Abstract: In this paper the authors propose a flexible electronic solution, to improve the energetic efficiency of a thermo plant. This is achieved by replacing the mechanical gear box, placed traditionally between a gas turbine and a synchronous generator; by a power electronic converter. After reminding problematic of gear boxes and interest of a proposed electronic solution in high power plants, the authors describe a new control strategy for an indirect frequency converter, which is characterized by its high efficiency due to the use of SWM: Square Wave Modulation. The main advantage of this mode is the quasi absence of switching losses. A control method is also proposed to resolve some problems incurred by using square wave modulation, in particular to reduce the harmonics distortion of the output inverter voltage and current. Simulation examples as well as experimental results are included.
Abstract: Adjacent Hall microsensors, comprising a silicon
substrate and four contacts, providing simultaneously two supply inputs and two differential outputs, are characterized. The voltage
related sensitivity is in the order of 0.11T-1, and a cancellation method for offset compensation is used, achieving residual offset in
the micro scale which is also compared to a single Hall plate.
Abstract: Preliminary studies on Kuwait high voltage
transmission system show significant increase in the short circuit
level at some of the grid substations and some generating stations.
This increase results from the growth in the power transmission
systems in size and complexity. New generating stations are expected
to be added to the system within the next few years. This paper
describes the study analysis performed to evaluate the available and
potential solutions to control SC levels in Kuwait power system. It
also presents a modified planning of the transmission network in
order to fulfill this task.
Abstract: This paper presents the mathematical model and
control strategy on DQ frame of shunt active power filter. The
structure of the shunt active power filter is the voltage source inverter
(VSI). The pulse width modulation (PWM) with PI controller is used
in the paper. The concept of DQ frame to apply with the shunt active
power filter is described. Moreover, the detail of the PI controller
design for two current loops and one voltage loop are fully explained.
The DQ axis with Fourier (DQF) method is applied to calculate the
reference currents on DQ frame. The simulation results show that the
control strategy and the design method presented in the paper can
provide the good performance of the shunt active power filter.
Moreover, the %THD of the source currents after compensation can
follow the IEEE Std.519-1992.
Abstract: Distributed Power generation has gained a lot of
attention in recent times due to constraints associated with
conventional power generation and new advancements in DG
technologies .The need to operate the power system economically
and with optimum levels of reliability has further led to an increase
in interest in Distributed Generation. However it is important to place
Distributed Generator on an optimum location so that the purpose of
loss minimization and voltage regulation is dully served on the
feeder. This paper investigates the impact of DG units installation on
electric losses, reliability and voltage profile of distribution networks.
In this paper, our aim would be to find optimal distributed
generation allocation for loss reduction subjected to constraint of
voltage regulation in distribution network. The system is further
analyzed for increased levels of Reliability. Distributed Generator
offers the additional advantage of increase in reliability levels as
suggested by the improvements in various reliability indices such as
SAIDI, CAIDI and AENS. Comparative studies are performed and
related results are addressed. An analytical technique is used in order
to find the optimal location of Distributed Generator. The suggested
technique is programmed under MATLAB software. The results
clearly indicate that DG can reduce the electrical line loss while
simultaneously improving the reliability of the system.
Abstract: To maximise furnace production it-s necessary to
optimise furnace control, with the objectives of achieving maximum
power input into the melting process, minimum network distortion
and power-off time, without compromise on quality and safety. This
can be achieved with on the one hand by an appropriate electrode
control and on the other hand by a minimum of AC transformer
switching.
Electrical arc is a stochastic process; witch is the principal cause
of power quality problems, including voltages dips, harmonic
distortion, unbalance loads and flicker. So it is difficult to make an
appropriate model for an Electrical Arc Furnace (EAF). The factors
that effect EAF operation are the melting or refining materials,
melting stage, electrode position (arc length), electrode arm control
and short circuit power of the feeder. So arc voltages, current and
power are defined as a nonlinear function of the arc length. In this
article we propose our own empirical function of the EAF and model,
for the mean stages of the melting process, thanks to the
measurements in the steel factory.
Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.
