Abstract: One of the main challenges in using the Discrete
Element Method (DEM) is to specify the correct input parameter
values. In general, the models are sensitive to the input parameter
values and accurate results can only be achieved if the correct values
are specified. For the linear contact model, micro-parameters such as
the particle density, stiffness, coefficient of friction, as well as the
particle size and shape distributions are required. There is a need for
a procedure to accurately calibrate these parameters before any
attempt can be made to accurately model a complete bulk materials
handling system. Since DEM is often used to model applications in
the mining and quarrying industries, a calibration procedure was
developed for materials that consist of relatively large (up to 40 mm
in size) particles. A coarse crushed aggregate was used as the test
material. Using a specially designed large shear box with a diameter
of 590 mm, the confined Young’s modulus (bulk stiffness) and
internal friction angle of the material were measured by means of the
confined compression test and the direct shear test respectively. DEM
models of the experimental setup were developed and the input
parameter values were varied iteratively until a close correlation
between the experimental and numerical results was achieved. The
calibration process was validated by modelling the pull-out of an
anchor from a bed of material. The model results compared well with
experimental measurement.
Abstract: The Scheduling and mapping of tasks on a set of
processors is considered as a critical problem in parallel and
distributed computing system. This paper deals with the problem of
dynamic scheduling on a special type of multiprocessor architecture
known as Linear Crossed Cube (LCQ) network. This proposed
multiprocessor is a hybrid network which combines the features of
both linear types of architectures as well as cube based architectures.
Two standard dynamic scheduling schemes namely Minimum
Distance Scheduling (MDS) and Two Round Scheduling (TRS)
schemes are implemented on the LCQ network. Parallel tasks are
mapped and the imbalance of load is evaluated on different set of
processors in LCQ network. The simulations results are evaluated
and effort is made by means of through analysis of the results to
obtain the best solution for the given network in term of load
imbalance left and execution time. The other performance matrices
like speedup and efficiency are also evaluated with the given
dynamic algorithms.
Abstract: ABC classification is widely used by managers for
inventory control. The classical ABC classification is based on Pareto
principle and according to the criterion of the annual use value only.
Single criterion classification is often insufficient for a closely
inventory control. Multi-criteria inventory classification models have
been proposed by researchers in order to consider other important
criteria. From these models, we will consider a specific model in
order to make a sensitive analysis on the composite score calculated
for each item. In fact, this score, based on a normalized average
between a good and a bad optimized index, can affect the ABC-item
classification. We will focus on items differently assigned to classes
and then propose a classification compromise.
Abstract: Rainfall runoff models play important role in
hydrological predictions. However, the model is only one part of the
process for creation of flood prediction. The aim of this paper is to
show the process of successful prediction for flood event (May 15 –
May 18 2014). Prediction was performed by rainfall runoff model
HEC–HMS, one of the models computed within Floreon+ system.
The paper briefly evaluates the results of automatic hydrologic
prediction on the river Olše catchment and its gages Český Těšín and
Věřňovice.
Abstract: Transmission system performance analysis is vital to
proper planning and operations of power systems in the presence of
deregulation. Key performance indicators (KPIs) are often used as
measure of degree of performance. This paper gives a novel method
to determine the transmission efficiency by evaluating the ratio of
real power losses incurred from a specified transfer direction.
Available Transmission Transfer Efficiency (ATTE) expresses the
percentage of real power received resulting from inter-area available
power transfer. The Tie line (Rated system path) performance is seen
to differ from system wide (Network response) performance and
ATTE values obtained are transfer direction specific. The required
sending end quantities with specified receiving end ATC and the
receiving end power circle diagram are obtained for the tie line
analysis. The amount of real power loss load relative to the available
transfer capability gives a measure of the transmission grid
efficiency.
Abstract: The Aptima® HIV-1 Quant Dx Assay is a fully
automated assay on the Panther system. It is based on Transcription-
Mediated Amplification and real time detection technologies. This
assay is intended for monitoring HIV-1 viral load in plasma
specimens and for the detection of HIV-1 in plasma and serum
specimens.
