Abstract: Lateral Geniculate Nucleus (LGN) is the relay center
in the visual pathway as it receives most of the input information
from retinal ganglion cells (RGC) and sends to visual cortex. Low
threshold calcium currents (IT) at the membrane are the unique
indicator to characterize this firing functionality of the LGN neurons
gained by the RGC input. According to the LGN functional
requirements such as functional mapping of RGC to LGN, the
morphologies of the LGN neurons were developed. During the
neurological disorders like glaucoma, the mapping between RGC and
LGN is disconnected and hence stimulating LGN electrically using
deep brain electrodes can restore the functionalities of LGN. A
computational model was developed for simulating the LGN neurons
with three predominant morphologies each representing different
functional mapping of RGC to LGN. The firings of action potentials
at LGN neuron due to IT were characterized by varying the
stimulation parameters, morphological parameters and orientation. A
wide range of stimulation parameters (stimulus amplitude, duration
and frequency) represents the various strengths of the electrical
stimulation with different morphological parameters (soma size,
dendrites size and structure). The orientation (0-1800) of LGN
neuron with respect to the stimulating electrode represents the angle
at which the extracellular deep brain stimulation towards LGN
neuron is performed. A reduced dendrite structure was used in the
model using Bush–Sejnowski algorithm to decrease the
computational time while conserving its input resistance and total
surface area. The major finding is that an input potential of 0.4 V is
required to produce the action potential in the LGN neuron which is
placed at 100 μm distance from the electrode. From this study, it can
be concluded that the neuroprostheses under design would need to
consider the capability of inducing at least 0.4V to produce action
potentials in LGN.
Abstract: This paper describes the development of a DNA-based
nanobiosensor to detect the dengue virus in mosquito using
electrically active magnetic (EAM) nanoparticles as concentrator and
electrochemical transducer. The biosensor detection encompasses
two sets of oligonucleotide probes that are specific to the dengue
virus: the detector probe labeled with the EAM nanoparticles and the
biotinylated capture probe. The DNA targets are double hybridized to
the detector and the capture probes and concentrated from
nonspecific DNA fragments by applying a magnetic field.
Subsequently, the DNA sandwiched targets (EAM-detector probe–
DNA target–capture probe-biotin) are captured on streptavidin
modified screen printed carbon electrodes through the biotinylated
capture probes. Detection is achieved electrochemically by measuring
the oxidation–reduction signal of the EAM nanoparticles. Results
indicate that the biosensor is able to detect the redox signal of the
EAM nanoparticles at dengue DNA concentrations as low as 10
ng/μl.
Abstract: Measuring the Electrocardiogram (ECG) signal is an
essential process for the diagnosis of the heart diseases. The ECG
signal has the information of the degree of how much the heart
performs its functions. In medical diagnosis and treatment systems,
Decision Support Systems processing the ECG signal are being
developed for the use of clinicians while medical examination. In this
study, a modular wireless ECG (WECG) measuring and recording
system using a single board computer and e-Health sensor platform
is developed. In this designed modular system, after the ECG signal
is taken from the body surface by the electrodes first, it is filtered and
converted to digital form. Then, it is recorded to the health database
using Wi-Fi communication technology. The real time access of the
ECG data is provided through the internet utilizing the developed
web interface.
Abstract: Nine Degrees of Freedom (9 DOF) systems are
already in development in many areas. In this paper, an integrated
pressure sensor is proposed that will make use of an already existing
monolithic 9 DOF inertial MEMS platform. Capacitive pressure
sensors can suffer from limited sensitivity for a given size of
membrane. This novel pressure sensor design increases the sensitivity
by over 5 times compared to a traditional array of square diaphragms
while still fitting within a 2 mm x 2 mm chip and maintaining a fixed
static capacitance. The improved design uses one large diaphragm
supported by pillars with fixed electrodes placed above the areas of
maximum deflection. The design optimization increases the
sensitivity from 0.22 fF/kPa to 1.16 fF/kPa. Temperature sensitivity
was also examined through simulation.
