Abstract: There is a widespread changeover in the electrical power industry universally from old-style monopolistic outline towards a horizontally distributed competitive structure to come across the demand of rising consumption. When the transmission lines of derestricted system are incapable to oblige the entire service needs, the lines are overloaded or congested. The governor between customer and power producer is nominated as Independent System Operator (ISO) to lessen the congestion without obstructing transmission line restrictions. Among the existing approaches for congestion management, the frequently used approaches are reorganizing the generation and load curbing. There is a boundary for reorganizing the generators, and further loads may not be supplemented with the prevailing resources unless more private power producers are added in the system by considerably raising the cost. Hence, congestion is relaxed by appropriate Flexible AC Transmission Systems (FACTS) devices which boost the existing transfer capacity of transmission lines. The FACTs device, namely, Unified Power Flow Controller (UPFC) is preferred, and the correct placement of UPFC is more vital and should be positioned in the highly congested line. Hence, the weak line is identified by using power flow performance index with the new objective function with proposed hybrid Fish – Bee algorithm. Further, the location of UPFC at appropriate line reduces the branch loading and minimizes the voltage deviation. The power transfer capacity of lines is determined with and without UPFC in the identified congested line of IEEE 30 bus structure and the simulated results are compared with prevailing algorithms. It is observed that the transfer capacity of existing line is increased with the presented algorithm and thus alleviating the congestion.
Abstract: Flexible AC Transmission Systems (FACTS) is
granting a new group of advanced power electronic devices emerging
for enhancement of the power system performance. Unified Power
Flow Controller (UPFC) is a recent version of FACTS devices for
power system applications. The back-up energy supply system
incorporated with UPFC is providing a complete control of real and
reactive power at the same time and hence is competent to improve
the performance of an electrical power system. In this article, backup
energy supply unit such as superconducting magnetic energy storage
(SMES) is integrated with UPFC. In addition, comparative
exploration of UPFC–battery, UPFC–UC and UPFC–SMES
performance is evaluated through the vibrant simulation by using
MATLAB/Simulink software.
Abstract: FACTS devices are used to control the power flow, to
increase the transmission capacity and to optimize the stability of the
power system. One of the most widely used FACTS devices is
Unified Power Flow Controller (UPFC). The controller used in the
control mechanism has a significantly effects on controlling of the
power flow and enhancing the system stability of UPFC. According
to this, the capability of UPFC is observed by using different control
mechanisms based on P, PI, PID and fuzzy logic controllers (FLC) in
this study. FLC was developed by taking consideration of Takagi-
Sugeno inference system in the decision process and Sugeno-s
weighted average method in the defuzzification process. Case studies
with different operating conditions are applied to prove the ability of
UPFC on controlling the power flow and the effectiveness of
controllers on the performance of UPFC. PSCAD/EMTDC program
is used to create the FLC and to simulate UPFC model.
Abstract: The paper presents an investigation in to the effect of neural network predictive control of UPFC on the transient stability performance of a multimachine power system. The proposed controller consists of a neural network model of the test system. This model is used to predict the future control inputs using the damped Gauss-Newton method which employs ‘backtracking’ as the line search method for step selection. The benchmark 2 area, 4 machine system that mimics the behavior of large power systems is taken as the test system for the study and is subjected to three phase short circuit faults at different locations over a wide range of operating conditions. The simulation results clearly establish the robustness of the proposed controller to the fault location, an increase in the critical clearing time for the circuit breakers, and an improved damping of the power oscillations as compared to the conventional PI controller.
Abstract: In this paper the performance of unified power flow
controller is investigated in controlling the flow of po wer over the
transmission line. Voltage sources model is utilized to study the
behaviour of the UPFC in regulating the active, reactive power and
voltage profile. This model is incorporated in Newton Raphson
algorithm for load flow studies. Simultaneous method is employed
in which equations of UPFC and the power balance equations of
network are combined in to one set of non-linear algebraic equations.
It is solved according to the Newton raphson algorithm. Case studies
are carried on standard 5 bus network. Simulation is done in Matlab.
The result of network with and without using UPFC are compared in
terms of active and reactive power flows in the line and active and
reactive power flows at the bus to analyze the performance of UPFC.