Abstract: This paper presents an analytical approach for
evaluating distribution system reliability indices in the presence of
distributed generation. Modeling distributed generation and
evaluation of distribution system reliability indices using the
frequency duration technique. Using model implements and case
studies are discussed. Results showed that location of DG and its
effect in distribution reliability indices. In this respect, impact of DG
on distribution system is investigated using the IEEE Roy Billinton
test system (RBTS2) included feeder 1. Therefore, it will help to the
distribution system planners in the DG resource placement.
Abstract: The current study aims to highlight the loading
characteristics impact on the time evolution (focusing particularly on
long term effects) of the deformation of realized reinforced concrete
beams. Namely the tension stiffening code provisions (i.e. within
Eurocode 2) are reviewed with a clear intention to reassess their
operational value and predicting capacity. In what follows the
experimental programme adopted along with some preliminary
findings and numerical modeling attempts are presented. For a range of long slender reinforced concrete simply supported
beams (4200 mm) constant static sustained and repeated cyclic
loadings were applied mapping the time evolution of deformation.
All experiments were carried out at the Heavy Structures Lab of the
University of Leeds. During tests the mid-span deflection, creep
coefficient and shrinkage strains were monitored for duration of 90
days. The obtained results are set against the values predicted by
Eurocode 2 and the tools within an FE commercial package (i.e.
Midas FEA) to yield that existing knowledge and practise is at times
over-conservative.
Abstract: The application of cold Radio-Frequency (RF) plasma
in the conservation of cultural heritage became important in the last
decades due to the positive results obtained in decontamination
treatments. This paper presents an equipment especially designed for cold RF
plasma application on paper documents, developed within a research
project. The equipment consists in two modules: the first one is
designed for decontamination and cleaning treatments of any type of
paper supports, while the second one can be used for coating friable
papers with adequate polymers, for protection purposes. All these
operations are carried out in cold radio-frequency plasma, working in
gaseous nitrogen, at low pressure. In order to optimize the equipment parameters ancient paper
samples infested with microorganisms have been treated in nitrogen
plasma and the decontamination effects, as well as changes in surface
properties (color, pH) were assessed. The microbiological analysis
revealed complete decontamination at 6 minutes treatment duration;
only minor modifications of the surface pH were found and the
colorimetric analysis showed a slight yellowing of the support.
Abstract: Adequate analgesia following caesarean section
decreases morbidity, hastens ambulation, improves patient outcome
and facilitates care of the newborn. Intrathecal magnesium, an
NMDA antagonist, has been shown to prolong analgesia without
significant side effects in healthy parturients. The aim of this study
was to evaluate the onset and duration of sensory and motor block,
hemodynamic effect, postoperative analgesia, and adverse effects of
magnesium or fentanyl given intrathecally with hyperbaric 0.5%
bupivacaine in patients with mild preeclampsia undergoing caesarean
section. Sixty women with mild preeclampsia undergoing elective
caesarean section were included in a prospective, double blind,
controlled trial. Patients were randomly assigned to receive spinal
anesthesia with 2 mL 0.5% hyperbaric bupivacaine with 12.5 μg
fentanyl (group F) or 0.1 ml of 50% magnesium sulphate (50 mg)
(group M) with 0.15ml preservative free distilled water. Onset,
duration and recovery of sensory and motor block, time to maximum
sensory block, duration of spinal anaesthesia and postoperative
analgesic requirements were studied. Statistical comparison was
carried out using the Chi-square or Fisher’s exact tests and
Independent Student’s t-test where appropriate. The onset of both
sensory and motor block was slower in the magnesium group. The
duration of spinal anaesthesia (246 vs. 284) and motor block (186.3
vs. 210) were significantly longer in the magnesium group. Total
analgesic top up requirement was less in group M. Hemodynamic
parameters were similar in both the groups. Intrathecal magnesium
caused minimal side effects. Since Fentanyl and other opioid
congeners are not available throughout the country easily,
magnesium with its easy availability and less side effect profile can
be a cost effective alternative to fentanyl in managing pregnancy
induced hypertension (PIH) patients given along with Bupivacaine
intrathecally in caesarean section.
