Abstract: This paper presents an innovative method to control the rotational speed of a satellite solar panel during its deployment phase. A brushed DC motor has been utilized in the passive spring driven deployment mechanism to reduce the deployment speed. In order to use the DC motor as a damper, its connector terminals have been connected with an external resistance in a closed circuit. It means that, in this approach, there is no external power supply in the circuit. The working principle of this method is based on the back electromotive force (or back EMF) of the DC motor when an external torque (here the torque produced by the torsional springs) is coupled to the DC motor’s shaft. In fact, the DC motor converts to an electric generator and the current flows into the circuit and then produces the back EMF. Based on Lenz’s law, the generated current produced a torque which acts opposite to the applied external torque, and as a result, the deployment speed of the solar panel decreases. The main advantage of this method is to set an intended damping coefficient to the system via changing the external resistance. To produce the sufficient current, a gearbox has been assembled to the DC motor which magnifies the number of turns experienced by the DC motor. The coupled electro-mechanical equations of the system have been derived and solved, then, the obtained results have been presented. A full-scale prototype of the deployment mechanism has been built and tested. The potential application of brushed DC motors as a rotational speed damper has been successfully demonstrated.
Abstract: The formula project of Kinki University has been involved in the student Formula SAE of Japan (JSAE) since the second year the competition was held. The vehicle developed in the project uses a ZX-6R engine, which has been manufactured by Kawasaki Heavy Industries for the JSAE competition for the eighth time. The limited performance of the concept vehicle was improved through the development of a power train. The supercharger loading, engine dry sump, and engine cooling management of the vehicle were also enhanced. The supercharger loading enabled the vehicle to achieve a maximum output of 59.6 kW (80.6 PS)/9000 rpm and a maximum torque of 70.6 Nm (7.2 kgf m)/8000 rpm. We successfully achieved 90% of the engine’s torque band (4000–10000 rpm) with 50% of the revolutions in regular engine use (2000–12000 rpm). Using a dry sump system, we periodically managed hydraulic pressure during engine operation. A system that controls engine stoppage when hydraulic pressure falls was also constructed. Using the dry sump system at 80 mm reduced the required engine load and the vehicle’s center of gravity. Even when engine motion was suspended by the electromotive force exerted by the water pump, the circulation of cooling water was still possible. These findings enabled us to create a cooling system in accordance with the requirements of the competition.
Abstract: This article presents a vibration diagnostic method
designed for Permanent Magnets (PM) electrical machines–traction
motors and generators. Those machines are commonly used in traction
drives of electrical vehicles and small wind or water systems. The
described method is very innovative and unique. Specific structural
properties of machines excited by permanent magnets are used in this
method - electromotive force (EMF) generated due to vibrations. There
was analyzed number of publications, which describe vibration
diagnostic methods, and tests of electrical machines and there was no
method found to determine the technical condition of such machine
basing on their own signals. This work presents field-circuit model,
results of static tests, results of calculations and simulations.
Abstract: Based on the experimental data, the impact of
resistance and reactance of the winding, as well as the magnetic
permeability of the magnetic circuit steel material on the value of the
electromotive force of the induction converter is investigated. The
obtained results allow estimating the main technological spreads and
determining the maximum level of the electromotive force change.
By the method of experiment planning, the expression of a
polynomial for the electromotive force which can be used to estimate
the adequacy of mathematical models to be used at the investigation
and design of induction converters is obtained.
Abstract: This article presents a new vibration diagnostic
method designed to (PM) machines with permanent magnets. Those
devices are commonly used in small wind and water systems or
vehicles drives. The author’s method is very innovative and unique.
Specific structural properties of PM machines are used in this method
- electromotive force (EMF) generated due to vibrations. There was
analysed number of publications which describe vibration diagnostic
methods and tests of electrical PM machines and there was no
method found to determine the technical condition of such machine
basing on their own signals. In this article will be discussed: the
method genesis, the similarity of machines with permanent magnet to
vibration sensor and simulation and laboratory tests results. The
method of determination the technical condition of electrical machine
with permanent magnets basing on its own signals is the subject of
patent application and it is the main thesis of author’s doctoral
dissertation.
Abstract: This paper presents the performance of electricity
generation and consumption from solar generator installed at
Rajabhat Suan Sunandha’s learning center in Samutsongkram.
The result from the experiment showed that solar cell began to
work and distribute the current into the system when the solar energy
intensity was 340 w/m2, starting from 8:00 am to 4:00 pm (duration
of 8 hours). The highest intensity read during the experiment was
1,051.64w/m2. The solar power was 38.74kWh/day. The
electromotive force from solar cell averagely was 93.6V. However,
when connecting solar cell with the battery charge controller system,
the voltage was dropped to 69.07V. After evaluating the power
distribution ability and electricity load of tested solar cell, the result
showed that it could generate power to 11 units of 36-watt
fluorescent lamp bulbs, which was altogether 396W. In the
meantime, the AC to DC power converter generated 3.55A to the
load, and gave 781VA.
Abstract: Transient eddy current problem is solved in the
present paper by the method of the Laplace transform for the case of
a double conductor line located parallel to a conducting half-space.
The Fourier sine and cosine integral transforms are used in order to
find the Laplace transform of the solution. The inverse Laplace
transform of the solution is found in closed form. The integrated
electromotive force per unit length of the double conductor line is
calculated in the form of an improper integral.
Abstract: This paper presents a several diagnostic methods designed to electrical machinesespecially for permanent magnets (PM) machines. Those machines are commonly used in small wind and water systems and vehicles drives.Thosemethodsare preferred by the author in periodic diagnostic of electrical machines. The special attentionshould be paid to diagnostic method of turn-to-turn insulation and vibrations. Both of those methodswere createdinInstitute of Electrical Drives and MachinesKomel. The vibration diagnostic method is the main thesis of author’s doctoral dissertation. This is method of determination the technical condition of PM electrical machine basing on its own signals is the subject of patent application No P.405669. Specific structural properties of machines excited by permanent magnets are used in this method - electromotive force (EMF) generated due to vibrations. There was analysed number of publications which describe vibration diagnostic methods and tests of electrical machines with permanent magnets and there was no method found to determine the technical condition of such machine basing on their own signals.