Abstract: At the present work, highly transparent strip type
quasi-solid state dye-sensitized solar cells (DSSCs) were fabricated
through inkjet printing using nanocomposite TiO2 inks as raw
materials and tested under outdoor illumination conditions. The cells,
which can be considered as the structural units of large area modules,
were fully characterized electrically and electrochemically and after
the evaluation of the received results a large area DSSC module was
manufactured. The module design was a sandwich Z-interconnection
where the working electrode is deposited on one conductive glass and
the counter electrode on a second glass. Silver current collective
fingers were printed on the conductive glasses to make the internal
electrical connections and the adjacent cells were connected in series
and finally insulated using a UV curing resin to protect them from the
corrosive (I-/I3-) redox couple of the electrolyte. Finally, outdoor tests
were carried out to the fabricated dye-sensitized solar module and its
performance data were collected and assessed.
Abstract: Measuring the Electrocardiogram (ECG) signal is an
essential process for the diagnosis of the heart diseases. The ECG
signal has the information of the degree of how much the heart
performs its functions. In medical diagnosis and treatment systems,
Decision Support Systems processing the ECG signal are being
developed for the use of clinicians while medical examination. In this
study, a modular wireless ECG (WECG) measuring and recording
system using a single board computer and e-Health sensor platform
is developed. In this designed modular system, after the ECG signal
is taken from the body surface by the electrodes first, it is filtered and
converted to digital form. Then, it is recorded to the health database
using Wi-Fi communication technology. The real time access of the
ECG data is provided through the internet utilizing the developed
web interface.
Abstract: The nickel-manganese (Ni-Mn) alloy coating prepared
from DC electrodeposition process in sulphamate bath was studied.
The effects of process parameters, such as current density and
electrolyte composition, on the cathodic current efficiency,
microstructure, internal stress and mechanical properties were
investigated. Because of its crucial effect on the application to the
electroforming of microelectronic components, the development of
low internal stress coating with high leveling power was emphasized.
It was found that both the coating’s manganese content and the
cathodic current efficiency increased with the raise in current density.
In addition, the internal stress of the deposited coating showed
compressive nature at low current densities while changed to tensile
one at higher current densities. Moreover, the metallographic
observation, X-ray diffraction measurement, and polarization curve
measurement were conducted. It was found that the Ni-Mn coating
consisted of nano-sized columnar grains and the maximum hardness of
the coating was associated with (111) preferred orientation in the
microstructure. The grain size was refined along with the increase in
the manganese content of the coating, which accordingly, raised its
hardness and resistance to annealing softening. In summary, the
Ni-Mn coating prepared at lower current density of 1-2 A/dm2 had low
internal stress, high leveling power, and better corrosion resistance.
Abstract: Nine Degrees of Freedom (9 DOF) systems are
already in development in many areas. In this paper, an integrated
pressure sensor is proposed that will make use of an already existing
monolithic 9 DOF inertial MEMS platform. Capacitive pressure
sensors can suffer from limited sensitivity for a given size of
membrane. This novel pressure sensor design increases the sensitivity
by over 5 times compared to a traditional array of square diaphragms
while still fitting within a 2 mm x 2 mm chip and maintaining a fixed
static capacitance. The improved design uses one large diaphragm
supported by pillars with fixed electrodes placed above the areas of
maximum deflection. The design optimization increases the
sensitivity from 0.22 fF/kPa to 1.16 fF/kPa. Temperature sensitivity
was also examined through simulation.
Abstract: Transparent nickel doped cobalt sulfide was fabricated
on a SnO2:F electrode and tested as an efficient electrocatalyst and as
an alternative to the expensive platinum counter electrode. In order to
investigate how this electrode could affect the electrical
characteristics of a dye-sensitized solar cell, we manufactured cells
with the same TiO2 photoanode sensitized with dye (N719) and
employing the same quasi-solid electrolyte, altering only the counter
electrode used. The cells were electrically and electrochemically
characterized and it was observed that the ones with the Ni doped
CoS2 outperformed the efficiency of the cells with the Pt counter
electrode (3.76% and 3.44% respectively). Particularly, the higher
efficiency of the cells with the Ni doped CoS2 counter electrode (CE)
is mainly because of the enhanced photocurrent density which is
attributed to the enhanced electrocatalytic ability of the CE and the
low charge transfer resistance at the CE/electrolyte interface.
