Abstract: The decreasing use of fossil fuel power stations has
a negative effect on the stability of the electricity systems in many
countries. Nuclear power stations have traditionally provided minimal
ancillary services to support the system but this must change in the
future as they replace fossil fuel generators. This paper explains the
development of the four most popular reactor types still in regular
operation across the world which have formed the basis for most
reactor development since their commercialisation in the 1950s. The
use of nuclear power in four countries with varying levels of capacity
provided by nuclear generators is investigated, using the primary
frequency response provided by generators as a measure for the
electricity networks stability, to assess the need for nuclear generators
to provide additional support as their share of the generation capacity
increases.
Abstract: The growth in the demand of electrical energy is
leading to load on the Power system which increases the occurrence
of frequent oscillations in the system. The reason for the oscillations
is due to the lack of damping torque which is required to dominate
the disturbances of Power system. By using FACT devices, such as
Unified Power Flow Controller (UPFC) can control power flow,
reduce sub-synchronous resonances and increase transient stability.
Hence, UPFC is used to damp the oscillations occurred in Power
system. This research focuses on adapting the neuro fuzzy controller
for the UPFC design by connecting the infinite bus (SMIB - Single
machine Infinite Bus) to a linearized model of synchronous machine
(Heffron-Phillips) in the power system. This model gains the
capability to improve the transient stability and to damp the
oscillations of the system.
Abstract: Current transformers are an integral part of power
system because it provides a proportional safe amount of current for
protection and measurement applications. However, when the power
system experiences an abnormal situation leading to huge current
flow, then this huge current is proportionally injected to the
protection and metering circuit. Since the protection and metering
equipment’s are designed to withstand only certain amount of current
with respect to time, these high currents pose a risk to man and
equipment. Therefore, during such instances, the CT saturation
characteristics have a huge influence on the safety of both man and
equipment and on the reliability of the protection and metering
system. This paper shows the effect of burden on the Accuracy Limiting
factor/ Instrument security factor of current transformers and the
change in saturation characteristics of the CT’s. The response of the
CT to varying levels of overcurrent at different connected burden will
be captured using the data acquisition software LabVIEW. Analysis
is done on the real time data gathered using LabVIEW. Variation of
current transformer saturation characteristics with changes in burden
will be discussed.
Abstract: The use of hydroelectric pump-storage system at large
scale, MW-size systems, is already widespread around the world.
Designed for large scale applications, pump-storage station can be
scaled-down for small, remote residential applications. Given the cost
and complexity associated with installing a substation further than
100 miles from the main transmission lines, a remote, independent
and self-sufficient system is by far the most feasible solution. This
article is aiming at the design of wind and solar power generating
system, by means of pumped-storage to replace the wind and /or solar
power systems with a battery bank energy storage. Wind and solar
pumped-storage power generating system can reduce the cost of
power generation system, according to the user's electricity load and
resource condition and also can ensure system reliability of power
supply. Wind and solar pumped-storage power generation system is
well suited for remote residential applications with intermittent wind
and/or solar energy. This type of power systems, installed in these
locations, could be a very good alternative, with economic benefits
and positive social effects. The advantage of pumped storage power
system, where wind power regulation is calculated, shows that a
significant smoothing of the produced power is obtained, resulting in
a power-on-demand system’s capability, concomitant to extra
economic benefits.
Abstract: Implementation of advanced technologies requires
sophisticated instruments that deal with the operation, control,
restoration and protection of rapidly growing power system network
under normal and abnormal conditions. Presently, the applications of
Phasor Measurement Unit (PMU) are widely found in real time
operation, monitoring, controlling and analysis of power system
network as it eliminates the various limitations of supervisory control
and data acquisition system (SCADA) conventionally used in power
system. The use of PMU data is very rapidly increasing its
importance for online and offline analysis. Wide area measurement
system (WAMS) is developed as new technology by use of multiple
PMUs in power system. The present paper proposes a model of
Matlab based PMU using Discrete Fourier Transform (DFT)
algorithm and evaluation of its operation under different
contingencies. In this paper, PMU based two bus system having
WAMS network is presented as a case study.
