Abstract: The paper analyzes the large power transformer unit regimes, indicating the criteria for the management of the voltage operating conditions, as well as the change in the operating conditions with the load connected to the secondary winding of the transformer unit. Further, the paper presents the software application for the evaluation of the transformer unit operation under different conditions. The software application was developed by means of virtual instrumentation.
Abstract: In this paper, multilayered coreless printed circuit
board (PCB) step-down power transformers for DC-DC converter
applications have been designed, manufactured and evaluated. A set
of two different circular spiral step-down transformers were
fabricated in the four layered PCB. These transformers have been
modelled with the assistance of high frequency equivalent circuit and
characterized with both sinusoidal and square wave excitation. This
paper provides the comparative results of these two different
transformers in terms of their resistances, self, leakage, mutual
inductances, coupling coefficient and also their energy efficiencies.
The operating regions for optimal performance of these transformers
for power transfer applications are determined. These transformers
were tested for the output power levels of about 30 Watts within the
input voltage range of 12-50 Vrms. The energy efficiency for these
step down transformers is observed to be in the range of 90%-97% in
MHz frequency region.
Abstract: Condition monitoring of electrical power equipment
has attracted considerable attention for many years. The aim of this
paper is to use Labview with Fuzzy Logic controller to build a
simulation system to diagnose transformer faults and monitor its
condition. The front panel of the system was designed using
LabVIEW to enable computer to act as customer-designed
instrument. The dissolved gas-in-oil analysis (DGA) method was
used as technique for oil type transformer diagnosis; meanwhile
terminal voltages and currents analysis method was used for dry type
transformer. Fuzzy Logic was used as expert system that assesses all
information keyed in at the front panel to diagnose and predict the
condition of the transformer. The outcome of the Fuzzy Logic
interpretation will be displayed at front panel of LabVIEW to show
the user the conditions of the transformer at any time.
Abstract: Temperature rise in a transformer depends on variety
of parameters such as ambient temperature, output current and type
of the core. Considering these parameters, temperature rise estimation
is still complicated procedure. In this paper, we present a new model
based on simple electrical equivalent circuit. This method avoids the
complication associated to accurate estimation and is in very good
agreement with practice.
Abstract: With Power system movement toward restructuring along with factors such as life environment pollution, problems of transmission expansion and with advancement in construction technology of small generation units, it is expected that small units like wind turbines, fuel cells, photovoltaic, ... that most of the time connect to the distribution networks play a very essential role in electric power industry. With increase in developing usage of small generation units, management of distribution networks should be reviewed. The target of this paper is to present a new method for optimal management of active and reactive power in distribution networks with regard to costs pertaining to various types of dispersed generations, capacitors and cost of electric energy achieved from network. In other words, in this method it-s endeavored to select optimal sources of active and reactive power generation and controlling equipments such as dispersed generations, capacitors, under load tapchanger transformers and substations in a way that firstly costs in relation to them are minimized and secondly technical and physical constraints are regarded. Because the optimal management of distribution networks is an optimization problem with continuous and discrete variables, the new evolutionary method based on Ant Colony Algorithm has been applied. The simulation results of the method tested on two cases containing 23 and 34 buses exist and will be shown at later sections.
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: Non-Destructive evaluation of in-service power
transformer condition is necessary for avoiding catastrophic failures.
Dissolved Gas Analysis (DGA) is one of the important methods.
Traditional, statistical and intelligent DGA approaches have been
adopted for accurate classification of incipient fault sources.
Unfortunately, there are not often enough faulty patterns required for
sufficient training of intelligent systems. By bootstrapping the
shortcoming is expected to be alleviated and algorithms with better
classification success rates to be obtained. In this paper the
performance of an artificial neural network, K-Nearest Neighbour
and support vector machine methods using bootstrapped data are
detailed and shown that while the success rate of the ANN algorithms
improves remarkably, the outcome of the others do not benefit so
much from the provided enlarged data space. For assessment, two
databases are employed: IEC TC10 and a dataset collected from
reported data in papers. High average test success rate well exhibits
the remarkable outcome.
Abstract: Since large power transformers are the most
expensive and strategically important components of any power
generator and transmission system, their reliability is crucially
important for the energy system operation. Also, Circuit breakers are
very important elements in the power transmission line so monitoring
the events gives a knowledgebase to determine time to the next
maintenance. This paper deals with the introduction of the
comparative method of the state estimation of transformers and
Circuit breakers using continuous monitoring of voltage, current.
This paper gives details a new method based on wavelet to apparatus
insulation monitoring. In this paper to insulation monitoring of
transformer, a new method based on wavelet transformation and
neutral point analysis is proposed. Using the EMTP tools, fault in
transformer winding and the detailed transformer winding model
were simulated. The current of neutral point of winding was analyzed
by wavelet transformation. It is shown that the neutral current of the
transformer winding has useful information about fault in insulation
of the transformer.
