, a Fast-ESPRIT algorithm that combined the IIR band-pass
filtering technique, the decimation technique and the original
ESPRIT-TLS method was employed to enhance extracting accurately
frequencies and their magnitudes from the wind stator current with
less computation cost. The proposed algorithm has been applied to
verify the wind turbine machine need in the implementation of an online,
fast, and proactive condition monitoring. This type of remote
and periodic maintenance provides an acceptable machine lifetime,
minimize its downtimes and maximize its productivity. The
developed technique has evaluated by computer simulations under
many fault scenarios. Study results prove the performance of Fast-
ESPRIT offering rapid and high resolution harmonics recognizing
with minimum computation time and less memory cost.
Abstract: Wind energy offers a significant advantage such as no
fuel costs and no emissions from generation. However, wind energy
sources are variable and non-dispatchable. The utility grid is able to
accommodate the variability of wind in smaller proportion along with
the daily load. However, at high penetration levels, the variability can
severely impact the utility reserve requirements and the cost
associated with it. In this paper the impact of wind energy is
evaluated in detail in formulating the total utility cost. The objective
is to minimize the overall cost of generation while ensuring the
proper management of the load. Overall cost includes the curtailment
cost, reserve cost and the reliability cost, as well as any other penalty
imposed by the regulatory authority. Different levels of wind
penetrations are explored and the cost impacts are evaluated. As the
penetration level increases significantly, the reliability becomes a
critical question to be answered. Here we increase the penetration
from the wind yet keep the reliability factor within the acceptable
limit provided by NERC. This paper uses an economic dispatch (ED)
model to incorporate wind generation into the power grid. Power
system costs are analyzed at various wind penetration levels using
Linear Programming. The goal of this study is show how the
increases in wind generation will affect power system economics.
Abstract: At present, the cascade PID control is widely used to
control the superheating temperature (main steam temperature). As
Main Steam Temperature has the characteristics of large inertia, large
time-delay and time varying, etc., conventional PID control strategy
cannot achieve good control performance. In order to overcome the
bad performance and deficiencies of main steam temperature control
system, Model Free Adaptive Control (MFAC) - P cascade control
system is proposed in this paper. By substituting MFAC in PID of the
main control loop of the main steam temperature control, it can
overcome time delays, non-linearity, disturbance and time variation.
Abstract: IEEE 802.11a/b/g standards provide multiple
transmission rates, which can be changed dynamically according to the
channel condition. Cooperative communications were introduced to
improve the overall performance of wireless LANs with the help of
relay nodes with higher transmission rates. The cooperative
communications are based on the fact that the transmission is much
faster when sending data packets to a destination node through a relay
node with higher transmission rate, rather than sending data directly to
the destination node at low transmission rate. To apply the cooperative
communications in wireless LAN, several MAC protocols have been
proposed. Some of them can result in collisions among relay nodes in a
dense network. In order to solve this problem, we propose a new
protocol. Relay nodes are grouped based on their transmission rates.
And then, relay nodes only in the highest group try to get channel
access. Performance evaluation is conducted using simulation, and
shows that the proposed protocol significantly outperforms the
previous protocol in terms of throughput and collision probability.
Abstract: The pursuit of the MPPT has led to the development of many kinds of controllers, one of which is the Fuzzy Logic controller, which has proven its worth. To further tune this controller this paper will discuss and analyze the use of Genetic Algorithms to tune the Fuzzy Logic Controller. It will provide an introduction to both systems, and test their compatibility and performance.
Abstract: In this paper, reliable consensus of multi-agent systems
with sampled-data is investigated. By using a suitable
Lyapunov-Krasovskii functional and some techniques such as
Wirtinger Inequality, Schur Complement and Kronecker Product, the
results of such system are obtained by solving a set of Linear Matrix
Inequalities (LMIs). One numerical example is included to show the
effectiveness of the proposed criteria.
Abstract: Power systems are operating under stressed condition
due to continuous increase in demand of load. This can lead to
voltage instability problem when face additional load increase or
contingency. In order to avoid voltage instability suitable size of
reactive power compensation at optimal location in the system is
required which improves the load margin. This work aims at
obtaining optimal size as well as location of compensation in the 39-
bus New England system with the help of Bacteria Foraging and
Genetic algorithms. To reduce the computational time the work
identifies weak candidate buses in the system, and then picks only
two of them to take part in the optimization. The objective function is
based on a recently proposed voltage stability index which takes into
account the weighted average sensitivity index is a simpler and faster
approach than the conventional CPF algorithm. BFOA has been
found to give better results compared to GA.
Abstract: This paper proposes five level diode clamped Z source
Inverter. The existing PWM techniques used for ZSI are restricted for
two level. The two level Z Source Inverter have high harmonic
distortions which effects the performance of the grid connected PV
system. To improve the performance of the system the number of
voltage levels in the output waveform need to be increased. This
paper presents comparative analysis of a five level diode clamped Z
source Inverter with different carrier based Modified Pulse Width
Modulation techniques. The parameters considered for comparison
are output voltage, voltage gain, voltage stress across switch and total
harmonic distortion when powered by same DC supply. Analytical
results are verified using MATLAB.
