Abstract: The Canadian Nuclear Power Plants (NPPs) use some portions of NUREG/CR-6850 in carrying out Fire Probabilistic Risk Assessment (PRA). An assessment for the applicability of NUREG/CR-6850 to CANDU reactors was performed and a CANDU Fire PRA was introduced. There are 19 operating CANDU reactors in Canada at five sites (Bruce A, Bruce B, Darlington, Pickering and Point Lepreau). A fire load density survey was done for all Fire Safe Shutdown Analysis (FSSA) fire zones in all CANDU sites in Canada. National Fire Protection Association (NFPA) Standard 557 proposes that a fire load survey must be conducted by either the weighing method or the inventory method or a combination of both. The combination method results in the most accurate values for fire loads. An updated CANDU Fire PRA model is demonstrated in this paper that includes the fuel survey in all Canadian CANDU stations. A qualitative screening step for the CANDU fire PRA is illustrated in this paper to include any fire events that can damage any part of the emergency power supply in addition to FSSA cables.
Abstract: Invention of transistor is the foundation of electronics industry. Metal Oxide Semiconductor Field Effect Transistor (MOSFET) has been the key for the development of nanoelectronics technology. In the first part of this manuscript, we present a new generation of MOSFET transistors based on SOI (Silicon-On-Insulator) technology. It is a partially depleted Silicon-On-Insulator (PD SOI MOSFET) transistor simulated by using SILVACO software. This work was completed by the presentation of some results concerning the influence of parameters variation (channel length L and gate oxide thickness Tox) on our PDSOI n-MOSFET structure on its drain current and kink effect.
Abstract: Railways in India remain primary mode of transport
having one of the largest networks in the world and catering to
billions of transits yearly. Catastrophic economic damage and loss
to life is encountered over the past few decades due to fire to
locomotives. Study of fire dynamics and fire propagation plays an
important role in evacuation planning and reducing losses. Simulation
based study of propagation of fire and soot inside an air conditioned
coach of Indian locomotive is done in this paper. Finite difference
based solver, Fire Dynamic Simulator (FDS) version 6 has been
used for analysis. A single air conditioned 3 tier coupe closed to
ambient surroundings by glass windows having occupancy for 8
people is the basic unit of the domain. A system of three such
coupes combined is taken to be fundamental unit for the entire
study to resemble effect to an entire coach. Analysis of flame and
soot contours and concentrations is done corresponding to variations
in heat release rate per unit volume (HRRPUA) of fire source,
variations in conditioned air velocity being circulated inside coupes
by vents and an alternate fire initiation and propagation mechanism
via ducts. Quantitative results of fractional area in top and front
view of the three coupes under fire and smoke are obtained using
MATLAB (IMT). Present simulations and its findings will be useful
for organizations like Commission of Railway Safety and others in
designing and implementing safety and evacuation measures.
Abstract: Propagation of fire through a non-air conditioned
railway compartment is studied by virtue of numerical simulations.
Simultaneous computational fire dynamics equations, such as
Navier-Stokes, lumped species continuity, overall mass and energy
conservation, and heat transfer are solved using finite volume based
(for radiation) and finite difference based (for all other equations)
solver, Fire Dynamics Simulator (FDS). A single coupe with an eight
berth occupancy is used to establish the numerical model, followed
by the selection of a three coupe system as the fundamental unit
of the locomotive compartment. Heat Release Rate Per Unit Area
(HRRPUA) of the initial fire is varied to consider a wide range of
compartmental fires. Parameters, such as air inlet velocity relative
to the locomotive at the windows, the level of interaction with the
ambiance and closure of middle berth are studied through a wide
range of numerical simulations. Almost all the loss of lives and
properties due to fire breakout can be attributed to the direct or
indirect exposure to flames or to the inhalation of toxic gases and
resultant suffocation due to smoke and soot. Therefore, the temporal
stature of fire and smoke are reported for each of the considered
cases which can be used in the present or extended form to develop
guidelines to be followed in case of a fire breakout.
