Abstract: This paper presents the generation of bipolar square
wave pulses with characteristics that are suitable for liquid food
sterilization using a Cascaded H-bridge Multilevel Inverter (CHMI).
Bipolar square waves pulses have been reported as stable for a
longer time during the sterilization process with minimum heat
emission and increased efficiency. The CHMI allows the system to
produce bipolar square wave pulses and yielding high output voltage
without using a transformer while fulfilling the pulse requirements
for effective liquid food sterilization. This in turn can reduce power
consumption and cost of the overall liquid food sterilization system.
The simulation results have shown that pulses with peak output
voltage of 2.4 kV, pulse width of between 1 2s and 1 ms at
frequencies of 50 Hz and 100 Hz can be generated by a 7-level
CHMI. Results from the experimental set-up based on a 5-level
CHMI has indicated the potential of the proposed circuit in
producing bipolar square wave output pulses with peak values that
depends on the DC source level supplied to the CHMI modules,
pulse width of between 12.5 2s and 1 ms at frequencies of 50 Hz
and 100 Hz.
Abstract: Optimization and control of reactive power
distribution in the power systems leads to the better operation of the
reactive power resources. Reactive power control reduces
considerably the power losses and effective loads and improves the
power factor of the power systems. Another important reason of the
reactive power control is improving the voltage profile of the power
system. In this paper, voltage and reactive power control using
Neural Network techniques have been applied to the 33 shines-
Tehran Electric Company. In this suggested ANN, the voltages of PQ
shines have been considered as the input of the ANN. Also, the
generators voltages, tap transformers and shunt compensators have
been considered as the output of ANN. Results of this techniques
have been compared with the Linear Programming. Minimization of
the transmission line power losses has been considered as the
objective function of the linear programming technique. The
comparison of the results of the ANN technique with the LP shows
that the ANN technique improves the precision and reduces the
computation time. ANN technique also has a simple structure and
this causes to use the operator experience.
Abstract: In this paper, the transformers over-load problem of Shiraz substation in Fars Regional Electric Company (FREC) is investigated for a period of three years plan. So the suggestions for using phase shifting transformer (PST) and unified power flow controller (UPFC) in order to solve this problem are examined in details and finally, some economical and practical designs will be given in order to solve the related problems. Practical consideration and using the basic and fundamental concept of powers in transmission lines in order to find the economical design are the main advantages of this research. The simulation results of the integrated overall system with different designs compare them base on economical and practical aspects to solve the over-load and loss-reduction.
Abstract: This paper describes interconnection between
technical and economical making decision. The reason of this dealing
could be different: poor technical condition, change of substation
(electrical network) regime, power transformer owner budget deficit
and increasing of tariff on electricity. Establishing of recommended
practice as well as to give general advice and guidance in economical
sector, testing, diagnostic power transformers to establish its
conditions, identify problems and provide potential remedies.
Abstract: Bentonitic material from South Aswan, Egypt was evaluated in terms of mineral-ogy and chemical composition as bleaching clay in refining of transformer oil before and after acid activation and thermal treatment followed by acid leaching using HCl and H2SO4 for different contact times. Structural modification and refining power of bento-nite were investigated during modification by means of X-ray diffraction and infrared spectroscopy. The results revealed that the activated bentonite could be used for refining of transformer oil. The oil parameters such as; dielectric strength, viscosity and flash point had been improved. The dielectric breakdown strength of used oil increased from 29 kV for used oil treated with unactivated bentonite to 74 kV after treatment with activated bentonite. Kinematic Viscosity changed from 19 to 11 mm2 /s after treatment with activated bentonite. However, flash point achieved 149 ºC.
Abstract: This paper compares the recent transformerless ACDC
power converter architectures and provides an assessment of
each. A prototype of one of the transformerless AC-DC converter
architecture is also presented depicting the feasibility of a small form
factor, power supply design. In this paper component selection
guidelines to achieve high efficiency AC-DC power conversion are
also discussed.
Abstract: In this paper, a thermal model of cast- resin dry type
transformer is proposed. The proposed thermal model is solved by
finite element technique to get the temperature at any location of the
transformer. The basic modes of heat transfer such as conduction;
convection and radiation are used to get the steady state temperature
distribution of the transformer. The predicted temperatures are
compared with experimental results reported in this paper and it is
found a good agreement between them. The effects of various
parameters such as width of air duct, ambient temperature and
emissivity of the outer surface were also studied.
Abstract: The winding hot-spot temperature is one of the most
critical parameters that affect the useful life of the power
transformers. The winding hot-spot temperature can be calculated as
function of the top-oil temperature that can estimated by using the
ambient temperature and transformer loading measured data. This
paper proposes the estimation of the top-oil temperature by using a
method based on Least Squares Support Vector Machines approach.