Abstract: Model Predictive Control (MPC) is an established control
technique in a wide range of process industries. The reason for
this success is its ability to handle multivariable systems and systems
having input, output or state constraints. Neverthless comparing to
PID controller, the implementation of the MPC in miniaturized
devices like Field Programmable Gate Arrays (FPGA) and microcontrollers
has historically been very small scale due to its complexity in
implementation and its computation time requirement. At the same
time, such embedded technologies have become an enabler for future
manufacturing enterprisers as well as a transformer of organizations
and markets. In this work, we take advantage of these recent advances
in this area in the deployment of one of the most studied and applied
control technique in the industrial engineering. In this paper, we
propose an efficient firmware for the implementation of constrained
MPC in the performed STM32 microcontroller using interior point
method. Indeed, performances study shows good execution speed
and low computational burden. These results encourage to develop
predictive control algorithms to be programmed in industrial standard
processes. The PID anti windup controller was also implemented in
the STM32 in order to make a performance comparison with the
MPC. The main features of the proposed constrained MPC framework
are illustrated through two examples.
Abstract: An enhanced particle swarm optimization algorithm
(PSO) is presented in this work to solve the non-convex OPF
problem that has both discrete and continuous optimization variables.
The objective functions considered are the conventional quadratic
function and the augmented quadratic function. The latter model
presents non-differentiable and non-convex regions that challenge
most gradient-based optimization algorithms. The optimization
variables to be optimized are the generator real power outputs and
voltage magnitudes, discrete transformer tap settings, and discrete
reactive power injections due to capacitor banks. The set of equality
constraints taken into account are the power flow equations while the
inequality ones are the limits of the real and reactive power of the
generators, voltage magnitude at each bus, transformer tap settings,
and capacitor banks reactive power injections. The proposed
algorithm combines PSO with Newton-Raphson algorithm to
minimize the fuel cost function. The IEEE 30-bus system with six
generating units is used to test the proposed algorithm. Several cases
were investigated to test and validate the consistency of detecting
optimal or near optimal solution for each objective. Results are
compared to solutions obtained using sequential quadratic
programming and Genetic Algorithms.
Abstract: Happening of Ferroresonance phenomenon is one of the reasons of consuming and ruining transformers, so recognition of Ferroresonance phenomenon has a special importance. A novel method for classification of Ferroresonance presented in this paper. Using this method Ferroresonance can be discriminate from other transients such as capacitor switching, load switching, transformer switching. Wavelet transform is used for decomposition of signals and Competitive Neural Network used for classification. Ferroresonance data and other transients was obtained by simulation using EMTP program. Using Daubechies wavelet transform signals has been decomposed till six levels. The energy of six detailed signals that obtained by wavelet transform are used for training and trailing Competitive Neural Network. Results show that the proposed procedure is efficient in identifying Ferroresonance from other events.
Abstract: Piezoelectric transformers are electronic devices made
from piezoelectric materials. The piezoelectric transformers as the
name implied are used for changing voltage signals from one level to another. Electrical energy carried with signals is transferred by means of mechanical vibration. Characterizing in both electrical and
mechanical properties leads to extensively use and efficiency enhancement of piezoelectric transformers in various applications. In
this paper, study and analysis of electrical and mechanical properties of multi-layer piezoelectric transformers in forms of potential and
displacement distribution throughout the volume, respectively. This
paper proposes a set of quasi-static mathematical model of electromechanical
coupling for piezoelectric transformer by using a set of
partial differential equations. Computer-based simulation utilizing the three-dimensional finite element method (3-D FEM) is exploited
as a tool for visualizing potentials and displacements distribution
within the multi-layer piezoelectric transformer. This simulation was
conducted by varying a number of layers. In this paper 3, 5 and 7 of
the circular ring type were used. The computer simulation based on
the use of the FEM has been developed in MATLAB programming environment.
Abstract: Short circuit currents plays a vital role in influencing the design and operation of equipment and power system and could not be avoided despite careful planning and design, good maintenance and thorough operation of the system. This paper discusses the short circuit analysis conducted in KSO briefly comprising of its significances, methods and results. A result sample of the analysis based on a single transformer is detailed in this paper. Furthermore, the results of the analysis and its significances were also discussed and commented.
Abstract: Voltage flicker is a disturbance in electrical power
systems. The reason for this disturbance is mainly the large nonlinear
loads such as electric arc furnaces. Synchronous static
compensator (STATCOM) is considered as a proper technique to
mitigate the voltage flicker. Application of more suitable and precise
power electronic converter leads to a more precise performance of the
compensator. In this paper a three-level 12-pulse voltage source
inverter (VSI) with a 12-terminal transformer connected to the ac
system is studied and the obtained results are compared with the
performance of a STATCOM using a simple two-level VSI and an
optimal and more precise performance of the proposed scheme is
achieved.
