Abstract: Optimal load shedding (LS) design as an emergency plan is one of the main control challenges posed by emerging new uncertainties and numerous distributed generators including renewable energy sources in a modern power system. This paper presents an overview of the key issues and new challenges on optimal LS synthesis concerning the integration of wind turbine units into the power systems. Following a brief survey on the existing LS methods, the impact of power fluctuation produced by wind powers on system frequency and voltage performance is presented. The most LS schemas proposed so far used voltage or frequency parameter via under-frequency or under-voltage LS schemes. Here, the necessity of considering both voltage and frequency indices to achieve a more effective and comprehensive LS strategy is emphasized. Then it is clarified that this problem will be more dominated in the presence of wind turbines.
Abstract: This paper presents a novel CMOS four-transistor
SRAM cell for very high density and low power embedded SRAM
applications as well as for stand-alone SRAM applications. This cell
retains its data with leakage current and positive feedback without
refresh cycle. The new cell size is 20% smaller than a conventional
six-transistor cell using same design rules. Also proposed cell uses
two word-lines and one pair bit-line. Read operation perform from
one side of cell, and write operation perform from another side of
cell, and swing voltage reduced on word-lines thus dynamic power
during read/write operation reduced. The fabrication process is fully
compatible with high-performance CMOS logic technologies,
because there is no need to integrate a poly-Si resistor or a TFT load.
HSPICE simulation in standard 0.25μm CMOS technology confirms
all results obtained from this paper.
Abstract: In this paper the performance of unified power flow
controller is investigated in controlling the flow of po wer over the
transmission line. Voltage sources model is utilized to study the
behaviour of the UPFC in regulating the active, reactive power and
voltage profile. This model is incorporated in Newton Raphson
algorithm for load flow studies. Simultaneous method is employed
in which equations of UPFC and the power balance equations of
network are combined in to one set of non-linear algebraic equations.
It is solved according to the Newton raphson algorithm. Case studies
are carried on standard 5 bus network. Simulation is done in Matlab.
The result of network with and without using UPFC are compared in
terms of active and reactive power flows in the line and active and
reactive power flows at the bus to analyze the performance of UPFC.
Abstract: In this paper, the application of multiple Elman neural networks to time series data regression problems is studied. An ensemble of Elman networks is formed by boosting to enhance the performance of the individual networks. A modified version of the AdaBoost algorithm is employed to integrate the predictions from multiple networks. Two benchmark time series data sets, i.e., the Sunspot and Box-Jenkins gas furnace problems, are used to assess the effectiveness of the proposed system. The simulation results reveal that an ensemble of boosted Elman networks can achieve a higher degree of generalization as well as performance than that of the individual networks. The results are compared with those from other learning systems, and implications of the performance are discussed.
Abstract: In this paper we consider a nonlinear feedback control
called augmented automatic choosing control (AACC) using the
gradient optimization automatic choosing functions for nonlinear
systems. Constant terms which arise from sectionwise linearization
of a given nonlinear system are treated as coefficients of a stable
zero dynamics. Parameters included in the control are suboptimally
selected by expanding a stable region in the sense of Lyapunov
with the aid of the genetic algorithm. This approach is applied to
a field excitation control problem of power system to demonstrate
the splendidness of the AACC. Simulation results show that the new
controller can improve performance remarkably well.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. Fueling the attention have been the possibilities of international agreements to reduce greenhouse gas emissions, electricity sector restructuring, high power reliability requirements for certain activities, and concern about easing transmission and distribution capacity bottlenecks and congestion. So it is necessary that impact of these kinds of generators on distribution feeder reconfiguration would be investigated. This paper presents an approach for distribution reconfiguration considering Distributed Generators (DGs). The objective function is summation of electrical power losses A Tabu search optimization is used to solve the optimal operation problem. The approach is tested on a real distribution feeder.
Abstract: The intent of this essay is to evaluate the effectiveness
of surge suppressor aimed at power supply used for automation
devices in power distribution system which is consist of MOV and
T type low-pass filter. Books, journal articles and e-sources related
to surge protection of power supply used for automation devices in
power distribution system were consulted, and the useful information
was organized, analyzed and developed into five parts: characteristics
of surge wave, protection against surge wave, impedance characteristics
of target, using Matlab to simulate circuit response after
5kV,1.2/50s surge wave and suggestions for surge protection. The
results indicate that various types of load situation have great impact
on the effectiveness of surge protective device. Therefore, type and
parameters of surge protective device need to be carefully selected,
and load matching is also vital to be concerned.