Abstract: In this article, a new method is proposed for the measuring of well-being inequality through a model composed of superimposing satisfaction waves. The displacement of households’ satisfactory state (i.e. satisfaction) is defined in a satisfaction string. The duration of the satisfactory state for a given period is measured in order to determine the relationship between utility and total satisfactory time, itself dependent on the density and tension of each satisfaction string. Thus, individual cardinal total satisfaction values are computed by way of a one-dimensional form for scalar sinusoidal (harmonic) moving wave function, using satisfaction waves with varying amplitudes and frequencies which allow us to measure wellbeing inequality. One advantage to using satisfaction waves is the ability to show that individual utility and consumption amounts would probably not commute; hence, it is impossible to measure or to know simultaneously the values of these observables from the dataset. Thus, we crystallize the problem by using a Heisenberg-type uncertainty resolution for self-adjoint economic operators. We propose to eliminate any estimation bias by correlating the standard deviations of selected economic operators; this is achieved by replacing the aforementioned observed uncertainties with households’ perceived uncertainties (i.e. corrected standard deviations) obtained through the logarithmic psychophysical law proposed by Weber and Fechner.
Abstract: The use of titanium fluoride and iron fluoride
(TiF3/FeF3) catalysts in combination with polutetrafluoroethylene
(PTFE) in plain zinc- dialkyldithiophosphate (ZDDP) oil is important
for the study of engine tribocomponents and is increasingly a strategy
to improve the formation of tribofilm and provide low friction and
excellent wear protection in reduced phosphorus plain ZDDP oil. The
influence of surface roughness and the concentration of
TiF3/FeF3/PTFE were investigated using bearing steel samples
dipped in lubricant solution at 100°C for two different heating time
durations. This paper addresses the effects of water drop contact
angle using different surface; finishes after treating them with
different lubricant combination. The calculated water drop contact
angles were analyzed using Design of Experiment software (DOE)
and it was determined that a 0.05 μm Ra surface roughness would
provide an excellent TiF3/FeF3/PTFE coating for antiwear resistance
as reflected in the Scanning electron microscopy (SEM) images and
the tribological testing under extreme pressure conditions. Both
friction and wear performance depend greatly on the PTFE/and
catalysts in plain ZDDP oil with 0.05 % phosphorous and on the
surface finish of bearing steel. The friction and wear reducing effects,
which was observed in the tribological tests, indicated a better micro
lubrication effect of the 0.05 μm Ra surface roughness treated at
100°C for 24 hours when compared to the 0.1 μm Ra surface
roughness with the same treatment.
Abstract: The purpose of this study is to determine the
relationship of anxiety level between male and female undergraduates
at a private university in Malaysia. Convenient sampling method used
in this study in which the students were selected based on the
grouping assigned by the faculty. There were 214 undergraduates
who registered the probability courses had participated in this study.
Mathematics Anxiety Rating Scale (MARS) was the instrument used
in study which used to determine students’ anxiety level towards
probability. Reliability and validity of instrument was done before the
major study was conducted. In the major study, students were given
briefing about the study conducted. Participation of this study was
voluntary. Students were given consent form to determine whether
they agree to participate in the study. Duration of two weeks was
given for students to complete the given online questionnaire. The
data collected will be analyzed using Statistical Package for the
Social Sciences (SPSS) to determine the level of anxiety. There were
three anxiety level, i.e., low, average and high. Students’ anxiety
level was determined based on their scores obtained compared with
the mean and standard deviation. If the scores obtained were below
mean and standard deviation, the anxiety level was low. If the scores
were at below and above the mean and between one standard
deviation, the anxiety level was average. If the scores were above the
mean and greater than one standard deviation, the anxiety level was
high. Results showed that both of genders were having average
anxiety level. Among low, average and high anxiety level, frequency
of males were found to be higher as compared to females. Hence, the
mean values obtained for males (M = 3.62) was higher than females
(M = 3.42). In order to be significant of anxiety level among the
gender, the p-value should be less than .05. The p-value obtained in
this study was .117. However, this value was greater than .05. Thus,
there was no significant difference of anxiety level among the gender.
