Abstract: In sheet metal forming process, raw material
mechanical properties are important parameters. This paper is to
compare the wall’s incline angle or formability of SS 400 steel and
SUS 304 stainless steel in single point incremental forming. The two
materials are ferrous base alloyed, which have the different unit cell,
mechanical property and chemical composition. They were forming
into cone shape specimens having 100 mm diameter with different
wall’s incline angle: 90o, 75o and 60o. The investigation was
continued until the specimens formed surface facture. The
experimental result showed that the smaller the wall incline angle
higher the formability with the both materials. The formability limit
of the ferrous base alloy was approx. 60o wall’s incline angle. By
nature, SS 400 has higher formability than SUS 304. This result can
be used as the initial data in designing the single point incremental
forming parts.
Abstract: There are a variety of reference current identification
methods, for the shunt active power filter (SAPF), such as the
instantaneous active and reactive power, the instantaneous active and
reactive current and the synchronous detection method are evaluated
and compared under ideal, non sinusoidal and unbalanced voltage
conditions. The SAPF performances, for the investigated
identification methods, are tested for a non linear load. The
simulation results, using Matlab Power System Blockset Toolbox
from a complete structure, are presented and discussed.
Abstract: The purpose of this work is examining the multiproduct
multi-stage in a battery production line. To improve the
performances of an assembly production line by determine the
efficiency of each workstation. Data collected from every
workstation. The data are throughput rate, number of operator, and
number of parts that arrive and leaves during part processing. Data
for the number of parts that arrives and leaves are collected at least at
the amount of ten samples to make the data is possible to be analyzed
by Chi-Squared Goodness Test and queuing theory. Measures of this
model served as the comparison with the standard data available in
the company. Validation of the task time value resulted by comparing
it with the task time value based on the company database. Some
performance factors for the multi-product multi-stage in a battery
production line in this work are shown.
The efficiency in each workstation was also shown. Total
production time to produce each part can be determined by adding
the total task time in each workstation. To reduce the queuing time
and increase the efficiency based on the analysis any probably
improvement should be done. One probably action is by increasing
the number of operators how manually operate this workstation.
Abstract: Botnets are one of the most serious and widespread
cyber threats. Today botnets have been facilitating many
cybercrimes, especially financial, top secret thefts. Botnets can be
available for lease in the market and are utilized by the
cybercriminals to launch massive attacks like DDoS, click fraud,
phishing attacks etc., Several large institutions, hospitals, banks,
government organizations and many social networks such as twitter,
facebook etc., became the target of the botmasters. Recently,
noteworthy researches have been carried out to detect bot, C&C
channels, botnet and botmasters. Using many sophisticated
technologies, botmasters made botnet a titan of the cyber world.
Innumerable challenges have been put forth by the botmasters to the
researchers in the detection of botnet. In this paper we present a
survey of different types of botnet C&C channels and also provide a
comparison of various botnet categories. Finally we hope that our
survey will create awareness for forthcoming botnet research
endeavors.
Abstract: Pesticides and drugs used in agriculture and veterinary
medicine may end up in aquatic environments and bioaccumulate in
the food chain, thus causing serious problems for fauna and human
health. For determination of the toxic effects of atrazine herbicide on
Caspian kutum, Rutilus frisii kutum larvae, the 96-h LC50 of atrazine
was measured for newly hatched larvae as 18.53 ppm. Toxicity of
atrazine herbicide on Caspian kutum larvae was investigated using
concentrations: 9.25ppm, 4.62 ppm and 2.31 ppm for 7 days.
Comparison of the length, weight and condition factor showed that
no significant differences between atrazine exposed and control
groups. The concentration of Na+, K+, Ca2+, Mg2+ and Cl- in whole
body of larvae in control and atrazine exposure groups were
measured and the results showed that concentrations of all these ions
is higher in atrazine exposure group than control group. It is obvious
from this study that atrazine negatively affects osmoregulation
process and changes ion compositions of the body even at sublethal
concentration and acute exposure but have no effects on growth
parameters of the body.
Abstract: The objective of the Economic Dispatch(ED) Problems
of electric power generation is to schedule the committed generating
units outputs so as to meet the required load demand at minimum
operating cost while satisfying all units and system equality and
inequality constraints. This paper presents a new method of ED
problems utilizing the Max-Min Ant System Optimization.
Historically, traditional optimizations techniques have been used,
such as linear and non-linear programming, but within the past
decade the focus has shifted on the utilization of Evolutionary
Algorithms, as an example Genetic Algorithms, Simulated Annealing
and recently Ant Colony Optimization (ACO). In this paper we
introduce the Max-Min Ant System based version of the Ant System.
