Abstract: In this paper the authors propose a flexible electronic solution, to improve the energetic efficiency of a thermo plant. This is achieved by replacing the mechanical gear box, placed traditionally between a gas turbine and a synchronous generator; by a power electronic converter. After reminding problematic of gear boxes and interest of a proposed electronic solution in high power plants, the authors describe a new control strategy for an indirect frequency converter, which is characterized by its high efficiency due to the use of SWM: Square Wave Modulation. The main advantage of this mode is the quasi absence of switching losses. A control method is also proposed to resolve some problems incurred by using square wave modulation, in particular to reduce the harmonics distortion of the output inverter voltage and current. Simulation examples as well as experimental results are included.
Abstract: The motivation for adaptive modulation and coding is
to adjust the method of transmission to ensure that the maximum
efficiency is achieved over the link at all times. The receiver
estimates the channel quality and reports it back to the transmitter.
The transmitter then maps the reported quality into a link mode. This
mapping however, is not a one-to-one mapping. In this paper we
investigate a method for selecting the proper modulation scheme.
This method can dynamically adapt the mapping of the Signal-to-
Noise Ratio (SNR) into a link mode. It enables the use of the right
modulation scheme irrespective of changes in the channel conditions
by incorporating errors in the received data. We propose a Markov
model for this method, and use it to derive the average switching
thresholds and the average throughput. We show that the average
throughput of this method outperforms the conventional threshold
method.
Abstract: To maximise furnace production it-s necessary to
optimise furnace control, with the objectives of achieving maximum
power input into the melting process, minimum network distortion
and power-off time, without compromise on quality and safety. This
can be achieved with on the one hand by an appropriate electrode
control and on the other hand by a minimum of AC transformer
switching.
Electrical arc is a stochastic process; witch is the principal cause
of power quality problems, including voltages dips, harmonic
distortion, unbalance loads and flicker. So it is difficult to make an
appropriate model for an Electrical Arc Furnace (EAF). The factors
that effect EAF operation are the melting or refining materials,
melting stage, electrode position (arc length), electrode arm control
and short circuit power of the feeder. So arc voltages, current and
power are defined as a nonlinear function of the arc length. In this
article we propose our own empirical function of the EAF and model,
for the mean stages of the melting process, thanks to the
measurements in the steel factory.
Abstract: The range of the output power is a very important and evident limitation of two-level inverters. In order to overcome this disadvantage, multilevel inverters are introduced. Recently, Cascade H-Bridge inverters have emerged as one of the popular converter topologies used in numerous industrial applications. The modulation switching strategies such as phase shifted carrier based Pulse Width Modulation (PWM) technique and Stair case modulation with Selective Harmonic Elimination (SHE) PWM technique are generally used. NR method is used to solve highly non linear transcendental equations which are formed by SHEPWM method. Generally NR method has a drawback of requiring good initial guess but in this paper a new approach is implemented for NR method with any random initial guess. A three phase CHB 11-level inverter is chosen for analysis. MATLAB/SIMULINK programming environment and harmonic profiles are compared. Finally this paper presents a method at fundamental switching frequency with least % THDV.
Abstract: In this paper, genetic algorithm (GA) is proposed for
the design of an optimization algorithm to achieve the bandwidth
allocation of ATM network. In Broadband ISDN, the ATM is a highbandwidth;
fast packet switching and multiplexing technique. Using
ATM it can be flexibly reconfigure the network and reassign the
bandwidth to meet the requirements of all types of services. By
dynamically routing the traffic and adjusting the bandwidth
assignment, the average packet delay of the whole network can be
reduced to a minimum. M/M/1 model can be used to analyze the
performance.
Abstract: In a bi-fuel diesel engine, the carburetor plays a vital
role in switching from fuel gas to petrol mode operation and viceversa.
The carburetor is the most important part of the fuel system of
a diesel engine. All diesel engines carry variable venturi mixer
carburetors. The basic operation of the carburetor mainly depends on
the restriction barrel called the venturi. When air flows through the
venturi, its speed increases and its pressure decreases. The main
challenge focuses on designing a mixing device which mixes the
supplied gas is the incoming air at an optimum ratio. In order to
surmount the identified problems, the way fuel gas and air flow in
the mixer have to be analyzed. In this case, the Computational Fluid
Dynamics or CFD approach is applied in design of the prototype
mixer. The present work is aimed at further understanding of the air
and fuel flow structure by performing CFD studies using a software
code. In this study for mixing air and gas in the condition that has
been mentioned in continuance, some mixers have been designed.
