Abstract: This paper investigates the impact on operating time delay and relay maloperation when 1st,2nd and 3rd order analog antialiasing filters are used in numerical distance protection. RC filter with cut-off frequency 90 Hz is used. Simulations are carried out for different SIR (Source to line Impedance Ratio), load, fault type and fault conditions using SIMULINK, where the voltage and current signals are fed online to the developed numerical distance relay model. Matlab is used for plotting the impedance trajectory. Investigation results shows that, about 75 % of the simulated cases, numerical distance relay operating time is not increased even-though there is a time delay when higher order filters are used. Relay maloperation (selectivity) also reduces (increases) when higher order filters are used in numerical distance protection.
Abstract: This paper deals with design of walking beam pendel
axle suspension system. This axles and suspension systems are
mainly required for transportation of heavy duty and Over Dimension
Consignment (ODC) cargo, which is exceeding legal limit in terms of
length, width and height. Presently, in Indian transportation industry,
ODC movement growth rate has increased in transportation of bridge
sections (pre-cast beams), transformers, heavy machineries, boilers,
gas turbines, windmill blades etc. However, current Indian standard
road transport vehicles are facing lot of service and maintenance
issues due to non availability of suitable axle and suspension to carry
the ODC cargoes. This in turn will lead to increased number of road
accidents, bridge collapse and delayed deliveries, which finally result
in higher operating cost. Understanding these requirements, this work
was carried out. These axles and suspensions are designed for
optimum self – weight with maximum payload carrying capacity with
better road stability.
Abstract: Dissolved gas analysis has been accepted as a sensitive, informative and reliable technique for incipient faults detection in power transformers and is widely used. In the last few years this method, which has been recommended by IEEE Power & Energy society, has been applied for fault detection in load tap changers. Regarding the critical role of load tap changers in electrical network and essential of catastrophic failures prevention, it is necessary to choose "condition based preventative maintenance strategy" which leads to reduction in costs, the number of unnecessary visits as well as the probability of interruptions and also increment in equipment reliability. In current work, considering the condition based preventative maintenance strategy, condition assessment of an Elin tap changer was carried out using dissolved gas analysis.
Abstract: This work proposes a set of actions to assist redesign
procedure in existing products of Electric and Electronic Equipment
(EEE). The aim is to improve their environmental behavior after their
withdrawal in the End-of-Life (EOL) phase. In the beginning data
collection takes place. Then follows selection and implementation of
the optimal EOL Treatment Strategy (EOL_TS) and its results-
evaluation concerning the environment. In parallel, product design
characteristics that can be altered are selected based on their
significance for the environment in the EOL stage. All results from
the previous stages are combined and possible redesign actions are
formulated for further examination and afterwards configuration in
the design stage. The applied method to perform these tasks is Lean
Thinking (LT). At the end, results concerning the application of the
proposed method on a distribution transformer are presented.
Abstract: A bond graph model of an electrical transformer
including the nonlinear saturation is presented. A nonlinear observer for the transformer based on multivariable circle
criterion in the physical domain is proposed. In order to show the saturation and hysteresis effects on the electrical transformer,
simulation results are obtained. Finally, the paper describes that convergence of the estimates to the true states is achieved.
Abstract: In this treatise we will study the capability of static
compensator for reactive power to stabilize sheen voltage with motor
loading on power networks system. We also explain the structure and main function of STATCOM and the method to control it using STATCOM transformer current to simultaneously predict after
telling about the necessity of FACTS tools to compensate in power networks. Then we study topology and controlling system to stabilize
voltage during start of inductive motor. The outcome of stimulat by MATLAB software supports presented controlling idea and
system in the treatise.
Abstract: Power transformers are among the most important and
expensive equipments in the electric power systems. Consequently
the transformer protection is an essential part of the system
protection. This paper presents a new method for locating
transformer winding faults such as turn-to-turn, turn-to-core, turn-totransformer
body, turn-to-earth, and high voltage winding to low
voltage winding. In this study the current and voltage signals of input
and output terminals of the transformer are measured, which the
Fourier transform of measured signals and harmonic analysis
determine the fault's location.
Abstract: In this paper, we present a cost-effective wireless
distributed load shedding system for non-emergency scenarios. In
power transformer locations where SCADA system cannot be used,
the proposed solution provides a reasonable alternative that combines
the use of microcontrollers and existing GSM infrastructure to send
early warning SMS messages to users advising them to proactively
reduce their power consumption before system capacity is reached
and systematic power shutdown takes place.
A novel communication protocol and message set have been
devised to handle the messaging between the transformer sites, where
the microcontrollers are located and where the measurements take
place, and the central processing site where the database server is
hosted. Moreover, the system sends warning messages to the endusers
mobile devices that are used as communication terminals. The
system has been implemented and tested via different experimental
results.