Abstract: In this paper, we discuss the performance of applying
hybrid spiral dynamic bacterial chemotaxis (HSDBC) optimisation
algorithm on an intelligent controller for a differential drive robot. A
unicycle class of differential drive robot is utilised to serve as a basis
application to evaluate the performance of the HSDBC algorithm. A
hybrid fuzzy logic controller is developed and implemented for the
unicycle robot to follow a predefined trajectory. Trajectories of
various frictional profiles and levels were simulated to evaluate the
performance of the robot at different operating conditions. Controller
gains and scaling factors were optimised using HSDBC and the
performance is evaluated in comparison to previously adopted
optimisation algorithms. The HSDBC has proven its feasibility in
achieving a faster convergence toward the optimal gains and resulted
in a superior performance.
Abstract: This paper attempts to define the validity domain of
LSDP (Loop Shaping Design Procedure) controller system, by
determining the suitable uncertainty region, so that linear system be
stable. Indeed the LSDP controller cannot provide stability for any
perturbed system. For this, we will use the gap metric tool that is
introduced into the control literature for studying robustness
properties of feedback systems with uncertainty. A 2nd order electric
linear system example is given to define the validity domain of LSDP
controller and effectiveness gap metric.
Abstract: The number of persons with implanted cardiac
pacemakers (PM) has increased in Western countries. The aim of this
paper is to investigate the possible situations where persons with a
PM may be exposed to extremely low frequency (ELF) electric (EF)
and magnetic fields (MF) that may disturb their PM. Based on our
earlier studies, it is possible to find such high public exposure to EFs
only in some places near 400 kV power lines, where an EF may
disturb a PM in unipolar mode. Such EFs cannot be found near 110
kV power lines. Disturbing MFs can be found near welding
machines. However, we do not have measurement data from welding.
Based on literature and earlier studies at Tampere University of
Technology, it is difficult to find public EF or MF exposure that is
high enough to interfere with PMs.
Abstract: This paper presents dynamic models of distributed
generators (DG) and investigates dynamic behavior of the DG units
in the micro grid system. The DG units include photovoltaic and fuel
cell sources. The voltage source inverter is adopted since the
electronic interface which can be equipped with its controller to keep
stability of the micro grid during small signal dynamics. This paper
also introduces power management strategies and implements the DG
load sharing concept to keep the micro grid operation in gridconnected
and islanding modes of operation. The results demonstrate
the operation and performance of the photovoltaic and fuel cell as
distributed generators in a micro grid. The entire control system in
the micro grid is developed by combining the benefits of the power
control and the voltage control strategies. Simulation results are all
reported, confirming the validity of the proposed control technique.
Abstract: This work proposes a data-driven multiscale based
quantitative measures to reveal the underlying complexity of
electroencephalogram (EEG), applying to a rodent model of
hypoxic-ischemic brain injury and recovery. Motivated by that real
EEG recording is nonlinear and non-stationary over different
frequencies or scales, there is a need of more suitable approach over
the conventional single scale based tools for analyzing the EEG data.
Here, we present a new framework of complexity measures
considering changing dynamics over multiple oscillatory scales. The
proposed multiscale complexity is obtained by calculating entropies of
the probability distributions of the intrinsic mode functions extracted
by the empirical mode decomposition (EMD) of EEG. To quantify
EEG recording of a rat model of hypoxic-ischemic brain injury
following cardiac arrest, the multiscale version of Tsallis entropy is
examined. To validate the proposed complexity measure, actual EEG
recordings from rats (n=9) experiencing 7 min cardiac arrest followed
by resuscitation were analyzed. Experimental results demonstrate that
the use of the multiscale Tsallis entropy leads to better discrimination
of the injury levels and improved correlations with the neurological
deficit evaluation after 72 hours after cardiac arrest, thus suggesting an
effective metric as a prognostic tool.
Abstract: We address a new integer frequency offset (IFO)
estimation scheme with an aid of a pilot for orthogonal frequency
division multiplexing systems. After correlating each continual pilot
with a predetermined scattered pilot, the correlation value is again
correlated to alleviate the influence of the timing offset. From
numerical results, it is demonstrated that the influence of the timing
offset on the IFO estimation is significantly decreased.
Abstract: Transmission system performance analysis is vital to
proper planning and operations of power systems in the presence of
deregulation. Key performance indicators (KPIs) are often used as
measure of degree of performance. This paper gives a novel method
to determine the transmission efficiency by evaluating the ratio of
real power losses incurred from a specified transfer direction.
Available Transmission Transfer Efficiency (ATTE) expresses the
percentage of real power received resulting from inter-area available
power transfer. The Tie line (Rated system path) performance is seen
to differ from system wide (Network response) performance and
ATTE values obtained are transfer direction specific. The required
sending end quantities with specified receiving end ATC and the
receiving end power circle diagram are obtained for the tie line
analysis. The amount of real power loss load relative to the available
transfer capability gives a measure of the transmission grid
efficiency.
Abstract: Proposed paper dealt with the modelling and analysis of induction motor based on the mathematical expression using the graphical programming environment of Laboratory Virtual Instrument Engineering Workbench (LabVIEW). Induction motor modelling with the mathematical expression enables the motor to be simulated with the various required parameters. Owing to the invention of variable speed drives study about the induction motor characteristics became complex. In this simulation motor internal parameter such as stator resistance and reactance, rotor resistance and reactance, phase voltage, frequency and losses will be given as input. By varying the speed of motor corresponding parameters can be obtained they are input power, output power, efficiency, torque induced, slip and current.