Abstract: In this paper, we proposed a novel SCR (Silicon Controlled
Rectifier) - based ESD (Electrostatic Discharge) protection device for I/O
and power clamp. The proposed device has a higher holding voltage
characteristic than conventional SCR. These characteristics enable to have
latch-up immunity under normal operating conditions as well as superior full
chip ESD protection. The proposed device was analyzed to figure out
electrical characteristics and tolerance robustness in term of individual
design parameters (D1, D2, D3). They are investigated by using the
Synopsys TCAD simulator. As a result of simulation, holding voltage
increased with different design parameters. The holding voltage of the
proposed device changes from 3.3V to 7.9V. Also, N-Stack structure ESD
device with the high holding voltage is proposed. In the simulation results,
2-stack has holding voltage of 6.8V and 3-stack has holding voltage of
10.5V. The simulation results show that holding voltage of stacking
structure can be larger than the operation voltage of high-voltage
application.
Abstract: Implementation of advanced technologies requires
sophisticated instruments that deal with the operation, control,
restoration and protection of rapidly growing power system network
under normal and abnormal conditions. Presently, the applications of
Phasor Measurement Unit (PMU) are widely found in real time
operation, monitoring, controlling and analysis of power system
network as it eliminates the various limitations of supervisory control
and data acquisition system (SCADA) conventionally used in power
system. The use of PMU data is very rapidly increasing its
importance for online and offline analysis. Wide area measurement
system (WAMS) is developed as new technology by use of multiple
PMUs in power system. The present paper proposes a model of
Matlab based PMU using Discrete Fourier Transform (DFT)
algorithm and evaluation of its operation under different
contingencies. In this paper, PMU based two bus system having
WAMS network is presented as a case study.
Abstract: The use of hydroelectric pump-storage system at large
scale, MW-size systems, is already widespread around the world.
Designed for large scale applications, pump-storage station can be
scaled-down for small, remote residential applications. Given the cost
and complexity associated with installing a substation further than
100 miles from the main transmission lines, a remote, independent
and self-sufficient system is by far the most feasible solution. This
article is aiming at the design of wind and solar power generating
system, by means of pumped-storage to replace the wind and /or solar
power systems with a battery bank energy storage. Wind and solar
pumped-storage power generating system can reduce the cost of
power generation system, according to the user's electricity load and
resource condition and also can ensure system reliability of power
supply. Wind and solar pumped-storage power generation system is
well suited for remote residential applications with intermittent wind
and/or solar energy. This type of power systems, installed in these
locations, could be a very good alternative, with economic benefits
and positive social effects. The advantage of pumped storage power
system, where wind power regulation is calculated, shows that a
significant smoothing of the produced power is obtained, resulting in
a power-on-demand system’s capability, concomitant to extra
economic benefits.
Abstract: This paper presents an application of Artificial Neural
Network (ANN) algorithm for improving power system voltage
stability. The training data is obtained by solving several normal and
abnormal conditions using the Linear Programming technique. The
selected objective function gives minimum deviation of the reactive
power control variables, which leads to the maximization of
minimum Eigen value of load flow Jacobian. The considered reactive
power control variables are switchable VAR compensators, OLTC
transformers and excitation of generators. The method has been
implemented on a modified IEEE 30-bus test system. The results
obtain from the test clearly show that the trained neural network is
capable of improving the voltage stability in power system with a
high level of precision and speed.
Abstract: While choosing insulating oil, characteristic features
such as thermal cooling, endurance, efficiency and being
environment-friendly should be considered. Mineral oils are referred
as petroleum-based oil. In this study, vegetable oils investigated as an
alternative insulating liquid to mineral oil. Dissipation factor,
breakdown voltage, relative dielectric constant and resistivity
changes with the frequency and voltage of mineral, rapeseed and nut
oils were measured. Experimental studies were performed according
to ASTM D924 and IEC 60156 standards.
Abstract: This paper is focused on the reference current
calculation in the compensation mode of the active DC traction
substations. The so-called p-q theory of the instantaneous reactive
power is used as theoretical foundation. The compensation goal of
total compensation is taken into consideration for the operation under
both sinusoidal and nonsinusoidal voltage conditions, through the
two objectives of unity power factor and perfect harmonic
cancelation. Four blocks of reference current generation implement
the conceived algorithms and they are included in a specific Simulink
library, which is useful in a DSP dSPACE-based platform working
under Matlab/Simulink. The simulation results validate the
correctness of the implementation and fulfillment of the
compensation tasks.
Abstract: High Voltage Direct Current (HVDC) power
transmission is employed to move large amounts of electric power.
