Abstract: CNFET has emerged as an alternative material to
silicon for high performance, high stability and low power SRAM
design in recent years. SRAM functions as cache memory in
computers and many portable devices. In this paper, a new SRAM
cell design based on CNFET technology is proposed. The proposed
SRAM cell design for CNFET is compared with SRAM cell designs
implemented with the conventional CMOS and FinFET in terms of
speed, power consumption, stability, and leakage current. The
HSPICE simulation and analysis show that the dynamic power
consumption of the proposed 8T CNFET SRAM cell’s is reduced
about 48% and the SNM is widened up to 56% compared to the
conventional CMOS SRAM structure at the expense of 2% leakage
power and 3% write delay increase.
Abstract: We installed solar panels and digital meteorological equipments whose electrical power is supplied using PV on July 13, 2011. Then, the relationship between the electric power generation and the irradiation, air temperature, and wind velocity was investigated on a roof at a university. The electrical power generation, irradiation, air temperature, and wind velocity were monitored over two years. By analyzing the measured meteorological data and electric power generation data using PTC, we calculated the size of the solar panel that is most suitable for this system. We also calculated the wasted power generation using PTC with the measured meteorological data obtained in this study. In conclusion, to reduce the "wasted power generation", a smaller-size solar panel is required for stable operation.
Abstract: This work presents a comparison study between the state-space and polynomial methods for the design of the robust governor for load frequency control of steam turbine power systems. The robust governor is synthesized using the two approaches and the comparison is extended to include time and frequency domains performance, controller order, and uncertainty representation, weighting filters, optimality and sub-optimality. The obtained results are represented through tables and curves with reasons of similarities and dissimilarities.
Abstract: In this paper, the comparison between k-Nearest Neighbor (kNN) algorithms for classifying the 3D EEG model in brain balancing is presented. The EEG signal recording was conducted on 51 healthy subjects. Development of 3D EEG models involves pre-processing of raw EEG signals and construction of spectrogram images. Then, maximum PSD values were extracted as features from the model. There are three indexes for balanced brain; index 3, index 4 and index 5. There are significant different of the EEG signals due to the brain balancing index (BBI). Alpha-α (8–13 Hz) and beta-β (13–30 Hz) were used as input signals for the classification model. The k-NN classification result is 88.46% accuracy. These results proved that k-NN can be used in order to predict the brain balancing application.
Abstract: This investigation develops a revisable method for estimating the estimate value of equivalent 10 Hz voltage flicker (DV10) of a DC Electric Arc Furnace (EAF). This study also discusses three 161kV DC EAFs by field measurement, with those results indicating that the estimated DV10 value is significantly smaller than the survey value. The key point is that the conventional means of estimating DV10 is inappropriate. There is a main cause as the assumed Qmax is too small.
Although DC EAF is regularly operated in a constant MVA mode, the reactive power variation in the Main Transformer (MT) is more significant than that in the Furnace Transformer (FT). A substantial difference exists between estimated maximum reactive power fluctuation (DQmax) and the survey value from actual DC EAF operations. However, this study proposes a revisable method that can obtain a more accurate DV10 estimate than the conventional method.
Abstract: Generally, distributed generation units refer to small-scale electric power generators that produce electricity at a site close to the customer or an electric distribution system (in parallel mode). From the customers’ point of view, a potentially lower cost, higher service reliability, high power quality, increased energy efficiency, and energy independence can be the key points of a proper DG unit. Moreover, the use of renewable types of distributed generations such as wind, photovoltaic, geothermal or hydroelectric power can also provide significant environmental benefits. Therefore, it is of crucial importance to study their impacts on the distribution networks. A marked increase in Distributed Generation (DG), associated with medium voltage distribution networks, may be expected. Nowadays, distribution networks are planned for unidirectional power flows that are peculiar to passive systems, and voltage control is carried out exclusively by varying the tap position of the HV/MV transformer. This paper will compare different DG control methods and possible network reconfiguration aimed at assessing their effect on voltage profiles.
Abstract: In this paper, fractional order feedback control of a ball
beam model is investigated. The ball beam model is a particular
example of the double Integrator system having strongly nonlinear
characteristics and unstable dynamics which make the control of
such system a challenging task. Most of the work in fractional order
control systems are in theoretical nature and controller design and its
implementation in practice is very small. In this work, a successful
attempt has been made to design a fractional order PIλDμcontroller
for a benchmark laboratory ball and beam model. Better performance
can be achieved using a fractional order PID controller and it is
demonstrated through simulations results with a comparison to the
classic PID controller.