Abstract: This paper presents the development of a wavelet
based algorithm, for distinguishing between magnetizing inrush
currents and power system fault currents, which is quite adequate,
reliable, fast and computationally efficient tool. The proposed
technique consists of a preprocessing unit based on discrete wavelet
transform (DWT) in combination with an artificial neural network
(ANN) for detecting and classifying fault currents. The DWT acts as
an extractor of distinctive features in the input signals at the relay
location. This information is then fed into an ANN for classifying
fault and magnetizing inrush conditions. A 220/55/55 V, 50Hz
laboratory transformer connected to a 380 V power system were
simulated using ATP-EMTP. The DWT was implemented by using
Matlab and Coiflet mother wavelet was used to analyze primary
currents and generate training data. The simulated results presented
clearly show that the proposed technique can accurately discriminate
between magnetizing inrush and fault currents in transformer
protection.
Abstract: This paper deals with the effect of a power transformer’s vector group on the basic voltage sag characteristics during unbalanced faults at a meshed or radial power network. Specifically, the propagation of voltage sags through a power transformer is studied with advanced short-circuit analysis. A smart method to incorporate this effect on analytical mathematical expressions is proposed. Based on this methodology, the positive effect of transformers of certain vector groups on the mitigation of the expected number of voltage sags per year (sag frequency) at the terminals of critical industrial customers can be estimated.
Abstract: This paper presents a novel three-phase utility
frequency to high frequency soft switching power conversion circuit
with dual mode pulse width modulation and pulse density modulation
for high power induction heating applications as melting of steel and
non ferrous metals, annealing of metals, surface hardening of steel
and cast iron work pieces and hot water producers, steamers and
super heated steamers. This high frequency power conversion circuit
can operate from three-phase systems to produce high current for
high power induction heating applications under the principles of
ZVS and it can regulate its ac output power from the rated value to a
low power level. A dual mode modulation control scheme based on
high frequency PWM in synchronization with the utility frequency
positive and negative half cycles for the proposed high frequency
conversion circuit and utility frequency pulse density modulation is
produced to extend its soft switching operating range for wide ac
output power regulation. A dual packs heat exchanger assembly is
designed to be used in consumer and industrial fluid pipeline systems
and it is proved to be suitable for the hot water, steam and super
heated steam producers. Experiment and simulation results are given
in this paper to verify the operation principles of the proposed ac
conversion circuit and to evaluate its power regulation and
conversion efficiency. Also, the paper presents a mutual coupling
model of the induction heating load instead of equivalent transformer
circuit model.
Abstract: Harmonic pollution and low power factor in power
systems caused by power converters have been of great concern. To
overcome these problems several converter topologies using
advanced semiconductor devices and control schemes have been
proposed. This investigation is to identify a low cost, small size,
efficient and reliable ac to dc converter to meet the input performance
index of UPS. The performance of single phase and three phase ac to
dc converter along with various control techniques are studied and
compared. The half bridge converter topology with linear current
control is identified as most suitable. It is simple, energy efficient
because of single switch power loss and transformer-less operation of
UPS. The results are validated practically using a prototype built
using IGBT and analog controller. The performance for both single
and three-phase system is verified. Digital implementation of closed
loop control achieves higher reliability. Its cost largely depends on
chosen bit precision. The minimal bit precision for optimum
converter performance is identified as 16-bit with fixed-point
operation. From the investigation and practical implementation it is
concluded that half bridge ac – dc converter along with digital linear
controller meets the performance index of UPS for single and three
phase systems.
Abstract: In this paper a three dimensional thermal model of a
power toroidal transformer is proposed for both steady-state or
transient conditions. The influence of electric current and ambient
temperature on the temperature distribution, has been investigated.
To validate the three dimensional thermal model, some experimental
tests have been done. There is a good correlation between
experimental and simulation results.
Abstract: Knowledge about the magnetic quantities in a magnetic circuit is always of great interest. On the one hand, this information is needed for the simulation of a transformer. On the other hand, parameter studies are more reliable, if the magnetic quantities are derived from a well established model. One possibility to model the 3-phase transformer is by using a magnetic equivalent circuit (MEC). Though this is a well known system, it is often not an easy task to set up such a model for a large number of lumped elements which additionally includes the nonlinear characteristic of the magnetic material. Here we show the setup of a solver for a MEC and the results of the calculation in comparison to measurements taken. The equations of the MEC are based on a rearranged system of the nodal analysis. Thus it is possible to achieve a minimum number of equations, and a clear and simple structure. Hence, it is uncomplicated in its handling and it supports the iteration process. Additional helpful tasks are implemented within the solver to enhance the performance. The electric circuit is described by an electric equivalent circuit (EEC). Our results for the 3-phase transformer demonstrate the computational efficiency of the solver, and show the benefit of the application of a MEC.
