Abstract: Solenoid operated electromagnetic control valve
(ECV) playing an important role for car’s air conditioning control
system. ECV is used in external variable displacement swash plate
type compressor and controls the entire air conditioning system by
means of a pulse width modulation (PWM) input signal supplying
from an external source (controller). Complete form of ECV contains
number of internal features like valve body, core, valve guide,
plunger, guide pin, plunger spring, bellows etc. While designing the
ECV; dimensions of different internal items must meet the standard
requirements as it is quite challenging. In this research paper,
especially the dimensioning of ECV body and its three pressure ports
through which the air/refrigerant passes are considered. Here internal
leakage test analysis of ECV body is being carried out from its
discharge port (Pd) to crankcase port (Pc) when the guide valve is
placed inside it. The experiments have made both in ordinary and
digital system using different assumptions and thereafter compare the
results.
Abstract: The aim of this study was to design and simulate a
particular type of Asynchronous State Machine (ASM), namely a
‘traffic light controller’ (TLC), operated at a frequency of 0.5 Hz.
The design task involved two main stages: firstly, designing a 4-bit
binary counter using J-K flip flops as the timing signal and,
subsequently, attaining the digital logic by deploying ASM design
process. The TLC was designed such that it showed a sequence of
three different colours, i.e. red, yellow and green, corresponding to
set thresholds by deploying the least number of AND, OR and NOT
gates possible. The software Multisim was deployed to design such
circuit and simulate it for circuit troubleshooting in order for it to
display the output sequence of the three different colours on the
traffic light in the correct order. A clock signal, an asynchronous 4-
bit binary counter that was designed through the use of J-K flip flops
along with an ASM were used to complete this sequence, which was
programmed to be repeated indefinitely. Eventually, the circuit was
debugged and optimized, thus displaying the correct waveforms of
the three outputs through the logic analyser. However, hazards
occurred when the frequency was increased to 10 MHz. This was
attributed to delays in the feedback being too high.
Abstract: The problem of psychologist training remains a key
priority in Armenia. During the Soviet period, the notion of a
psychologist was obscure not only in Armenia but also in other
Soviet republics. The breakup of the Soviet Union triggered a gradual
change in this area activating the cooperation with specialists from
other countries. The need for recovery from the psychological trauma
caused by the 1988 earthquake pushed forward the development of
practical psychology in Armenia. This phenomenon led to positive
changes in perception of and interest to a psychologist
profession.Armenian universities started designing special programs
for psychologists’ preparation. Armenian psychologists combined
their efforts in the field of training relevant specialists.
During the recent years, the Bologna educational system was
introduced in Armenia which led to implementation of education
quality improvement programs. Nevertheless, even today the issue of
psychologists’ training is not yet settled in Armenian universities. So
far graduate psychologists haven’t got a clear idea of personal and
professional qualities of a psychologist. Recently, as a result of
educational reforms, the psychology curricula underwent changes,
but so far they have not led to a desired outcome. Almost all curricula
in certain specialties are aimed to form professional competencies
and strengthen practical skills.
A survey conducted in Armenia aimed to identify what are the
ideas of young psychology specialists on the image of a psychologist.
The survey respondents were 45 specialists holding bachelor’s degree
as well as 30 master degree graduates, who have not been working
yet. The research reveals that we need to change the approach of
preparing psychology practitioners in the universities of Armenia.
Such an approach to psychologist training will make it possible to
train qualified specialists for enhancement of modern psychology
theory and practice.
Abstract: Burnishing is increasingly used as a finishing operation to improve surface roughness and surface hardness. This can be achieved by applying a hard ball or roller onto metallic surfaces under pressure, in order to achieve many advantages in the metallic surface. In the present work, the feed rate, speed and force have been considered as the basic burnishing parameters to study the surface roughness and surface hardness of metallic matrix composites. The considered metal matrix composites were made from Aluminum-Magnesium-Graphite with five different weight percentage of graphite. Both effects of burnishing parameters mentioned above and the graphite percentage on the surface hardness and surface roughness of the metallic matrix composites were studied. The results of this investigation showed that the surface hardness of the metallic composites increases with the increase of the burnishing force and decreases with the increase in the burnishing feed rate and burnishing speed. The surface roughness of the metallic composites decreases with the increasing of the burnishing force, feed rate, and speed to certain values, then it starts to increase. On the other hand, the increase in the weight percentage of the graphite in the considered composites causes a decrease in the surface hardness and an increase in the surface roughness.
