Abstract: In this research, Response Surface Methodology (RSM) is used to investigate the effect of four controllable input variables namely: discharge current, pulse duration, pulse off time and applied voltage Surface Roughness (SR) of on Electrical Discharge Machined surface. To study the proposed second-order polynomial model for SR, a Central Composite Design (CCD) is used to estimation the model coefficients of the four input factors, which are alleged to influence the SR in Electrical Discharge Machining (EDM) process. Experiments were conducted on AISI D2 tool steel with copper electrode. The response is modeled using RSM on experimental data. The significant coefficients are obtained by performing Analysis of Variance (ANOVA) at 5% level of significance. It is found that discharge current, pulse duration, and pulse off time and few of their interactions have significant effect on the SR. The model sufficiency is very satisfactory as the Coefficient of Determination (R2) is found to be 91.7% and adjusted R2-statistic (R2 adj ) 89.6%.
Abstract: Nuclear matrix protein 22 (NMP22) is a FDA approved
biomarker for bladder cancer. The objective of this study is to develop
a simple NMP22 immumosensor (NMP22-IMS) for accurate
measurement of NMP22. The NMP22-IMS was constructed with
NMP22 antibody immobilized on screen-printed carbon electrodes.
The construction procedures and antibody immobilization are simple.
Results showed that the NMP22-IMS has an excellent (r2³0.95)
response range (20 – 100 ng/mL). In conclusion, a simple and reliable
NMP22-IMS was developed, capable of precisely determining urine
NMP22 level.
Abstract: We succeeded to produce a high performance and flexible graphene/Manganese dioxide (G/MnO2) electrode coated on flexible polyethylene terephthalate (PET) substrate. The graphene film is initially synthesized by drop-casting the graphene oxide (GO) solution on the PET substrate, followed by simultaneous reduction and patterning of the dried film using carbon dioxide (CO2) laser beam with power of 1.8 W. Potentiostatic Anodic Deposition method was used to deposit thin film of MnO2 with different loading mass 10 – 50 and 100 μg.cm-2 on the pre-prepared graphene film. The electrodes were fully characterized in terms of structure, morphology, and electrochemical performance. A maximum specific capacitance of 973 F.g-1 was attributed when depositing 50μg.cm-2 MnO2 on the laser reduced graphene oxide rGO (or G/50MnO2) and over 92% of its initial capacitance was retained after 1000 cycles. The good electrochemical performance and long-term cycling stability make our proposed approach a promising candidate in the supercapacitor applications.
Abstract: In this paper we introduce a novel method for
the characterization of synchronziation and coupling effects
in multivariate time series that can be used for the analysis
of EEG or ECoG signals recorded during epileptic seizures.
The method allows to visualize the spatio-temporal evolution
of synchronization and coupling effects that are characteristic
for epileptic seizures. Similar to other methods proposed for
this purpose our method is based on a regression analysis.
However, a more general definition of the regression together
with an effective channel selection procedure allows to use the
method even for time series that are highly correlated, which
is commonly the case in EEG/ECoG recordings with large
numbers of electrodes. The method was experimentally tested
on ECoG recordings of epileptic seizures from patients with
temporal lobe epilepsies. A comparision with the results from
a independent visual inspection by clinical experts showed
an excellent agreement with the patterns obtained with the
proposed method.
Abstract: Electrochemical-oxidation of Reactive Black-5 (RB- 5) was conducted for degradation using DSA type Ti/RuO2-SnO2- Sb2O5 electrode. In the study, for electro-oxidation, electrode was indigenously fabricated in laboratory using titanium as substrate. This substrate was coated using different metal oxides RuO2, Sb2O5 and SnO2 by thermal decomposition method. Laboratory scale batch reactor was used for degradation and decolorization studies at pH 2, 7 and 11. Current density (50mA/cm2) and distance between electrodes (8mm) were kept constant for all experiments. Under identical conditions, removal of color, COD and TOC at initial pH 2 was 99.40%, 55% and 37% respectively for initial concentration of 100 mg/L RB-5. Surface morphology and composition of the fabricated electrode coatings were characterized using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) respectively. Coating microstructure was analyzed by X-ray diffraction (XRD). Results of this study further revealed that almost 90% of oxidation occurred within 5-10 minutes.