Abstract: Transparent nickel doped cobalt sulfide was fabricated
on a SnO2:F electrode and tested as an efficient electrocatalyst and as
an alternative to the expensive platinum counter electrode. In order to
investigate how this electrode could affect the electrical
characteristics of a dye-sensitized solar cell, we manufactured cells
with the same TiO2 photoanode sensitized with dye (N719) and
employing the same quasi-solid electrolyte, altering only the counter
electrode used. The cells were electrically and electrochemically
characterized and it was observed that the ones with the Ni doped
CoS2 outperformed the efficiency of the cells with the Pt counter
electrode (3.76% and 3.44% respectively). Particularly, the higher
efficiency of the cells with the Ni doped CoS2 counter electrode (CE)
is mainly because of the enhanced photocurrent density which is
attributed to the enhanced electrocatalytic ability of the CE and the
low charge transfer resistance at the CE/electrolyte interface.
Abstract: Neural activity in the human brain starts from the
early stages of prenatal development. This activity or signals
generated by the brain are electrical in nature and represent not only
the brain function but also the status of the whole body. At the
present moment, three methods can record functional and
physiological changes within the brain with high temporal resolution
of neuronal interactions at the network level: the
electroencephalogram (EEG), the magnet oencephalogram (MEG),
and functional magnetic resonance imaging (fMRI); each of these has
advantages and shortcomings. EEG recording with a large number of
electrodes is now feasible in clinical practice. Multichannel EEG
recorded from the scalp surface provides very valuable but indirect
information about the source distribution. However, deep electrode
measurements yield more reliable information about the source
locations intracranial recordings and scalp EEG are used with the
source imaging techniques to determine the locations and strengths of
the epileptic activity. As a source localization method, Low
Resolution Electro-Magnetic Tomography (LORETA) is solved for
the realistic geometry based on both forward methods, the Boundary
Element Method (BEM) and the Finite Difference Method (FDM). In
this paper, we review the findings EEG- LORETA about epilepsy.
Abstract: In this work new macroporous Ni electrodes modified
with Au nanoparticles for hydrogen production have been developed.
The supporting macroporous Ni electrodes have been obtained by
means of the electrodeposition at high current densities. Then, the Au
nanoparticles were synthesized and added to the electrode surface.
The electrocatalytic behaviour of the developed electrocatalysts was
studied by means of pseudo-steady-state polarization curves,
electrochemical impedance spectroscopy (EIS) and hydrogen
discharge curves. The size of the Au synthetized nanoparticles shows
a monomodal distribution, with a very sharp band between 10 and 50
nm. The characteristic parameters d10, d50 and d90 were 14, 20 and
31 nm respectively. From Tafel polarization data has been concluded
that the Au nanoparticles improve the catalytic activity of the
developed electrodes towards the HER respect to the macroporous Ni
electrodes. EIS permits to obtain the electrochemically active area by
means of the roughness factor value. All the developed electrodes
show roughness factor values in the same order of magnitude. From
the activation energy results it can be concluded that the Au
nanoparticles improve the intrinsic catalytic activity of the
macroporous Ni electrodes.
Abstract: In Jordan having deficit atmospheric precipitation, an
increase in water demand occurs during summer months. Jordan can
be regarded with a relatively high potential for wastewater recycling
and reuse. The main purpose of this paper was to investigate the
removal of total suspended solids (TSS) and chemical oxygen
demand (COD) for olive mill wastewater (OMW) by
electrocoagulation (EC) process. In the combination of
electrocoagulation by using coupled iron–aluminum electrodes, the
optimum working pH was found to be around 6. Results indicated
that the electrocoagulation process allowed removal of TSS and COD
of about 82.5% and 47.5%, respectively at 45 mA/cm2 after 70
minutes by using coupled iron–aluminum electrodes. It was
demonstrated that the maximum TSS and COD removals were
obtained at some optimum experimental parameters for current
density, pH, and reaction time.
Abstract: Electroencephalogram (EEG) is a noninvasive
technique that registers signals originating from the firing of neurons
in the brain. The Emotiv EEG Neuroheadset is a consumer product
comprised of 14 EEG channels and was used to record the reactions
of the neurons within the brain to two forms of stimuli in 10
participants. These stimuli consisted of auditory and visual formats
that provided directions of ‘right’ or ‘left.’ Participants were
instructed to raise their right or left arm in accordance with the
instruction given. A scenario in OpenViBE was generated to both
stimulate the participants while recording their data. In OpenViBE,
the Graz Motor BCI Stimulator algorithm was configured to govern
the duration and number of visual stimuli. Utilizing EEGLAB under
the cross platform MATLAB®, the electrodes most stimulated during
the study were defined. Data outputs from EEGLAB were analyzed
using IBM SPSS Statistics® Version 20. This aided in determining
the electrodes to use in the development of a brain-machine interface
(BMI) using real-time EEG signals from the Emotiv EEG
Neuroheadset. Signal processing and feature extraction were
accomplished via the Simulink® signal processing toolbox. An
Arduino™ Duemilanove microcontroller was used to link the Emotiv
EEG Neuroheadset and the right and left Mecha TE™ Hands.
