Abstract: Chaiyaphum Starch Co. Ltd. is one of many starch
manufacturers that has introduced machinery to aid in manufacturing.
Even though machinery has replaced many elements and is now a
significant part in manufacturing processes, problems that must be
solved with respect to current process flow to increase efficiency still
exist. The paper-s aim is to increase productivity while maintaining
desired quality of starch, by redesigning the flipping machine-s
mechanical control system which has grossly low functional lifetime.
Such problems stem from the mechanical control system-s bearings,
as fluids and humidity can access into said bearing directly, in
tandem with vibrations from the machine-s function itself. The wheel
which is used to sense starch thickness occasionally falls from its
shaft, due to high speed rotation during operation, while the shaft
may bend from impact when processing dried bread. Redesigning its
mechanical control system has increased its efficiency, allowing
quality thickness measurement while increasing functional lifetime
an additional 62 days.
Abstract: COSMED K4b2 is a portable electrical device designed to test pulmonary functions. It is ideal for many applications that need the measurement of the cardio-respiratory response either in the field or in the lab is capable with the capability to delivery real time data to a sink node or a PC base station with storing data in the memory at the same time. But the actual sensor outputs and data received may contain some errors, such as impulsive noise which can be related to sensors, low batteries, environment or disturbance in data acquisition process. These abnormal outputs might cause misinterpretations of exercise or living activities to persons being monitored. In our paper we propose an effective and feasible method to detect and identify errors in applications by principal component analysis (PCA) and a back propagation (BP) neural network.
Abstract: Starting with an analysis of the financial and
operational indicators that can be found in the specialised literature,
this study aims to contribute to improvements in the performance
measurement systems used when the unit of analysis is the
manufacturing plant. For this a search was done in the highest impact
Journals of Production and Operations Management and
Management Accounting , with the aim of determining the financial
and operational indicators used to evaluate performance when
Advanced Production Practices have been implemented, more
specifically when the practices implemented are Total Quality
Management, JIT/Lean Manufacturing and Total Productive
Maintenance. This has enabled us to obtain a classification of the two
types of indicators based on how much each is used. For the financial
indicators we have also prepared a proposal that can be adapted to
manufacturing plants- accounting features. In the near future we will
propose a model that links practices implementation with financial
and operational indicators and these two last with each other. We aim
to will test this model empirically with the data obtained in the High
Performance Manufacturing Project.
Abstract: To model the human visual system (HVS) in the region of interest, we propose a new objective metric evaluation adapted to wavelet foveation-based image compression quality measurement, which exploits a foveation setup filter implementation technique in the DWT domain, based especially on the point and region of fixation of the human eye. This model is then used to predict the visible divergences between an original and compressed image with respect to this region field and yields an adapted and local measure error by removing all peripheral errors. The technique, which we call foveation wavelet visible difference prediction (FWVDP), is demonstrated on a number of noisy images all of which have the same local peak signal to noise ratio (PSNR), but visibly different errors. We show that the FWVDP reliably predicts the fixation areas of interest where error is masked, due to high image contrast, and the areas where the error is visible, due to low image contrast. The paper also suggests ways in which the FWVDP can be used to determine a visually optimal quantization strategy for foveation-based wavelet coefficients and to produce a quantitative local measure of image quality.
Abstract: The aim of this contribution is to present a new
approach in modeling the electrical activity of the human heart. A
recurrent artificial neural network is being used in order to exhibit a
subset of the dynamics of the electrical behavior of the human heart.
The proposed model can also be used, when integrated, as a
diagnostic tool of the human heart system.
What makes this approach unique is the fact that every model is
being developed from physiological measurements of an individual.
This kind of approach is very difficult to apply successfully in many
modeling problems, because of the complexity and entropy of the
free variables describing the complex system. Differences between
the modeled variables and the variables of an individual, measured at
specific moments, can be used for diagnostic purposes. The sensor
fusion used in order to optimize the utilization of biomedical sensors
is another point that this paper focuses on. Sensor fusion has been
known for its advantages in applications such as control and
diagnostics of mechanical and chemical processes.
