Abstract: This paper considers the design of Dual Proportional-
Integral (DPI) Load Frequency Control (LFC), using gravitational
search algorithm (GSA). The design is carried out for nonlinear
hydrothermal power system where generation rate constraint (GRC)
and governor dead band are considered. Furthermore, time delays
imposed by governor-turbine, thermodynamic process, and
communication channels are investigated. GSA is utilized to search
for optimal controller parameters by minimizing a time-domain based
objective function. GSA-based DPI has been compared to Ziegler-
Nichols based PI, and Genetic Algorithm (GA) based PI controllers
in order to demonstrate the superior efficiency of the proposed
design. Simulation results are carried for a wide range of operating
conditions and system parameters variations.
Abstract: Current transformers are an integral part of power
system because it provides a proportional safe amount of current for
protection and measurement applications. However, when the power
system experiences an abnormal situation leading to huge current
flow, then this huge current is proportionally injected to the
protection and metering circuit. Since the protection and metering
equipment’s are designed to withstand only certain amount of current
with respect to time, these high currents pose a risk to man and
equipment. Therefore, during such instances, the CT saturation
characteristics have a huge influence on the safety of both man and
equipment and on the reliability of the protection and metering
system. This paper shows the effect of burden on the Accuracy Limiting
factor/ Instrument security factor of current transformers and the
change in saturation characteristics of the CT’s. The response of the
CT to varying levels of overcurrent at different connected burden will
be captured using the data acquisition software LabVIEW. Analysis
is done on the real time data gathered using LabVIEW. Variation of
current transformer saturation characteristics with changes in burden
will be discussed.
Abstract: In this paper we present the design of an optical
device based on a Herriott multi-pass cell fabricated on a small sized
acrylic slab for heat flux measurements using the deflection of a laser
beam propagating inside the cell. The beam deflection is produced by
the heat flux conducted to the acrylic slab due to a gradient in the
refractive index. The use of a long path cell as the sensitive element
in this measurement device, gives the possibility of high sensitivity
within a small size device. We present the optical design as well as
some experimental results in order to validate the device’s operation
principle.
Abstract: Multiphase Induction Machine (IM) is normally
controlled using rotor field oriented vector control. Under phase(s)
loss, the machine currents can be optimally controlled to satisfy
certain optimization criteria. In this paper we discuss the performance
of double manifold sliding mode observer (DM-SMO) in Sensorless
control of multiphase induction machine under unsymmetrical
condition (one phase loss). This observer is developed using the IM
model in the stationary reference frame. DM-SMO is constructed by
adding extra feedback term to conventional single mode sliding mode
observer (SM-SMO) which proposed in many literature. This leads to
a fully convergent observer that also yields an accurate estimate of
the speed and stator currents. It will be shown by the simulation
results that the estimated speed and currents by the method are very
well and error between real and estimated quantities is negligible.
Also parameter sensitivity analysis shows that this method is rather
robust against parameter variation.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: Home Energy Management System (HEMS), which makes the residential consumers, contribute to the demand response is attracting attention in recent years. An aim of HEMS is to minimize their electricity cost by controlling the use of their appliances according to electricity price. The use of appliances in HEMS may be affected by some conditions such as external temperature and electricity price. Therefore, the user’s usage pattern of appliances should be modeled according to the external conditions, and the resultant usage pattern is related to the user’s comfortability on use of each appliances. This paper proposes a methodology to model the usage pattern based on the historical data with the copula function. Through copula function, the usage range of each appliance can be obtained and is able to satisfy the appropriate user’s comfort according to the external conditions for next day. Within the usage range, an optimal scheduling for appliances would be conducted so as to minimize an electricity cost with considering user’s comfort. Among the home appliance, electric heater (EH) is a representative appliance, which is affected by the external temperature. In this paper, an optimal scheduling algorithm for an electric heater (EH) is addressed based on the method of branch and bound. As a result, scenarios for the EH usage are obtained according to user’s comfort levels and then the residential consumer would select the best scenario. The case study shows the effects of the proposed algorithm compared with the traditional operation of the EH, and it represents impacts of the comfort level on the scheduling result.
