Abstract: In this work, the influence of temperature on the
different parameters of solar cells based on organic semiconductors
are studied. The short circuit current Isc increases so monotonous
with temperature and then saturates to a maximum value before
decreasing at high temperatures. The open circuit voltage Vco
decreases linearly with temperature. The fill factor FF and efficiency,
which are directly related with Isc and Vco follow the variations of
the letters. The phenomena are explained by the behaviour of the
mobility which is a temperature activated process.
Abstract: Power transformers are among the most important and
expensive equipments in the electric power systems. Consequently
the transformer protection is an essential part of the system
protection. This paper presents a new method for locating
transformer winding faults such as turn-to-turn, turn-to-core, turn-totransformer
body, turn-to-earth, and high voltage winding to low
voltage winding. In this study the current and voltage signals of input
and output terminals of the transformer are measured, which the
Fourier transform of measured signals and harmonic analysis
determine the fault's location.
Abstract: One of the most important power quality issues is voltage flicker. Nowadays this issue also impacts the power system all over the world. The fact of the matter is that the more and the larger capacity of wind generator has been installed. Under unstable wind power situation, the variation of output current and voltage have caused trouble to voltage flicker. Hence, the major purpose of this study is to analyze the impact of wind generator on voltage flicker of power system. First of all, digital simulation and analysis are carried out based on wind generator operating under various system short circuit capacity, impedance angle, loading, and power factor of load. The simulation results have been confirmed by field measurements.
Abstract: The distance protection mainly the impedance relay which is considered as the main protection for transmission lines can be subjected to impedance measurement error which is, mainly, due to the fault resistance and to the power fluctuation. Thus, the impedance relay may not operate for a short circuit at the far end of the protected line (case of the under reach) or operates for a fault beyond its protected zone (case of overreach). In this paper, an approach to fault detection by a distance protection, which distinguishes between the faulty conditions and the effect of overload operation mode, has been developed. This approach is based on the symmetrical components; mainly the negative sequence, and it is taking into account both the effect of fault resistance and the overload situation which both have an effect upon the reliability of the protection in terms of dependability for the former and security for the latter.
Abstract: This paper presents an exact solution and a finite element method (FEM) for a Piezoceramic Rod under static load. The cylindrical rod is made from polarized ceramics (piezoceramics) with axial poling. The lateral surface of the rod is traction-free and is unelectroded. The two end faces are under a uniform normal traction. Electrically, the two end faces are electroded with a circuit between the electrodes, which can be switched on or off. Two cases of open and shorted electrodes (short circuit and open circuit) will be considered. Finally, a finite element model will be used to compare the results with an exact solution. The study uses ABAQUS (v.6.7) software to derive the finite element model of the ceramic rod.
Abstract: The electrical substation components are often subject to degradation due to over-voltage or over-current, caused by a short circuit or a lightning. A particular interest is given to the circuit breaker, regarding the importance of its function and its dangerous failure. This component degrades gradually due to the use, and it is also subject to the shock process resulted from the stress of isolating the fault when a short circuit occurs in the system. In this paper, based on failure mechanisms developments, the wear out of the circuit breaker contacts is modeled. The aim of this work is to evaluate its reliability and consequently its residual lifetime. The shock process is based on two random variables such as: the arrival of shocks and their magnitudes. The arrival of shocks was modeled using homogeneous Poisson process (HPP). By simulation, the dates of short-circuit arrivals were generated accompanied with their magnitudes. The same principle of simulation is applied to the amount of cumulative wear out contacts. The objective reached is to find the formulation of the wear function depending on the number of solicitations of the circuit breaker.
Abstract: In this work we present the modelling of the induction
machine, taking into consideration the stator defects of the induction
machine. It is based on the theory of electromagnetic coupling of
electrical circuits. In fact, for the modelling of stationary defects such
as short circuit between turns in the same phase, we introduce only
in the matrix the coefficients of resistance and inductance of stator
and in the mutual inductance stator-rotor. These coefficients take
account the number of turns in short-circuit deducted from the total
number of turns in the same phase; in this way we obtain the number
of useful turns. In addition, all these faults involved, will be used for
the creation of the database that will be used to develop an automated
system failures of the induction machine.
Abstract: The paper presents an investigation in to the effect of neural network predictive control of UPFC on the transient stability performance of a multimachine power system. The proposed controller consists of a neural network model of the test system. This model is used to predict the future control inputs using the damped Gauss-Newton method which employs ‘backtracking’ as the line search method for step selection. The benchmark 2 area, 4 machine system that mimics the behavior of large power systems is taken as the test system for the study and is subjected to three phase short circuit faults at different locations over a wide range of operating conditions. The simulation results clearly establish the robustness of the proposed controller to the fault location, an increase in the critical clearing time for the circuit breakers, and an improved damping of the power oscillations as compared to the conventional PI controller.