Abstract: Photoplethysmography is a simple measurement of the
variation in blood volume in tissue. It detects the pulse signal of heart
beat as well as the low frequency signal of vasoconstriction and
vasodilation. The transmission type measurement is limited to only a
few specific positions for example the index finger that have a short
path length for light. The reflectance type measurement can be
conveniently applied on most parts of the body surface. This study
analyzed the factors that determine the quality of reflectance
photoplethysmograph signal including the emitter-detector distance,
wavelength, light intensity, and optical properties of skin tissue.
Light emitting diodes (LEDs) with four different visible
wavelengths were used as the light emitters. A phototransistor was
used as the light detector. A micro translation stage adjusts the
emitter-detector distance from 2 mm to 15 mm.
The reflective photoplethysmograph signals were measured on
different sites. The optimal emitter-detector distance was chosen to
have a large dynamic range for low frequency drifting without signal
saturation and a high perfusion index. Among these four wavelengths,
a yellowish green (571nm) light with a proper emitter-detection
distance of 2mm is the most suitable for obtaining a steady and reliable
reflectance photoplethysmograph signal
Abstract: Real-time measurement of applied forces, like tension, compression, torsion, and bending moment, identifies the transferred energies being applied to the bottomhole assembly (BHA). These forces are highly detrimental to measurement/logging-while-drilling tools and downhole equipment. Real-time measurement of the dynamic downhole behavior, including weight, torque, bending on bit, and vibration, establishes a real-time feedback loop between the downhole drilling system and drilling team at the surface. This paper describes the numerical analysis of the strain data acquired by the measurement tool at different locations on the strain pockets. The strain values obtained by FEA for various loading conditions (tension, compression, torque, and bending moment) are compared against experimental results obtained from an identical experimental setup. Numerical analyses results agree with experimental data within 8% and, therefore, substantiate and validate the FEA model. This FEA model can be used to analyze the combined loading conditions that reflect the actual drilling environment.
Abstract: The acoustic and articulatory properties of fricative speech sounds are being studied using magnetic resonance imaging (MRI) and acoustic recordings from a single subject. Area functions were derived from a complete set of axial and coronal MR slices using two different methods: the Mermelstein technique and the Blum transform. Area functions derived from the two techniques were shown to differ significantly in some cases. Such differences will lead to different acoustic predictions and it is important to know which is the more accurate. The vocal tract acoustic transfer function (VTTF) was derived from these area functions for each fricative and compared with measured speech signals for the same fricative and same subject. The VTTFs for /f/ in two vowel contexts and the corresponding acoustic spectra are derived here; the Blum transform appears to show a better match between prediction and measurement than the Mermelstein technique.
Abstract: The electrochemical coagulation of a kaolin
suspension was investigated at the currents of 0.06, 0.12, 0.22, 0.44,
0.85 A (corresponding to 0.68, 1.36, 2.50, 5.00, 9.66 mA·cm-2,
respectively) for the contact time of 5, 10, 20, 30, and 50 min. The
TSS removal efficiency at currents of 0.06 A, 0.12 A and 0.22 A
increased with the amount of iron generated by the sacrificial anode,
while the removal efficiencies did not increase proportionally with
the amount of iron generated at the currents of 0.44 and 0.85 A,
where electroflotation was clearly observed. Zeta potential
measurement illustrated the presence of the highly positive charged
particles created by sorption of highly charged polymeric metal
hydroxyl species onto the negative surface charged kaolin particles at
both low and high applied currents. The disappearance of the
individual peaks after certain contact times indicated the attraction
between these positive and negative charged particles causing
agglomeration. It was concluded that charge neutralization of the
individual species was not the only mechanism operating in the
electrocoagulation process at any current level, but electrostatic
attraction was likely to co-operate or mainly operate.
