On the AC-Side Interface Filter in Three-Phase Shunt Active Power Filter Systems

The proper selection of the AC-side passive filter interconnecting the voltage source converter to the power supply is essential to obtain satisfactory performances of an active power filter system. The use of the LCL-type filter has the advantage of eliminating the high frequency switching harmonics in the current injected into the power supply. This paper is mainly focused on analyzing the influence of the interface filter parameters on the active filtering performances. Some design aspects are pointed out. Thus, the design of the AC interface filter starts from transfer functions by imposing the filter performance which refers to the significant current attenuation of the switching harmonics without affecting the harmonics to be compensated. A Matlab/Simulink model of the entire active filtering system including a concrete nonlinear load has been developed to examine the system performances. It is shown that a gamma LC filter could accomplish the attenuation requirement of the current provided by converter. Moreover, the existence of an optimal value of the grid-side inductance which minimizes the total harmonic distortion factor of the power supply current is pointed out. Nevertheless, a small converter-side inductance and a damping resistance in series with the filter capacitance are absolutely needed in order to keep the ripple and oscillations of the current at the converter side within acceptable limits. The effect of change in the LCL-filter parameters is evaluated. It is concluded that good active filtering performances can be achieved with small values of the capacitance and converter-side inductance.




References:
[1] M. Liserre, F. Blaabjerg, and S. Hansen, "Design and control of an
LCL-filter-based three-phase active rectifier," IEEE Trans. Ind. Appl.,
vol. 41, no. 5, pp. 1281-1291, 2005.
[2] Y. Lang, D. Xu, Hadianamrei S.R, and H. Ma, "A novel design method
of lcl type utility interface for three-phase voltage source rectifier," in
Proc. of 36th IEEE Power Electronics Specialists Conference, pp. 313-
317, 2005.
[3] P. Peltoniemi, R. Pollanen, M. Niemela, and J. Pyrhonen, "Comparison
of the effect of output filters on the total harmonic distortion of line
current in voltage source line converter - Simulation study," 2006, 5 s.,
ICREPQ 2006, Mallorca, Espanja, 2006.
[4] M. Liserre, A. Dell-Aquila, and F. Blaabjerg, "Genetic algorithm-based
design of the active damping for an LCL-filter three-phase active
rectifier," IEEE Trans. Power Electronics, vol. 19, no. 1, pp. 76-86,
2004.
[5] H.R. Karshenas and H. Saghafi, "Performance investigation of LCL
filters in grid connected converters, in Proc. IEEE PES Transmission
and Distribution Conference and Exposition, pp.1-6, 2006.
[6] E.J. Bueno, F. Espinosa, F.J. Rodriguez, J. Ureila, and S. Cobreces,
"Current control of voltage source converters connected to the grid
through an LCL-filter, in Proc of 35rh Annual IEEE Power Electronics
Specialisls Conference, vol.1, pp. 68 - 73, 2004.
[7] M. Lindgren and J. Svensson, "Control of a voltage source converter
connected to the grid through an LCL-filterÔÇöapplication to active
filtering," in Proc. of the IEEE PESC-98, vol. 1, pp. 229-235, 1998.
[8] S. Pettersson, M. Salo, and H. Tuusa, "Applying an LCL-filter to a fourwire
active power filter," in Proc.Power Electr. Specialists Conf.-
Pesc-06, pp.1413-1419, 2006.
[9] M. Routimo and H. Tuusa, "LCL type supply filter for active power
filter -Comparison of an active and a passive method for resonance
damping," in Proc. Power Electronics Specialists Conference, pp.
2939-2945, 2007.
[10] B. Bolsens, K. De Brabandere, J. Van den Keybus, J. Driesen, and R.
Belmans, "Model-based generation of low distortion currents in gridcoupled
PWM-inverters using an LCL output filter," IEEE Trans Power
Electronics, vol. 21, No. 4, pp.1032-1040, July 2006.