A DNA-Based Nanobiosensor for the Rapid Detection of the Dengue Virus in Mosquito

This paper describes the development of a DNA-based nanobiosensor to detect the dengue virus in mosquito using electrically active magnetic (EAM) nanoparticles as concentrator and electrochemical transducer. The biosensor detection encompasses two sets of oligonucleotide probes that are specific to the dengue virus: the detector probe labeled with the EAM nanoparticles and the biotinylated capture probe. The DNA targets are double hybridized to the detector and the capture probes and concentrated from nonspecific DNA fragments by applying a magnetic field. Subsequently, the DNA sandwiched targets (EAM-detector probe– DNA target–capture probe-biotin) are captured on streptavidin modified screen printed carbon electrodes through the biotinylated capture probes. Detection is achieved electrochemically by measuring the oxidation–reduction signal of the EAM nanoparticles. Results indicate that the biosensor is able to detect the redox signal of the EAM nanoparticles at dengue DNA concentrations as low as 10 ng/μl.




References:
[1] M. Guszman and G. Kouri. Dengue and dengue hemorrhagic fever in the
Americas: lessons and challenges. Journal of Clinical Virology. 2003.
27: 1-13.
[2] F. Pinheiro. Dengue in the Americas. 1980-1987. Epidemiol Bull
PAHO. 1989; 10:1-8.
[3] D.J. Gubler. Epidemic dengue/dengue hemorrhagic fever as a public
health, social and economic problem in the 21st century. Trends
Microbiol. 2002. 10: 100-3.
[4] R. Sithiprasasna, D. Strickman, B.L. Innis, K.J. Linthicum. ELISA for
detecting dengue and Japanese encephalitis viral antigen in mosquitoes.
Ann Trop Med Parasit. 1994. 88: 397-404.
[5] J. Compton. Nucleic acid sequence-based amplification. Nature. 1991.
350: 91-2.
[6] P.P. Samuel, B.K. Tyagi. Diagnostic methods for detection & isolation
of dengue viruses from vector mosquitoes. Indian J. Med. R. 2006.
123(5): 615-28.
[7] Zhu, N.N., Chang, Z., He, P.G., Fang, Y.Z. 2006. Electrochimica Acta.
51 (18), 3758–3762.
[8] Pal, S. and Alocilja, E.C., 2010. Electrically–active magnetic
nanoparticles as novel concentrator and electrochemical redox
transducer in Bacillus anthracis DNA detection. Biosensors and
Bioelectronics. 26(4), 1624-1630.
[9] Chow VT, Chan YC, Yong R, Lee KM, Lim LK, Chung YK, et al.
Monitoring of dengue viruses in field-caught Aedes aegypti and Aedes
albopictus mosquitoes by a type-specific polymerase chain reaction and
cycle sequencing. Am J Trop Med Hyg 1998; 58: 578–86.
[10] Fouque F, Garinci R,Gaborit P. Epidemiological and entomological
surveillance of the co-circulation of DENV-1, DENV-2 and DENV-4
viruses in Frech Guiana. Trop Med Int Health 2004; 9: 41–6.