Abstract: This paper presents the performance state analysis of
Self-Excited Induction Generator (SEIG) using Artificial Bee Colony
(ABC) optimization technique. The total admittance of the induction
machine is minimized to calculate the frequency and magnetizing
reactance corresponding to any rotor speed, load impedance and
excitation capacitance. The performance of SEIG is calculated using
the optimized parameter found. The results obtained by ABC
algorithm are compared with results from numerical method. The
results obtained coincide with the numerical method results. This
technique proves to be efficient in solving nonlinear constrained
optimization problems and analyzing the performance of SEIG.
Abstract: Researches and concerns in power quality gained
significant momentum in the field of power electronics systems over
the last two decades globally. This sudden increase in the number of
concerns over power quality problems is a result of the huge increase
in the use of non-linear loads. In this paper, power quality evaluation
of some distribution networks at Misurata - Libya has been done
using a power quality and energy analyzer (Fluke 437 Series II). The
results of this evaluation are used to minimize the problems of power
quality. The analysis shows the main power quality problems that
exist and the level of awareness of power quality issues with the aim
of generating a start point which can be used as guidelines for
researchers and end users in the field of power systems.
Abstract: Among all FACTS devices, the unified power flow
controller (UPFC) is considered to be the most versatile device.
This is due to its capability to control all the transmission system
parameters (impedance, voltage magnitude, and phase angle). With
the growing interest in UPFC, the attention to develop a mathematical
model has increased. Several models were introduced for UPFC in
literature for different type of studies in power systems. In this paper
a novel comparison study between two dynamic models of UPFC
with their proposed control strategies.
Abstract: This paper aims at finding a suitable neural network
for monitoring congestion level in electrical power systems. In this
paper, the input data has been framed properly to meet the target
objective through supervised learning mechanism by defining normal
and abnormal operating conditions for the system under study. The
congestion level, expressed as line congestion index (LCI), is
evaluated for each operating condition and is presented to the NN
along with the bus voltages to represent the input and target data.
Once, the training goes successful, the NN learns how to deal with a
set of newly presented data through validation and testing
mechanism. The crux of the results presented in this paper rests on
performance comparison of a multi-layered feed forward neural
network with eleven types of back propagation techniques so as to
evolve the best training criteria. The proposed methodology has been
tested on the standard IEEE-14 bus test system with the support of
MATLAB based NN toolbox. The results presented in this paper
signify that the Levenberg-Marquardt backpropagation algorithm
gives best training performance of all the eleven cases considered in
this paper, thus validating the proposed methodology.
Abstract: In development of floating photovoltaic generation
system, finding a suitable place of installation is as important as
development of economically feasible and stable structure. Especially
since floating photovoltaic system has its facility floating on water
surface, it is extremely important to review the effects of weather
conditions such as wind, water flow and floating matters, various
factors (such as fogs) that can reduce generation efficiency, possibility
of connection with power system, and legal restrictions. The method of
investigating suitable area and resource for development of
tracking-type floating photovoltaic generation system was proposed in
this paper, which can be used for development of floating and ocean
photovoltaic system in the future.
Abstract: Voltage sags are the most common power quality
disturbance in the distribution system. It occurs due to the fault in the
electrical network or by the starting of a large induction motor and
this can be solved by using the custom power devices such as
Dynamic Voltage Restorer (DVR). In this paper DVR is proposed to
compensate voltage sags on critical loads dynamically. The DVR
consists of VSC, injection transformers, passive filters and energy
storage (lead acid battery). By injecting an appropriate voltage, the
DVR restores a voltage waveform and ensures constant load voltage.
The simulation and experimental results of a DVR using MATLAB
software shows clearly the performance of the DVR in mitigating
voltage sags.
Abstract: The use of permanent magnets (PM) is increasing in
permanent magnet synchronous machines (PMSM) to fulfill the
requirements of high efficiency machines in modern industry. PMSM
are widely used in industrial applications, wind power plants and the
automotive industry. Since PMSM are used in different
environmental conditions, the long-term effect of NdFeB-based
magnets at high temperatures and their corrosion behavior have to be
studied due to the irreversible loss of magnetic properties.
In this paper, the effect of magnetic properties due to corrosion
and increasing temperature in a climatic chamber has been presented.
The magnetic moment and magnetic field of the magnets were
studied experimentally.