This algorithm encourages local searching around the best solution
found in each iteration. To show its efficiency and effectiveness, the
proposed Max-Min Ant System is applied to sample ED problems
composed of 4 generators. Comparison to conventional genetic
algorithms is presented.
Abstract: Magnetic powder of Sr-ferrite was prepared by
conventional and sol-gel auto-combustion methods. In conventional
method, strontium carbonate and ferric oxide powders were mixed
together and then mixture was calcined. In sol-gel auto-combustion
method, a solution containing strontium nitrate, ferric nitrate and
citric acid was heated until the combustion took place automatically;
then, as-burnt powder was calcined. Thermal behavior, phase
identification, morphology and magnetic properties of powders
obtained by these two methods were compared by DTA, XRD, SEM
and VSM techniques. According to the results of DTA analysis,
formation temperature of Sr-ferrite obtained by conventional and solgel
auto-combustion methods were 1300°C and 1000°C, respectively.
XRD results confirmed the formation of pure Sr-ferrite at the
mentioned temperatures. Plate and hexagonal-shape particles of Srferrite
were observed using SEM. The Sr-ferrite powder obtained by
sol-gel auto-combustion method had saturation magnetization of
66.03 emu/g and coercivity of 5731 Oe in comparison with values of
58.20 emu/g and 4378 Oe obtained by conventional method.
Abstract: Electricity is recognized as fundamental to
industrialization and improving the quality of life of the people.
Harnessing the immense untapped hydropower potential in Tripura
region opens avenues for growth and provides an opportunity to
improve the well-being of the people of the region, while making
substantial contribution to the national economy. Gumti hydro power
plant generates power to mitigate the crisis of power in Tripura,
India. The first unit of hydro power plant (5MW) was commissioned
in June 1976 & another two units of 5 MW was commissioned
simultaneously. But out of 15MW capacity at present only 8MW-
9MW power is produced from Gumti hydro power plant during rainy
season. But during lean season the production reduces to 0.5MW due
to shortage of water. Now, it is essential to implement some
mitigation measures so that the further atrocities can be prevented
and originality will be possible to restore. The decision making
ability of the Analytic Hierarchy Process (AHP) and Concordance
Analysis Techniques (CAT) are utilized to identify the better decision
or solution to the present problem. Some related attributes are
identified by the method of surveying within the experts and the
available reports and literatures. Similar criteria are removed and
ultimately seven relevant ones are identified. All the attributes are
compared with each other and rated accordingly to their importance
over the other with the help of Pair wise Comparison Matrix. In the
present investigation different mitigation measures are identified and
compared to find the best suitable alternative which can solve the
present uncertainties involving the existence of the Gumti Hydro
Power Plant.
Abstract: This paper explains about the voltage output for DC to
DC boost converter between open loop, PID controller and fuzzy
logic controller through Matlab Simulink. Simulink input voltage was
set at 12V and the voltage reference was set at 24V. The analysis on
the deviation of voltage resulted that the difference between reference
voltage setting and the output voltage is always lower. Comparison
between open loop, PID and FLC shows that, the open loop circuit
having a bit higher on the deviation of voltage. The PID circuit
boosts for FLC has a lesser deviation of voltage and proved that it is
such a better performance on control the deviation of voltage during
the boost mode.
Abstract: A computational fluid dynamics simulation is done for
non-Newtonian fluid in a baffled stirred tank. The CMC solution is
taken as non-Newtonian shear thinning fluid for simulation. The
Reynolds Average Navier Stocks equation with steady state multi
reference frame approach is used to simulate flow in the stirred tank.
The turbulent flow field is modelled using realizable k-ε turbulence
model. The simulated velocity profiles of Rushton turbine is
validated with literature data. Then, the simulated flow field of CD-6
impeller is compared with the Rushton turbine. The flow field
generated by CD-6 impeller is less in magnitude than the Rushton
turbine. The impeller global parameter, power number and flow
number, and entropy generation due to viscous dissipation rate is also
reported.
