Abstract: For traditional painting materials, the artisan used to combine the pigments with different binders to create colors. As time goes by, the materials used for painting evolved from natural to chemical materials. The vast variety of ingredients used in chemical materials has complicated restoration work; it makes conservation work more difficult. Conservation work also becomes harder when the materials cannot be easily identified; therefore, it is essential that we take a more scientific approach to assist in conservation work. Paintings materials are high molecular weight polymer, and their analysis is very complicated as well other contamination such as smoke and dirt can also interfere with the analysis of the material. The current methods of composition analysis of painting materials include Fourier transform infrared spectroscopy (FT-IR), mass spectrometer, Raman spectroscopy, X-ray diffraction spectroscopy (XRD), each of which has its own limitation. In this study, FT-IR was used to analyze the components of the paint coating. We have taken the most commonly seen materials as samples and deteriorated it. The aged information was then used for the database to exam the temple painting materials. By observing the FT-IR changes over time, we can tell all of the painting materials will be deteriorated by the UV light, but only the speed of its degradation had some difference. From the deterioration experiment, the acrylic resin resists better than the others. After collecting the painting materials aging information on FT-IR, we performed some test on the paintings on the temples. It was found that most of the artisan used tune-oil for painting materials, and some other paintings used chemical materials. This method is now working successfully on identifying the painting materials. However, the method is destructive and high cost. In the future, we will work on the how to know the painting materials more efficiently.
Abstract: In the past decade, the use of digital image correlation
(DIC) techniques has increased significantly in the area of
experimental mechanics, especially for materials behavior
characterization. This non-contact tool enables full field displacement
and strain measurements over a complete region of interest. The DIC
algorithm requires a random contrast pattern on the surface of the
specimen in order to perform properly. To create this pattern, the
specimen is usually first coated using a white matt paint. Next, a
black random speckle pattern is applied using any suitable method. If
the applied paint coating is too thick, its top surface may not be able
to exactly follow the deformation of the specimen, and consequently,
the strain measurement might be underestimated. In the present
article, a study of the influence of the paint thickness on the strain
underestimation is performed for different strain levels. The results
are then compared to typical paint coating thicknesses applied by
experienced DIC users. A slight strain underestimation was observed
for paint coatings thicker than about 30μm. On the other hand, this
value was found to be uncommonly high compared to coating
thicknesses applied by DIC users.
Abstract: Non contact evaluation of the thickness of paint
coatings can be attempted by different destructive and nondestructive
methods such as cross-section microscopy, gravimetric mass
measurement, magnetic gauges, Eddy current, ultrasound or
terahertz. Infrared thermography is a nondestructive and non-invasive
method that can be envisaged as a useful tool to measure the surface
thickness variations by analyzing the temperature response. In this
paper, the thermal quadrupole method for two layered samples heated
up with a pulsed excitation is firstly used. By analyzing the thermal
responses as a function of thermal properties and thicknesses of both
layers, optimal parameters for the excitation source can be identified.
Simulations show that a pulsed excitation with duration of ten
milliseconds allows obtaining a substrate-independent thermal
response. Based on this result, an experimental setup consisting of a
near-infrared laser diode and an Infrared camera was next used to
evaluate the variation of paint coating thickness between 60 μm and
130 μm on two samples. Results show that the parameters extracted
for thermal images are correlated with the estimated thicknesses by
the Eddy current methods. The laser pulsed thermography is thus an
interesting alternative nondestructive method that can be moreover
used for nonconductive substrates.