Abstract: The Sigma-Delta A/D converters have been proposed
as a practical application for A/D conversion at high rates because of
its simplicity and robustness to imperfections in the circuit, also
because the traditional converters are more difficult to implement in
VLSI technology. These difficulties with conventional conversion
methods need precise analog components in their filters and
conversion circuits, and are more vulnerable to noise and
interference. This paper aims to analyze the architecture, function and
application of Analog-Digital converters (A/D) Sigma-Delta to
overcome these difficulties, showing some simulations using the
Simulink software and Multisim.
Abstract: The article presents the concept of an electromagnetic
circuit generator with permanent magnets mounted on the surface
rotor core designed for single phase work. Computation field-circuit
model was shown. The spectrum of time course of voltages in the
idle work was presented. The cross section with graphically
presentation of magnetic induction in particular parts of
electromagnetic circuits was presented. Distribution of magnetic
induction at the rated load point for each phase was shown. The time
course of voltages and currents for each phases for rated power were
displayed. An analysis of laboratory results and measurement of load
characteristics of the generator was discussed. The work deals with
three electromagnetic circuits of generators with permanent magnet
where output voltage characteristics versus rated power were
expressed.
Abstract: This paper presents a hybrid three phase rectifier for
high power factor application. This rectifier is composed by zero
voltage transition (ZVT) and zero current transition (ZCT) boost
converter with three phase diode bridge rectifier, in parallel with a six
pulse three phase pulse width modulation (PWM) controlled rectifier.
The proposed topology is capable of high power factor with DC
output voltage regulation by providing sinusoidal input. Also, it
increases the overall efficiency of the new hybrid rectifier to 94.56%
and the total harmonic distortion of the hybrid structure varies from
0% to 16% at nominal output power. This topology was simulated in
MATLAB/SIMULINK environment and the output waveforms
presented with experimental result.
Abstract: This article presents a new vibration diagnostic
method designed to (PM) machines with permanent magnets. Those
devices are commonly used in small wind and water systems or
vehicles drives. The author’s method is very innovative and unique.
Specific structural properties of PM machines are used in this method
- electromotive force (EMF) generated due to vibrations. There was
analysed number of publications which describe vibration diagnostic
methods and tests of electrical PM machines and there was no
method found to determine the technical condition of such machine
basing on their own signals. In this article will be discussed: the
method genesis, the similarity of machines with permanent magnet to
vibration sensor and simulation and laboratory tests results. The
method of determination the technical condition of electrical machine
with permanent magnets basing on its own signals is the subject of
patent application and it is the main thesis of author’s doctoral
dissertation.
Abstract: The detection of environmental gases, 12CO2, 13CO2,
and CH4, using near-infrared semiconductor lasers with a short
laser path length is studied by means of wavelength-modulation
spectroscopy. The developed system is compact and has high
sensitivity enough to detect the absorption peaks of isotopic 13CO2
of a 3-% CO2 gas at 2 μm with a path length of 2.4 m, where
its peak size is two orders of magnitude smaller than that of the
ordinary 12CO2 peaks. In addition, the detection of 12CO2 peaks of
a 385-ppm (0.0385-%) CO2 gas in the air is made at 2 μm with a
path length of 1.4 m. Furthermore, in pursuing the detection of an
ancient environmental CH4 gas confined to a bubble in ice at the
polar regions, measurements of the absorption spectrum for a trace
gas of CH4 in a small area are attempted. For a 100-% CH4 gas
trapped in a ∼ 1 mm3 glass container, the absorption peaks of CH4
are obtained at 1.65 μm with a path length of 3 mm, and also the
gas pressure is extrapolated from the measured data.
Abstract: Ancillary services are support services which are
essential for humanizing and enhancing the reliability and security of
the electric power system. Reactive power ancillary service is one of
the important ancillary services in a restructured electricity market
which determines the cost of supplying ancillary services and finding
of how this cost would change with respect to operating decisions.
This paper presents a new formation that can be used to minimize the
Independent System Operator (ISO)’s total payment for reactive
power ancillary service. The modified power flow tracing algorithm
estimates the availability of reserve reactive power for ancillary
service. In order to find optimum reactive power dispatch,
Biogeography based optimization method (BPO) is proposed. Market
Reactive Clearing Price (MRCP) is then estimated and it encourages
generator companies (GENCOs) to participate in an ancillary service.
Finally, optimal weighting factor and real time utilization factor of
reactive power give the minimum ISO’s total payment. The
effectiveness of proposed design is verified using IEEE 30 bus
system.
Abstract: This study proposes the transformation of nonlinear
Magnetic Levitation System into linear one, via state and feedback
transformations using explicit algorithm. This algorithm allows
computing explicitly the linearizing state coordinates and feedback
for any nonlinear control system, which is feedback linearizable,
without solving the Partial Differential Equations. The algorithm is
performed using a maximum of N-1 steps where N being the
dimension of the system.