Abstract: Zn alloy and composite coatings are widely used in
buildings and structures, automobile and fasteners industries to
protect steel component from corrosion. In this paper, Zn-Ni-Al2O3
nanocomposite coatings were electrodeposited on mild steel using a
novel sol enhanced electroplating method. In this method, transparent
Al2O3 sol was added into the acidic Zn-Ni bath to produced Zn-Ni-
Al2O3 nanocomposite coatings. The effect of alumina sol on the
electrodeposition process, and coating properties was investigated
using cyclic voltammetry, XRD, ESEM and Tafel test. Results from
XRD tests showed that the structure of all coatings was single γ-
Ni5Zn21 phase. Cyclic voltammetry results showed that the
electrodeposition overpotential was lower in the presence of alumina
sol in the bath, and caused the reduction potential of Zn-Ni to shift to
more positive values. Zn-Ni-Al2O3 nanocomposite coatings produced
more uniform and compact deposits, with fine grained microstructure
when compared to Zn-Ni coatings. The corrosion resistance of Zn-Ni
coatings was improved significantly by incorporation of alumina
nanoparticles into the coatings.
Abstract: Neural activity in the human brain starts from the
early stages of prenatal development. This activity or signals
generated by the brain are electrical in nature and represent not only
the brain function but also the status of the whole body. At the
present moment, three methods can record functional and
physiological changes within the brain with high temporal resolution
of neuronal interactions at the network level: the
electroencephalogram (EEG), the magnet oencephalogram (MEG),
and functional magnetic resonance imaging (fMRI); each of these has
advantages and shortcomings. EEG recording with a large number of
electrodes is now feasible in clinical practice. Multichannel EEG
recorded from the scalp surface provides very valuable but indirect
information about the source distribution. However, deep electrode
measurements yield more reliable information about the source
locations intracranial recordings and scalp EEG are used with the
source imaging techniques to determine the locations and strengths of
the epileptic activity. As a source localization method, Low
Resolution Electro-Magnetic Tomography (LORETA) is solved for
the realistic geometry based on both forward methods, the Boundary
Element Method (BEM) and the Finite Difference Method (FDM). In
this paper, we review the findings EEG- LORETA about epilepsy.
Abstract: Since 1920, the industry has almost completely
changed the rivets production techniques for the manufacture of
permanent welding join production of structures and manufacture of
other products. The welding arc is the process more widely used in
industries. This is accomplished by the heat of an electric arc which
melts the base metal while the molten metal droplets are transferred
through the arc to the welding pool, protected from the atmosphere
by a gas curtain. The GMAW (Gas metal arc welding) process is
influenced by variables such as: current, polarity, welding speed,
electrode: extension, position, moving direction; type of joint,
welder's ability, among others. It is remarkable that the knowledge
and control of these variables are essential for obtaining satisfactory
quality welds, knowing that are interconnected so that changes in one
of them requiring changes in one or more of the other to produce the
desired results. The optimum values are affected by the type of base
metal, the electrode composition, the welding position and the quality
requirements. Thus, this paper proposes a new methodology, adding
the variable vibration through a mechanism developed for GMAW
welding, in order to improve the mechanical and metallurgical
properties which does not affect the ability of the welder and enables
repeatability of the welds made. For confirmation metallographic
analysis and mechanical tests were made.
Abstract: In this work new macroporous Ni electrodes modified
with Au nanoparticles for hydrogen production have been developed.
The supporting macroporous Ni electrodes have been obtained by
means of the electrodeposition at high current densities. Then, the Au
nanoparticles were synthesized and added to the electrode surface.
The electrocatalytic behaviour of the developed electrocatalysts was
studied by means of pseudo-steady-state polarization curves,
electrochemical impedance spectroscopy (EIS) and hydrogen
discharge curves. The size of the Au synthetized nanoparticles shows
a monomodal distribution, with a very sharp band between 10 and 50
nm. The characteristic parameters d10, d50 and d90 were 14, 20 and
31 nm respectively. From Tafel polarization data has been concluded
that the Au nanoparticles improve the catalytic activity of the
developed electrodes towards the HER respect to the macroporous Ni
electrodes. EIS permits to obtain the electrochemically active area by
means of the roughness factor value. All the developed electrodes
show roughness factor values in the same order of magnitude. From
the activation energy results it can be concluded that the Au
nanoparticles improve the intrinsic catalytic activity of the
macroporous Ni electrodes.