Abstract: This paper details few mechanical modeling and
design issues of RF MEMS switches. We concentrate on an
electrostatically actuated broad side series switch; surface
micromachined with a crab leg membrane. The same results are
extended to any complex structure. With available experimental data
and fabrication results, we present the variation in dynamic
performance and compliance of the switch with reference to few
design issues, which we find are critical in deciding the dynamic
behavior of the switch, without compromise on the RF
characteristics. The optimization of pull in voltage, transient time and
resonant frequency with regard to these critical design parameters are
also presented.
Abstract: A direct downconversion receiver implemented in 0.13 μm 1P8M process is presented. The circuit is formed by a single-end LNA, an active balun for conversion into balanced mode, a quadrature double-balanced passive switch mixer and a quadrature voltage-controlled oscillator. The receiver operates in the 2.4 GHz ISM band and complies with IEEE 802.15.4 (ZigBee) specifications. The circuit exhibits a very low noise figure of only 2.27 dB and dissipates only 14.6 mW with a 1.2 V supply voltage and is hence suitable for low-power applications.
Abstract: This paper presents the elastic buckling of
homogeneous beams with a pair of piezoelectric layers surface
bonded on both sides of the beams. The displacement field of beam is
assumed based on the Engesser-Timoshenko beam theory.
Applying the Hamilton's principle, the equilibrium equation is
established. The influences of applied voltage, dimensionless
geometrical parameter and piezoelectric thickness on the critical
buckling load of beam are presented. To investigate the accuracy of
the present analysis, a compression study is carried out with a known
data.
Abstract: The proper selection of the AC-side passive filter
interconnecting the voltage source converter to the power supply is
essential to obtain satisfactory performances of an active power filter
system. The use of the LCL-type filter has the advantage of
eliminating the high frequency switching harmonics in the current
injected into the power supply. This paper is mainly focused on
analyzing the influence of the interface filter parameters on the active
filtering performances. Some design aspects are pointed out. Thus,
the design of the AC interface filter starts from transfer functions by
imposing the filter performance which refers to the significant current
attenuation of the switching harmonics without affecting the
harmonics to be compensated. A Matlab/Simulink model of the entire
active filtering system including a concrete nonlinear load has been
developed to examine the system performances. It is shown that a
gamma LC filter could accomplish the attenuation requirement of the
current provided by converter. Moreover, the existence of an optimal
value of the grid-side inductance which minimizes the total harmonic
distortion factor of the power supply current is pointed out.
Nevertheless, a small converter-side inductance and a damping
resistance in series with the filter capacitance are absolutely needed
in order to keep the ripple and oscillations of the current at the
converter side within acceptable limits. The effect of change in the
LCL-filter parameters is evaluated. It is concluded that good active
filtering performances can be achieved with small values of the
capacitance and converter-side inductance.
Abstract: This article discusses the questions concerning of creating small packet networks for energy companies with application of high voltage power line carrier equipment (PLC) with functionality of IP traffic transmission. The main idea is to create converged PLC links between substations and dispatching centers where packet data and voice are transmitted in one data flow. The article contents description of basic conception of the network, evaluation of voice traffic transmission parameters, and discussion of header compression techniques in relation to PLC links. The results of exploration show us, that convergent packet PLC links can be very useful in the construction of small packet networks between substations in remote locations, such as deposits or low populated areas.
Abstract: Today-s Voltage Regulator Modules (VRMs) face increasing design challenges as the number of transistors in microprocessors increases per Moore-s Law. These challenges have recently become even more demanding as microprocessors operate at sub voltage range at significantly high current. This paper presents a new multiphase topology with cell configuration for improved performance in low voltage and high current applications. A lab scale hardware prototype of the new topology was design and constructed. Laboratory tests were performed on the proposed converter and compared with a commercially available VRM. Results from the proposed topology exhibit improved performance compared to the commercially available counterpart.