Abstract: This paper outlines the basic installation and operation of magnetic inductive flow velocity sensors on large underground cooling water pipelines. Research on the effects of cathodic protection as well as into other factors that might influence the overall performance of the meter is presented in this paper. The experiments were carried out on an immersion type magnetic meter specially used for flow measurement of cooling water pipeline. An attempt has been made in this paper to outline guidelines that can ensure accurate measurement related to immersion type magnetic meters on underground pipelines.
Abstract: In order to detect and quantify the phenolic contents
of a wastewater with biosensors, two working electrodes based on
modified Poly(Pyrrole) films were fabricated. Enzyme horseradish
peroxidase was used as biomolecule of the prepared electrodes.
Various phenolics were tested at the biosensor. Phenol detection was
realized by electrochemical reduction of quinones produced by
enzymatic activity. Analytical parameters were calculated and the
results were compared with each other.
Abstract: Newly synthesized Polypropylene-g-Polyethylene
glycol polymer was first time used for a compartment-less enzymatic
fuel cell. Working electrodes based on Polypropylene-g-Polyethylene
glycol were operated as unmediated and mediated system (with
ferrocene and gold/cobalt oxide nanoparticles). Glucose oxidase and
bilirubin oxidase was selected as anodic and cathodic enzyme,
respectively. Glucose was used as fuel in a single-compartment and
membrane-less cell. Maximum power density was obtained as 0.65
nW cm-2, 65 nW cm-2 and 23500 nW cm-2 from the unmediated,
ferrocene and gold/cobalt oxide modified polymeric film,
respectively. Power density was calculated to be ~16000 nW cm-2 for
undiluted wastewater sample with gold/cobalt oxide nanoparticles
including system.
Abstract: Elastomeric dielectric material has recently become a
new alternative for actuator technology. The characteristics of
dielectric elastomers placed between two electrodes to withstand
large strain when electrodes are charged has attracted the attention of
many researcher to study this material for actuator technology. Thus,
in the past few years Danfoss Ventures A/S has established their own
dielectric electro-active polymer (DEAP), which was called
PolyPower.
The main objective of this work was to investigate the dynamic
characteristics for vibration control of a PolyPower actuator folded in
‘pull’ configuration. A range of experiments was carried out on the
folded actuator including passive (without electrical load) and active
(with electrical load) testing. For both categories static and dynamic
testing have been done to determine the behavior of folded DEAP
actuator.
Voltage-Strain experiments show that the DEAP folded actuator is
a non-linear system. It is also shown that the voltage supplied has no
effect on the natural frequency. Finally, varying AC voltage with
different amplitude and frequency shows the parameters that
influence the performance of DEAP folded actuator. As a result, the
actuator performance dominated by the frequency dependence of the
elastic response and was less influenced by dielectric properties.
Abstract: The contact resistance between source/drain electrodes
and semiconductor layer is an important parameter affecting electron
transporting performance in the thin film transistor (TFT). In this
work, we introduced a transparent and the solution prossable
single-walled carbon nanotube (SWCNT)/Al-doped ZnO nano particle
(AZO NP) bilayer electrodes showing low contact resistance with
indium-oxide (In2O3) sol gel thin film. By inserting low work function
AZO NPs into the interface between the SWCNTs and the In2O3 which
has a high energy barrier, we could obtain an electrical Ohmic contact
between them. Finally, with the SWCNT-AZO NP bilayer electrodes,
we successfully fabricated a TFT showing a field effect mobility of
5.38 cm2/V·s at 250°C.
Abstract: In order to manufacture short gap single Si nanowire
(NW) field effect transistor (FET) by imprinting and transferring
method, we introduce the method using Al2O3 sacrificial layer. The
diameters of cylindrical Si NW addressed between Au electrodes by
dielectrophoretic (DEP) alignment method are controlled to 106, 128,
and 148 nm. After imprinting and transfer process, cylindrical Si NW
is embedded in PVP adhesive and dielectric layer. By curing
transferred cylindrical Si NW and Au electrodes on PVP-coated p++ Si
substrate with 200nm-thick SiO2, 3μm gap Si NW FET fabrication
was completed. As the diameter of embedded Si NW increases, the
mobility of FET increases from 80.51 to 121.24 cm2/V·s and the
threshold voltage moves from –7.17 to –2.44 V because the ratio of
surface to volume gets reduced.