There are several possibilities to enhance the transient stability in a
power system. One adequate option is by using the high
controllability of the HVDC if HVDC is available in the system. This
paper presents a control technique for HVDC to enhance the transient
stability. The strategy controls the power through the HVDC to help
make the system more transient stable during disturbances. Loss of
synchronism is prevented by quickly producing sufficient
decelerating energy to counteract accelerating energy gained during.
In this study, the power flow in the HVDC link is modulated with the
addition of an auxiliary signal to the current reference of the rectifier
firing angle controller. This modulation control signal is derived from
speed deviation signal of the generator utilizing a PD controller; the
utilization of a PD controller is suitable because it has the property of
fast response. The effectiveness of the proposed controller is
demonstrated with a SMIB test system.
Abstract: In this paper, influence of harmonics on medium
voltage distribution system of Bogazici Electricity Distribution Inc.
(BEDAS) which takes place at Istanbul/Turkey is investigated. A ring
network consisting of residential loads is taken into account for this
study. Real system parameters and measurement results are used for
simulations. Also, probable working conditions of the system are
analyzed for 50%, 75%, and 100% loading of transformers with
similar harmonic contents. Results of the study are exhibited the
influence of nonlinear loads on %THDV, P.F. and technical losses of
the medium voltage distribution system.
Abstract: Transparent nickel doped cobalt sulfide was fabricated
on a SnO2:F electrode and tested as an efficient electrocatalyst and as
an alternative to the expensive platinum counter electrode. In order to
investigate how this electrode could affect the electrical
characteristics of a dye-sensitized solar cell, we manufactured cells
with the same TiO2 photoanode sensitized with dye (N719) and
employing the same quasi-solid electrolyte, altering only the counter
electrode used. The cells were electrically and electrochemically
characterized and it was observed that the ones with the Ni doped
CoS2 outperformed the efficiency of the cells with the Pt counter
electrode (3.76% and 3.44% respectively). Particularly, the higher
efficiency of the cells with the Ni doped CoS2 counter electrode (CE)
is mainly because of the enhanced photocurrent density which is
attributed to the enhanced electrocatalytic ability of the CE and the
low charge transfer resistance at the CE/electrolyte interface.
Abstract: This article presents a vibration diagnostic method
designed for Permanent Magnets (PM) electrical machines–traction
motors and generators. Those machines are commonly used in traction
drives of electrical vehicles and small wind or water systems. The
described method is very innovative and unique. Specific structural
properties of machines excited by permanent magnets are used in this
method - electromotive force (EMF) generated due to vibrations. There
was analyzed number of publications, which describe vibration
diagnostic methods, and tests of electrical machines and there was no
method found to determine the technical condition of such machine
basing on their own signals. This work presents field-circuit model,
results of static tests, results of calculations and simulations.
Abstract: This paper presents a power control for a Doubly Fed
Induction Generator (DFIG) using in Wind Energy Conversion
System (WECS) connected to the grid. The proposed control strategy
employs two nonlinear controllers, Backstipping (BSC) and slidingmode
controller (SMC) scheme to directly calculate the required
rotor control voltage so as to eliminate the instantaneous errors of
active and reactive powers. In this paper the advantages of BSC and
SMC are presented, the performance and robustness of this two
controller’s strategy are compared between them. First, we present a
model of wind turbine and DFIG machine, then a synthesis of the
controllers and their application in the DFIG power control.
Simulation results on a 1.5MW grid-connected DFIG system are
provided by MATLAB/Simulink.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: As smartphones are equipped with various sensors,
there have been many studies focused on using these sensors to create
valuable applications. Human activity recognition is one such
application motivated by various welfare applications, such as the
support for the elderly, measurement of calorie consumption, lifestyle
and exercise patterns analyses, and so on. One of the challenges one
faces when using smartphone sensors for activity recognition is that
the number of sensors should be minimized to save battery power. In
this paper, we show that a fairly accurate classifier can be built that
can distinguish ten different activities by using only a single sensor
data, i.e., the smartphone accelerometer data. The approach that we
adopt to deal with this twelve-class problem uses various methods.
The features used for classifying these activities include not only the
magnitude of acceleration vector at each time point, but also the
maximum, the minimum, and the standard deviation of vector
magnitude within a time window. The experiments compared the
performance of four kinds of basic multi-class classifiers and the
performance of four kinds of ensemble learning methods based on
three kinds of basic multi-class classifiers. The results show that
while the method with the highest accuracy is ECOC based on
Random forest.