Nine-hundred and seventy nine specimens selected at random
from routine testing at St Thomas’ Hospital, London were
anonymised and used to compare the performance of the Aptima
HIV-1 Quant Dx assay and Roche COBAS® AmpliPrep/COBAS®
TaqMan® HIV-1 Test, v2.0. Two-hundred and thirty four specimens
gave quantitative HIV-1 viral load results in both assays. The
quantitative results reported by the Aptima Assay were comparable to
those reported by the Roche COBAS AmpliPrep/COBAS TaqMan
HIV-1 Test, v2.0 with a linear regression slope of 1.04 and an
intercept on -0.097.
The Aptima assay detected HIV-1 in more samples than the
COBAS assay. This was not due to lack of specificity of the Aptima
assay because this assay gave 99.83% specificity on testing plasma
specimens from 600 HIV-1 negative individuals. To understand the
reason for this higher detection rate a side-by-side comparison of low
level panels made from the HIV-1 3rd international standard
(NIBSC10/152) and clinical samples of various subtypes were tested
in both assays. The Aptima assay was more sensitive than the
COBAS assay.
The good sensitivity, specificity and agreement with other
commercial assays make the HIV-1 Quant Dx Assay appropriate for
both viral load monitoring and detection of HIV-1 infections.
Abstract: In this paper static scheme of under-frequency based load shedding is considered for chemical and petrochemical industries with islanded distribution networks relying heavily on the primary commodity to ensure minimum production loss, plant downtime or critical equipment shutdown. A simplistic methodology is proposed for in-house implementation of this scheme using underfrequency relays and a step by step guide is provided including the techniques to calculate maximum percentage overloads, frequency decay rates, time based frequency response and frequency based time response of the system. Case study of FFL electrical system is utilized, presenting the actual system parameters and employed load shedding settings following the similar series of steps. The arbitrary settings are then verified for worst overload conditions (loss of a generation source in this case) and comprehensive system response is then investigated.
Abstract: The article deals with the tool in Matlab GUI form
that is designed to analyse a mechatronic system sensitivity and
tolerance. In the analysed mechatronic system, a torque is transferred
from the drive to the load through a coupling containing flexible
elements. Different methods of control system design are used. The
classic form of the feedback control is proposed using Naslin method,
modulus optimum criterion and inverse dynamics method. The
cascade form of the control is proposed based on combination of
modulus optimum criterion and symmetric optimum criterion. The
sensitivity is analysed on the basis of absolute and relative sensitivity
of system function to the change of chosen parameter value of the
mechatronic system, as well as the control subsystem. The tolerance
is analysed in the form of determining the range of allowed relative
changes of selected system parameters in the field of system stability.
The tool allows to analyse an influence of torsion stiffness, torsion
damping, inertia moments of the motor and the load and controller(s)
parameters. The sensitivity and tolerance are monitored in terms of
the impact of parameter change on the response in the form of system
step response and system frequency-response logarithmic
characteristics. The Symbolic Math Toolbox for expression of the
final shape of analysed system functions was used. The sensitivity
and tolerance are graphically represented as 2D graph of sensitivity
or tolerance of the system function and 3D/2D static/interactive graph
of step/frequency response.
Abstract: A numerical model has been developed to investigate the thermally triggered release kinetics for drug delivery using phase change material as shell of microcapsules. Biocompatible material n-Eicosane is used as demonstration. PCM shell of microcapsule will remain in solid form after the drug is taken, so the drug will be encapsulated by the shell, and will not be released until the target body part of lesion is exposed to external heat source, which will thermally trigger the release kinetics, leading to solid-to-liquid phase change. The findings can lead to better understanding on the key effects influencing the phase change process for drug delivery applications. The facile approach to release drug from core/shell structure of microcapsule can be well integrated with organic solvent free fabrication of microcapsules, using double emulsion as template in microfluidic aqueous two phase system.
Abstract: This paper presents dynamic models of distributed
generators (DG) and investigates dynamic behavior of the DG units
in the micro grid system. The DG units include photovoltaic and fuel
cell sources. The voltage source inverter is adopted since the
electronic interface which can be equipped with its controller to keep
stability of the micro grid during small signal dynamics. This paper
also introduces power management strategies and implements the DG
load sharing concept to keep the micro grid operation in gridconnected
and islanding modes of operation. The results demonstrate
the operation and performance of the photovoltaic and fuel cell as
distributed generators in a micro grid. The entire control system in
the micro grid is developed by combining the benefits of the power
control and the voltage control strategies. Simulation results are all
reported, confirming the validity of the proposed control technique.