Abstract: In order to better understand the long term
implications of the grout wear failure mode in large-diameter plainsided
grouted connections, a numerical model has been developed
and calibrated that can take advantage of existing operational plant
data to predict the wear accumulation for the actual load conditions
experienced over a given period, thus limiting the requirement for
expensive monitoring systems. This model has been derived and
calibrated based on site structural condition monitoring (SCM) data
and supervisory control and data acquisition systems (SCADA) data
for two operational wind turbine generator substructures afflicted
with this challenge, along with experimentally derived wear rates.
Abstract: The design, manufacture, and operation of thin-walled
pressure vessels must be based on maximum safe operating pressure
and an adequate factor of safety (FoS). This research paper first
reports experimental evaluation of longitudinal and hoops stresses
based on working pressure as well as maximum pressure; and then
includes a critical study of factor of safety (FoS) in the design of a
glass fiber pressure vessel. Experimental work involved the use of
measuring instruments and the readings from pressure gauges.
Design calculations involved the computations of design stress and
FoS; the latter was based on breaking strength of 55 MPa for the
glass fiber (pressure-vessel material). The experimentally determined
FoS value has been critically compared with the general FoS allowed
in the design of glass fiber pressure vessels.
Abstract: This paper presents analysis and design of a wideband
Wilkinson power divider for wireless applications. The design is
accomplished by transforming the lengths and impedances of the
quarter wavelength sections of the conventional Wilkinson power
divider into U-shaped sections. The designed power divider is
simulated by using ADS Agilent technologies and CST microwave
studio software. It is shown that the proposed power divider has
simple topology and good performances in terms of insertion loss,
port matching and isolation at all operating frequencies (1.8 GHz,
2.45 GHz and 3.55 GHz).
Abstract: Lightweight design represents an important key to
successful implementation of energy-saving, fuel-efficient and
environmentally friendly means of transport in the aerospace and
automotive industry. In this context the use of carbon fibre reinforced
plastics (CFRP) which are distinguished by their outstanding
mechanical properties at relatively low weight, promise significant
improvements. Due to the reduction of the total mass, with the
resulting lowered fuel or energy consumption and CO2 emissions
during the operational phase, commercial aircraft will increasingly be
made of CFRP. An auspicious technology for the efficient and
economic production of high performance thermoset composites and
hybrid structures for future lightweight applications is the
combination of carbon fibre sheet moulding compound, tailored
continuous carbon fibre reinforcements and metallic components in a
one-shot pressing and curing process. This paper deals with a hybrid
composite technology for aerospace industries, which was developed
with the help of a special innovation and development system.
Abstract: This paper presents the development of a single-ended 38.5 kS/s 10-bit programmable reference SAR ADC which is realized in MIMOS’s 0.35 µm CMOS process. The design uses a resistive DAC, a dynamic comparator with pre-amplifier and a SAR digital logic to create 10 effective bits ADC. A programmable reference circuitry allows the ADC to operate with different input range from 0.6 V to 2.1 V. The ADC consumed less than 7.5 mW power with a 3 V supply.
Abstract: A thermosyphon system is a heat transfer loop which
operates on the basis of gravity and buoyancy forces. It guarantees a
good reliability and low maintenance cost as it does not involve any
mechanical pump. Therefore, it can be used in many industrial
applications such as refrigeration and air conditioning, electronic
cooling, nuclear reactors, geothermal heat extraction, etc. But flow
instabilities and loop configuration are the major problems in this
system. Several previous researchers studied that stabilities can be
suppressed by using nanofluids as loop fluid. In the present study a
rectangular thermosyphon loop with end heat exchangers are
considered for the study. This configuration is more appropriate for
many practical applications such as solar water heater, geothermal
heat extraction, etc. In the present work, steady-state analysis is
carried out on thermosyphon loop with parallel flow coaxial heat
exchangers at heat source and heat sink. In this loop nanofluid is
considered as the loop fluid and water is considered as the external
fluid in both hot and cold heat exchangers. For this analysis onedimensional
homogeneous model is developed. In this model,
conservation equations like conservation of mass, momentum, energy
are discretized using finite difference method. A computer code is
written in MATLAB to simulate the flow in thermosyphon loop. A
comparison in terms of heat transfer is made between water and
nanofluid as working fluids in the loop.