Then using of computational fluid dynamics, the optimum mixer has
been selected. The results indicated that mixer with 12 holes can
produce a homogenous mixture than those of 8-holes and 6-holes
mixer. Also the result showed that if inlet convergency was smoother
than outlet divergency, the mixture get more homogenous, the reason
of that is in increasing turbulence in outlet divergency.
Abstract: Inthis paper, design and fabrication of vertical
micromirror for optical switching applications of single mode optical
fibers are proposed. The structure of micromirror will be created
from negative photoresist (SU-8) on X-ray lithography using X-ray
from synchrotron light source. The properties of X-ray from
synchrotron light source are high-energy electrons which can
construct materials that have a high aspect ratio. In addition, the
technique of gold coating of reflective material has been used for
change direction of light between two pairs of optical fibers. At a
wavelength of 1310 nm with minimum average loss of 5.305 dB is
obtained.
Abstract: The proper selection of the AC-side passive filter
interconnecting the voltage source converter to the power supply is
essential to obtain satisfactory performances of an active power filter
system. The use of the LCL-type filter has the advantage of
eliminating the high frequency switching harmonics in the current
injected into the power supply. This paper is mainly focused on
analyzing the influence of the interface filter parameters on the active
filtering performances. Some design aspects are pointed out. Thus,
the design of the AC interface filter starts from transfer functions by
imposing the filter performance which refers to the significant current
attenuation of the switching harmonics without affecting the
harmonics to be compensated. A Matlab/Simulink model of the entire
active filtering system including a concrete nonlinear load has been
developed to examine the system performances. It is shown that a
gamma LC filter could accomplish the attenuation requirement of the
current provided by converter. Moreover, the existence of an optimal
value of the grid-side inductance which minimizes the total harmonic
distortion factor of the power supply current is pointed out.
Nevertheless, a small converter-side inductance and a damping
resistance in series with the filter capacitance are absolutely needed
in order to keep the ripple and oscillations of the current at the
converter side within acceptable limits. The effect of change in the
LCL-filter parameters is evaluated. It is concluded that good active
filtering performances can be achieved with small values of the
capacitance and converter-side inductance.
Abstract: A novel interpolation scheme to extend usable spectrum
and upconvert in high performance D/A converters is addressed in this
paper. By adjusting the pulse width of cycle and the production circuit
of code, the expansion code is a null code or complementary code that
is interpolation process. What the times and codes of interpolation
decide DAC works in one of a normal mode or multi-mixer mode
so that convert the input digital data signal into normal signal or a
mixed analog signal having a mixer frequency that is higher than the
data frequency. Simulation results show that the novel scheme and
apparatus most extend the usable frequency spectrum into fifth to
sixth Nyquist zone beyond conventional DACs.
Abstract: High performance Resistive Random Access Memory
(RRAM) based on HfOx has been prepared and its temperature
instability has been investigated in this work. With increasing
temperature, it is found that: leakage current at high resistance state
increases, which can be explained by the higher density of traps
inside dielectrics (related to trap-assistant tunneling), leading to a
smaller On/Off ratio; set and reset voltages decrease, which may be
attributed to the higher oxygen ion mobility, in addition to the
reduced potential barrier to create / recover oxygen ions (or oxygen
vacancies); temperature impact on the RRAM retention degradation
is more serious than electrical bias.
Abstract: An on-line condition monitoring method for transmission line is proposed using electrical circuit theory and IT technology in this paper. It is reasonable that the circuit parameters such as resistance (R), inductance (L), conductance (g) and capacitance (C) of a transmission line expose the electrical conditions and physical state of the line. Those parameters can be calculated from the linear equation composed of voltages and currents measured by synchro-phasor measurement technique at both end of the line. A set of linear voltage drop equations containing four terminal constants (A, B ,C ,D ) are mathematical models of the transmission line circuits. At least two sets of those linear equations are established from different operation condition of the line, they may mathematically yield those circuit parameters of the line. The conditions of line connectivity including state of connecting parts or contacting parts of the switching device may be monitored by resistance variations during operation. The insulation conditions of the line can be monitored by conductance (g) and capacitance(C) measurements. Together with other condition monitoring devices such as partial discharge, sensors and visual sensing device etc.,they may give useful information to monitor out any incipient symptoms of faults. The prototype of hardware system has been developed and tested through laboratory level simulated transmission lines. The test has shown enough evident to put the proposed method to practical uses.
