Abstract: Electromyography (EMG) is one of the important indicators during exercise, as it is closely related to the level of muscle activations. This work quantifies the muscle conditions of the lower limbs in a constant workload exercise. Surface EMG signals of the vastus laterals (VL), vastus medialis (VM), rectus femoris (RF), gastrocnemius medianus (GM), gastrocnemius lateral (GL) and Soleus (SOL) were recorded from fourteen healthy males. The EMG signals were segmented in two phases: activation segment (AS) and relaxation segment (RS). Period entropy (PE), peak count (PC), zero crossing (ZC), wave length (WL), mean power frequency (MPF), median frequency (MDF) and root mean square (RMS) are calculated to provide the quantitative information of the measured EMG segments. The outcomes reveal that the PE, PC, ZC and RMS have significantly changed (p
Abstract: Myoelectric control system is the fundamental
component of modern prostheses, which uses the myoelectric signals
from an individual’s muscles to control the prosthesis movements.
The surface electromyogram signal (sEMG) being noninvasive has
been used as an input to prostheses controllers for many years.
Recent technological advances has led to the development of
implantable myoelectric sensors which enable the internal
myoelectric signal (MES) to be used as input to these prostheses
controllers. The intramuscular measurement can provide focal
recordings from deep muscles of the forearm and independent signals
relatively free of crosstalk thus allowing for more independent
control sites. However, little work has been done to compare the two
inputs. In this paper we have compared the classification accuracy of
six pattern recognition based myoelectric controllers which use
surface myoelectric signals recorded using untargeted (symmetric)
surface electrode arrays to the same controllers with multichannel
intramuscular myolectric signals from targeted intramuscular
electrodes as inputs. There was no significant enhancement in the
classification accuracy as a result of using the intramuscular EMG
measurement technique when compared to the results acquired using
the surface EMG measurement technique. Impressive classification
accuracy (99%) could be achieved by optimally selecting only five
channels of surface EMG.
Abstract: This paper proposes a method of remotely controlling robots with arm gestures using surface electromyography (EMG) and accelerometer sensors attached to the operator’s wrists. The EMG and accelerometer sensors receive signals from the arm gestures of the operator and infer the corresponding movements to execute the command to control the robot. The movements of the robot include moving forward and backward and turning left and right. The accuracy is over 99% and movements can be controlled in real time.
Abstract: The aim of this study was to remove the two principal
noises which disturb the surface electromyography signal
(Diaphragm). These signals are the electrocardiogram ECG artefact
and the power line interference artefact. The algorithm proposed
focuses on a new Lean Mean Square (LMS) Widrow adaptive
structure. These structures require a reference signal that is correlated
with the noise contaminating the signal. The noise references are
then extracted : first with a noise reference mathematically
constructed using two different cosine functions; 50Hz (the
fundamental) function and 150Hz (the first harmonic) function for
the power line interference and second with a matching pursuit
technique combined to an LMS structure for the ECG artefact
estimation. The two removal procedures are attained without the use
of supplementary electrodes. These techniques of filtering are
validated on real records of surface diaphragm electromyography
signal. The performance of the proposed methods was compared with
already conducted research results.
Abstract: Electromyography (EMG) signal processing has been investigated remarkably regarding various applications such as in rehabilitation systems. Specifically, wavelet transform has served as a powerful technique to scrutinize EMG signals since wavelet transform is consistent with the nature of EMG as a non-stationary signal. In this paper, the efficiency of wavelet transform in surface EMG feature extraction is investigated from four levels of wavelet decomposition and a comparative study between different mother wavelets had been done. To recognize the best function and level of wavelet analysis, two evaluation criteria, scatter plot and RES index are recruited. Hereupon, four wavelet families, namely, Daubechies, Coiflets, Symlets and Biorthogonal are studied in wavelet decomposition stage. Consequently, the results show that only features from first and second level of wavelet decomposition yields good performance and some functions of various wavelet families can lead to an improvement in separability class of different hand movements.