Abstract: Applying corona wind as a novel technique can lead
to a great level of heat and mass transfer augmentation by using very
small amount of energy. Enhancement of forced flow evaporation
rate by applying electric field (corona wind) has been experimentally
evaluated in this study. Corona wind produced by a fine wire
electrode which is charged with positive high DC voltage impinges
to water surface and leads to evaporation enhancement by disturbing
the saturated air layer over water surface. The study was focused on
the effect of corona wind velocity, electrode spacing and air flow
velocity on the level of evaporation enhancement. Two sets of
experiments, i.e. with and without electric field, have been
conducted. Data obtained from the first experiment were used as
reference for evaluation of evaporation enhancement at the presence
of electric field. Applied voltages ranged from corona threshold
voltage to spark over voltage at 1 kV increments. The results showed
that corona wind has great enhancement effect on water evaporation
rate, but its effectiveness gradually diminishes by increasing air flow
velocity. Maximum enhancements were 7.3 and 3.6 for air velocities
of 0.125 and 1.75 m/s, respectively.
Abstract: This study investigates a voltage-controllable liquid crystals lens with a Fresnel zone electrode. When applying a proper voltage on the liquid crystal cell, a Fresnel-zone-distributed electric field is induced to direct liquid crystals aligned in a concentric structure. Owing to the concentrically aligned liquid crystals, a Fresnel lens is formed. We probe the Fresnel liquid crystal lens using a polarized incident beam with a wavelength of 632.8 nm, finding that the diffraction efficiency depends on the applying voltage. A remarkable diffraction efficiency of ~39.5 % is measured at the voltage of 0.9V. Additionally, a dual focus lens is fabricated by attaching a plane-convex lens to the Fresnel liquid crystals cell. The Fresnel LC lens and the dual focus lens may be applied for DVD/CD pick-up head, confocal microscopy system, or electrically-controlling optical systems.
Abstract: In this paper the performance of unified power flow
controller is investigated in controlling the flow of po wer over the
transmission line. Voltage sources model is utilized to study the
behaviour of the UPFC in regulating the active, reactive power and
voltage profile. This model is incorporated in Newton Raphson
algorithm for load flow studies. Simultaneous method is employed
in which equations of UPFC and the power balance equations of
network are combined in to one set of non-linear algebraic equations.
It is solved according to the Newton raphson algorithm. Case studies
are carried on standard 5 bus network. Simulation is done in Matlab.
The result of network with and without using UPFC are compared in
terms of active and reactive power flows in the line and active and
reactive power flows at the bus to analyze the performance of UPFC.
Abstract: This paper presents a novel CMOS four-transistor
SRAM cell for very high density and low power embedded SRAM
applications as well as for stand-alone SRAM applications. This cell
retains its data with leakage current and positive feedback without
refresh cycle. The new cell size is 20% smaller than a conventional
six-transistor cell using same design rules. Also proposed cell uses
two word-lines and one pair bit-line. Read operation perform from
one side of cell, and write operation perform from another side of
cell, and swing voltage reduced on word-lines thus dynamic power
during read/write operation reduced. The fabrication process is fully
compatible with high-performance CMOS logic technologies,
because there is no need to integrate a poly-Si resistor or a TFT load.
HSPICE simulation in standard 0.25μm CMOS technology confirms
all results obtained from this paper.
Abstract: Optimal load shedding (LS) design as an emergency plan is one of the main control challenges posed by emerging new uncertainties and numerous distributed generators including renewable energy sources in a modern power system. This paper presents an overview of the key issues and new challenges on optimal LS synthesis concerning the integration of wind turbine units into the power systems. Following a brief survey on the existing LS methods, the impact of power fluctuation produced by wind powers on system frequency and voltage performance is presented. The most LS schemas proposed so far used voltage or frequency parameter via under-frequency or under-voltage LS schemes. Here, the necessity of considering both voltage and frequency indices to achieve a more effective and comprehensive LS strategy is emphasized. Then it is clarified that this problem will be more dominated in the presence of wind turbines.
Abstract: The steady-state operation of maintaining voltage
stability is done by switching various controllers scattered all over
the power network. When a contingency occurs, whether forced or
unforced, the dispatcher is to alleviate the problem in a minimum
time, cost, and effort. Persistent problem may lead to blackout. The
dispatcher is to have the appropriate switching of controllers in terms
of type, location, and size to remove the contingency and maintain
voltage stability. Wrong switching may worsen the problem and that
may lead to blackout. This work proposed and used a Fuzzy CMeans
Clustering (FCMC) to assist the dispatcher in the decision
making. The FCMC is used in the static voltage stability to map
instantaneously a contingency to a set of controllers where the types,
locations, and amount of switching are induced.