Abstract: This paper presents a speed estimation scheme based
on second-order sliding-mode Super Twisting Algorithm (STA) and
Model Reference Adaptive System (MRAS) estimation theory for
Sensorless control of multiphase induction machine. A stator current
observer is designed based on the STA, which is utilized to take the
place of the reference voltage model of the standard MRAS
algorithm. The observer is insensitive to the variation of rotor
resistance and magnetizing inductance when the states arrive at the
sliding mode. Derivatives of rotor flux are obtained and designed as
the state of MRAS, thus eliminating the integration. Compared with
the first-order sliding-mode speed estimator, the proposed scheme
makes full use of the auxiliary sliding-mode surface, thus alleviating
the chattering behavior without increasing the complexity. Simulation
results show the robustness and effectiveness of the proposed
scheme.
Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: Lots of motors have been being used in industry.
Therefore many researchers have studied about the failure diagnosis of
motors. In this paper, the effect of measuring environment for
diagnosis of gear fault connected to a motor shaft is studied. The fault
diagnosis is executed through the comparison of normal gear and
abnormal gear. The measured FFT data are compared with the normal
data and analyzed for q-axis current, noise and vibration. For bad and
good environment, the diagnosis results are compared. From these, it
is shown that the bad measuring environment may not be able to detect
exactly the motor gear fault. Therefore it is emphasized that the
measuring environment should be carefully prepared.
Abstract: Piezoelectric actuator is treated as RC load when it is
modeled electrically. For some piezoelectric actuator applications,
arbitrary voltage is required to actuate. Especially for unidirectional
arbitrary voltage driving like as sine wave, some special inverter with
circuit that can charge and discharge the capacitive energy can be
used. In this case, the difference between power supply level and the
object voltage level for RC load is varied. Because the control gain is
constant, the controlled output is not uniform according to the voltage
difference. In this paper, for charge and discharge circuit for
unidirectional arbitrary voltage driving for piezoelectric actuator, the
controller gain is controlled according to the voltage difference. With
the proposed simple idea, the load voltage can have controlled
smoothly although the voltage difference is varied. The
appropriateness is proved from the simulation of the proposed circuit.
Abstract: This paper describes a sliding mode controller for
autonomous underwater vehicles (AUVs). The dynamic of AUV
model is highly nonlinear because of many factors, such as
hydrodynamic drag, damping, and lift forces, Coriolis and centripetal
forces, gravity and buoyancy forces, as well as forces from thruster.
To address these difficulties, a nonlinear sliding mode controller is
designed to approximate the nonlinear dynamics of AUV and
improve trajectory tracking. Moreover, the proposed controller can
profoundly attenuate the effects of uncertainties and external
disturbances in the closed-loop system. Using the Lyapunov theory
the boundedness of AUV tracking errors and the stability of the
proposed control system are also guaranteed. Numerical simulation
studies of an AUV are included to illustrate the effectiveness of the
presented approach.
Abstract: Mineral oil is commonly used for high voltage
transformer insulation. The insulation quality of mineral oil is
affecting the operation process of high voltage transformer. There are
many contaminations which could decrease the insulation quality of
mineral oil. One of them is water. This research talks about the effect
of water content on dielectric properties, physic properties, and
partial discharge pattern on mineral oil. Samples were varied with 10
varieties of water content value. And then all samples would be tested
to measure the dielectric properties, physic properties, and partial
discharge pattern. The result of this research showed that an
increment of water content value would decrease the insulation
quality of mineral oil.
Abstract: This study and the field test comparisons were carried
out on the Algerian Derguna – Setif transmission systems. The
transmission line of normal voltage 225 kV is 65 km long,
transported and uses twin bundle conductors protected with two
shield wires of transposed galvanized steel. An iterative finite-element method is used to solve Poisons
equation. Two algorithms are proposed for satisfying the current
continuity condition and updating the space-charge density. A new approach to the problem of corona discharge in
transmission system has been described in this paper. The effect of
varying the configurations and wires number is also investigated. The
analysis of this steady is important in the design of HVDC
transmission lines. The potential and electric field have been
calculating in locations singular points of the system.
Abstract: A mixed method for model order reduction is
presented in this paper. The denominator polynomial is derived by
matching both Markov parameters and time moments, whereas
numerator polynomial derivation and error minimization is done
using Genetic Algorithm. The efficiency of the proposed method can
be investigated in terms of closeness of the response of reduced order
model with respect to that of higher order original model and a
comparison of the integral square error as well.