Abstract: The aim of this study was to remove the two principal
noises which disturb the surface electromyography signal
(Diaphragm). These signals are the electrocardiogram ECG artefact
and the power line interference artefact. The algorithm proposed
focuses on a new Lean Mean Square (LMS) Widrow adaptive
structure. These structures require a reference signal that is correlated
with the noise contaminating the signal. The noise references are
then extracted : first with a noise reference mathematically
constructed using two different cosine functions; 50Hz (the
fundamental) function and 150Hz (the first harmonic) function for
the power line interference and second with a matching pursuit
technique combined to an LMS structure for the ECG artefact
estimation. The two removal procedures are attained without the use
of supplementary electrodes. These techniques of filtering are
validated on real records of surface diaphragm electromyography
signal. The performance of the proposed methods was compared with
already conducted research results.
Abstract: Applying corona wind as a novel technique can lead
to a great level of heat and mass transfer augmentation by using very
small amount of energy. Enhancement of forced flow evaporation
rate by applying electric field (corona wind) has been experimentally
evaluated in this study. Corona wind produced by a fine wire
electrode which is charged with positive high DC voltage impinges
to water surface and leads to evaporation enhancement by disturbing
the saturated air layer over water surface. The study was focused on
the effect of corona wind velocity, electrode spacing and air flow
velocity on the level of evaporation enhancement. Two sets of
experiments, i.e. with and without electric field, have been
conducted. Data obtained from the first experiment were used as
reference for evaluation of evaporation enhancement at the presence
of electric field. Applied voltages ranged from corona threshold
voltage to spark over voltage at 1 kV increments. The results showed
that corona wind has great enhancement effect on water evaporation
rate, but its effectiveness gradually diminishes by increasing air flow
velocity. Maximum enhancements were 7.3 and 3.6 for air velocities
of 0.125 and 1.75 m/s, respectively.
Abstract: This study investigates a voltage-controllable liquid crystals lens with a Fresnel zone electrode. When applying a proper voltage on the liquid crystal cell, a Fresnel-zone-distributed electric field is induced to direct liquid crystals aligned in a concentric structure. Owing to the concentrically aligned liquid crystals, a Fresnel lens is formed. We probe the Fresnel liquid crystal lens using a polarized incident beam with a wavelength of 632.8 nm, finding that the diffraction efficiency depends on the applying voltage. A remarkable diffraction efficiency of ~39.5 % is measured at the voltage of 0.9V. Additionally, a dual focus lens is fabricated by attaching a plane-convex lens to the Fresnel liquid crystals cell. The Fresnel LC lens and the dual focus lens may be applied for DVD/CD pick-up head, confocal microscopy system, or electrically-controlling optical systems.
Abstract: Measurement of the COD of a spent caustic solution involves firstly digestion of a test sample with dichromate solution and secondly measurement of dichromate remained by titration by ferrous ammonium sulfate [FAS] to an end point. In this paper we study by a potentiometric end point with Ag/AgCl reference electrode and gold rode electrode. The potentiometric end point is sharp and easily identified especially for the samples with high turbidity and color that other methods such as colorimetric in this type of sample do not result in high precision. Because interim of titration responds quickly to potential changes within the [Cr+6/Cr+3& Fe+2/Fe+3] solution producing stable readings that is lead to accurate COD measurement. Finally results are compared with data determined using colorimetric method for standard samples. It is shown that the potentiometric end point titration with gold rode electrode can be used with equal or better facility
Abstract: Carbon nanotubes (CNTs) with their high mechanical,
electrical, thermal and chemical properties are regarded as promising
materials for many different potential applications. Having unique
properties they can be used in a wide range of fields such as
electronic devices, electrodes, drug delivery systems, hydrogen
storage, textile etc. Catalytic chemical vapor deposition (CCVD) is a
common method for CNT production especially for mass production.
Catalysts impregnated on a suitable substrate are important for
production with chemical vapor deposition (CVD) method. Iron
catalyst and MgO substrate is one of most common catalyst-substrate
combination used for CNT. In this study, CNTs were produced by
CCVD of acetylene (C2H2) on magnesium oxide (MgO) powder
substrate impregnated by iron nitrate (Fe(NO3)3•9H2O) solution. The
CNT synthesis conditions were as follows: at synthesis temperatures
of 500 and 800°C multiwall and single wall CNTs were produced
respectively. Iron (Fe) catalysts were prepared by with Fe:MgO ratio
of 1:100, 5:100 and 10:100. The duration of syntheses were 30 and
60 minutes for all temperatures and catalyst percentages. The
synthesized materials were characterized by thermal gravimetric
analysis (TGA), transmission electron microscopy (TEM) and Raman
spectroscopy.