Abstract: The paper is focused on the identification of limiting
environmental factors of individual industrial floors on which newly
developed polymer protection and repair systems with the use of
secondary raw materials will be used. These mainly include floors
with extreme stresses and special requirements for materials used. In
relation to the environment of a particular industrial floor, it is
necessary to ensure, for example, chemical stability, resistance to
higher temperatures, resistance to higher mechanical stress, etc. for
developed materials, which is reflected in the demands for the
developed material systems. The paper describes individual
environments and, in relation to them, also requirements for
individual components of the developed materials and for the
developed materials as a whole.
Abstract: Testability modeling is a commonly used method in
testability design and analysis of system. A dependency matrix will be
obtained from testability modeling, and we will give a quantitative
evaluation about fault detection and isolation.
Based on the dependency matrix, we can obtain the diagnosis tree.
The tree provides the procedures of the fault detection and isolation.
But the dependency matrix usually includes built-in test (BIT) and
manual test in fact. BIT runs the test automatically and is not limited
by the procedures. The method above cannot give a more efficient
diagnosis and use the advantages of the BIT.
A Comprehensive method of fault detection and isolation is
proposed. This method combines the advantages of the BIT and
Manual test by splitting the matrix. The result of the case study shows
that the method is effective.
Abstract: The quality and condition of perishable products
delivered to the market and their subsequent selling prices are
directly affected by the care taken during harvesting and handling.
Mechanical injury, in fact, occurs at all stages, from pre-harvest
operations through post-harvest handling, packing and transport to
the market. The main implications of this damage are the reduction of
the product’s quality and economical losses related to the shelf life
diminution. For most perishable products, the shelf life is relatively
short and it is typically dictated by microbial growth related to the
application of dynamic and static loads during transportation. This
paper presents the correlation between vibration levels and
microbiological growth on strawberries and woodland strawberries
and detects the presence of volatile organic compounds (VOC) in
order to develop an intelligent logistic unit capable of monitoring
VOCs using a specific sensor system. Fresh fruits were exposed to
vibrations by means of a vibrating table in a temperature-controlled
environment. Microbiological analyses were conducted on samples,
taken at different positions along the column of the crates. The values
obtained were compared with control samples not exposed to
vibrations and the results show that different positions along the
column influence the development of bacteria, yeasts and filamentous
fungi.
Abstract: This paper presents a novel integrated hybrid
approach for fault diagnosis (FD) of nonlinear systems. Unlike most
FD techniques, the proposed solution simultaneously accomplishes
fault detection, isolation, and identification (FDII) within a unified
diagnostic module. At the core of this solution is a bank of adaptive
neural parameter estimators (NPE) associated with a set of singleparameter
fault models. The NPEs continuously estimate unknown
fault parameters (FP) that are indicators of faults in the system. Two
NPE structures including series-parallel and parallel are developed
with their exclusive set of desirable attributes. The parallel scheme is
extremely robust to measurement noise and possesses a simpler, yet
more solid, fault isolation logic. On the contrary, the series-parallel
scheme displays short FD delays and is robust to closed-loop system
transients due to changes in control commands. Finally, a fault
tolerant observer (FTO) is designed to extend the capability of the
NPEs to systems with partial-state measurement.
Abstract: The aim of this paper is to present the optimization
methodology developed in the frame of a Coastal Transport
Information System. The system will be used for the effective design
of coastal transportation lines and incorporates subsystems that
implement models, tools and techniques that may support the design
of improved networks. The role of the optimization and decision
subsystem is to provide the user with better and optimal scenarios
that will best fulfill any constrains, goals or requirements posed. The
complexity of the problem and the large number of parameters and
objectives involved led to the adoption of an evolutionary method
(Genetic Algorithms). The problem model and the subsystem
structure are presented in detail, and, its support for simulation is also
discussed.