Abstract: In power system protection, the need to know the load
current together with the fault level detected by a relay is important.
This is due to the fact that the relay is required to isolate the
equipment being protected if a fault is present and keep the breaker
associated with it closed if the current level is lower than the
maximum load level. This is not an issue for a radial system. This is
not the same however in a looped power system. In a looped power
system, the isolation of an equipment system will contribute to a
topology change. The change in the power system topology will then
influence or change the maximum load current and the fault level
detected by each relay. In this paper, a method of data collection for
changing topology using matlab and sim-power will be presented.
The method will take into consideration the change in topology and
collect data for each possible topology.
Abstract: The power system network is becoming more
complex nowadays and it is very difficult to maintain the stability
of the system. Today-s enhancement of technology makes it
possible to include new energy storage devices in the electric
power system. In addition, with the aid of power electronic
devices, it is possible to independently exchange active and
reactive power flow with the utility grid. The main purpose of this
paper proposes a Proportional – Integral (PI) control based 48 –
pulse Inverter based Static Synchronous Series Compensator
(SSSC) with and without Superconducting Magnetic Energy
Storage (SMES) used for enhancing the transient stability and
regulating power flow in automatic mode. Using a test power
system through the dynamic simulation in Matlab/Simulink
platform validates the performance of the proposed SSSC with and
without SMES system.
Abstract: Power system stabilizers (PSS) must be capable of providing appropriate stabilization signals over a broad range of
operating conditions and disturbance. Traditional PSS rely on robust
linear design method in an attempt to cover a wider range of operating
condition. Expert or rule-based controllers have also been proposed.
Recently fuzzy logic (FL) as a novel robust control
design method has shown promising results. The emphasis in fuzzy
control design center is around uncertainties in the system parameters
& operating conditions. In this paper a novel Robust Fuzzy Logic Power
System Stabilizer (RFLPSS) design is proposed The RFLPSS
basically utilizes only one measurable Δω signal as input
(generator shaft speed).
The speed signal is discretized resulting in three inputs to the
RFLPSS. There are six rules for the fuzzification and two rules for
defuzzification. To provide robustness, additional signal namely,
speed are used as inputs to RFLPSS enabling appropriate gain
adjustments for the three RFLPSS inputs. Simulation studies
show the superior performance of the RFLPSS compared
with an optimally designed conventional PSS and discrete mode FLPSS.
Abstract: Harmonic pollution and low power factor in power
systems caused by power converters have been of great concern. To
overcome these problems several converter topologies using
advanced semiconductor devices and control schemes have been
proposed. This investigation is to identify a low cost, small size,
efficient and reliable ac to dc converter to meet the input performance
index of UPS. The performance of single phase and three phase ac to
dc converter along with various control techniques are studied and
compared. The half bridge converter topology with linear current
control is identified as most suitable. It is simple, energy efficient
because of single switch power loss and transformer-less operation of
UPS. The results are validated practically using a prototype built
using IGBT and analog controller. The performance for both single
and three-phase system is verified. Digital implementation of closed
loop control achieves higher reliability. Its cost largely depends on
chosen bit precision. The minimal bit precision for optimum
converter performance is identified as 16-bit with fixed-point
operation. From the investigation and practical implementation it is
concluded that half bridge ac – dc converter along with digital linear
controller meets the performance index of UPS for single and three
phase systems.
Abstract: The ability to detect and classify the type of fault
plays a great role in the protection of power system. This procedure
is required to be precise with no time consumption. In this paper
detection of fault type has been implemented using wavelet analysis
together with wavelet entropy principle. The simulation of power
system is carried out using PSCAD/EMTDC. Different types of
faults were studied obtaining various current waveforms. These
current waveforms were decomposed using wavelet analysis into
different approximation and details. The wavelet entropy of such
decompositions is analyzed reaching a successful methodology for
fault classification. The suggested approach is tested using different
fault types and proven successful identification for the type of fault.