Abstract: In this paper, the transient device performance analysis
of n-type Gate Inside JunctionLess Transistor (GI-JLT) has been
evaluated. 3-D Bohm Quantum Potential (BQP) transport device
simulation has been used to evaluate the delay and power dissipation
performance. GI-JLT has a number of desirable device parameters
such as reduced propagation delay, dynamic power dissipation,
power and delay product, intrinsic gate delay and energy delay
product as compared to Gate-all-around transistors GAA-JLT. In
addition to this, various other device performance parameters namely,
on/off current ratio, short channel effects (SCE), transconductance
Generation Factor (TGF) and unity gain cut-off frequency (fT ) and
subthreshold slope (SS) of the GI-JLT and GAA-JLT have been
analyzed and compared. GI-JLT shows better device performance
characteristics than GAA-JLT for low power and high frequency
applications, because of its larger gate electrostatic control on the
device operation.
Abstract: The objective of this research is to design and
construct the PV-Wind hybrid autonomous system for the greenhouse
plantation, and analyze the technical performance of the PV-Wind
energy system. This design depends on the water consumption in the
greenhouse by using 24 of the fogging mist each with the capability
of 24 liter/min. The operating time is 4 times per day, each round for
15 min. The fogging system is being driven by water pump with AC
motor rating 0.5 hp. The load energy consumed is around 1.125
kWh/d. The designing results of the PV-Wind hybrid energy system
is that sufficient energy could be generated by this system. The
results of this study can be applied as a technical data reference for
other areas in the central part of Thailand.
Abstract: In this paper cognitive radio is presented and the
spectrum overlay cognitive radio antenna system is detailed. A UWB
antenna with frequency reconfigurable characteristics is proposed.
The reconfigurability is achieved when the filter is integrated to the
feeding line of the single port overlay cognitive radio. When
activated, the filter can transform the UWB frequency response into a
reconfigurable narrowband one, which is suitable for the
communication operation of the CR system. Here single port overlay
cognitive radio antenna is designed and simulated using Ansoft High
Frequency Structure Simulator (HFSS).
Abstract: The final energy use can be divided mainly in four sectors: commercial, industrial, residential, and transportation. The trend in final energy consumption by sector plays as a most straightforward way to provide a wide indication of progress for reducing energy consumption and associated environmental impacts by different end use sectors. The average share of end use energy for residential sector in the world was nearly 20% until 2011, in Germany a higher proportion is between 25% and 30%. However, it remains less studied than energy use in other three sectors as well its impacts on climate and environment. The reason for this involves a wide range of fields, including the diversity of residential construction like different housing building design and materials, living or energy using behavioral patterns, climatic condition and variation as well other social obstacles, market trend potential and financial support from government.
This paper presents an extensive and in-depth analysis of the manner by which projects researched and operated by authors in the fields of energy efficiency primarily from the perspectives of both technical potential and initiative energy saving consciousness in the residential sectors especially in social housing buildings.
Abstract: Wet scrubbers have found widespread use in cleaning
contaminated gas streams because of their ability to remove
particulates and based on the applications of scrubbing of marine
engine exhaust gases by spraying sea-water. In order to examine the
flow characteristics inside the scrubber, the model is designated with
flow properties of hot air and water sprayer. The flow dynamics of
evaporation of hot air by the injection of water droplets is the key
factor considered in this paper. The flow behavior inside the scrubber
was investigated from the previous works and to sum up the
evaporation rate with respect to the concentration of water droplets are
predicted to bring out the competent modelling. The numerical
analysis using CFD facilitates in understanding the problem better and
empathies the behavior of the model over its entire operating envelope.