Abstract: This paper investigates the nature of the development
of two-dimensional laminar flow of an incompressible fluid at the
reversed stagnation-point. ". In this study, we revisit the problem
of reversed stagnation-point flow over a flat plate. Proudman and
Johnson (1962) first studied the flow and obtained an asymptotic
solution by neglecting the viscous terms. This is no true in neglecting
the viscous terms within the total flow field. In particular it is pointed
out that for a plate impulsively accelerated from rest to a constant
velocity V0 that a similarity solution to the self-similar ODE is
obtained which is noteworthy completely analytical.
Abstract: This paper presents the DC voltage control design of D-STATCOM when the D-STATCOM is used for load voltage regulation. Although, the DC voltage can be controlled by active current of the D-STATCOM, reactive current still affects the DC voltage. To eliminate this effect, the control strategy with elimination effect of the reactive current is proposed and the results of the control with and without the elimination the effect of the reactive current are compared. For obtaining the proportional and integral gains of the PI controllers, the symmetrical optimum and genetic algorithms methods are applied. The stability margin of these methods are obtained and discussed in detail. In addition, the performance of the DC voltage control based on symmetrical optimum and genetic algorithms methods are compared. Effectiveness of the controllers designed was verified through computer simulation performed by using Power System Tool Block (PSB) in SIMULINK/MATLAB. The simulation results demonstrated that the DC voltage control proposed is effective in regulating DC voltage when the DSTATCOM is used for load voltage regulation.
Abstract: The interline power flow controller (IPFC) is one of
the latest generation flexible AC transmission systems (FACTS)
controller used to control power flows of multiple transmission lines.
This paper presents a mathematical model of IPFC, termed as power
injection model (PIM). This model is incorporated in Newton-
Raphson (NR) power flow algorithm to study the power flow control
in transmission lines in which IPFC is placed. A program in
MATLAB has been written in order to extend conventional NR
algorithm based on this model. Numerical results are carried out on a
standard 2 machine 5 bus system. The results without and with IPFC
are compared in terms of voltages, active and reactive power flows to
demonstrate the performance of the IPFC model.
Abstract: This paper proposes a set of quasi-static mathematical
model of magnetic fields caused by high voltage conductors of
distribution transformer by using a set of second-order partial
differential equation. The modification for complex magnetic field
analysis and time-harmonic simulation are also utilized. In this
research, transformers were study in both balanced and unbalanced
loading conditions. Computer-based simulation utilizing the threedimensional
finite element method (3-D FEM) is exploited as a tool
for visualizing magnetic fields distribution volume a distribution
transformer. Finite Element Method (FEM) is one among popular
numerical methods that is able to handle problem complexity in
various forms. At present, the FEM has been widely applied in most
engineering fields. Even for problems of magnetic field distribution,
the FEM is able to estimate solutions of Maxwell-s equations
governing the power transmission systems. The computer simulation
based on the use of the FEM has been developed in MATLAB
programming environment.
Abstract: This paper proposes the method combining artificial
neural network (ANN) with particle swarm optimization (PSO) to
implement the maximum power point tracking (MPPT) by controlling
the rotor speed of the wind generator. First, the measurements of wind
speed, rotor speed of wind power generator and output power of wind
power generator are applied to train artificial neural network and to
estimate the wind speed. Second, the method mentioned above is
applied to estimate and control the optimal rotor speed of the wind
turbine so as to output the maximum power. Finally, the result reveals
that the control system discussed in this paper extracts the maximum
output power of wind generator within the short duration even in the
conditions of wind speed and load impedance variation.
Abstract: Classifier fusion may generate more accurate
classification than each of the basic classifiers. Fusion is often based
on fixed combination rules like the product, average etc. This paper
presents decision templates as classifier fusion method for the
recognition of the handwritten English and Farsi numerals (1-9).
The process involves extracting a feature vector on well-known
image databases. The extracted feature vector is fed to multiple
classifier fusion. A set of experiments were conducted to compare
decision templates (DTs) with some combination rules. Results from
decision templates conclude 97.99% and 97.28% for Farsi and
English handwritten digits.