Abstract: As the number of fire accidents is gradually raising, many studies have been reported on evacuation. Previous studies have mostly focused on evaluating the safety of evacuation and the risk of fire in particular buildings. However, studies on effects of various parameters on evacuation have not been nearly done. Therefore, this paper aims at observing evacuation time under the effect of fire initiated location. In this study, evacuation simulations are performed on a 5-floor building located in Seoul, South Korea using the commercial program, Fire Dynamics Simulator with Evacuation (FDS+EVAC). Only the fourth and fifth floors are modeled with an assumption that fire starts in a room located on the fourth floor. The parameter for evacuation simulations is location of fire initiation to observe the evacuation time and safety. Results show that the location of fire initiation is closer to exit, the more time is taken to evacuate. The case having the nearest location of fire initiation to exit has the lowest ratio of successful occupants to the total occupants. In addition, for safety evaluation, the evacuation time calculated from computer simulation model is compared with the tolerable evacuation time according to code in Japan. As a result, all cases are completed within the tolerable evacuation time. This study allows predicting evacuation time under various conditions of fire and can be used to evaluate evacuation appropriateness and fire safety of building.
Abstract: Columns have traditionally been constructed of
reinforced concrete or structural steel. Much attention was allocated
to estimate the axial capacity of the traditional column sections to the
detriment of other forms of construction. Other forms of column
construction such as Concrete Filled Double Skin Tubes received
little research attention, and almost no attention when subjected to
eccentric loading. This paper investigates the axial capacity of
columns when subjected to eccentric loading. The experimental axial
capacities are compared to other established theoretical formulae on
concentric loading to determine a possible relationship. The study
found a good correlation between the reduction in axial capacity for
different column lengths and hollow section ratios.
Abstract: In this paper, the behavior of different types of DST columns has been studied under bending load. Briefly, composite columns consist of an internal carbon steel tube and an external stainless steel wall that the between the walls are filled with concrete. Composite columns are expected to combine the advantages of all three materials and have the advantage of high flexural stiffness of CFDST columns. In this research, ABAQUS software is used for finite element analysis then the results of ultimate strength of the composite sections are illustrated.
Abstract: The objective of this work is to use the Fire Dynamics Simulator (FDS) to investigate the behavior of a kerosene small-scale fire. FDS is a Computational Fluid Dynamics (CFD) tool developed specifically for fire applications. Throughout its development, FDS is used for the resolution of practical problems in fire protection engineering. At the same time FDS is used to study fundamental fire dynamics and combustion. Predictions are based on Large Eddy Simulation (LES) with a Smagorinsky turbulence model. LES directly computes the large-scale eddies and the sub-grid scale dissipative processes are modeled. This technique is the default turbulence model which was used in this study. The validation of the numerical prediction is done using a direct comparison of combustion output variables to experimental measurements. Effect of the mesh size on the temperature evolutions is investigated and optimum grid size is suggested. Effect of width openings is investigated. Temperature distribution and species flow are presented for different operating conditions. The effect of the composition of the used fuel on atmospheric pollution is also a focus point within this work. Good predictions are obtained where the size of the computational cells within the fire compartment is less than 1/10th of the characteristic fire diameter.
Abstract: System development life cycle (SDLC) is a
process uses during the development of any system. SDLC
consists of four main phases: analysis, design, implement and
testing. During analysis phase, context diagram and data flow
diagrams are used to produce the process model of a system.
A consistency of the context diagram to lower-level data flow
diagrams is very important in smoothing up developing
process of a system. However, manual consistency check from
context diagram to lower-level data flow diagrams by using a
checklist is time-consuming process. At the same time, the
limitation of human ability to validate the errors is one of the
factors that influence the correctness and balancing of the
diagrams. This paper presents a tool that automates the
consistency check between Data Flow Diagrams (DFDs)
based on the rules of DFDs. The tool serves two purposes: as
an editor to draw the diagrams and as a checker to check the
correctness of the diagrams drawn. The consistency check
from context diagram to lower-level data flow diagrams is
embedded inside the tool to overcome the manual checking
problem.