Abstract: The influence of axial magnetic field (B=0.48 T) on
the variation of ionization efficiency coefficient h and secondary
electron emission coefficient g with respect to reduced electric field
E/P is studied at a new range of plane-parallel electrode spacing (0<
d< 20 cm) and different nitrogen working pressure between 0.5-20
Pa. The axial magnetic field is produced from an inductive copper
coil of radius 5.6 cm. The experimental data of breakdown voltage is
adopted to estimate the mean Paschen curves at different working
features. The secondary electron emission coefficient is calculated
from the mean Paschen curve and used to determine the minimum
breakdown voltage. A reduction of discharge voltage of about 25% is
investigated by the applied of axial magnetic field. At high interelectrode
spacing, the effect of axial magnetic field becomes more
significant for the obtained values of h but it was less for the values
of g.
Abstract: In this paper we present a new multichannel high
voltage driver box to connect up to six MOEMS mirror devices to it that have resonant and also quasistatically driven actuating electrodes. It is possible to drive all resonant axes synchronously
while the amplitude of them can individually be controlled by separate microcontrollers that also operate the quasistatic axes.
Circuit simulations are compared with the measurements done on the
real system and also show the robust driving performance of a
MOEMS mirror.
Abstract: The biomarker for colorectal cancer (CRC) is CEACAM-6 antigen (C6AG). Therefore, this study aims to develop a novel, simple and low-cost CEACAM-6 antigen immumosensor (C6AG-IMS), based on electrical impedance measurement, for precise determination of C6AG. A low-cost screen-printed graphite electrode was constructed and used as the sensor, with CEACAM-6 antibody (C6AB) immobilized on it. The procedures of sensor fabrication and antibody immobilization are simple and low-cost. Measurement of the electrical impedance at a definite frequency ranges (0.43 – 1.26 MHz) showed that the C6AG-IMS has an excellent linear (r2>0.9) response range (8.125 – 65 pg/mL), covering the normal physiological and pathological ranges of blood C6AG levels. Also, the C6AG-IMS has excellent reliability and validity, with the intraclass correlation coefficient being 0.97. In conclusion, a novel, simple, low-cost and reliable C6AG-IMS was designed and developed, being able to accurately determine blood C6AG levels in the range of pathological and normal physiological regions. The C6AG-IMS can provide a point-of-care and immediate screening results to the user at home.
Abstract: This paper deals optimized model to investigate the
effects of peak current, pulse on time and pulse off time in EDM performance on material removal rate of titanium alloy utilizing copper tungsten as electrode and positive polarity of the electrode. The experiments are carried out on Ti6Al4V. Experiments were
conducted by varying the peak current, pulse on time and pulse off time. A mathematical model is developed to correlate the influences of these variables and material removal rate of workpiece. Design of
experiments (DOE) method and response surface methodology
(RSM) techniques are implemented. The validity test of the fit and adequacy of the proposed models has been carried out through
analysis of variance (ANOVA). The obtained results evidence that as
the material removal rate increases as peak current and pulse on time
increases. The effect of pulse off time on MRR changes with peak ampere. The optimum machining conditions in favor of material removal rate are verified and compared. The optimum machining
conditions in favor of material removal rate are estimated and verified with proposed optimized results. It is observed that the developed model is within the limits of the agreeable error (about
4%) when compared to experimental results. This result leads to desirable material removal rate and economical industrial machining to optimize the input parameters.
Abstract: This study numerically investigates the effects of Electrohydrodynamic on flow patterns and heat transfer enhancement within a cavity which is on the lower wall of channel. In this simulation, effects of using ground wire and ground plate on the flow patterns are compared. Moreover, the positions of electrode wire respecting with ground are tested in the range of angles θ = 0 - 180o. High electrical voltage exposes to air is 20 kV. Bulk mean velocity and temperature of inlet air are controlled at 0.1 m/s and 60 OC, respectively. The result shows when electric field is applied, swirling flow is appeared in the channel. In addition, swirling flow patterns in the main flow of using ground plate are widely spreader than that of using ground wire. Moreover, direction of swirling flow also affects the flow pattern and heat transfer in a cavity. These cause the using ground wire to give the maximum temperature and heat transfer higher than using ground plate. Furthermore, when the angle is at θ = 60o, high shear flow effect is obtained. This results show high strength of swirling flow and effective heat transfer enhancement.
Abstract: High Voltage (HV) transmission lines are widely
spread around residential places. They take all forms of shapes:
concrete, steel, and timber poles. Earth grid always form part of the
HV transmission structure, whereat soil resistivity value is one of the
main inputs when it comes to determining the earth grid
requirements. In this paper, the soil structure and its implication on
the electrode resistance of HV transmission poles will be explored. In
Addition, this paper will present simulation for various soil structures
using IEEE and Australian standards to verify the computation with
CDEGS software. Furthermore, the split factor behavior under
different soil resistivity structure will be presented using CDEGS
simulations.