Abstract: The resistive-inductive-capacitive behavior of long
interconnects which are driven by CMOS gates are presented in this
paper. The analysis is based on the ¤Ç-model of a RLC load and is
developed for submicron devices. Accurate and analytical
expressions for the output load voltage, the propagation delay and the
short circuit power dissipation have been proposed after solving a
system of differential equations which accurately describe the
behavior of the circuit. The effect of coupling capacitance between
input and output and the short circuit current on these performance
parameters are also incorporated in the proposed model. The
estimated proposed delay and short circuit power dissipation are in
very good agreement with the SPICE simulation with average
relative error less than 6%.
Abstract: Short circuit currents plays a vital role in influencing the design and operation of equipment and power system and could not be avoided despite careful planning and design, good maintenance and thorough operation of the system. This paper discusses the short circuit analysis conducted in KSO briefly comprising of its significances, methods and results. A result sample of the analysis based on a single transformer is detailed in this paper. Furthermore, the results of the analysis and its significances were also discussed and commented.
Abstract: This paper analyses the torsional efforts in gas turbine-generator shafts caused by high speed automatic reclosing of transmission lines. This issue is especially important for cases of three phase short circuit and unsuccessful reclosure of lines in the vicinity of the thermal plant. The analysis was carried out for the thermal plant TERMOPERNAMBUCO located on Northeast region of Brazil. It is shown that stress level caused by lines unsuccessful reclosing can be several times higher than terminal three-phase short circuit. Simulations were carried out with detailed shaft torsional model provided by machine manufacturer and with the “Alternative Transient Program – ATP" program [1]. Unsuccessful three phase reclosing for selected lines in the area closed to the plant indicated most critical cases. Also, reclosing first the terminal next to the gas turbine gererator will lead also to the most critical condition. Considering that the values of transient torques are very sensible to the instant of reclosing, simulation of unsuccessful reclosing with statistics ATP switch were carried out for determination of most critical transient torques for each section of the generator turbine shaft.
Abstract: Preliminary studies on Kuwait high voltage
transmission system show significant increase in the short circuit
level at some of the grid substations and some generating stations.
This increase results from the growth in the power transmission
systems in size and complexity. New generating stations are expected
to be added to the system within the next few years. This paper
describes the study analysis performed to evaluate the available and
potential solutions to control SC levels in Kuwait power system. It
also presents a modified planning of the transmission network in
order to fulfill this task.
Abstract: To maximise furnace production it-s necessary to
optimise furnace control, with the objectives of achieving maximum
power input into the melting process, minimum network distortion
and power-off time, without compromise on quality and safety. This
can be achieved with on the one hand by an appropriate electrode
control and on the other hand by a minimum of AC transformer
switching.
Electrical arc is a stochastic process; witch is the principal cause
of power quality problems, including voltages dips, harmonic
distortion, unbalance loads and flicker. So it is difficult to make an
appropriate model for an Electrical Arc Furnace (EAF). The factors
that effect EAF operation are the melting or refining materials,
melting stage, electrode position (arc length), electrode arm control
and short circuit power of the feeder. So arc voltages, current and
power are defined as a nonlinear function of the arc length. In this
article we propose our own empirical function of the EAF and model,
for the mean stages of the melting process, thanks to the
measurements in the steel factory.
Abstract: This paper presents the impact study of apparent
reactance injected by series Flexible AC Transmission System
(FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the
measured impedance of a 400 kV single electrical transmission line
in the presence of phase to earth fault with fault resistance. The study
deals with an electrical transmission line of Eastern Algerian
transmission networks at Group Sonelgaz (Algerian Company of
Electrical and Gas) compensated by TCSR connected at midpoint of
the line. This compensator used to inject active and reactive powers
is controlled by three TCSR-s. The simulations results investigate the
impacts of the TCSR on the parameters of short circuit calculation
and parameters of measured impedance by distance relay in the
presence of earth fault for three cases study.
Abstract: The paper presents coupled electromagnetic and
thermal field analysis of busbar system (of rectangular cross-section
geometry) submitted to short circuit conditions. The laboratory model
was validated against both analytical solution and experimental
observations. The considered problem required the computation of
the detailed distribution of the power losses and the heat transfer
modes. In this electromagnetic and thermal analysis, different
definitions of electric busbar heating were considered and compared.
The busbar system is a three phase one and consists of aluminum,
painted aluminum and copper busbar. The solution to the coupled
field problem is obtained using the finite element method and the
QuickField™ program. Experiments have been carried out using two
different approaches and compared with computed results.
Abstract: An appropriate method for fault identification and classification on extra high voltage transmission line using discrete wavelet transform is proposed in this paper. The sharp variations of the generated short circuit transient signals which are recorded at the sending end of the transmission line are adopted to identify the fault. The threshold values involve fault classification and these are done on the basis of the multiresolution analysis. A comparative study of the performance is also presented for Discrete Fourier Transform (DFT) based Artificial Neural Network (ANN) and Discrete Wavelet Transform (DWT). The results prove that the proposed method is an effective and efficient one in obtaining the accurate result within short duration of time by using Daubechies 4 and 9. Simulation of the power system is done using MATLAB.