Abstract: This paper presents the advantages of fuzzy control use in technological processes control. The paper presents a real application of the Linguistic Fuzzy-Logic Control, developed at the University of Ostrava for the control of physical models in the Intelligent Systems Laboratory. The paper presents an example of a sensitive non-linear model, such as a magnetic levitation model and obtained results which show how modern information technologies can help to solve actual technical problems. A special method based on the LFLC controller with partial components is presented in this paper followed by the method of automatic context change, which is very helpful to achieve more accurate control results. The main advantage of the used system is its robustness in changing conditions demonstrated by comparing with conventional PID controller. This technology and real models are also used as a background for problem-oriented teaching, realized at the department for master students and their collaborative as well as individual final projects.
Abstract: In this paper, the unstable angle of attack of a
FOXTROT aircraft is controlled by using Genetic Algorithm based
flight controller and the result is compared with the conventional
techniques like Tyreus-Luyben (TL), Ziegler-Nichols (ZN) and
Interpolation Rule (IR) for tuning the PID controller. In addition, the
performance indices like Mean Square Error (MSE), Integral Square
Error (ISE), and Integral Absolute Time Error (IATE) etc. are
improved by using Genetic Algorithm. It was established that the
error by using GA is very less as compared to the conventional
techniques thereby improving the performance indices of the
dynamic system.
Abstract: The research on thermoelectric has been a blooming field of research for the latest decade, owing to large amount of heat source available to be harvested, being eco-friendly and static in operation. This paper provides the performance of thermoelectric generator (TEG) with bulk material of bismuth telluride, Bi2Te3. Later, the performance of the TEGs is evaluated by considering attaching the TEGs on a plastic (polyethylene sheet) in contrast to the common method of attaching the TEGs on the metal surface.
Abstract: The increase in electric power demand in face of
environmental issues has intensified the participation of renewable
energy sources such as photovoltaics, in the energy matrix of various
countries. Due to their operational characteristics, they can generate
time-varying harmonic and inter-harmonic distortions. For this
reason, the application of methods of measurement based on
traditional Fourier analysis, as proposed by IEC 61000-4-7, can
provide inaccurate results. Considering the aspects mentioned herein,
came the idea of the development of this work which aims to present
the results of a comparative evaluation between a methodology
arising from the combination of the Prony method with the Kalman
filter and another method based on the IEC 61000-4-30 and IEC
61000-4-7 standards. Employed in this study were synthetic signals
and data acquired through measurements in a 50kWp photovoltaic
installation.
Abstract: Brushless DC motors (BLDC) are widely used in
industrial areas. The BLDC motors are driven either by indirect ACAC
converters or by direct AC-AC converters. Direct AC-AC
converters i.e. matrix converters are used in this paper to drive the
three phase BLDC motor and it eliminates the bulky DC link energy
storage element. A matrix converter converts the AC power supply to
an AC voltage of variable amplitude and variable frequency. A
control technique is designed to generate the switching pulses for the
three phase matrix converter. For the control of speed of the BLDC
motor a separate PI controller and Fuzzy Logic Controller (FLC) are
designed and a hysteresis current controller is also designed for the
control of motor torque. The control schemes are designed and tested
separately. The simulation results of both the schemes are compared
and contrasted in this paper. The results show that the fuzzy logic
control scheme outperforms the PI control scheme in terms of
dynamic performance of the BLDC motor. Simulation results are
validated with the experimental results.
Abstract: Wavelength Division Multiplexing (WDM)
technology is the most promising technology for the proper
utilization of huge raw bandwidth provided by an optical fiber. One
of the key problems in implementing the all-optical WDM network is
the packet contention. This problem can be solved by several
different techniques. In time domain approach the packet contention
can be reduced by incorporating Fiber Delay Lines (FDLs) as optical
buffer in the switch architecture. Different types of buffering
architectures are reported in literatures. In the present paper a
comparative performance analysis of three most popular FDL
architectures are presented in order to obtain the best contention
resolution performance. The analysis is further extended to consider
the effect of different fiber non-linearities on the network
performance.