Abstract: This article simulates the wind generator set which has
two fault bearing collar rail destruction and the gear box oil leak fault.
The electric current signal which produced by the generator, We use
Empirical Mode Decomposition (EMD) as well as Fast Fourier
Transform (FFT) obtains the frequency range-s signal figure and
characteristic value. The last step is use a kind of Artificial Neural
Network (ANN) classifies which determination fault signal's type and
reason. The ANN purpose of the automatic identification wind
generator set fault..
Abstract: This paper proposes the method combining artificial neural network with particle swarm optimization (PSO) to implement the maximum power point tracking (MPPT) by controlling the rotor speed of the wind generator. With the measurements of wind speed, rotor speed of wind generator and output power, the artificial neural network can be trained and the wind speed can be estimated. The proposed control system in this paper provides a manner for searching the maximum output power of wind generator even under the conditions of varying wind speed and load impedance.
Abstract: This paper describes a method of signal process applied
on an end effects of Hilbert-Huang transform (HHT) to provide an
improvement in the reality of spectrum. The method is based on
back-propagation network (BPN). To improve the effect, the end
extension of the original signal is obtained by back-propagation
network. A full waveform including origin and its extension is
decomposed by using empirical mode decomposition (EMD) to obtain
intrinsic mode functions (IMFs) of the waveform. Then, the Hilbert
transform (HT) is applied to the IMFs to obtain the Hilbert spectrum of
the waveform. As a result, the method is superiority of the processing
of end effect of HHT to obtain the real frequency spectrum of signals.
Abstract: The purpose of this paper is to discuss the influence of
resistance characteristic on the high conductive concrete considering
the various voltage and environment. The four-electrode method is
applied to the tailor-made high conductive concrete with appropriate
proportion. The curve of resistivity with the changes of voltage and
environment is plotted and the changes of resistivity are explored. The
result based on the methods reveals that resistivity is less affected by
the temperature factor, and the four-electrode method would be an
applicable measurement method on a site inspection.
Abstract: This study reports the preparation of soft magnetic
ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213
mm and, with a thickness of approximately 22 μm ± 2 μm. The microstructure and magnetic properties of the ribbons were
characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material
properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic
measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide
ribbon, the magnetic responses are not uniformly distributed. To
understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a
ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.
Abstract: This paper proposes the method combining artificial
neural network (ANN) with particle swarm optimization (PSO) to
implement the maximum power point tracking (MPPT) by controlling
the rotor speed of the wind generator. First, the measurements of wind
speed, rotor speed of wind power generator and output power of wind
power generator are applied to train artificial neural network and to
estimate the wind speed. Second, the method mentioned above is
applied to estimate and control the optimal rotor speed of the wind
turbine so as to output the maximum power. Finally, the result reveals
that the control system discussed in this paper extracts the maximum
output power of wind generator within the short duration even in the
conditions of wind speed and load impedance variation.
Abstract: This paper presents a signal analysis process for
improving energy completeness based on the Hilbert-Huang
Transform (HHT). Firstly, the vibration signal of a DC Motor obtained
by employing an accelerometer is the model used to analyze the
signal. Secondly, the intrinsic mode functions (IMFs) and Hilbert
spectrum of the decomposed signal are obtained by applying HHT.
The results of the IMFs constituent and the original signal are
compared and the process of energy loss is discussed. Finally, the
differences between Wavelet Transform (WT) and HHT in analyzing
the signal are compared. The simulated results reveal the analysis
process based on HHT is advantageous for the enhancement of energy
completeness.
Abstract: This paper aims to discuss the influence of resistance
characteristic on the high conductive concrete considering the changes
of voltage and environment. The high conductive concrete with
appropriate proportion is produced to the press-electrode method. The
curve of resistivity with the changes of voltage and environment is
plotted and the changes of resistivity are explored.
Abstract: The purpose of this paper is to improve electromagnetic characteristics on grounding grid by applying the conductive concrete. The conductive concrete in this study is under an extra high voltage (EHV, 345kV) system located in a high-tech industrial park or science park. Instead of surrounding soil of grounding grid, the application of conductive concrete can reduce equipment damage and body damage caused by switching surges. The focus of the two cases on the EHV distribution system in a high-tech industrial park is presented to analyze four soil material styles. By comparing several soil material styles, the study results have shown that the conductive concrete can effectively reduce the negative damages caused by electromagnetic transient. The adoption of the style of grounding grid located 1.0 (m) underground and conductive concrete located from the ground surface to 1.25 (m) underground can obviously improve the electromagnetic characteristics so as to advance protective efficiency.
Abstract: This paper presents an application of particle swarm
optimization (PSO) to the grounding grid planning which compares to
the application of genetic algorithm (GA). Firstly, based on IEEE
Std.80, the cost function of the grounding grid and the constraints of
ground potential rise, step voltage and touch voltage are constructed
for formulating the optimization problem of grounding grid planning.
Secondly, GA and PSO algorithms for obtaining optimal solution of
grounding grid are developed. Finally, a case of grounding grid
planning is shown the superiority and availability of the PSO
algorithm and proposal planning results of grounding grid in cost and
computational time.
Abstract: This study reports the preparation of soft magnetic ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213 mm and, with a thickness of approximately 22 μm 2 μm. The microstructure and magnetic properties of the ribbons were characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide ribbon, the magnetic responses are not uniformly distributed. To understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.