Abstract: This paper discusses aspects of re-design of loadshedding
schemes with respect to actual developments in the Kosovo
power system. Load-shedding is a type of emergency control that is
designed to ensure system stability by reducing power system load to
match the power generation supply. This paper presents a new
adaptive load-shedding scheme that provides emergency protection
against excess frequency decline, in cases when the Kosovo power
system might be disconnected from the regional transmission
network. The proposed load-shedding scheme uses the local
frequency rate information to adapt the load-shedding pattern to suit
the size and location of the occurring disturbance. The proposed
scheme is tested in a software simulation on a large scale PSS/E
model which represents nine power system areas of Southeast Europe
including the Kosovo power system.
Abstract: The growth and interconnection of power networks in many regions has invited complicated techniques for energy management services (EMS). State estimation techniques become a powerful tool in power system control centers, and that more information is required to achieve the objective of EMS. For the online state estimator, assuming the continuous time is equidistantly sampled with period Δt, processing events must be finished within this period. Advantage of Kalman Filtering (KF) algorithm in using system information to improve the estimation precision is utilized. Computational power is a major issue responsible for the achievement of the objective, i.e. estimators- solution at a small sampled period. This paper presents the optimum utilization of processors in a state estimator based on KF. The model used is presented using Petri net (PN) theory.
Abstract: Low frequency power oscillations may be triggered
by many events in the system. Most oscillations are damped by the
system, but undamped oscillations can lead to system collapse.
Oscillations develop as a result of rotor acceleration/deceleration
following a change in active power transfer from a generator. Like
the operations limits, the monitoring of power system oscillating
modes is a relevant aspect of power system operation and control.
Unprevented low-frequency power swings can be cause of cascading
outages that can rapidly extend effect on wide region. On this regard,
a Wide Area Monitoring, Protection and Control Systems
(WAMPCS) help in detecting such phenomena and assess power
system dynamics security. The monitoring of power system
electromechanical oscillations is very important in the frame of
modern power system management and control. In first part, this
paper compares the different technique for identification of power
system oscillations. Second part analyzes possible identification
some power system dynamics behaviors Using Wide Area
Monitoring Systems (WAMS) based on Phasor Measurement Units
(PMUs) and wavelet technique.
Abstract: Small signal stability causes small perturbations in the
generator that can cause instability in the power network. It is
generally known that small signal stability are directly related to the
generator and load properties. This paper examines the effects of
generator input variations on power system oscillations for a small
signal stability study. Eigenvaules and eigenvectors are used to
examine the stability of the power system. The dynamic power
system's mathematical model is constructed and thus calculated using
load flow and small signal stability toolbox on MATLAB. The power
system model is based on a 3-machine 9-bus system that was
modified to suit this study. In this paper, Participation Factors are a
means to gauge the effects of variation in generation with other
parameters on the network are also incorporated.
Abstract: The fault current levels through the electric devices
have a significant impact on failure probability. New fault current
results in exceeding the rated capacity of circuit breaker and switching
equipments and changes operation characteristic of overcurrent relay.
In order to solve these problems, SFCL (Superconducting Fault
Current Limiter) has rising as one of new alternatives so as to improve
these problems. A fault current reduction differs depending on
installed location. Therefore, a location of SFCL is very important.
Also, SFCL decreases the fault current, and it prevents surrounding
protective devices to be exposed to fault current, it then will bring a
change of reliability. In this paper, we propose method which
determines the optimal location when SFCL is installed in power
system. In addition, the reliability about the power system which
SFCL was installed is evaluated. The efficiency and effectiveness of
this method are also shown by numerical examples and the reliability
indices are evaluated in this study at each load points. These results
show a reliability change of a system when SFCL was installed.
