Abstract: Precast residential houses are normally constructed in Malaysia using precast shear-key wall panel and this panel is designed using BS8110 where there is no provision for earthquake. However, the safety of this house under moderate and strong earthquake is still questionable. Consequently, the full-scale of residential house are designed, constructed, tested and analyzed under in-plane lateral quasi-static cyclic loading. Hysteresis loops are plotted based on the experimental work and compared with modeling of hysteresis loops using HYSTERES in RUAUMOKO 2D program. Modified Takeda hysteresis model is chosen to behave a similar pattern with experimental work. This program will display the earthquake excitations, spectral displacements, pseudo spectral acceleration, mode shape and deformation of the structure. It can be concluded that this building is suffering severe cracks and damage under moderate and severe earthquake.
Abstract: This paper present the experimental work of double
unit tunnel form building (TFB) subjected to in-plane lateral cyclic
loading. A one third scale of 3-storey double unit of TFB is tested
until its strength degradation. Then, the TFB is repaired and
retrofitted using additional shear wall, steel angle and CFRP sheet.
The crack patterns, lateral strength, stiffness, ductility and equivalent
viscous damping (EVD) were analyzed and compared before and
after repair and retrofit. The result indicates that the lateral strength
increases by 22% in pushing and 27% in pulling direction. Moreover,
the stiffness and ductility obtained before and after retrofit increase
tremendously by 87.87% and 39.66%, respectively. Meanwhile, the
energy absorption measured by equivalent viscous damping obtained
after retrofit increase by 12.34% in pulling direction. It can be
concluded that the proposed retrofit method is capable to increase the
lateral strength capacity, stiffness and energy absorption of double
unit TFB.