Abstract: Durability of Membrane Electrode Assembly for
Proton Exchange Membrane Fuel Cells was evaluated in both steady
state and accelerated decay modes. Steady state mode was carried out
at constant current of 800mA/cm2 for 2500 hours using air as cathode
feed and pure hydrogen as anode feed. The degradation of the cell
voltage was 0.015V after such 2500 hrs operation. The degradation
rate was therefore calculated to be 6uV/hr. Continuously Vigorous
fluctuation of the cell voltage, which was switched between OCV and
0.2V, was employed for the accelerated decay mode. No obvious
change in performance of the MEA was observed after 10000 cycles
of such operation.
Abstract: Experimental investigations of the DC electric field effect on thermal decomposition of biomass, formation of the axial flow of volatiles (CO, H2, CxHy), mixing of volatiles with swirling airflow at low swirl intensity (S ≈ 0.2-0.35), their ignition and on formation of combustion dynamics are carried out with the aim to understand the mechanism of electric field influence on biomass gasification, combustion of volatiles and heat energy production. The DC electric field effect on combustion dynamics was studied by varying the positive bias voltage of the central electrode from 0.6 kV to 3 kV, whereas the ion current was limited to 2 mA. The results of experimental investigations confirm the field-enhanced biomass gasification with enhanced release of volatiles and the development of endothermic processes at the primary stage of thermochemical conversion of biomass determining the field-enhanced heat energy consumption with the correlating decrease of the flame temperature and heat energy production at this stage of flame formation. Further, the field-enhanced radial expansion of the flame reaction zone correlates with a more complete combustion of volatiles increasing the combustion efficiency by 3% and decreasing the mass fraction of CO, H2 and CxHy in the products, whereas by 10% increases the average volume fraction of CO2 and the heat energy production downstream the combustor increases by 5-10%
Abstract: Electrodeposition is a simple and economic technique
for precision coating of different shaped substrates with pure metal,
alloy or composite films. Dc electrodeposition was used to produce
Cr, Co-Cr and Co-Cr/TiO2 nano-composite coatings from Cr(III)
based electrolytes onto 316L SS substrates. The effects of TiO2 nanoparticles
concentration on co-deposition of these particles along with
Cr content and microhardness of the coatings were investigated.
Morphology of the Cr, Co-Cr and Co-Cr/TiO2 coatings besides their
tribological behavior were studied. The results showed that increment
of TiO2 nanoparticles concentration from 0 to 30 g L-1 in the bath
increased their co-deposition and Cr content of the coatings from 0 to
3.5 wt.% and from 23.7 to 31.2 wt.%, respectively. Microhardness of
Cr coating was about 920 Hv which was higher than Co-Cr and even
Co-Cr/TiO2 films. Microhardness of Co-Cr and Co-Cr/TiO2 coatings
were improved by increasing their Cr and TiO2 content. All the
coatings had nodular morphology and contained microcracks.
Nodules sizes and the number of microcracks in the alloy and
composite coatings were lower than the Cr film. Wear results
revealed that the Co-Cr/TiO2 coating had the lowest wear loss
between all the samples, while the Cr film had the worst wear
resistance.
Abstract: This paper presents the design and characterization of
analog readout interface circuits for ion sensitive field effect
transistor (ISFET) and ion selective electrode (ISE) based sensor.
These interface circuits are implemented using MIMOS’s 0.35um
CMOS technology and experimentally characterized under 24-leads
QFN package. The characterization evaluates the circuit’s
functionality, output sensitivity and output linearity. Commercial
sensors for both ISFET and ISE are employed together with glass
reference electrode during testing. The test result shows that the
designed interface circuits manage to readout signals produced by
both sensors with measured sensitivity of ISFET and ISE sensor are
54mV/pH and 62mV/decade, respectively. The characterized output
linearity for both circuits achieves above 0.999 Rsquare. The readout
also has demonstrated reliable operation by passing all qualifications
in reliability test plan.
Abstract: High density electrical prospecting has been widely
used in groundwater investigation, civil engineering and
environmental survey. For efficient inversion, the forward modeling
routine, sensitivity calculation, and inversion algorithm must be
efficient. This paper attempts to provide a brief summary of the past
and ongoing developments of the method. It includes reviews of the
procedures used for data acquisition, processing and inversion of
electrical resistivity data based on compilation of academic literature.
In recent times there had been a significant evolution in field survey
designs and data inversion techniques for the resistivity method. In
general 2-D inversion for resistivity data is carried out using the
linearized least-square method with the local optimization technique
.Multi-electrode and multi-channel systems have made it possible to
conduct large 2-D, 3-D and even 4-D surveys efficiently to resolve
complex geological structures that were not possible with traditional
1-D surveys. 3-D surveys play an increasingly important role in very
complex areas where 2-D models suffer from artifacts due to off-line
structures. Continued developments in computation technology, as
well as fast data inversion techniques and software, have made it
possible to use optimization techniques to obtain model parameters to
a higher accuracy. A brief discussion on the limitations of the
electrical resistivity method has also been presented.