Abstract: The common practice of operating S-rotor is in an
open environment; however there are times when the rotor is
installed in a bounded environment and there might be changes in the
performance of the rotor. This paper presents the changes in the
performance of S-rotor when operated in bounded flows. The
investigation was conducted experimentally to compare the
performance of the rotors in bounded environment against open
environment. Three different rotors models were designed, fabricated
and subjected to experimental measurements. All of the three models
were having 600 mm height and 300 mm Diameter. They were tested
in three different flow environments; namely: partially bounded
environment, fully bounded environment and open environment.
Rotors were found to have better starting up capabilities when
operated in bounded environment. Apart from that, all rotors manage
to achieve higher Power and Torque Coefficients at a higher Tip
Speed Ratio as compared to the open environment.
Abstract: One of the main issues in Computer Vision is to extract the movement of one or several points or objects of interest in an image or video sequence to conduct any kind of study or control process. Different techniques to solve this problem have been applied in numerous areas such as surveillance systems, analysis of traffic, motion capture, image compression, navigation systems and others, where the specific characteristics of each scenario determine the approximation to the problem. This paper puts forward a Computer Vision based algorithm to analyze fish trajectories in high turbulence conditions in artificial structures called vertical slot fishways, designed to allow the upstream migration of fish through obstructions in rivers. The suggested algorithm calculates the position of the fish at every instant starting from images recorded with a camera and using neural networks to execute fish detection on images. Different laboratory tests have been carried out in a full scale fishway model and with living fishes, allowing the reconstruction of the fish trajectory and the measurement of velocities and accelerations of the fish. These data can provide useful information to design more effective vertical slot fishways.
Abstract: The work presents a development of EN338 strength classes for Strombosia pustulata, Pterygotama crocarpa, Nauclea diderrichii and Entandrophragma cyclindricum Nigerian timber species. The specimens for experimental measurements were obtained from the timber-shed at the famous Panteka market in Kaduna in the northern part of Nigeria. Laboratory experiments were conducted to determine the physical and mechanical properties of the selected timber species in accordance with EN 13183-1 and ASTM D193. The mechanical properties were determined using three point bending test. The generated properties were used to obtain the characteristic values of the material properties in accordance with EN384. The selected timber species were then classified according to EN 338. Strombosia pustulata, Pterygotama crocarpa, Nauclea diderrichii and Entandrophragma cyclindricum were assigned to strength classes D40, C14, D40 and D24 respectively. Other properties such as tensile and compressive strengths parallel and perpendicular to grains, shear strength as well as shear modulus were obtained in accordance with EN 338.
Abstract: A measurement apparatus is designed and fabricated to
measure the effective thermal conductivity (keff) of a VIP (vacuum
insulation panel) core specimen under various vacuum states and
external loads. The apparatus consists of part for measuring keff, and
parts for controlling external load and vacuum condition. Uncertainty
of the apparatus is validated by measuring the standard reference
material and comparing with commercial devices with VIP samples.
Assessed uncertainty is maximum 2.5 % in case of the standard
reference material, 10 % in case of VIP samples. Using the apparatus,
keff of glass paper under various vacuum levels is examined.
Abstract: The purpose of this paper is to discuss the influence of
resistance characteristic on the high conductive concrete considering
the various voltage and environment. The four-electrode method is
applied to the tailor-made high conductive concrete with appropriate
proportion. The curve of resistivity with the changes of voltage and
environment is plotted and the changes of resistivity are explored. The
result based on the methods reveals that resistivity is less affected by
the temperature factor, and the four-electrode method would be an
applicable measurement method on a site inspection.
Abstract: In order to provide accurate heart rate variability
indices of sympathetic and parasympathetic activity, the low
frequency and high frequency components of an RR heart rate signal
must be adequately separated. This is not always possible by just
applying spectral analysis, as power from the high and low frequency
components often leak into their adjacent bands. Furthermore,
without the respiratory spectra it is not obvious that the low
frequency component is not another respiratory component, which
can appear in the lower band. This paper describes an adaptive filter,
which aids the separation of the low frequency sympathetic and high
frequency parasympathetic components from an ECG R-R interval
signal, enabling the attainment of more accurate heart rate variability
measures. The algorithm is applied to simulated signals and heart rate
and respiratory signals acquired from an ambulatory monitor
incorporating single lead ECG and inductive plethysmography
sensors embedded in a garment. The results show an improvement
over standard heart rate variability spectral measurements.