Abstract: In this work, axisymetric CFD simulation of fixed bed
GTL reactor has been conducted, using computational fluid dynamics
(CFD). In fixed bed CFD modeling, when N (tube-to-particle
diameter ratio) has a large value, it is common to consider the packed
bed as a porous media. Synthesis gas (a mixture of predominantly
carbon monoxide and hydrogen) was fed to the reactor. The reactor
length was 20 cm, divided to three sections. The porous zone was in
the middle section of the reactor. The model equations were solved
employing finite volume method. The effects of particle diameter,
bed voidage, fluid velocity and bed length on pressure drop have
been investigated. Simulation results showed these parameters could
have remarkable impacts on the reactor pressure drop.
Abstract: This paper presents an experimental investigation of
transformer dielectric response and solid insulation water content.
The dielectric response was carried out on the base of Hybrid
Frequency Dielectric Spectroscopy and Polarization Current
measurements method (FDS &PC). The calculation of the water
content in paper is based on the water content in oil and the obtained
equilibrium curves. A reference measurements were performed at
equilibrium conditions for water content in oil and paper of
transformer at different stable temperatures (25, 50, 60 and 70°C) to
prepare references to evaluate the insulation behavior at the not
equilibrium conditions. Some measurements performed at the
different simulated normal working modes of transformer operation
at the same temperature where the equilibrium conditions. The
obtained results show that when transformer temperature is mach
more than the its ambient temperature, the transformer temperature
decreases immediately after disconnecting the transformer from the
network and this temperature reduction influences the transformer
insulation condition in the measuring process. In addition to the oil
temperature at the near places to the sensors, the temperature
uniformity in transformer which can be changed by a big change in
the load of transformer before the measuring time will influence the
result. The investigations have shown that the extremely influence of
the time between disconnecting the transformer and beginning the
measurements on the results. And the online monitoring for water
content in paper measurements, on the basis of the oil water content
on line monitoring and the obtained equilibrium curves. The
measurements where performed continuously and for about 50 days
without any disconnection in the prepared the adiabatic room.
Abstract: In this paper, we propose a practical digital music matching system that is robust to variation in sound qualities. The proposed system is subdivided into two parts: client and server. The client part consists of the input, preprocessing and feature extraction modules. The preprocessing module, including the music onset module, revises the value gap occurring on the time axis between identical songs of different formats. The proposed method uses delta-grouped Mel frequency cepstral coefficients (MFCCs) to extract music features that are robust to changes in sound quality. According to the number of sound quality formats (SQFs) used, a music server is constructed with a feature database (FD) that contains different sub feature databases (SFDs). When the proposed system receives a music file, the selection module selects an appropriate SFD from a feature database; the selected SFD is subsequently used by the matching module. In this study, we used 3,000 queries for matching experiments in three cases with different FDs. In each case, we used 1,000 queries constructed by mixing 8 SQFs and 125 songs. The success rate of music matching improved from 88.6% when using single a single SFD to 93.2% when using quadruple SFDs. By this experiment, we proved that the proposed method is robust to various sound qualities.
Abstract: In this work a new method for low complexity
image coding is presented, that permits different settings and great
scalability in the generation of the final bit stream. This coding
presents a continuous-tone still image compression system that
groups loss and lossless compression making use of finite arithmetic
reversible transforms. Both transformation in the space of color and
wavelet transformation are reversible. The transformed coefficients
are coded by means of a coding system in depending on a
subdivision into smaller components (CFDS) similar to the bit
importance codification. The subcomponents so obtained are
reordered by means of a highly configure alignment system
depending on the application that makes possible the re-configure of
the elements of the image and obtaining different importance levels
from which the bit stream will be generated. The subcomponents of
each importance level are coded using a variable length entropy
coding system (VBLm) that permits the generation of an embedded
bit stream. This bit stream supposes itself a bit stream that codes a
compressed still image. However, the use of a packing system on the
bit stream after the VBLm allows the realization of a final highly
scalable bit stream from a basic image level and one or several
improvement levels.