Abstract: The condition of lightning surge causes the traveling waves and the temporary increase in voltage in the transmission line system. Lightning is the most harmful for destroying the transmission line and setting devices so it is necessary to study and analyze the temporary increase in voltage for designing and setting the surge arrester. This analysis describes the figure of the lightning wave in transmission line with 115 kV voltage level in Thailand by using ATP/EMTP program to create the model of the transmission line and lightning surge. Because of the limit of this program, it must be calculated for the geometry of the transmission line and surge parameter and calculation in the manual book for the closest value of the parameter. On the other hand, for the effects on surge protector when the lightning comes, the surge arrester model must be right and standardized as metropolitan electrical authority's standard. The candidate compared the real information to the result from calculation, also. The results of the analysis show that the temporary increase in voltage value will be rise to 326.59 kV at the line which is done by lightning when the surge arrester is not set in the system. On the other hand, the temporary increase in voltage value will be 182.83 kV at the line which is done by lightning when the surge arrester is set in the system and the period of the traveling wave is reduced, also. The distance for setting the surge arrester must be as near to the transformer as possible. Moreover, it is necessary to know the right distance for setting the surge arrester and the size of the surge arrester for preventing the temporary increase in voltage, effectively.
Abstract: This paper presents a reliability-based approach to select appropriate wind turbine types for a wind farm considering site-specific wind speed patterns. An actual wind farm in the northern region of Iran with the wind speed registration of one year is studied in this paper. An analytic approach based on total probability theorem is utilized in this paper to model the probabilistic behavior of both turbines- availability and wind speed. Well-known probabilistic reliability indices such as loss of load expectation (LOLE), expected energy not supplied (EENS) and incremental peak load carrying capability (IPLCC) for wind power integration in the Roy Billinton Test System (RBTS) are examined. The most appropriate turbine type achieving the highest reliability level is chosen for the studied wind farm.
Abstract: This paper proposes transient angle stability
agents to enhance power system stability. The proposed transient
angle stability agents divided into two strategy agents. The
first strategy agent is a prediction agent that will predict power
system instability. According to the prediction agent-s output,
the second strategy agent, which is a control agent, is automatically
calculating the amount of active power reduction that can
stabilize the system and initiating a control action. The control
action considered is turbine fast valving. The proposed strategies
are applied to a realistic power system, the IEEE 50-
generator system. Results show that the proposed technique can
be used on-line for power system instability prediction and control.
Abstract: Protective relays are components of a protection system
in a power system domain that provides decision making element for
correct protection and fault clearing operations. Failure of the
protection devices may reduce the integrity and reliability of the power
system protection that will impact the overall performance of the
power system. Hence it is imperative for power utilities to assess the
reliability of protective relays to assure it will perform its intended
function without failure. This paper will discuss the application of
reliability analysis using statistical method called Life Data Analysis
in Tenaga Nasional Berhad (TNB), a government linked power utility
company in Malaysia, namely Transmission Division, to assess and
evaluate the reliability of numerical overcurrent protective relays from
two different manufacturers.
Abstract: Optimal reactive power flow is an optimization problem
with one or more objective of minimizing the active power losses for
fixed generation schedule. The control variables are generator bus
voltages, transformer tap settings and reactive power output of the
compensating devices placed on different bus bars. Biogeography-
Based Optimization (BBO) technique has been applied to solve
different kinds of optimal reactive power flow problems subject
to operational constraints like power balance constraint, line flow
and bus voltages limits etc. BBO searches for the global optimum
mainly through two steps: Migration and Mutation. In the present
work, BBO has been applied to solve the optimal reactive power
flow problems on IEEE 30-bus and standard IEEE 57-bus power
systems for minimization of active power loss. The superiority of the
proposed method has been demonstrated. Considering the quality of
the solution obtained, the proposed method seems to be a promising
one for solving these problems.