Abstract: Diagnostic goal of transformers in service is to detect the winding or the core in fault. Transformers are valuable equipment which makes a major contribution to the supply security of a power system. Consequently, it is of great importance to minimize the frequency and duration of unwanted outages of power transformers. So, Frequency Response Analysis (FRA) is found to be a useful tool for reliable detection of incipient mechanical fault in a transformer, by finding winding or core defects. The authors propose as first part of this article, the coupled circuits method, because, it gives most possible exhaustive modelling of transformers. And as second part of this work, the application of FRA in low frequency in order to improve and simplify the response reading. This study can be useful as a base data for the other transformers of the same categories intended for distribution grid.
Abstract: Personnel protection devices are cardinal in safety hazard applications. They are widely used in home, office and in industry environments to reduce the risk of lethal shock to human being and equipment safety. This paper briefly reviews various personnel protection devices also describes the basic working principle of conventional ground fault circuit interrupter (GFCI) or ground fault isolator (GFI), its disadvantages and ways to overcome the disadvantages with solid-state relay (SSR) based GFI with ultrafast response up on fault implemented in printed circuit board. This solid state GFI comprises discrete MOSFET based alternating current (AC) switches, linear optical amplifier, photovoltaic isolator and sense resistor. In conventional GFI, current transformer is employed as a sensing element to detect the difference in current flow between live and neutral conductor. If there is no fault in equipment powered through GFI, due to insulation failure of internal wires and windings of motors, both live and neutral currents will be equal in magnitude and opposite in phase.
Abstract: Insulation used in transformer is mostly oil pressboard insulation. Insulation failure is one of the major causes of catastrophic failure of transformers. It is established that partial discharges (PD) cause insulation degradation and premature failure of insulation. Online monitoring of PDs can reduce the risk of catastrophic failure of transformers. There are different techniques of partial discharge measurement like, electrical, optical, acoustic, opto-acoustic and ultra high frequency (UHF). Being non invasive and non interference prone, acoustic emission technique is advantageous for online PD measurement. Acoustic detection of p.d. is based on the retrieval and analysis of mechanical or pressure signals produced by partial discharges. Partial discharges are classified according to the origin of discharges. Their effects on insulation deterioration are different for different types. This paper reports experimental results and analysis for classification of partial discharges using acoustic emission signal of laboratory simulated partial discharges in oil pressboard insulation system using three different electrode systems. Acoustic emission signal produced by PD are detected by sensors mounted on the experimental tank surface, stored on an oscilloscope and fed to computer for further analysis. The measured AE signals are analyzed using discrete wavelet transform analysis and wavelet packet analysis. Energy distribution in different frequency bands of discrete wavelet decomposed signal and wavelet packet decomposed signal is calculated. These analyses show a distinct feature useful for PD classification. Wavelet packet analysis can sort out any misclassification arising out of DWT in most cases.
Abstract: A new topology of unified power quality conditioner
(UPQC) is proposed for different power quality (PQ) improvement in
a three-phase four-wire (3P-4W) distribution system. For neutral
current mitigation, a star-hexagon transformer is connected in shunt
near the load along with three-leg voltage source inverters (VSIs)
based UPQC. For the mitigation of source neutral current, the uses of
passive elements are advantageous over the active compensation due
to ruggedness and less complexity of control. In addition to this, by
connecting a star-hexagon transformer for neutral current mitigation
the over all rating of the UPQC is reduced. The performance of the
proposed topology of 3P-4W UPQC is evaluated for power-factor
correction, load balancing, neutral current mitigation and mitigation
of voltage and currents harmonics. A simple control algorithm based
on Unit Vector Template (UVT) technique is used as a control
strategy of UPQC for mitigation of different PQ problems. In this
control scheme, the current/voltage control is applied over the
fundamental supply currents/voltages instead of fast changing APFs
currents/voltages, thereby reducing the computational delay.
Moreover, no extra control is required for neutral source current
compensation; hence the numbers of current sensors are reduced. The
performance of the proposed topology of UPQC is analyzed through
simulations results using MATLAB software with its Simulink and
Power System Block set toolboxes.
Abstract: The gases generated in oil filled transformers can be
used for qualitative determination of incipient faults. The Dissolved
Gas Analysis has been widely used by utilities throughout the world
as the primarily diagnostic tool for transformer maintenance. In this
paper, various Artificial Intelligence Techniques that have been used
by the researchers in the past have been reviewed, some conclusions
have been drawn and a sequential hybrid system has been proposed.
The synergy of ANN and FIS can be a good solution for reliable
results for predicting faults because one should not rely on a single
technology when dealing with real–life applications.
Abstract: Voltage stability has become an important issue to many power systems around the world due to the weak systems and long line on power system networks. In this paper, MATLAB load flow program is applied to obtain the weak points in the system combined with finding the voltage stability limit. The maximum permissible loading of a system, within the voltage stability limit, is usually determined. The methods for varying tap ratio (using tap changing transformer) and applying different values of shunt capacitor injection to improve the voltage stability within the limit are also provided.