Abstract: This paper, a simple continuous conduction mode (CCM) pulse-width-modulated (PWM) controller for high power factor boost converters is introduced. The duty ratios were obtained by the comparison of a sensed signal from inductor current or switch current and a negative slope ramp carrier waveform in each switching period. Due to the proposed control requires only the inductor current or switch current sensor and the output voltage sensor, its circuit implementation was very simple. To verify the proposed control, the circuit experimentation of a 350 W boost converter with the proposed control was applied. From the results, the input current waveform was shaped to be closely sinusoidal, implying high power factor and low harmonics.
Abstract: By analyzing the sources of energy and power
loss in PWM (Pulse Width Modulation) controlled drivers of
water electrolysis cells, it is possible to reduce the power
dissipation and enhance the efficiency of such hydrogen
production units. A PWM controlled power driver is based on
a semiconductor switching element where its power
dissipation might be a remarkable fraction of the total power
demand of an electrolysis system. Power dissipation in a
semiconductor switching element is related to many different
parameters which could be fitted into two main categories:
switching losses and conduction losses. Conduction losses are
directly related to the built, structure and capabilities of a
switching device itself and indeed the conditions in which the
element is handling the switching application such as voltage,
current, temperature and of course the fabrication technology.
On the other hand, switching losses have some other
influencing variables other than the mentioned such as control
system, switching method and power electronics circuitry of
the PWM power driver. By analyzings the characteristics of
recently developed power switching transistors from different
families of Bipolar Junction Transistors (BJT), Metal Oxide
Semiconductor Field Effect Transistors (MOSFET) and
Insulated Gate Bipolar Transistors (IGBT), some
recommendations are made in this paper which are able to
lead to achieve higher hydrogen production efficiency by
utilizing PWM controlled water electrolysis cells.
Abstract: In this paper, the problem of reducing switching
activity in on-chip buses at the stage of high-level synthesis is
considered, and a high-level low power bus binding based on dynamic
bit reordering is proposed. Whereas conventional methods use a fixed
bit ordering between variables within a bus, the proposed method
switches a bit ordering dynamically to obtain a switching activity
reduction. As a result, the proposed method finds a binding solution
with a smaller value of total switching activity (TSA). Experimental
result shows that the proposed method obtains a binding solution
having 12.0-34.9% smaller TSA compared with the conventional
methods.
Abstract: Average current analysis checking the impact of
current flow is very important to guarantee the reliability of
semiconductor systems. As semiconductor process technologies
improve, the coupling capacitance often become bigger than self
capacitances. In this paper, we propose an analytic technique for
analyzing average current on interconnects in multi-conductor
structures. The proposed technique has shown to yield the acceptable
errors compared to HSPICE results while providing computational
efficiency.
Abstract: It is known that if harmonic spectra are decreased, then
acoustic noise also decreased. Hence, this paper deals with a new
random switching strategy using DSP TMS320F2812 to decrease the
harmonics spectra of single phase switched reluctance motor. The
proposed method which combines random turn-on, turn-off angle
technique and random pulse width modulation technique is shown. A
harmonic spread factor (HSF) is used to evaluate the random
modulation scheme. In order to confirm the effectiveness of the new
method, the experimental results show that the harmonic intensity of
output voltage for the proposed method is better than that for
conventional methods.
Abstract: In this paper a neural adaptive control method has
been developed and applied to robot control. Simulation results are
presented to verify the effectiveness of the controller. These results
show that the performance by using this controller is better than
those which just use either direct inverse control or predictive
control. In addition, they show that the resulting is a useful method
which combines the advantages of both direct inverse control and
predictive control.
Abstract: In the past decade, because of wide applications of
hybrid systems, many researchers have considered modeling and
control of these systems. Since switching systems constitute an
important class of hybrid systems, in this paper a method for optimal
control of linear switching systems is described. The method is also
applied on the two-tank system which is a much appropriate system
to analyze different modeling and control techniques of hybrid
systems. Simulation results show that, in this method, the goals of
control and also problem constraints can be satisfied by an
appropriate selection of cost function.