Abstract: In North America, Most power distribution systems
employ a four-wire multi-grounded neutral (MGN) design. This paper has explained the inherent characteristics of multi-grounded three-phase four-wire distribution systems under unbalanced
situations. As a result, the mechanism of voltage swell and voltage sag in MGN feeders becomes difficult to understand. The simulation
tool that has been used in this paper is MATLAB under Windows software. In this paper the equivalent model of a full-scale multigrounded
distribution system implemented by MATLAB is
introduced. The results are expected to help utility engineers to understand the impact of MGN on distribution system operations.
Abstract: This paper describes the speed sensorless vector control method of the parallel connected induction motor drive fed by a single inverter. Speed and rotor fluxes of the induction motor are estimated by natural observer with load torque adaptation and adaptive rotor flux observer. The performance parameters speed and rotor fluxes are estimated from the measured terminal voltages and currents. Fourth order induction motor model is used and speed is considered as a parameter. The performance of the natural observer is similar to the conventional observer. The speed of an induction motor is estimated by MATLAB simulation under different speed and load conditions. Estimated values along with other measured states are used for closed loop control. The simulation results show that the natural observer is also effective for parallel connected induction motor drive.
Abstract: The application of a simple microcontroller to deal
with a three variable input and a single output fuzzy logic controller,
with Proportional – Integral – Derivative (PID) response control
built-in has been tested for an automatic voltage regulator. The
fuzzifiers are based on fixed range of the variables of output voltage.
The control output is used to control the wiper motor of the auto
transformer to adjust the voltage, using fuzzy logic principles, so that
the voltage is stabilized. In this report, the author will demonstrate
how fuzzy logic might provide elegant and efficient solutions in the
design of multivariable control based on experimental results rather
than on mathematical models.
Abstract: The condition of lightning surge causes the traveling waves and the temporary increase in voltage in the transmission line system. Lightning is the most harmful for destroying the transmission line and setting devices so it is necessary to study and analyze the temporary increase in voltage for designing and setting the surge arrester. This analysis describes the figure of the lightning wave in transmission line with 115 kV voltage level in Thailand by using ATP/EMTP program to create the model of the transmission line and lightning surge. Because of the limit of this program, it must be calculated for the geometry of the transmission line and surge parameter and calculation in the manual book for the closest value of the parameter. On the other hand, for the effects on surge protector when the lightning comes, the surge arrester model must be right and standardized as metropolitan electrical authority's standard. The candidate compared the real information to the result from calculation, also. The results of the analysis show that the temporary increase in voltage value will be rise to 326.59 kV at the line which is done by lightning when the surge arrester is not set in the system. On the other hand, the temporary increase in voltage value will be 182.83 kV at the line which is done by lightning when the surge arrester is set in the system and the period of the traveling wave is reduced, also. The distance for setting the surge arrester must be as near to the transformer as possible. Moreover, it is necessary to know the right distance for setting the surge arrester and the size of the surge arrester for preventing the temporary increase in voltage, effectively.
Abstract: An envelope echo signal measurement is proposed in
this paper using echo signal observation from the 200 kHz echo
sounder receiver. The envelope signal without any object is compared
with the envelope signal of the sphere. Two diameter size steel ball
(3.1 cm & 2.2 cm) and two diameter size air filled stainless steel ball
(4.8 cm & 7.4 cm) used in this experiment. The target was positioned
about 0.5 m and 1.0 meter from the transducer face using nylon rope.
From the echo observation in time domain, it is obviously shown that
echo signal structure is different between the size, distance and type
of metal sphere. The amplitude envelope voltage for the bigger
sphere is higher compare to the small sphere and it confirm that the
bigger sphere have higher target strength compare to the small
sphere. Although the structure signal without any object are different
compare to the signal from the sphere, the reflected signal from the
tank floor increase linearly with the sphere size. We considered this
event happened because of the object position approximately to the
tank floor.
Abstract: In this paper, we present the design and experimental
evaluation of complementary energy path adiabatic logic (CEPAL)
based 1 bit full adder circuit. A simulative investigation on the
proposed full adder has been done using VIRTUOSO SPECTRE
simulator of cadence in 0.18μm UMC technology and its
performance has been compared with the conventional CMOS full
adder circuit. The CEPAL based full adder circuit exhibits the energy
saving of 70% to the conventional CMOS full adder circuit, at 100
MHz frequency and 1.8V operating voltage.
Abstract: Consumer electronics are pervasive. It is impossible to
imagine a household or office without DVD players, digital cameras,
printers, mobile phones, shavers, electrical toothbrushes, etc. All
these devices operate at different voltage levels ranging from 1.8 to
20 VDC, in the absence of universal standards. The voltages
available are however usually 120/230 VAC at 50/60 Hz. This
situation makes an individual electrical energy conversion system
necessary for each device. Such converters usually involve several
conversion stages and often operate with excessive losses and poor
reliability. The aim of the project presented in this paper is to design
and implement a multi-channel DC/DC converter system,
customizing the output voltage and current ratings according to the
requirements of the load. Distributed, multi-agent techniques will be
applied for the control of the DC/DC converters.