Abstract: Higher order ΔΣ Modulator (DSM) is basically an
unstable system. The approximate conditions for stability cannot be
used for the design of a DSM for industrial applications where risk is
involved. The existing second order, single stage, single bit, unity
feedback gain , discrete DSM cannot be used for the normalized full
range (-1 to +1) of an input signal since the DSM becomes unstable
when the input signal is above ±0.55. The stability is also not
guaranteed for input signals of amplitude less than ±0.55. In the
present paper, the above mentioned second order DSM is modified
with input signal dependent forward path gain. The proposed DSM is
suitable for industrial applications where one needs the digital
representation of the analog input signal, during each sampling
period. The proposed DSM can operate almost for the full range of
input signals (-0.95 to +0.95) without causing instability, assuming
that the second integrator output should not exceed the circuit supply
voltage, ±15 Volts.
Abstract: There is decagram of strategic decisions of operations
and production/service management (POSM) within operational
research (OR) which must collate, namely: design, inventory, quality,
location, process and capacity, layout, scheduling, maintain ace, and
supply chain. This paper presents an architectural configuration
conceptual framework of a decagram of sets decisions in a form of
mathematical complete graph and abelian graph.
Mathematically, a complete graph is undirected (UDG), and
directed (DG) a relationship where every pair of vertices is
connected, collated, confluent, and holomorphic.
There has not been any study conducted which, however,
prioritizes the holomorphic sets which of POMS within OR field of
study. The study utilizes OR structured technique known as The
Analytic Hierarchy Process (AHP) analysis for organizing, sorting
and prioritizing(ranking) the sets within the decagram of POMS
according to their attribution (propensity), and provides an analysis
how the prioritization has real-world application within the 21st
century.
Abstract: Presently, engine cooling pump is driven by toothed
belt. Therefore, the pump speed is dependent on engine speed which
varies their output. At normal engine operating conditions (Higher
RPM and low load, Higher RPM and high load), mechanical water
pumps in existing engines are inevitably oversized and so the use of
an electric water pump together with state-of-the-art thermal
management of the combustion engine has measurable advantages.
Demand-driven cooling, particularly in the cold-start phase, saves
fuel (approx 3 percent) and leads to a corresponding reduction in
emissions. The lack of dependence on a mechanical drive also results
in considerable flexibility in component packaging within the engine
compartment. This paper describes the testing and comparison of
existing mechanical water pump with that of the electric water pump.
When the existing mechanical water pump is replaced with the new
electric water pump the percentage gain in system efficiency is also
discussed.
Abstract: In this study, the performance analyses of the twenty
five Coal-Fired Power Plants (CFPPs) used for electricity generation
are carried out through various Data Envelopment Analysis (DEA)
models. Three efficiency indices are defined and pursued. During the
calculation of the operational performance, energy and non-energy
variables are used as input, and net electricity produced is used as
desired output (Model-1). CO2 emitted to the environment is used as
the undesired output (Model-2) in the computation of the pure
environmental performance while in Model-3 CO2 emissions is
considered as detrimental input in the calculation of operational and
environmental performance. Empirical results show that most of the
plants are operating in increasing returns to scale region and Mettur
plant is efficient one with regards to energy use and environment.
The result also indicates that the undesirable output effect is
insignificant in the research sample. The present study will provide
clues to plant operators towards raising the operational and
environmental performance of CFPPs.
Abstract: One of the major difficulties introduced with wind
power penetration is the inherent uncertainty in production originating
from uncertain wind conditions. This uncertainty impacts many
different aspects of power system operation, especially the balancing
power requirements. For this reason, in power system development
planing, it is necessary to evaluate the potential uncertainty in future
wind power generation. For this purpose, simulation models are
required, reproducing the performance of wind power forecasts.
This paper presents a wind power forecast error simulation models
which are based on the stochastic process simulation. Proposed
models capture the most important statistical parameters recognized
in wind power forecast error time series. Furthermore, two distinct
models are presented based on data availability. First model uses
wind speed measurements on potential or existing wind power plant
locations, while the seconds model uses statistical distribution of wind
speeds.