Abstract: In this study, electric field distribution analyses for
three pylon models are carried out by a Finite Element Method
(FEM) based software. Analyses are performed in both stationary and
time domains to observe instantaneous values along with the
effective ones. Considering the results of the study, different line
geometries is considerably affecting the magnitude and distribution
of electric field although the line voltages are the same. Furthermore,
it is observed that maximum values of instantaneous electric field
obtained in time domain analysis are quite higher than the effective
ones in stationary mode. In consequence, electric field distribution
analyses should be individually made for each different line model
and the limit exposure values or distances to residential buildings
should be defined according to the results obtained.
Abstract: Photovoltaic (PV) power generation systems, mainly
small scale, are rapidly being deployed in Jordan. The impact of these
systems on the grid has not been studied or analyzed. These systems
can cause many technical problems such as reverse power flows and
voltage rises in distribution feeders, and real and reactive power
transients that affect the operation of the transmission system. To
fully understand and address these problems, extensive research,
simulation, and case studies are required. To this end, this paper
studies the cloud shadow effect on the power generation of a ground
mounted PV system installed at the test field of the Renewable
Energy Center at the Applied Science University.
Abstract: Multiple-input multiple-output (MIMO) radar has
received increasing attention in recent years. MIMO radar has many
advantages over conventional phased array radar such as target
detection,resolution enhancement, and interference suppression. In
this paper, the results are presented from a simulation study of MIMO
uniformly-spaced linear array (ULA) antennas. The performance is
investigated under varied parameters, including varied array size,
pseudo random (PN) sequence length, number of snapshots, and
signal to noise ratio (SNR). The results of MIMO are compared to a
traditional array antenna.
Abstract: As per the statistical data, the Doubly-fed Induction
Generator (DFIG) based wind turbine with variable speed and
variable pitch control is the most common wind turbine in the
growing wind market. This machine is usually used on the grid
connected wind energy conversion system to satisfy grid code
requirements such as grid stability, Fault Ride Through (FRT), power
quality improvement, grid synchronization and power control etc.
Though the requirements are not fulfilled directly by the machine, the
control strategy is used in both the stator as well as rotor side along
with power electronic converters to fulfil the requirements stated
above. To satisfy the grid code requirements of wind turbine, usually
grid side converter is playing a major role. So in order to improve the
operation capacity of wind turbine under critical situation, the
intensive study of both machine side converter control and grid side
converter control is necessary In this paper DFIG is modeled using
power components as variables and the performance of the DFIG
system is analysed under grid voltage fluctuations. The voltage
fluctuations are made by lowering and raising the voltage values in
the utility grid intentionally for the purpose of simulation keeping in
view of different grid disturbances.
Abstract: Although there has been a growing interest in the
hybrid free-space optical link and radio frequency FSO/RF
communication system, the current literature is limited to results
obtained in moderate or cold environment. In this paper, using a soft
switching approach, we investigate the effect of weather
inhomogeneities on the strength of turbulence hence the channel
refractive index under Qatar harsh environment and their influence
on the hybrid FSO/RF availability. In this approach, either FSO/RF
or simultaneous or none of them can be active. Based on soft
switching approach and a finite state Markov Chain (FSMC) process,
we model the channel fading for the two links and derive a
mathematical expression for the outage probability of the hybrid
system. Then, we evaluate the behavior of the hybrid FSO/RF under
hazy and harsh weather. Results show that the FSO/RF soft switching
renders the system outage probability less than that of each link
individually. A soft switching algorithm is being implemented on
FPGAs using Raptor code interfaced to the two terminals of a
1Gbps/100 Mbps FSO/RF hybrid system, the first being implemented
in the region. Experimental results are compared to the above
simulation results.
Abstract: Space Vector Pulse Width Modulation is popular for
variable frequency drives. The method has several advantages over
carried based PWM and is computation intensive. The
implementation of SVPWM for multilevel inverter requires special
attention and at the same time consumes considerable resources. Due
to faster processing power and reduced over all computational
burden, FPGAs are being investigated as an alternative for other
controllers. In this paper, a space vector PWM algorithm is
implemented using FPGA which requires less computational area and
is modular in structure. The algorithm is verified experimentally for
Neutral Point Clamped inverter using FPGA development board
xc3s5000-4fg900.
Abstract: This paper discusses the general methods to saturation
in the steady-state, two axis (d & q) frame models of synchronous
machines. In particular, the important role of the magnetic coupling
between the d-q axes (cross-magnetizing phenomenon), is
demonstrated. For that purpose, distinct methods of saturation
modeling of dumper synchronous machine with cross-saturation are
identified, and detailed models synthesis in d-q axes. A number of
models are given in the final developed form. The procedure and the
novel models are verified by a critical application to prove the
validity of the method and the equivalence between all developed
models is reported. Advantages of some of the models over the
existing ones and their applicability are discussed.