Abstract: At-site flood frequency analysis is used to estimate
flood quantiles when at-site record length is reasonably long. In
Australia, FLIKE software has been introduced for at-site flood
frequency analysis. The advantage of FLIKE is that, for a given
application, the user can compare a number of most commonly
adopted probability distributions and parameter estimation methods
relatively quickly using a windows interface. The new version of
FLIKE has been incorporated with the multiple Grubbs and Beck test
which can identify multiple numbers of potentially influential low
flows. This paper presents a case study considering six catchments in
eastern Australia which compares two outlier identification tests
(original Grubbs and Beck test and multiple Grubbs and Beck test)
and two commonly applied probability distributions (Generalized
Extreme Value (GEV) and Log Pearson type 3 (LP3)) using FLIKE
software. It has been found that the multiple Grubbs and Beck test
when used with LP3 distribution provides more accurate flood
quantile estimates than when LP3 distribution is used with the
original Grubbs and Beck test. Between these two methods, the
differences in flood quantile estimates have been found to be up to
61% for the six study catchments. It has also been found that GEV
distribution (with L moments) and LP3 distribution with the multiple
Grubbs and Beck test provide quite similar results in most of the
cases; however, a difference up to 38% has been noted for flood
quantiles for annual exceedance probability (AEP) of 1 in 100 for one
catchment. This finding needs to be confirmed with a greater number
of stations across other Australian states.
Abstract: This paper present the experimental work of double
unit tunnel form building (TFB) subjected to in-plane lateral cyclic
loading. A one third scale of 3-storey double unit of TFB is tested
until its strength degradation. Then, the TFB is repaired and
retrofitted using additional shear wall, steel angle and CFRP sheet.
The crack patterns, lateral strength, stiffness, ductility and equivalent
viscous damping (EVD) were analyzed and compared before and
after repair and retrofit. The result indicates that the lateral strength
increases by 22% in pushing and 27% in pulling direction. Moreover,
the stiffness and ductility obtained before and after retrofit increase
tremendously by 87.87% and 39.66%, respectively. Meanwhile, the
energy absorption measured by equivalent viscous damping obtained
after retrofit increase by 12.34% in pulling direction. It can be
concluded that the proposed retrofit method is capable to increase the
lateral strength capacity, stiffness and energy absorption of double
unit TFB.
Abstract: Supermarkets are the most electricity-intensive type of
commercial buildings. The unsuitable indoor environment of a
supermarket provided by abnormal HVAC operations incurs waste
energy consumption in refrigeration systems. This current study
briefly describes significantly solid backgrounds and proposes easyto-
use analysis terminology for investigating the impact of HVAC
operations on refrigeration power consumption using the field-test
data obtained from building automation system (BAS). With solid
backgrounds and prior knowledge, expected energy interactions
between HVAC and refrigeration systems are proposed through
Pearson’s correlation analysis (R value) by considering correlations
between equipment power consumption and dominantly independent
variables (driving force conditions).The R value can be conveniently
utilized to evaluate how strong relations between equipment
operations and driving force parameters are. The calculated R values
obtained from field data are compared to expected ranges of R values
computed by energy interaction methodology. The comparisons can
separate the operational conditions of equipment into faulty and
normal conditions. This analysis can simply investigate the condition
of equipment operations or building sensors because equipment could
be abnormal conditions due to routine operations or faulty
commissioning processes in field tests. With systematically solid and
easy-to-use backgrounds of interactions provided in the present
article, the procedures can be utilized as a tool to evaluate the proper
commissioning and routine operations of HVAC and refrigeration
systems to detect simple faults (e.g. sensors and driving force
environment of refrigeration systems and equipment set-point) and
optimize power consumption in supermarket buildings. Moreover,
the analysis will be used to further study the FDD research for
supermarkets in future.
Abstract: With advances in solid-state power electronic devices
and microprocessors, various pulse-width-modulation (PWM)
techniques have been developed for industrial applications. This
paper presents the comparison of two different PWM techniques, the
sinusoidal PWM (SPWM) technique and the space-vector PWM
(SVPWM) technique applied to two level VSI for micro grid
applications. These two methods are compared by discussing their
ease of implementation and by analyzing the output harmonic spectra
of various output voltages (line-to-neutral voltages, and line-to-line
voltages) and their total harmonic distortion (THD). The SVPWM
technique in the under-modulation region can increase the
fundamental output voltage by 15.5% over the SPWM technique.
Abstract: Bone properties and response behavior after static or
dynamic activation (loading) are still interesting topics in many fields
of the science especially in the biomechanical problems such as bone
loss of astronauts in space, osteoporosis, bone remodeling after
fracture or remodeling after surgery (endoprosthesis and implants)
and in osteointegration. This contribution deals with the relation
between physiological, demineralized and deproteinized state of the
turkey long bone – tibia. Three methods for comparison were used: 1)
densitometry, 2) three point bending and 3) frequency analysis. The
main goal of this work was to describe the decrease of the protein
(collagen) or mineral of the bone with relation to the fracture in three
point bending. The comparison is linked to the problem of different
bone mechanical behavior in physiological and osteoporotic state.
