Abstract: The evaluation of the convective heat transfer of flow in passages with rectangular cross section is still of interest for the heat transfer investigators, as in the air heater solar collectors. The aim of this paper is to present investigation results on the natural convection heat transfer in a solar air heater. The effect of the channel length as heat transfer surface and the inclination of the passage were investigated. The results were obtained experimentally and theoretically. For that, an experimental test rig was fabricated with channel lengths of 1m, 1.5m, and 2m. For each length, the air outlet and inlet temperatures, absorber and cover temperatures, solar radiation intensity and air flow rate were measured at 10o, 30o, 50o, 70o, and 90o tilt angles. Measurements were recorded every 2 hours interval to investigate the transient behavior of the system. The experimental and theoretical results are presented in terms of Nu number versus Ra number and discussed. The percentages of differences between experimental and theoretical results are within the margin of 6% to 13%, effectively. It is recommended to extend the investigation to study the same configurations with different artificial surface roughing by ribs or pins.
Abstract: The common practice of operating S-rotor is in an
open environment; however there are times when the rotor is
installed in a bounded environment and there might be changes in the
performance of the rotor. This paper presents the changes in the
performance of S-rotor when operated in bounded flows. The
investigation was conducted experimentally to compare the
performance of the rotors in bounded environment against open
environment. Three different rotors models were designed, fabricated
and subjected to experimental measurements. All of the three models
were having 600 mm height and 300 mm Diameter. They were tested
in three different flow environments; namely: partially bounded
environment, fully bounded environment and open environment.
Rotors were found to have better starting up capabilities when
operated in bounded environment. Apart from that, all rotors manage
to achieve higher Power and Torque Coefficients at a higher Tip
Speed Ratio as compared to the open environment.