In other words, there was no relationship of anxiety level with the
gender.
Abstract: Phonocardiography is important in appraisal of
congenital heart disease and pulmonary hypertension as it reflects the
duration of right ventricular systoles. The systolic murmur in patients
with intra-cardiac shunt decreases as pulmonary hypertension
develops and may eventually disappear completely as the pulmonary
pressure reaches systemic level. Phonocardiography and auscultation
are non-invasive, low-cost, and accurate methods to assess heart
disease. In this work an objective signal processing tool to extract
information from phonocardiography signal using Wavelet is
proposed to classify the murmur as normal or abnormal. Since the
feature vector is large, a Binary Particle Swarm Optimization (PSO)
with mutation for feature selection is proposed. The extracted
features improve the classification accuracy and were tested across
various classifiers including Naïve Bayes, kNN, C4.5, and SVM.
Abstract: The design of high pressure water jet based polishing
equipment and its fabrication conducted in this study is reported
herein, together with some preliminary test results for assessing its
applicability for HMA surface polishing. This study also provides
preliminary findings concerning the test variables, such as the
rotational speed, the water jet pressure, the abrasive agent used, and
the impact angel that were experimentally investigated in this study. The preliminary findings based on four trial tests (two on large
slab specimens and two on small size gyratory compacted
specimens), however, indicate that both friction and texture values
tend to increase with the polishing durations for two combinations of
pressure and rotation speed of the rotary deck. It seems that the more
polishing action the specimen is subjected to; the aggregate edges are
created such that the surface texture values are increased with the
accompanied increase in friction values. It may be of interest (but
which is outside the scope of this study) to investigate if the similar
trend exist for HMA prepared with aggregate source that is sand and
gravel.
Abstract: The flow duration curve (FDC) is an informative
method that represents the flow regime’s properties for a river basin.
Therefore, the FDC is widely used for water resource projects such as
hydropower, water supply, irrigation and water quality management.
The primary purpose of this study is to obtain synthetic daily flow
duration curves for Çoruh Basin, Turkey. For this aim, we firstly
developed univariate auto-regressive moving average (ARMA)
models for daily flows of 9 stations located in Çoruh basin and then
these models were used to generate 100 synthetic flow series each
having same size as historical series. Secondly, flow duration curves
of each synthetic series were drawn and the flow values exceeded 10,
50 and 95% of the time and 95% confidence limit of these flows were
calculated. As a result, flood, mean and low flows potential of Çoruh
basin will comprehensively be represented.
Abstract: Surf is an increasingly popular sport and its performance evaluation is often qualitative. This work aims at using a smartphone to collect and analyze the GPS and inertial sensors data in order to obtain quantitative metrics of the surfing performance. Two approaches are compared for detection of wave rides, computing the number of waves rode in a surfing session, the starting time of each wave and its duration. The first approach is based on computing the velocity from the Global Positioning System (GPS) signal and finding the velocity thresholds that allow identifying the start and end of each wave ride. The second approach adds information from the Inertial Measurement Unit (IMU) of the smartphone, to the velocity thresholds obtained from the GPS unit, to determine the start and end of each wave ride. The two methods were evaluated using GPS and IMU data from two surfing sessions and validated with similar metrics extracted from video data collected from the beach. The second method, combining GPS and IMU data, was found to be more accurate in determining the number of waves, start time and duration. This paper shows that it is feasible to use smartphones for quantification of performance metrics during surfing. In particular, detection of the waves rode and their duration can be accurately determined using the smartphone GPS and IMU.