Abstract: Efficient and safe plant operation can only be
achieved if the operators are able to monitor all key process
parameters. Instrumentation is used to measure many process
variables, like temperatures, pressures, flow rates, compositions or
other product properties. Therefore Performance monitoring is a
suitable tool for operators. In this paper, we integrate rigorous
simulation model, data reconciliation and parameter estimation to
monitor process equipments and determine key performance
indicator (KPI) of them. The applied method here has been
implemented in two case studies.
Abstract: Near-infrared (NIR) spectroscopy is a widely used
method for material identification for laboratory and industrial applications.
While standard spectrometers only allow measurements at
one sampling point at a time, NIR Spectral Imaging techniques can
measure, in real-time, both the size and shape of an object as well as
identify the material the object is made of. The online classification
and sorting of recovered paper with NIR Spectral Imaging (SI)
is used with success in the paper recycling industry throughout
Europe. Recently, the globalisation of the recycling material streams
caused that water-based flexographic-printed newspapers mainly from
UK and Italy appear also in central Europe. These flexo-printed
newspapers are not sufficiently de-inkable with the standard de-inking
process originally developed for offset-printed paper. This de-inking
process removes the ink from recovered paper and is the fundamental
processing step to produce high-quality paper from recovered paper.
Thus, the flexo-printed newspapers are a growing problem for the
recycling industry as they reduce the quality of the produced paper
if their amount exceeds a certain limit within the recovered paper
material.
This paper presents the results of a research project for the
development of an automated entry inspection system for recovered
paper that was jointly conducted by CTR AG (Austria) and PTS
Papiertechnische Stiftung (Germany). Within the project an NIR
SI prototype for the identification of flexo-printed newspaper has
been developed. The prototype can identify and sort out flexoprinted
newspapers in real-time and achieves a detection accuracy
for flexo-printed newspaper of over 95%. NIR SI, the technology the
prototype is based on, allows the development of inspection systems
for incoming goods in a paper production facility as well as industrial
sorting systems for recovered paper in the recycling industry in the
near future.
Abstract: To investigate the applicability of the EDR-2 film for
clinical radiation dosimetry, percentage depth-doses, profiles and
distributions in open and dynamically wedged fields were measured
using film and compared with data from a Treatment Planning
system.The validity of the EDR2 film to measure dose in a plane
parallel to the beam was tested by irradiating 10 cm×10 cm and 4
cm×4 cm fields from a Siemens, primus linac with a 6MV beam and
a source-to-surface distance of 100 cm. The film was placed
Horizontally between solid water phantom blocks and marked
with pin holes at a depth of 10 cm from the incident beam surface.
The film measurement results, in absolute dose, were compared with
ion chamber measurements using a Welhoffer scanning water tank
system and Treatment Planning system. Our results indicate a
maximum underestimate of calculated dose of 8 % with Treatment
Planning system.
Abstract: Process measurement is the task of empirically and objectively assigning numbers to the properties of business processes in such a way as to describe them. Desirable attributes to study and measure include complexity, cost, maintainability, and reliability. In our work we will focus on investigating process complexity. We define process complexity as the degree to which a business process is difficult to analyze, understand or explain. One way to analyze a process- complexity is to use a process control-flow complexity measure. In this paper, an attempt has been made to evaluate the control-flow complexity measure in terms of Weyuker-s properties. Weyuker-s properties must be satisfied by any complexity measure to qualify as a good and comprehensive one.
Abstract: With the increasing spread of computers and the internet among culturally, linguistically and geographically diverse communities, issues of internationalization and localization and becoming increasingly important. For some of the issues such as different scales for length and temperature, there is a well-developed measurement theory. For others such as date formats no such theory will be possible. This paper fills a gap by developing a measurement theory for a class of scales previously overlooked, based on discrete and interval-valued scales such as spanner and shoe sizes. The paper gives a theoretical foundation for a class of data representation problems.