Abstract: In this preliminary work, locally available husk of Cajanus cajan (commonly known in India as Tur or Arhar), a bio-waste, has been used in its physically treated and chemically activated form for the removal of binary Cu (II) and Zn(II) ions from the real waste water obtained from an electroplating industry in Bangalore, Karnataka, India and from laboratory prepared binary solutions having almost similar composition of the metal ions, for comparison. The real wastewater after filtration and dilution for five times was used for biosorption studies at the normal pH of the solutions at room temperature. Langmuir's binary model was used to calculate the metal uptake capacities of the biosorbents. It was observed that Cu(II) is more competitive than Zn(II) in biosorption. In individual metal biosorption, Cu(II) uptake was found to be more than that of the Zn(II) and a similar trend was observed in the binary metal biosorption from real wastewater and laboratory prepared solutions. FTIR analysis was carried out to identify the functional groups in the industrial wastewater and EDAX for the elemental analysis of the biosorbents after experiments.
Abstract: The computational fluid dynamics (CFD) study of
stirred tank with the air-water interface are carried out in the presence
of different types of the impeller and with or without baffles. A
multiple reference frame (MRF) approach with the volume of fluid
(VOF) method is used to capture the air-water interface. The RANS
(Reynolds Averaged Navier-Stokes) equations with k-ε turbulence
model are solved to predict the flow behavior of water and air phase
which are treated as a different phases. The predicted results have
shown that the VOF method is able to capture the interface in the
unbaffled tank. While, the VOF method is showing an unfeasible
results in the baffled tank with high rotational impeller speed. For
continuous stirred tank, the air-water interface is disturbed by the
inflow and the level of water is also increased with time.
Abstract: A computational fluid dynamics simulation is done for
non-Newtonian fluid in a baffled stirred tank. The CMC solution is
taken as non-Newtonian shear thinning fluid for simulation. The
Reynolds Average Navier Stocks equation with steady state multi
reference frame approach is used to simulate flow in the stirred tank.
The turbulent flow field is modelled using realizable k-ε turbulence
model. The simulated velocity profiles of Rushton turbine is
validated with literature data. Then, the simulated flow field of CD-6
impeller is compared with the Rushton turbine. The flow field
generated by CD-6 impeller is less in magnitude than the Rushton
turbine. The impeller global parameter, power number and flow
number, and entropy generation due to viscous dissipation rate is also
reported.