Abstract: Electromyography (EMG) is the study of muscles function through analysis of electrical activity produced from muscles. This electrical activity which is displayed in the form of signal is the result of neuromuscular activation associated with muscle contraction. The most common techniques of EMG signal recording are by using surface and needle/wire electrode where the latter is usually used for interest in deep muscle. This paper will focus on surface electromyogram (SEMG) signal. During SEMG recording, several problems had to been countered such as noise, motion artifact and signal instability. Thus, various signal processing techniques had been implemented to produce a reliable signal for analysis. SEMG signal finds broad application particularly in biomedical field. It had been analyzed and studied for various interests such as neuromuscular disease, enhancement of muscular function and human-computer interface.
Abstract: In this study, a nickel film with nano-crystalline grains,
high hardness and smooth surface was electrodeposited using a post
supercritical carbon dioxide (CO2) mixed Watts electrolyte. Although
the hardness was not as high as its Sc-CO2 counterpart, the thin coating
contained significantly less number of nano-sized pinholes. By
measuring the escape concentration of the dissolved CO2 in post
Sc-CO2 mixed electrolyte with the elapsed time, it was believed that
the residue of dissolved CO2 bubbles should closely relate to the
improvement in hardness and surface roughness over its conventional
plating counterpart. Therefore, shortening the duration of
electroplating with the raise of current density up to 0.5 A/cm2 could
effectively retain more post Sc-CO2 mixing effect. This study not only
confirms the roles of dissolved CO2 bubbles in electrolyte but also
provides a potential process to overcome most issues associated with
the cost in building high-pressure chamber for large size products and
continuous plating using supercritical method.
Abstract: This research study the application of the immobilized
TiO2 layer and Cu-TiO2 layer on graphite substrate as a negative
electrode or anode for Li-ion battery. The titania layer was produced
through chemical bath deposition method, meanwhile Cu particles
were deposited electrochemically. A material can be used as an
electrode as it has capability to intercalates Li ions into its crystal
structure. The Li intercalation into TiO2/Graphite and Cu-
TiO2/Graphite were analyzed from the changes of its XRD pattern
after it was used as electrode during discharging process. The XRD
patterns were refined by Le Bail method in order to determine the
crystal structure of the prepared materials. A specific capacity and the
cycle ability measurement were carried out to study the performance
of the prepared materials as negative electrode of the Li-ion battery.
The specific capacity was measured during discharging process from
fully charged until the cut off voltage. A 300 was used as a load.
The result shows that the specific capacity of Li-ion battery with
TiO2/Graphite as negative electrode is 230.87 ± 1.70mAh.g-1 which is
higher than the specific capacity of Li-ion battery with pure graphite
as negative electrode, i.e 140.75 ±0.46mAh.g-1. Meanwhile
deposition of Cu onto TiO2 layer does not increase the specific
capacity, and the value even lower than the battery with
TiO2/Graphite as electrode. The cycle ability of the prepared battery
is only two cycles, due to the Li ribbon which was used as cathode
became fragile and easily broken.
Abstract: In this paper we present the modeling, design, and
experimental testing of a nerve cuff multi-electrode system for
diameter-selective vagus nerve stimulation.
The multi-electrode system contained ninety-nine platinum
electrodes embedded within a self-curling spiral silicone sheet. The
electrodes were organized in a matrix having nine parallel groups,
each containing eleven electrodes.
Preliminary testing of the nerve cuff was performed in an isolated
segment of a swinish left cervical vagus nerve. For selective vagus
nerve stimulation, precisely defined current quasitrapezoidal,
asymmetric and biphasic stimulating pulses were applied to
preselected locations along the left vagus segment via appointed
group of three electrodes within the cuff. Selective stimulation was
obtained by anodal block. However, these pulses may not be safe for
a long-term application because of a frequently used high imbalance
between the cathodic and anodic part of the stimulating pulse.
Preliminary results show that the cuff was capable of exciting A
and B-fibres, and, that for a certain range of parameters used in
stimulating pulses, the contribution of A-fibres to the CAP was
slightly reduced and the contribution of B-fibres was slightly larger.
Results also showed that measured CAPs are not greatly
influenced by the imbalance between a charge Qc injected in cathodic
and Qa in anodic phase of quasitrapezoidal, asymmetric and biphasic
pulses.