Abstract: This paper presents a method for the efficient
implementation of a unidirectional or bidirectional DC/DC converter.
The DC/DC converter is used essentially for energy exchange
between the low voltage service battery and a high voltage battery
commonly found in Electric Vehicle applications. In these
applications, apart from cost, efficiency of design is an important
characteristic. A useful way to reduce the size of electronic
equipment in the electric vehicles is proposed in this paper. The
technique simplifies the mechanical complexity and maximizes the
energy usage using the latest converter control techniques. Moreover
a bidirectional battery charger for hybrid electric vehicles is also
implemented in this paper. Several simulations on the test system
have been carried out in Matlab/Simulink environment. The results
exemplify the robustness of the proposed design methodology in case
of a 1.5 KW DC-DC converter.
Abstract: The parameters of a two-layer soil can be determined by
processing resistivity data obtained from resistivity measurements
carried out on the soil of interest. The processing usually entails
applying the resistivity data as inputs to an optimisation function.
This paper proposes an algorithm which utilises the square error as an
optimisation function. Resistivity data from previous works were
applied to test the accuracy of the new algorithm developed and the
result obtained conforms significantly to results from previous works.
Abstract: In this paper two approaches to joint signal detection,
time of arrival (ToA) and angle of arrival (AoA) estimation in
multi-element antenna array are investigated. Two scenarios were
considered: first one, when the waveform of the useful signal
is known a priori and, second one, when the waveform of the
desired signal is unknown. For first scenario, the antenna array
signal processing based on multi-element matched filtering (MF)
with the following non-coherent detection scheme and maximum
likelihood (ML) parameter estimation blocks is exploited. For second
scenario, the signal processing based on the antenna array elements
covariance matrix estimation with the following eigenvector analysis
and ML parameter estimation blocks is applied. The performance
characteristics of both signal processing schemes are thoroughly
investigated and compared for different useful signals and noise
parameters.
Abstract: The phased-array ultrasound transducer types are
utilities for medical ultrasonography as well as optical imaging.
However, their discontinuity characteristic limits the applications due
to the artifacts contaminated into the reconstructed images. Because
of the effects of the ultrasound pressure field pattern to the echo
ultrasonic waves as well as the optical modulated signal, the side
lobes of the focused ultrasound beam induced by discontinuity of the
phased-array ultrasound transducer might the reason of the artifacts.
In this paper, a simple method in approach of numerical simulation
was used to investigate the limitation of discontinuity of the elements
in phased-array ultrasound transducer and their effects to the
ultrasound pressure field. Take into account the change of ultrasound
pressure field patterns in the conditions of variation of the pitches
between elements of the phased-array ultrasound transducer, the
appropriated parameters for phased-array ultrasound transducer
design were asserted quantitatively.
Abstract: Different services based on different switching
techniques in wireless networks leads to drastic changes in the
properties of network traffic. Because of these diversities in services,
network traffic is expected to undergo qualitative and quantitative
variations. Hence, assumption of traffic characteristics and the
prediction of network events become more complex for the wireless
networks. In this paper, the traffic characteristics have been studied
by collecting traces from the mobile switching centre (MSC). The
traces include initiation and termination time, originating node, home
station id, foreign station id. Traffic parameters namely, call interarrival
and holding times were estimated statistically. The results
show that call inter-arrival and distribution time in this wireless
network is heavy-tailed and follow gamma distributions. They are
asymptotically long-range dependent. It is also found that the call
holding times are best fitted with lognormal distribution. Based on
these observations, an analytical model for performance estimation is
also proposed.
Abstract: In new energy development, wind power has boomed.
It is due to the proliferation of wind parks and their operation in
supplying the national electric grid with low cost and clean resources.
Hence, there is an increased need to establish a proactive
maintenance for wind turbine machines based on remote control and
monitoring. That is necessary with a real-time wireless connection in
offshore or inaccessible locations while the wired method has many
flaws. The objective of this strategy is to prolong wind turbine
lifetime and to increase productivity. The hardware of a remote
control and monitoring system for wind turbine parks is designed. It
takes advantage of GPRS or Wi-Max wireless module to collect data
measurements from different wind machine sensors through IP based
multi-hop communication. Computer simulations with Proteus ISIS
and OPNET software tools have been conducted to evaluate the
performance of the studied system. Study findings show that the
designed device is suitable for application in a wind park.