Abstract: Aluminium matrix composites with alumina
reinforcements give superior mechanical & physical properties. Their
applications in several fields like automobile, aerospace, defense,
sports, electronics, bio-medical and other industrial purposes are
becoming essential for the last several decades. In the present work,
fabrication of hybrid composite was done by Stir casting technique
using Al 6061 as a matrix with alumina and silicon carbide (SiC) as
reinforcement materials. The weight percentage of alumina is varied
from 2 to 4% and the silicon carbide weight percentage is maintained
constant at 2%. Hardness and wear tests are performed in the as cast
and heat treated conditions. Age hardening treatment was performed
on the specimen with solutionizing at 550°C, aging at two
temperatures (150 and 200°C) for different time durations. Hardness
distribution curves are drawn and peak hardness values are recorded.
Hardness increase was very sensitive with respect to the decrease in
aging temperature. There was an improvement in wear resistance of
the peak aged material when aged at lower temperature. Also
increase in weight percent of alumina, increases wear resistance at
lower temperature but opposite behavior was seen when aged at
higher temperature.
Abstract: The addition of lime as Ca(OH)2 to sewage sludge to
destroy pathogens (Escherichia coli), was evaluated also in relation
to heavy metal bioavailability.
The obtained results show that the use of calcium hydroxide at the
dose of 3% effectively destroyed pathogens ensuring the stability at
high pH values over long period and the duration of the sewage
sludge stabilization. In general, lime addition decreased the total
extractability of heavy metals indicating a reduced bioavailability of
these elements. This is particularly important for a safe utilization in
agricultural soils to reduce the possible transfer of heavy metals to
the food chain.
Abstract: In order to produce lead free piezoceramics with
optimum piezoelectric and dielectric properties, KNN modified with
Li+ (as an A site dopant) and Sb5+ (as a B site dopant)
(K0.49Na0.49Li0.02) (Nb0.96Sb0.04) O3 (referred as KNLNS in this paper)
have been synthesized using solid state reaction method and
conventional sintering technique. The ceramics were sintered in the
narrow range of 1050°C-1090°C for 2-3 h to get precise information
about sintering parameters. Detailed study of dependence of
microstructural, dielectric and piezoelectric properties on sintering
conditions was then carried out. The study suggests that the volatility
of the highly hygroscopic KNN ceramics is not only sensitive to
sintering temperatures but also to sintering durations. By merely
reducing the sintering duration for a given sintering temperature we
saw an increase in the density of the samples which was supported by
the increase in dielectric constants of the ceramics. And since density
directly or indirectly affects almost all the associated properties, other
dielectric and piezoelectric properties were also enhanced as we
approached towards the most suitable sintering temperature and
duration combination. The detailed results are reported in this paper.
Abstract: Present study is carried out on six lane divided urban
arterial road in Patna and Pune city of India. Both the road having
distinct differences in terms of the vehicle composition and the road
side parking. Arterial road in Patan city has 33% of non-motorized
mode, whereas Pune arterial road dominated by 65% of Two wheeler.
Also road side parking is observed in Patna city. The field studies
using videography techniques are carried out for traffic data
collection. Data are extracted for one minute duration for vehicle
composition, speed variation and flow rate on selected arterial road of
the two cities. Speed flow relationship is developed and capacity is
determine. Equivalency factor in terms of dynamic car unit is
determine to represent the vehicle is single unit. The variation in the
capacity due to side friction, presence of non motorized traffic and
effective utilization of lane width is compared at concluding remarks.
Abstract: Non contact evaluation of the thickness of paint
coatings can be attempted by different destructive and nondestructive
methods such as cross-section microscopy, gravimetric mass
measurement, magnetic gauges, Eddy current, ultrasound or
terahertz. Infrared thermography is a nondestructive and non-invasive
method that can be envisaged as a useful tool to measure the surface
thickness variations by analyzing the temperature response. In this
paper, the thermal quadrupole method for two layered samples heated
up with a pulsed excitation is firstly used. By analyzing the thermal
responses as a function of thermal properties and thicknesses of both
layers, optimal parameters for the excitation source can be identified.