Abstract: Flexible AC Transmission Systems (FACTS) is
granting a new group of advanced power electronic devices emerging
for enhancement of the power system performance. Unified Power
Flow Controller (UPFC) is a recent version of FACTS devices for
power system applications. The back-up energy supply system
incorporated with UPFC is providing a complete control of real and
reactive power at the same time and hence is competent to improve
the performance of an electrical power system. In this article, backup
energy supply unit such as superconducting magnetic energy storage
(SMES) is integrated with UPFC. In addition, comparative
exploration of UPFC–battery, UPFC–UC and UPFC–SMES
performance is evaluated through the vibrant simulation by using
MATLAB/Simulink software.
Abstract: After the internet explosion in the 90’s, technology
was immediately integrated into the school system. Technology
which symbolizes advancement in human knowledge was seen as a
setback by many educators. Efforts have been made to help stem this
erroneous believes and help educators realize the benefits of
technology and ways of implementing it in the classrooms especially
in the sciences. This advancement created a constantly expanding gap
between the pupil’s perception on the use of technology within the
learning atmosphere and the teacher’s perception and limitations
hence, the focus of this paper is on the need to refocus on the use of
Science and Technology in enhancing children’s potentials in
learning at school especially in Science for sustainable development
in Nigeria. The paper recommended measures for facilitating the
sustenance of science and technology in Nigerian schools so as to
enhance the potentials of our children in Science and Technology for
a better tomorrow.
Abstract: The design philosophy of building structure has been
changing time to time. The reason for this is because of an increase of
human inertest, an improved building materials and technology that
will impact how we live, to speed up construction period and natural
effect which includes earthquake disasters and environmental effect.
One technique which takes in to account the above case is using a
prefabricable structural system. In which each and every structural
element is designed and prefabricated and assembled on a site so that
the construction speed is increased and the environmental impact is
also enhanced. This system has an immense advantage such as: reduce
construction cost, reusable, recyclable, speed up construction period
and less environmental effect. In this study, it is tried to present some
of the developed and evaluated structural elements of building
structures.
Abstract: This paper describes the issues relating to the role of
the flash flood early warning system provided by the Malaysian
Government to the communities in Malaysia, specifically during the
flash flood disaster in the Cameron Highlands, Malaysia. Normally,
flash flood disasters can occur as a result of heavy rainfall in an area,
and that water may possibly cause flooding via streams or narrow
channels. The focus of this study is the flash flood disaster which
occurred on 23 October 2013 in the Cameron Highlands, and as a
result the Sungai Bertam overflowed after the release of water from
the Sultan Abu Bakar Dam. This release of water from the dam
caused flash flooding which led to damage to properties and also the
death of residents and livestock in the area. Therefore, the effort of
this study is to identify the perceptions of the flash flood victims on
the role of the flash flood early warning system. For the purposes of
this study, data were gathered through face-to-face interviews from
those flood victims who were willing to participate in this study. This
approach helped the researcher to glean in-depth information about
their feelings and perceptions of the role of the flash flood early
warning system offered by the government. The data were analysed
descriptively and the findings show that the respondents of 22 flood
victims believe strongly that the flash flood early warning system was
confusing and dysfunctional, and communities had failed to response
positively to it. Therefore, most of the communities were not well
prepared for the releasing of water from the dam which caused
property damage, and 3 people were killed in the Cameron Highland
flash flood disaster.
Abstract: In this study, polycaprolactone (PCL) was dissolved
in chloroform:ethanol solvent system at a concentration of 18 w/v %.
1, 2, 4, and 6 droplets of formic acid were added to the prepared 10ml
PCL-chloroform:ethanol solutions separately. Fibrous webs were
produced by electrospinning technique based on the horizontal
working principle. Morphology of the webs was investigated by
using scanning electron microscopy (SEM) whereas fiber diameters
were measured by Image J Software System. The effect of formic
acid addition to the mostly used chloroform solvent on fiber
morphology was examined.
Results indicate that there is a distinct fall in fiber diameter with
the addition of formic acid drops. The average fiber diameter was
measured as 2.22μm in PCL /chloroform:ethanol solution system. On
the other hand, 328nm and 256 nm average fiber diameters were
measured for the samples of 4 drops and 6 drops formic acid added.
This study offers alternative solvent systems to produce nanoscaled,
nontoxic PCL fibrous webs by electrospinning technique.