Abstract: Accurate Short Term Load Forecasting (STLF) is essential for a variety of decision making processes. However, forecasting accuracy can drop due to the presence of uncertainty in the operation of energy systems or unexpected behavior of exogenous variables. Interval Type 2 Fuzzy Logic System (IT2 FLS), with additional degrees of freedom, gives an excellent tool for handling uncertainties and it improved the prediction accuracy. The training data used in this study covers the period from January 1, 2012 to February 1, 2012 for winter season and the period from July 1, 2012 to August 1, 2012 for summer season. The actual load forecasting period starts from January 22, till 28, 2012 for winter model and from July 22 till 28, 2012 for summer model. The real data for Iraqi power system which belongs to the Ministry of Electricity.
Abstract: In this paper, for detection of inclined eccentricity in an induction motor, time–frequency analysis of the stator startup current is carried out. For this purpose, the discrete wavelet transform is used. Data are obtained from simulations, using winding function approach. The results show the validity of the approach for detecting the fault and discriminating with respect to other faults.
Abstract: For Common R or R-L load to apply arbitrary voltage,
the bridge traditional inverters don’t have any difficulties by PWM
method. However for driving some piezoelectric actuator, arbitrary
voltage not a pulse but a steady voltage should be applied.
Piezoelectric load is considered as R-C load and its voltage does not
decrease even though the applied voltage decreases. Therefore it needs
some special inverter with circuit that can discharge the capacitive
energy. Especially for unidirectional arbitrary voltage driving like as
sine wave, it becomes more difficult problem. In this paper, a charge
and discharge circuit for unidirectional arbitrary voltage driving for
piezoelectric actuator is proposed. The circuit has charging and
discharging switches for increasing and decreasing output voltage.
With the proposed simple circuit, the load voltage can have any
unidirectional level with tens of bandwidth because the load voltage
can be adjusted by switching the charging and discharging switch
appropriately. The appropriateness is proved from the simulation of
the proposed circuit.
Abstract: The Indian subcontinent is facing a massive challenge with regards to energy security in its member countries; to provide reliable electricity to facilitate development across various sectors of the economy and consequently achieve the developmental targets. The instability of the current precarious situation is observable in the frequent system failures and blackouts.
The deployment of interconnected electricity ‘Supergrid’ designed to carry huge quanta of power across the Indian sub-continent is proposed in this paper. Not only enabling energy security in the subcontinent it will also provide a platform for Renewable Energy Sources (RES) integration. This paper assesses the need and conditions for a Supergrid deployment and consequently proposes a meshed topology based on Voltage Source High Voltage Direct Current (VSC- HVDC) converters for the Supergrid modeling. Various control schemes for the control of voltage and power are utilized for the regulation of the network parameters. A 3 terminal Multi Terminal Direct Current (MTDC) network is used for the simulations.
Abstract: Static VAR System (SVS) is a kind of FACTS device which is used in power system primarily for the purpose of voltage and reactive power control. In this paper presents a systematic approach for designing SVS supplementary controller, which is used to improve the damping of power system oscillation. The combined bus voltage and line current (CBVLC) supplementary controller has been developed and incorporated in the SVS control system located at the middle of the series compensated long transmission line. Damping of torsional stresses due to subsynchronous resonance resulting from series capacitive compensation using CBVLC is investigated in this paper. Simulation results are carried out with MATLAB/Simulink on the IEEE first benchmark model (FBM). The simulation results show that the oscillations are satisfactorily damped out by the SVS supplementary controller. Time domain simulation is performed on power system and the results demonstrate the effectiveness of the proposed controller.
Abstract: Current transformers (CTs) are used to transform large primary currents to a small secondary current. Since most standard equipment’s are not designed to handle large primary currents the CTs have an important part in any electrical system for the purpose of Metering and Protection both of which are integral in Power system. Now a days due to advancement in solid state technology, the operation times of the protective relays have come to a few cycles from few seconds. Thus, in such a scenario it becomes important to study the transient response of the current transformers as it will play a vital role in the operating of the protective devices.
This paper shows the steady state and transient behavior of current transformers and how it changes with change in connected burden. The transient and steady state response will be captured using the data acquisition software LabVIEW. Analysis is done on the real time data gathered using LabVIEW. Variation of current transformer characteristics with changes in burden will be discussed.
Abstract: Analytical expressions of the current and angular errors, as well as the frequency characteristics of an induction converter describing the relation with its structural parameters, the core and winding characteristics are obtained. Based on estimation of the dependences obtained, a mathematical problem of parametric optimization is formulated which can successfully be used for investigating and diagnosing an induction converter.