Abstract: Optimal reactive power flow is an optimization problem
with one or more objective of minimizing the active power losses for
fixed generation schedule. The control variables are generator bus
voltages, transformer tap settings and reactive power output of the
compensating devices placed on different bus bars. Biogeography-
Based Optimization (BBO) technique has been applied to solve
different kinds of optimal reactive power flow problems subject
to operational constraints like power balance constraint, line flow
and bus voltages limits etc. BBO searches for the global optimum
mainly through two steps: Migration and Mutation. In the present
work, BBO has been applied to solve the optimal reactive power
flow problems on IEEE 30-bus and standard IEEE 57-bus power
systems for minimization of active power loss. The superiority of the
proposed method has been demonstrated. Considering the quality of
the solution obtained, the proposed method seems to be a promising
one for solving these problems.
Abstract: This study reports the preparation of soft magnetic ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213 mm and, with a thickness of approximately 22 μm 2 μm. The microstructure and magnetic properties of the ribbons were characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide ribbon, the magnetic responses are not uniformly distributed. To understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.
Abstract: This paper deals with a novel approach of power
transformers diagnostics. This approach identifies the exact location
and the range of a fault in the transformer and helps to reduce
operation costs related to handling of the faulty transformer, its
disassembly and repair. The advantage of the approach is a
possibility to simulate healthy transformer and also all faults, which
can occur in transformer during its operation without its
disassembling, which is very expensive in practice. The approach is
based on creating frequency dependent impedance of the transformer
by sweep frequency response analysis measurements and by 3D FE
parametrical modeling of the fault in the transformer. The parameters
of the 3D FE model are the position and the range of the axial short
circuit. Then, by comparing the frequency dependent impedances of
the parametrical models with the measured ones, the location and the
range of the fault is identified. The approach was tested on a real
transformer and showed high coincidence between the real fault and
the simulated one.
Abstract: This paper provides the design steps of a robust Linear
Matrix Inequality (LMI) based iterative multivariable PID controller
whose duty is to drive a sample power system that comprises a
synchronous generator connected to a large network via a step-up
transformer and a transmission line. The generator is equipped with
two control-loops, namely, the speed/power (governor) and voltage
(exciter). Both loops are lumped in one where the error in the
terminal voltage and output active power represent the controller
inputs and the generator-exciter voltage and governor-valve position
represent its outputs. Multivariable PID is considered here because of
its wide use in the industry, simple structure and easy
implementation. It is also preferred in plants of higher order that
cannot be reduced to lower ones. To improve its robustness to
variation in the controlled variables, H∞-norm of the system transfer
function is used. To show the effectiveness of the controller, divers
tests, namely, step/tracking in the controlled variables, and variation
in plant parameters, are applied. A comparative study between the
proposed controller and a robust H∞ LMI-based output feedback is
given by its robustness to disturbance rejection. From the simulation
results, the iterative multivariable PID shows superiority.
Abstract: The scope of this paper is to describe a real electrical
installation of renewable energy using photovoltaic cells. The
displayed power grid connected network was established in 2007 at
area of Northern Greece. The photovoltaic park is composed of 6120
photovoltaic cells able to deliver a total power of 1.101.600 Wp. For
the transformation of DC voltage to AC voltage have been used 25
stand alone three phases inverters and for the connection at the
medium voltage network of Greek Power Authority have been
installed two oil immersed transformer of 630 kVA each one. Due to
the wide space area of installation a specific external lightning
protection system has been designed. Additionally, due to the
sensitive electronics of the control and protection systems of park,
surge protection, equipotent bonding and shielding were also of
major importance.
Abstract: The power transformer is the most expensive, indispensable and arguably the most important equipment item in a power system Insulation failure in transformers can cause long term interruption to supply and loss of revenue and the condition assessment of the insulation is thus an important maintenance procedure. Oil-impregnated transformer insulation consists of mainly organic materials including mineral oil and cellulose-base paper and pressboard. The operating life of cellulose-based insulation, as with most organic insulation, depends heavily on its operating temperature rise above ambient. This paper reports results of a laboratory-based experimental investigation of partial discharge (PD) activity at high temperature in oil-impregnated insulation. The experiments reported here are part an on-going programme aimed at investigating the way in which insulation deterioration can be monitored and quantified by use of partial discharge diagnostics. Partial discharge patterns were recorded and analysed during increasing and decreasing phases of the temperature. The effect of ageing of the insulation on the PD patterns in oil and oil-impregnated insulation are also considered.