Abstract: Carbon nanotube is one of the most attractive materials
for the potential applications of nanotechnology due to its excellent
mechanical, thermal, electrical and optical properties. In this paper we
report a supercapacitor made of nickel foil electrodes, coated with
multiwall carbon nanotubes (MWCNTs) thin film using
electrophoretic deposition (EPD) method. Chemical vapor deposition
method was used for the growth of MWCNTs and ethanol was used as
a hydrocarbon source. High graphitic multiwall carbon nanotube was
found at 750oC analyzing by Raman spectroscopy. We observed the
electrochemical performance of supercapacitor by cyclic
voltammetry. The electrodes of supercapacitor fabricated from
MWCNTs exhibit considerably small equivalent series resistance
(ESR), and a high specific power density. Electrophoretic deposition
is an easy method in fabricating MWCNT electrodes for high
performance supercapacitor.
Abstract: This paper contains 2 main parts. In the first part of paper we simulated and studied three types of electrode patterns used in various industries for suspension and handling of the semiconductor and glass and we selected the best pattern by evaluating the electrostatic force, which was comb pattern electrode.
In the second part we investigated the parameters affecting the amount of electrostatic force such as the gap between surface and electrode (g), the electrode width (w), the gap between electrodes (t), the surface permittivity and electrode length and methods of improvement of adhesion force by changing these values.
Abstract: This study models the use of transcutaneous electrical
nerve stimulation on skin with a disk electrode in order to simulate
tissue damage. The current density distribution above a disk electrode
is known to be a dynamic and non-uniform quantity that is intensified
at the edges of the disk. The non-uniformity is subject to change
through using various electrode geometries or stimulation methods.
One of these methods known as edge-retarded stimulation has shown
to reduce this edge enhancement. Though progress has been made in
modeling the behavior of a disk electrode, little has been done to test
the validity of these models in simulating the actual heat transfer
from the electrode. This simulation uses finite element software to
couple the injection of current from a disk electrode to heat transfer
described by the Pennesbioheat transfer equation. An example
application of this model is studying an experimental form of
stimulation, known as edge-retarded stimulation. The edge-retarded
stimulation method will reduce the current density at the edges of the
electrode. It is hypothesized that reducing the current density edge
enhancement effect will, in turn, reduce temperature change and
tissue damage at the edges of these electrodes. This study tests this
hypothesis as a demonstration of the capabilities of this model. The
edge-retarded stimulation proved to be safer after this simulation. It is
shown that temperature change and the fraction of tissue necrosis is
much greater in the square wave stimulation. These results bring
implications for changes of procedures in transcutaneous electrical
nerve stimulation and transcutaneous spinal cord stimulation as well.
Abstract: Assistive robotics are playing a vital role in advancing the quality of life for disable people. There exist wide range of systems that can control and guide autonomous mobile robots. The objective of the control system is to guide an autonomous mobile robot using the movement of eyes by means of EOG signal. The EOG signal is acquired using Ag/AgCl electrodes and this signal is processed by a microcontroller unit to calculate the eye gaze direction. Then according to the guidance control strategy, the control commands of the wheelchair are sent. The classification of different eye movements allows us to generate simple code for controlling the wheelchair. This work was aimed towards developing a usable and low-cost assistive robotic wheel chair system for disabled people. To live more independent life, the system can be used by the handicapped people especially those with only eye-motor coordination.
Abstract: We have developed a polyimide based neural interface electrode to record nerve signals from the sciatic nerve of a rat. The neural interface electrode has a split-ring shape, with four protruding gold electrodes for recording, and two reference gold electrodes around the split-ring. The split-ring electrode can be opened up to encircle the sciatic nerve. The four electrodes can be bent to sit on top of the nerve and hold the device in position, while the split-ring frame remains flat. In comparison, while traditional cuff electrodes can only fit certain sizes of the nerve, the developed device can fit a variety of rat sciatic nerve dimensions from 0.6 mm to 1.0 mm, and adapt to the chronic changes in the nerve as the electrode tips are bendable. The electrochemical impedance spectroscopy measurement was conducted. The gold electrode impedance is on the order of 10 kΩ, showing excellent charge injection capacity to record neural signals.