Abstract: In this paper, we apply the PQ theory with shunt active power filter in an unbalanced and distorted power system voltage to compensate the perturbations generated by non linear load. The power factor is also improved in the current source. The PLL system is used to extract the fundamental component of the even sequence under conditions mentioned of the power system voltage.
Abstract: The information revealed by derivatives can help to
better characterize digital near-end crosstalk signatures with the
ultimate goal of identifying the specific aggressor signal.
Unfortunately, derivatives tend to be very sensitive to even low
levels of noise. In this work we approximated the derivatives of both
quiet and noisy digital signals using a wavelet-based technique. The
results are presented for Gaussian digital edges, IBIS Model digital
edges, and digital edges in oscilloscope data captured from an actual
printed circuit board. Tradeoffs between accuracy and noise
immunity are presented. The results show that the wavelet technique
can produce first derivative approximations that are accurate to
within 5% or better, even under noisy conditions. The wavelet
technique can be used to calculate the derivative of a digital signal
edge when conventional methods fail.
Abstract: This paper discusses a genetic algorithm (GA) based optimal load shedding that can apply for electrical distribution networks with and without dispersed generators (DG). Also, the proposed method has the ability for considering constant and variable capacity deficiency caused by unscheduled outages in the bulked generation and transmission system of bulked power supply. The genetic algorithm (GA) is employed to search for the optimal load shedding strategy in distribution networks considering DGs in two cases of constant and variable modelling of bulked power supply of distribution networks. Electrical power distribution systems have a radial network and unidirectional power flows. With the advent of dispersed generations, the electrical distribution system has a locally looped network and bidirectional power flows. Therefore, installed DG in the electrical distribution systems can cause operational problems and impact on existing operational schemes. Introduction of DGs in electrical distribution systems has introduced many new issues in operational and planning level. Load shedding as one of operational issue has no exempt. The objective is to minimize the sum of curtailed load and also system losses within the frame-work of system operational and security constraints. The proposed method is tested on a radial distribution system with 33 load points for more practical applications.
Abstract: The performance of time-reversal MUSIC algorithm will be dramatically degrades in presence of strong noise and multiple scattering (i.e. when scatterers are close to each other). This is due to error in determining the number of scatterers. The present paper provides a new approach to alleviate such a problem using an information theoretic criterion referred as minimum description length (MDL). The merits of the novel approach are confirmed by the numerical examples. The results indicate the time-reversal MUSIC yields accurate estimate of the target locations with considerable noise and multiple scattering in the received signals.
Abstract: An optical fault monitoring in FTTH-PON using ACS
is demonstrated. This device can achieve real-time fault monitoring
for protection feeder fiber. In addition, the ACS can distinguish
optical fiber fault from the transmission services to other customers
in the FTTH-PON. It is essential to use a wavelength different from
the triple-play services operating wavelengths for failure detection.
ACS is using the operating wavelength 1625 nm for monitoring and
failure detection control. Our solution works on a standard local area
network (LAN) using a specially designed hardware interfaced with a
microcontroller integrated Ethernet.
Abstract: In this paper, the least-squares design of variable fractional-delay (VFD) finite impulse response (FIR) digital differentiators is proposed. The used transfer function is formulated so that Farrow structure can be applied to realize the designed system. Also, the symmetric characteristics of filter coefficients are derived, which leads to the complexity reduction by saving almost a half of the number of coefficients. Moreover, all the elements of related vectors or matrices for the optimal process can be represented in closed forms, which make the design easier. Design example is also presented to illustrate the effectiveness of the proposed method.
Abstract: In this paper we consider the problem of distributed adaptive estimation in wireless sensor networks for two different observation noise conditions. In the first case, we assume that there are some sensors with high observation noise variance (noisy sensors) in the network. In the second case, different variance for observation noise is assumed among the sensors which is more close to real scenario. In both cases, an initial estimate of each sensor-s observation noise is obtained. For the first case, we show that when there are such sensors in the network, the performance of conventional distributed adaptive estimation algorithms such as incremental distributed least mean square (IDLMS) algorithm drastically decreases. In addition, detecting and ignoring these sensors leads to a better performance in a sense of estimation. In the next step, we propose a simple algorithm to detect theses noisy sensors and modify the IDLMS algorithm to deal with noisy sensors. For the second case, we propose a new algorithm in which the step-size parameter is adjusted for each sensor according to its observation noise variance. As the simulation results show, the proposed methods outperforms the IDLMS algorithm in the same condition.