Simulations show that a pulsed excitation with duration of ten
milliseconds allows obtaining a substrate-independent thermal
response. Based on this result, an experimental setup consisting of a
near-infrared laser diode and an Infrared camera was next used to
evaluate the variation of paint coating thickness between 60 μm and
130 μm on two samples. Results show that the parameters extracted
for thermal images are correlated with the estimated thicknesses by
the Eddy current methods. The laser pulsed thermography is thus an
interesting alternative nondestructive method that can be moreover
used for nonconductive substrates.
Abstract: The main goal of this article is to describe the online
flood monitoring and prediction system Floreon+ primarily developed
for the Moravian-Silesian region in the Czech Republic and the basic
process it uses for running automatic rainfall-runoff and
hydrodynamic simulations along with their calibration and
uncertainty modeling. It takes a long time to execute such process
sequentially, which is not acceptable in the online scenario, so the use
of a high performance computing environment is proposed for all
parts of the process to shorten their duration. Finally, a case study on
the Ostravice River catchment is presented that shows actual
durations and their gain from the parallel implementation.
Abstract: In this study, the Compressive strength of concretes
made with Ground Granulated Blast furnace Slag (GGBS),
Pulverised Fuel Ash (PFA), Rice Husk Ash (RHA) and Waste Glass
Powder (WGP) after they were exposed 7800C (exposure duration of
around 60 minutes) and then allowed to cool down gradually in the
furnace for about 280 minutes at water binder ratio of 0.50 was
investigated. GGBS, PFA, RHA and WGP were used to replace up to
20% Portland cement in the control concrete. Test for the
determination of workability, compressive strength and tensile
splitting strength of the concretes were carried out and the results
were compared with control concrete. The test results showed that the
compressive strength decreased by an average of around 30% after
the concretes were exposed to the heating and cooling scenario.
Abstract: Electroencephalogram (EEG) is a noninvasive
technique that registers signals originating from the firing of neurons
in the brain. The Emotiv EEG Neuroheadset is a consumer product
comprised of 14 EEG channels and was used to record the reactions
of the neurons within the brain to two forms of stimuli in 10
participants. These stimuli consisted of auditory and visual formats
that provided directions of ‘right’ or ‘left.’ Participants were
instructed to raise their right or left arm in accordance with the
instruction given. A scenario in OpenViBE was generated to both
stimulate the participants while recording their data. In OpenViBE,
the Graz Motor BCI Stimulator algorithm was configured to govern
the duration and number of visual stimuli. Utilizing EEGLAB under
the cross platform MATLAB®, the electrodes most stimulated during
the study were defined. Data outputs from EEGLAB were analyzed
using IBM SPSS Statistics® Version 20. This aided in determining
the electrodes to use in the development of a brain-machine interface
(BMI) using real-time EEG signals from the Emotiv EEG
Neuroheadset. Signal processing and feature extraction were
accomplished via the Simulink® signal processing toolbox. An
Arduino™ Duemilanove microcontroller was used to link the Emotiv
EEG Neuroheadset and the right and left Mecha TE™ Hands.
Abstract: In this research paper were investigated the main
regularities of a radical bromination reaction of decalin. There had
been studied the temperature effect, durations of reaction, frequency
rate of process, a ratio of initial components, type and number of the
initiator on decalin bromination degree.
There were specified optimum conditions of synthesis of a
perbromodecalin by the method of a decalin bromination. There are
developed the technological flowchart of receiving a
perbromodecalin and the mass balance of process on the first and the
subsequent loadings of components.
The results of research of antibacterial and antifungal activity of
synthesized bromoderivatives have been represented.