Abstract: The North-eastern part of India, which receives
heavier rainfall than other parts of the subcontinent, is of great
concern now-a-days with regard to climate change. High intensity
rainfall for short duration and longer dry spell, occurring due to
impact of climate change, affects river morphology too. In the present
study, an attempt is made to delineate the North-eastern region of
India into some homogeneous clusters based on the Fuzzy Clustering
concept and to compare the resulting clusters obtained by using
conventional methods and nonconventional methods of clustering.
The concept of clustering is adapted in view of the fact that, impact
of climate change can be studied in a homogeneous region without
much variation, which can be helpful in studies related to water
resources planning and management. 10 IMD (Indian Meteorological
Department) stations, situated in various regions of the North-east,
have been selected for making the clusters. The results of the Fuzzy
C-Means (FCM) analysis show different clustering patterns for
different conditions. From the analysis and comparison it can be
concluded that nonconventional method of using GCM data is
somehow giving better results than the others. However, further
analysis can be done by taking daily data instead of monthly means to
reduce the effect of standardization.
Abstract: This paper presents a comparison between using a
desktop web application and a mobile application for students
enrolling in courses at Rangsit University, Thailand. In addition,
Rangsit University has enhanced the enrollment process by
leveraging its information systems, which allows students to choose
to enroll in courses online. In order to use the system, students must
provide their identification and personal documents for registration.
The reason to have a mobile application is to support students’ ability
to access the system at anytime, anywhere and anyplace. The
objective of this paper was to: 1. Evaluate the success of developing a
user friendly mobile device system and 2. Measure user interest in
future mobile development.
Abstract: This paper considers the characterization of a complex
electromagnetic environment due to multiple sources of
electromagnetic radiation as a five-dimensional surface which can be
described by a set of several surface sections including: instant EM
field intensity distribution maps at a given frequency and altitude,
instantaneous spectrum at a given location in space and the time
evolution of the electromagnetic field spectrum at a given point in
space. This characterization if done over time can enable the
exposure levels of Radio Frequency Radiation at every point in the
analysis area to be determined and results interpreted based on
comparison of the determined RFR exposure level with the safe
guidelines for general public exposure given by recognized body
such as the International commission on non-ionizing radiation
protection (ICNIRP), Institute of Electrical and Electronic Engineers
(IEEE), the National Radiation Protection Authority (NRPA).
Abstract: Communication and effective information exchange
within technology has become a crucial part of delivering knowledge
to students during the learning process. It enables better
understanding, builds trust and respect, and increases the sharing of
knowledge between students. This paper examines the
communication between undergraduate students and their lecturers
during the traditional lecture and when using the Interactive
Electronic Lecture System (IELS). The IELS is an application that
offers a set of components which support the effective
communication between students and their peers and between
students and their lecturers. Moreover, this paper highlights
communication skills such as sender, receiver, channel and feedback.
It will show how the IELS creates a rich communication environment
between its users and how they communicate effectively. To examine
and assess the effectiveness of communication, an experiment was
conducted on groups of users; students and lecturers. The first group
communicated in the traditional lecture while the second group
communicated by means of the IELS application. The results show
that there was more effective communication between the second
group than the first.
Abstract: This article presents summary on preparation and
characterization of zinc, copper, cadmium and cobalt chromite
nanocrystals, embedded in an amorphous silica matrix. The
ZnCr2O4/SiO2, CuCr2O4/SiO2, CdCr2O4/SiO2 and CoCr2O4/SiO2
nanocomposites were prepared by a conventional sol-gel method
under acid catalysis. Final heat treatment of the samples was carried
out at temperatures in the range of 900−1200 ◦C to adjust the
phase composition and the crystallite size, respectively. The resulting
samples were characterized by Powder X-ray diffraction (PXRD),
High Resolution Transmission Electron Microscopy (HRTEM),
Raman/FTIR spectroscopy and magnetic measurements. Formation
of the spinel phase was confirmed in all samples. The average size of
the nanocrystals was determined from the PXRD data and by direct
particle size observation on HRTEM; both results were correlated.
The mean particle size (reviewed by HRTEM) was in the range from
∼4 to 46 nm. The results showed that the sol-gel method can be
effectively used for preparation of the spinel chromite nanoparticles
embedded in the silica matrix and the particle size is driven by the
type of the cation A2+ in the spinel structure and the temperature
of the final heat treatment. Magnetic properties of the nanocrystals
were found to be just moderately modified in comparison to the bulk
phases.