Abstract: The objective of this work is to study the effect of two
key factors - external magnetic field and applied current density
during template-based electrodeposition of nickel nanowires using an
electrode distance of 20 mm. Morphology, length, crystallite size and
crystallographic characterization of the grown nickel nanowires at an
electrode distance of 20mm are presented. For this electrode distance
of 20 mm, these two key electrodeposition factors when coupled was
found to reduce crystallite size with a higher growth length and
preferred orientation of Ni crystals. These observed changes can be
inferred to be due to coupled interaction forces induced by the
intensity of applied electric field (current density) and external
magnetic field known as magnetohydrodynamic (MHD) effect during
the electrodeposition process.
Abstract: In Jordan having deficit atmospheric precipitation, an
increase in water demand occurs during summer months. Jordan can
be regarded with a relatively high potential for wastewater recycling
and reuse. The main purpose of this paper was to investigate the
removal of total suspended solids (TSS) and chemical oxygen
demand (COD) for olive mill wastewater (OMW) by
electrocoagulation (EC) process. In the combination of
electrocoagulation by using coupled iron–aluminum electrodes, the
optimum working pH was found to be around 6. Results indicated
that the electrocoagulation process allowed removal of TSS and COD
of about 82.5% and 47.5%, respectively at 45 mA/cm2 after 70
minutes by using coupled iron–aluminum electrodes. It was
demonstrated that the maximum TSS and COD removals were
obtained at some optimum experimental parameters for current
density, pH, and reaction time.
Abstract: Electroencephalogram (EEG) is a noninvasive
technique that registers signals originating from the firing of neurons
in the brain. The Emotiv EEG Neuroheadset is a consumer product
comprised of 14 EEG channels and was used to record the reactions
of the neurons within the brain to two forms of stimuli in 10
participants. These stimuli consisted of auditory and visual formats
that provided directions of ‘right’ or ‘left.’ Participants were
instructed to raise their right or left arm in accordance with the
instruction given. A scenario in OpenViBE was generated to both
stimulate the participants while recording their data. In OpenViBE,
the Graz Motor BCI Stimulator algorithm was configured to govern
the duration and number of visual stimuli. Utilizing EEGLAB under
the cross platform MATLAB®, the electrodes most stimulated during
the study were defined. Data outputs from EEGLAB were analyzed
using IBM SPSS Statistics® Version 20. This aided in determining
the electrodes to use in the development of a brain-machine interface
(BMI) using real-time EEG signals from the Emotiv EEG
Neuroheadset. Signal processing and feature extraction were
accomplished via the Simulink® signal processing toolbox. An
Arduino™ Duemilanove microcontroller was used to link the Emotiv
EEG Neuroheadset and the right and left Mecha TE™ Hands.
Abstract: A nanocrystalline thin film of ZnSe was successfully
electrodeposited on copper substrate using a non-aqueous solution
and subsequently annealed in air at 400°C. XRD analysis indicates
the polycrystalline deposit of (111) plane in both the cases. The
sharpness of the peak increases due to annealing of the film and
average grain size increases to 20 nm to 27nm. SEM photograph
indicate that grains are uniform and densely distributed over the
surface. Annealing increases the average grain size by 20%. The EDS
spectroscopy shows the ratio of Zn & Se is 1.1 in case of annealed
film. AFM analysis indicates the average roughness of the film
reduces from 181nm to 165nm due to annealing of the film. The
bandgap also decreases from 2.71eV to 2.62eV.
Abstract: This paper outlines the basic installation and operation of magnetic inductive flow velocity sensors on large underground cooling water pipelines. Research on the effects of cathodic protection as well as into other factors that might influence the overall performance of the meter is presented in this paper. The experiments were carried out on an immersion type magnetic meter specially used for flow measurement of cooling water pipeline. An attempt has been made in this paper to outline guidelines that can ensure accurate measurement related to immersion type magnetic meters on underground pipelines.
Abstract: In order to detect and quantify the phenolic contents
of a wastewater with biosensors, two working electrodes based on
modified Poly(Pyrrole) films were fabricated. Enzyme horseradish
peroxidase was used as biomolecule of the prepared electrodes.
Various phenolics were tested at the biosensor. Phenol detection was
realized by electrochemical reduction of quinones produced by
enzymatic activity. Analytical parameters were calculated and the
results were compared with each other.