Abstract: Attractive and creative advertisement displays are
often in high demand as they are known to have profound impact on
the commercial market. In the fast advancement of technology,
advertising trend has taken a great leap in attracting more and more
demanding consumers. A low-cost and low-power consumption
flipping advertisement board has been developed in this paper. The
design of the electrical circuit and the controller of the advertisement
board are presented. A microcontroller, a Darlington Pair driver and a
unipolar stepper motor were used to operate the electrical flipping
advertisement board. The proposed system has been implemented
and the hardware has been tested to demonstrate the capability of
displaying multiple advertisements in a panel.
Abstract: This paper presents the design and analysis of Liquid
Crystal (LC) based tunable reflectarray antenna with different design
configurations within X-band frequency range. The effect of LC
volume used for unit cell element on frequency tunability and
reflection loss performance has been investigated. Moreover different
slot embedded patch element configurations have been proposed for
LC based tunable reflectarray antenna design with enhanced
performance. The detailed fabrication and measurement procedure
for different LC based unit cells has been presented. The waveguide
scattering parameter measured results demonstrated that by using the
circular slot embedded patch elements, the frequency tunability and
dynamic phase range can be increased from 180MHz to 200MHz and
120° to 124° respectively. Furthermore the circular slot embedded
patch element can be designed at 10GHz resonant frequency with a
patch volume of 2.71mm3 as compared to 3.47mm3 required for
rectangular patch without slot.
Abstract: In order to evaluate the performance of a unified power
flow controller (UPFC), mathematical models for steady state and
dynamic analysis are to be developed. The steady state model is
mainly concerned with the incorporation of the UPFC in load flow
studies. Several load flow models for UPFC have been introduced
in literature, and one of the most reliable models is the decoupled
UPFC model. In spite of UPFC decoupled load flow model simplicity,
it is more robust compared to other UPFC load flow models and it
contains unique capabilities. Some shortcoming such as additional
set of nonlinear equations are to be solved separately after the load
flow solution is obtained. The aim of this study is to investigate the
different control strategies that can be realized in the decoupled load
flow model (individual control and combined control), and the impact
of the location of the UPFC in the network on its control parameters.
Abstract: This paper presents the voltage problem location
classification using performance of Least Squares Support Vector
Machine (LS-SVM) and Learning Vector Quantization (LVQ) in
electrical power system for proper voltage problem location
implemented by IEEE 39 bus New- England. The data was collected
from the time domain simulation by using Power System Analysis
Toolbox (PSAT). Outputs from simulation data such as voltage, phase
angle, real power and reactive power were taken as input to estimate
voltage stability at particular buses based on Power Transfer Stability
Index (PTSI).The simulation data was carried out on the IEEE 39 bus
test system by considering load bus increased on the system. To verify
of the proposed LS-SVM its performance was compared to Learning
Vector Quantization (LVQ). The results showed that LS-SVM is faster
and better as compared to LVQ. The results also demonstrated that the
LS-SVM was estimated by 0% misclassification whereas LVQ had
7.69% misclassification.
Abstract: This paper presents the design and analysis of Liquid
Crystal (LC) based tunable reflectarray antenna with different design
configurations within X-band frequency range. The effect of LC
volume used for unit cell element on frequency tunability and
reflection loss performance has been investigated. Moreover different
slot embedded patch element configurations have been proposed for
LC based tunable reflectarray antenna design with enhanced
performance. The detailed fabrication and measurement procedure
for different LC based unit cells has been presented. The waveguide
scattering parameter measured results demonstrated that by using the
circular slot embedded patch elements, the frequency tunability and
dynamic phase range can be increased from 180MHz to 200MHz and
120° to 124° respectively. Furthermore the circular slot embedded
patch element can be designed at 10GHz resonant frequency with a
patch volume of 2.71mm3 as compared to 3.47mm3 required for
rectangular patch without slot.
Abstract: Lightning protection systems (LPS) for wind power
generation is becoming an important public issue. A serious damage
of blades, accidents where low-voltage and control circuit
breakdowns are frequently occur in many wind farms. A grounding
system is one of the most important components required for
appropriate LPSs in wind turbines WTs. Proper design of a wind
turbine grounding system is demanding and several factors for the
proper and effective implementation must taken into account. In this
paper proposed procedure of proper design of grounding systems for
a wind turbine was introduced. This procedure depends on measuring
of ground current of simulated wind farm under lightning taking into
consideration the soil ionization. The procedure also includes the
Ground Potential Rise (GPR) and the voltage distributions at ground
surface level and Touch potential. In particular, the contribution of
mitigating techniques, such as rings, rods and the proposed design
were investigated.