Abstract: In this work a new offline signature recognition system
based on Radon Transform, Fractal Dimension (FD) and Support Vector Machine (SVM) is presented. In the first step, projections of
original signatures along four specified directions have been performed using radon transform. Then, FDs of four obtained
vectors are calculated to construct a feature vector for each
signature. These vectors are then fed into SVM classifier for recognition of signatures. In order to evaluate the effectiveness of
the system several experiments are carried out. Offline signature
database from signature verification competition (SVC) 2004 is used
during all of the tests. Experimental result indicates that the proposed method achieved high accuracy rate in signature recognition.
Abstract: A new method for low complexity image coding is presented, that permits different settings and great scalability in the generation of the final bit stream. This coding presents a continuoustone still image compression system that groups loss and lossless compression making use of finite arithmetic reversible transforms. Both transformation in the space of color and wavelet transformation are reversible. The transformed coefficients are coded by means of a coding system in depending on a subdivision into smaller components (CFDS) similar to the bit importance codification. The subcomponents so obtained are reordered by means of a highly configure alignment system depending on the application that makes possible the re-configure of the elements of the image and obtaining different levels of importance from which the bit stream will be generated. The subcomponents of each level of importance are coded using a variable length entropy coding system (VBLm) that permits the generation of an embedded bit stream. This bit stream supposes itself a bit stream that codes a compressed still image. However, the use of a packing system on the bit stream after the VBLm allows the realization of a final highly scalable bit stream from a basic image level and one or several enhance levels.
Abstract: The objective of this study is to investigate fire
behaviors, experimentally and numerically, in a scaled version of an
underground station. The effect of ventilation velocity on the fire is
examined. Fire experiments are simulated by burning 10 ml
isopropyl alcohol fuel in a fire pool with dimensions 5cm x 10cm x 4
mm at the center of 1/100 scaled underground station model. A
commercial CFD program FLUENT was used in numerical
simulations. For air flow simulations, k-ω SST turbulence model and
for combustion simulation, non-premixed combustion model are
used. This study showed that, the ventilation velocity is increased
from 1 m/s to 3 m/s the maximum temperature in the station is found
to be less for ventilation velocity of 1 m/s. The reason for these
experimental result lies on the relative dominance of oxygen supply
effect on cooling effect. Without piston effect, maximum temperature
occurs above the fuel pool. However, when the ventilation velocity
increased the flame was tilted in the direction of ventilation and the
location of maximum temperature moves along the flow direction.
The velocities measured experimentally in the station at different
locations are well matched by the CFD simulation results. The
prediction of general flow pattern is satisfactory with the smoke
visualization tests. The backlayering in velocity is well predicted by
CFD simulation. However, all over the station, the CFD simulations
predicted higher temperatures compared to experimental
measurements.
Abstract: In intensity modulated radiation therapy (IMRT)
treatment planning, beam angles are usually preselected on the basis of
experience and intuition. Therefore, getting an appropriate beam
configuration needs a very long time. Based on the present situation,
the paper puts forward beam orientation optimization using ant colony
optimization (ACO). We use ant colony optimization to select the
beam configurations, after getting the beam configuration using
Conjugate Gradient (CG) algorithm to optimize the intensity profiles.
Combining with the information of the effect of pencil beam, we can
get the global optimal solution accelerating. In order to verify the
feasibility of the presented method, a simulated and clinical case was
tested, compared with dose-volume histogram and isodose line
between target area and organ at risk. The results showed that the
effect was improved after optimizing beam configurations. The
optimization approach could make treatment planning meet clinical
requirements more efficiently, so it had extensive application
perspective.