The estimated top-oil temperature is compared with measured data of
a power transformer in operation. The results are also compared with
methods based on the IEEE Standard C57.91-1995/2000 and
Artificial Neural Networks. It is shown that the Least Squares
Support Vector Machines approach presents better performance than
the methods based in the IEEE Standard C57.91-1995/2000 and
artificial neural networks.
Abstract: Improving the reactive power and voltage profile of a
distribution substation is investigated in this paper. The purpose is to
properly determination of the shunt capacitors on/off status and
suitable tap changer (TC) position of a substation transformer. In
addition, the limitation of secondary bus voltage, the maximum
allowable number of switching operation in a day for on load tap
changer and on/off status of capacitors are taken into account. To
achieve these goals, an artificial neural network (ANN) is designed to
provide preliminary scheduling. Input of ANN is active and reactive
powers of transformer and its primary and secondary bus voltages.
The output of ANN is capacitors on/off status and TC position. The
preliminary schedule is further refined by fuzzy dynamic
programming in order to reach the final schedule. The operation of
proposed method in Q/V improving is compared with the results
obtained by operator operation in a distribution substation.
Abstract: Bond graph models of an electrical transformer including
the nonlinear saturation are presented. The transformer
using electrical and magnetic circuits are modelled. These models
determine the relation between self and mutual inductances, and
the leakage and magnetizing inductances of power transformers
with two windings using the properties of a bond graph. The
equivalence between electrical and magnetic variables is given.
The modelling and analysis using this methodology to three phase
power transformers can be extended.
Abstract: Ferroresonance is an electrical phenomenon in
nonlinear character, which frequently occurs in power system due to
transmission line faults and single or more-phase switching on the
lines as well as usage of the saturable transformers. In this study, the
ferroresonance phenomena are investigated under the modeling of the
West Anatolian Electric Power Network of 380 kV in Turkey. The
ferroresonance event is observed as a result of removing the loads at
the end of the lines. In this sense, two different cases are considered.
At first, the switching is applied at 2nd second and the ferroresonance
affects are observed between 2nd and 4th seconds in the voltage
variations of the phase-R. Hence the ferroresonance and nonferroresonance
parts of the overall data are compared with each
others using the Fourier transform techniques to show the
ferroresonance affects.
Abstract: The experimental and theoretical results of a ZVS
(Zero Voltage Switching) isolated flyback DC-DC converter using
multilayered coreless PCB step down 2:1 transformer are presented.
The performance characteristics of the transformer are shown which
are useful for the parameters extraction. The measured energy
efficiency of the transformer is found to be more than 94% with the
sinusoidal input voltage excitation. The designed flyback converter
has been tested successfully upto the output power level of 10W,
with a switching frequency in the range of 2.7MHz-4.3MHz. The
input voltage of the converter is varied from 25V-40V DC.
Frequency modulation technique is employed by maintaining
constant off time to regulate the output voltage of the converter. The
energy efficiency of the isolated flyback converter circuit under ZVS
condition in the MHz frequency region is found to be approximately
in the range of 72-84%. This paper gives the comparative results in
terms of the energy efficiency of the hard switched and soft switched
flyback converter in the MHz frequency region.
Abstract: The most common cause of power transformer failures
is mechanical defect brought about by excessive vibration, which is
formed by the combination of multiples of a frequency of 120 Hz. In
this paper, the types of mechanical exciting forces applied to the
power transformer were classified, and the mechanical damage
mechanism of the power transformer was identified using the
vibration transfer route to the machine or structure. The general
effects of 120 Hz-vibration on the enclosure, bushing, Buchholz
relay, pressure release valve and tap changer of the transformer were
also examined.
Abstract: One of the problems in fault diagnosis of transformer
based on dissolved gas, is lack of matching the result of fault
diagnosis of different standards with the real world. In this paper, the
result of the different standards is analyzed using fuzzy and the result
is compared with the empirical test. The comparison between the
suggested method and existing methods indicate the capability of the
suggested method in on-line fault diagnosis of the transformers. In
addition, in some cases the existing standards are not able to
diagnose the fault. In theses cases, the presented method has the
potential of diagnosing the fault. The information of three
transformers is used to the show the capability of the suggested
method in diagnosing the fault. The results validate the capability of
the presented method in fault diagnosis of the transformer.
