Abstract: Bone properties and response behavior after static or
dynamic activation (loading) are still interesting topics in many fields
of the science especially in the biomechanical problems such as bone
loss of astronauts in space, osteoporosis, bone remodeling after
fracture or remodeling after surgery (endoprosthesis and implants)
and in osteointegration. This contribution deals with the relation
between physiological, demineralized and deproteinized state of the
turkey long bone – tibia. Three methods for comparison were used: 1)
densitometry, 2) three point bending and 3) frequency analysis. The
main goal of this work was to describe the decrease of the protein
(collagen) or mineral of the bone with relation to the fracture in three
point bending. The comparison is linked to the problem of different
bone mechanical behavior in physiological and osteoporotic state.
Abstract: The global solved problem is the calculation of the
parameters of ceramic material from a set of destruction tests of
ceramic heads of total hip joint endoprosthesis. The standard way of
calculation of the material parameters consists in carrying out a set of
3 or 4 point bending tests of specimens cut out from parts of the
ceramic material to be analysed. In case of ceramic heads, it is not
possible to cut out specimens of required dimensions because the
heads are too small (if the cut out specimens were smaller than the
normalised ones, the material parameters derived from them would
exhibit higher strength values than those which the given ceramic
material really has). A special destruction device for heads
destruction was designed and the solved local problem is the
modification of this destructive device based on the analysis of
tensile stress in the head for two different values of the depth of the
conical hole in the head. The goal of device modification is a shift of
the location with extreme value of σ1max from the region of head’s
hole bottom to its opening. This modification will increase the
credibility of the obtained material properties of bioceramics, which
will be determined from a set of head destructions using the Weibull
weakest link theory.
Abstract: The paper deals with calculation of the parameters of
ceramic material from a set of destruction tests of ceramic heads of
total hip joint endoprosthesis. The standard way of calculation of the
material parameters consists in carrying out a set of 3 or 4 point
bending tests of specimens cut out from parts of the ceramic material
to be analysed. In case of ceramic heads, it is not possible to cut out
specimens of required dimensions because the heads are too small (if
the cut out specimens were smaller than the normalised ones, the
material parameters derived from them would exhibit higher strength
values than those which the given ceramic material really has). On
that score, a special testing jig was made, in which 40 heads were
destructed. From the measured values of circumferential strains of the
head-s external spherical surface under destruction, the state of stress
in the head under destruction was established using the final elements
method (FEM). From the values obtained, the sought for parameters
of the ceramic material were calculated using Weibull-s weakest-link
theory.