Abstract: In this paper, a new K-means clustering based
approach for identification of voltage control areas is developed.
Voltage control areas are important for efficient reactive power
management in power systems operating under deregulated
environment. Although, voltage control areas are formed using
conventional hierarchical clustering based method, but the present
paper investigate the capability of K-means clustering for the
purpose of forming voltage control areas. The proposed method is
tested and compared for IEEE 14 bus and IEEE 30 bus systems. The
results show that this K-means based method is competing with
conventional hierarchical approach
Abstract: Power flow (PF) study, which is performed to
determine the power system static states (voltage magnitudes and
voltage angles) at each bus to find the steady state operating
condition of a system, is very important and is the most frequently
carried out study by power utilities for power system planning,
operation and control. In this paper, a counterpropagation neural
network (CPNN) is proposed to solve power flow problem under
different loading/contingency conditions for computing bus voltage
magnitudes and angles of the power system. The counterpropagation
network uses a different mapping strategy namely
counterpropagation and provides a practical approach for
implementing a pattern mapping task, since learning is fast in this
network. The composition of the input variables for the proposed
neural network has been selected to emulate the solution process of a
conventional power flow program. The effectiveness of the proposed
CPNN based approach for solving power flow is demonstrated by
computation of bus voltage magnitudes and voltage angles for
different loading conditions and single line-outage contingencies in
IEEE 14-bus system.
Abstract: Wastages such as grated coconut meat, spent tea and used sugarcane had contributed negative impacts to the environment. Vermicomposting method is fully utilized to manage the wastes towards a more sustainable approach. The worms that are used in the vermicomposting are Eisenia foetida and Eudrillus euginae. This research shows that the vermicompost of wastages has voltage of electrical energy and is able to light up the Light-Emitting Diode (LED) device. Based on the experiment, the use of replicated and double compartments of the component will produce double of voltage. Hence, for conclusion, this harmless and low cost technology of vermicompost can act as a dry cell in order to reduce the usage of hazardous chemicals that can contaminate the environment.
Abstract: The resistive-inductive-capacitive behavior of long
interconnects which are driven by CMOS gates are presented in this
paper. The analysis is based on the ¤Ç-model of a RLC load and is
developed for submicron devices. Accurate and analytical
expressions for the output load voltage, the propagation delay and the
short circuit power dissipation have been proposed after solving a
system of differential equations which accurately describe the
behavior of the circuit. The effect of coupling capacitance between
input and output and the short circuit current on these performance
parameters are also incorporated in the proposed model. The
estimated proposed delay and short circuit power dissipation are in
very good agreement with the SPICE simulation with average
relative error less than 6%.
Abstract: Repetitive control and feedback dithering modulation
are applied to a single-phase voltage source inverter, with an aim to
eliminate harmonics and stabilize the inverter under load variations.
The proposed control and modulation scheme comprise multiple loops
of feedback, which helps improve inverter performance and
robustness. Experimental results show that the designed inverter
exhibits very low distortion at its output with THD of about 0.3%
under different load variations.
Abstract: The object of this paper is to design and analyze a
proportional – integral (PI) control for positive output elementary
super lift Luo converter (POESLLC), which is the start-of-the-art
DC-DC converter. The positive output elementary super lift Luo
converter performs the voltage conversion from positive source
voltage to positive load voltage. This paper proposes a
development of PI control capable of providing the good static and
dynamic performance compared to proportional – integralderivative
(PID) controller. Using state space average method
derives the dynamic equations describing the positive output
elementary super lift luo converter and PI control is designed. The
simulation model of the positive output elementary super lift Luo
converter with its control circuit is implemented in
Matlab/Simulink. The PI control for positive output elementary
super lift Luo converter is tested for transient region, line changes,
load changes, steady state region and also for components
variations.
Abstract: The influence of axial magnetic field (B=0.48 T) on
the variation of ionization efficiency coefficient h and secondary
electron emission coefficient g with respect to reduced electric field
E/P is studied at a new range of plane-parallel electrode spacing (0<
d< 20 cm) and different nitrogen working pressure between 0.5-20
Pa. The axial magnetic field is produced from an inductive copper
coil of radius 5.6 cm. The experimental data of breakdown voltage is
adopted to estimate the mean Paschen curves at different working
features. The secondary electron emission coefficient is calculated
from the mean Paschen curve and used to determine the minimum
breakdown voltage. A reduction of discharge voltage of about 25% is
investigated by the applied of axial magnetic field. At high interelectrode
spacing, the effect of axial magnetic field becomes more
significant for the obtained values of h but it was less for the values
of g.