Abstract: Electricity market activities and a growing demand for electricity have led to heavily stressed power systems. This requires operation of the networks closer to their stability limits. Power system operation is affected by stability related problems, leading to unpredictable system behavior. Voltage stability refers to the ability of a power system to sustain appropriate voltage levels through large and small disturbances. Steady-state voltage stability is concerned with limits on the existence of steady-state operating points for the network. FACTS devices can be utilized to increase the transmission capacity, the stability margin and dynamic behavior or serve to ensure improved power quality. Their main capabilities are reactive power compensation, voltage control and power flow control. Among the FACTS controllers, Static Var Compensator (SVC) provides fast acting dynamic reactive compensation for voltage support during contingency events. In this paper, voltage stability assessment with appropriate representations of tap-changer transformers and SVC is investigated. Integrating both of these devices is the main topic of this paper. Effect of the presence of tap-changing transformers on static VAR compensator controller parameters and ratings necessary to stabilize load voltages at certain values are highlighted. The interrelation between transformer off nominal tap ratios and the SVC controller gains and droop slopes and the SVC rating are found. P-V curves are constructed to calculate loadability margins.
Abstract: In this paper, half bridge DC-DC converters with
transformer isolation presented in the literature are analyzed for highcurrent
and low-voltage applications under the same operation
conditions, and compared in terms of losses and efficiency. The
conventional and improved half-bridge DC-DC converters are
simulated, and current and voltage waveforms are obtained for input
voltage Vdc=500V, output current IO=450A, output voltage VO=38V
and switching frequency fS=20kHz. IGBTs are used as power
semiconductor switches. The power losses of the semiconductor
devices are calculated from current and voltage waveforms. From
simulation results, it is seen that the capacitor switched half bridge
converter has the best efficiency value, and can be preferred at high
power and high frequency applications.
Abstract: Power systems and transformer are intrinsic apparatus, therefore its reliability and safe operation is important to determine their operation conditions, and the industry uses quality control tests in the insulation design of oil filled transformers. Hence the service period effect on AC dielectric strength is significant. The effect of aging on transformer oil physical, chemical and electrical properties was studied using the international testing methods for the evaluation of transformer oil quality. The study was carried out on six transformers operate in the field and for monitoring periods over twenty years. The properties which are strongly time dependent were specified and those which have a great impact on the transformer oil acidity, breakdown voltage and dissolved gas analysis were defined. Several tests on the transformers oil were studied to know the time of purifying or changing it, moreover prediction of the characteristics of it under different operation conditions.
Abstract: This paper presents an experimental investigation of
transformer dielectric response and solid insulation water content.
The dielectric response was carried out on the base of Hybrid
Frequency Dielectric Spectroscopy and Polarization Current
measurements method (FDS &PC). The calculation of the water
content in paper is based on the water content in oil and the obtained
equilibrium curves. A reference measurements were performed at
equilibrium conditions for water content in oil and paper of
transformer at different stable temperatures (25, 50, 60 and 70°C) to
prepare references to evaluate the insulation behavior at the not
equilibrium conditions. Some measurements performed at the
different simulated normal working modes of transformer operation
at the same temperature where the equilibrium conditions. The
obtained results show that when transformer temperature is mach
more than the its ambient temperature, the transformer temperature
decreases immediately after disconnecting the transformer from the
network and this temperature reduction influences the transformer
insulation condition in the measuring process. In addition to the oil
temperature at the near places to the sensors, the temperature
uniformity in transformer which can be changed by a big change in
the load of transformer before the measuring time will influence the
result. The investigations have shown that the extremely influence of
the time between disconnecting the transformer and beginning the
measurements on the results. And the online monitoring for water
content in paper measurements, on the basis of the oil water content
on line monitoring and the obtained equilibrium curves. The
measurements where performed continuously and for about 50 days
without any disconnection in the prepared the adiabatic room.
Abstract: This paper presents a pulse doubling technique in a 12-pulse ac-dc converter which supplies direct torque controlled motor drives (DTCIMD-s) in order to have better power quality conditions at the point of common coupling. The proposed technique increases the number of rectification pulses without significant changes in the installations and yields in harmonic reduction in both ac and dc sides. The 12-pulse rectified output voltage is accomplished via two paralleled six-pulse ac-dc converters each of them consisting of three-phase diode bridge rectifier. An autotransformer is designed to supply the rectifiers. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. Independent operation of paralleled diode-bridge rectifiers, i.e. dc-ripple re-injection methodology, requires a Zero Sequence Blocking Transformer (ZSBT). Finally, a tapped interphase reactor is connected at the output of ZSBT to double the pulse numbers of output voltage up to 24 pulses. The aforementioned structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6- pulse, 12-pulse, and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 5% for the proposed topology at various loads.
Abstract: This study reports the preparation of soft magnetic
ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213
mm and, with a thickness of approximately 22 μm ± 2 μm. The microstructure and magnetic properties of the ribbons were
characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material
properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic
measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide
ribbon, the magnetic responses are not uniformly distributed. To
understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a
ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.