Abstract: This paper presents a novel methodology for Maximum Power Point Tracking (MPPT) of a grid-connected 20 kW Photovoltaic (PV) system using neuro-fuzzy network. The proposed method predicts the reference PV voltage guarantying optimal power transfer between the PV generator and the main utility grid. The neuro-fuzzy network is composed of a fuzzy rule-based classifier and three Radial Basis Function Neural Networks (RBFNN). Inputs of the network (irradiance and temperature) are classified before they are fed into the appropriated RBFNN for either training or estimation process while the output is the reference voltage. The main advantage of the proposed methodology, comparing to a conventional single neural network-based approach, is the distinct generalization ability regarding to the nonlinear and dynamic behavior of a PV generator. In fact, the neuro-fuzzy network is a neural network based multi-model machine learning that defines a set of local models emulating the complex and non-linear behavior of a PV generator under a wide range of operating conditions. Simulation results under several rapid irradiance variations proved that the proposed MPPT method fulfilled the highest efficiency comparing to a conventional single neural network.
Abstract: High performance Resistive Random Access Memory
(RRAM) based on HfOx has been prepared and its temperature
instability has been investigated in this work. With increasing
temperature, it is found that: leakage current at high resistance state
increases, which can be explained by the higher density of traps
inside dielectrics (related to trap-assistant tunneling), leading to a
smaller On/Off ratio; set and reset voltages decrease, which may be
attributed to the higher oxygen ion mobility, in addition to the
reduced potential barrier to create / recover oxygen ions (or oxygen
vacancies); temperature impact on the RRAM retention degradation
is more serious than electrical bias.
Abstract: An on-line condition monitoring method for transmission line is proposed using electrical circuit theory and IT technology in this paper. It is reasonable that the circuit parameters such as resistance (R), inductance (L), conductance (g) and capacitance (C) of a transmission line expose the electrical conditions and physical state of the line. Those parameters can be calculated from the linear equation composed of voltages and currents measured by synchro-phasor measurement technique at both end of the line. A set of linear voltage drop equations containing four terminal constants (A, B ,C ,D ) are mathematical models of the transmission line circuits. At least two sets of those linear equations are established from different operation condition of the line, they may mathematically yield those circuit parameters of the line. The conditions of line connectivity including state of connecting parts or contacting parts of the switching device may be monitored by resistance variations during operation. The insulation conditions of the line can be monitored by conductance (g) and capacitance(C) measurements. Together with other condition monitoring devices such as partial discharge, sensors and visual sensing device etc.,they may give useful information to monitor out any incipient symptoms of faults. The prototype of hardware system has been developed and tested through laboratory level simulated transmission lines. The test has shown enough evident to put the proposed method to practical uses.
Abstract: This paper presents the optimal controller design of
the generator control unit in the aircraft power system. The adaptive
tabu search technique is applied to tune the controller parameters
until the best terminal output voltage of generator is achieved. The
output response from the system with the controllers designed by the
proposed technique is compared with those from the conventional
method. The transient simulations using the commercial software
package show that the controllers designed from the adaptive tabu
search algorithm can provide the better output performance compared
with the result from the classical method. The proposed design
technique is very flexible and useful for electrical aircraft engineers.
Abstract: In this paper, genetic algorithm (GA) opmization technique is applied to design Flexible AC Transmission System (FACTS)-based damping controllers. Two types of controller structures, namely a proportional-integral (PI) and a lead-lag (LL) are considered. The design problem of the proposed controllers is formulated as an optimization problem and GA is employed to search for optimal controller parameters. By minimizing the time-domain based objective function, in which the deviation in the oscillatory rotor speed of the generator is involved; stability performance of the system is improved. The proposed controllers are tested on a weakly connected power system subjected to different disturbances. The non-linear simulation results are presented to show the effectiveness of the proposed controller and their ability to provide efficient damping of low frequency oscillations. It is also observed that the proposed SSSC-based controllers improve greatly the voltage profile of the system under severe disturbances. Further, the dynamic performances of both the PI and LL structured FACTS-controller are analyzed at different loading conditions and under various disturbance condition as well as under unbalanced fault conditions..
Abstract: In this paper, Fabless Prototyping Methodology is
introduced for the design and analysis of MEMS devices.
Conventionally Finite Element Analysis (FEA) is performed before
system level simulation. In our proposed methodology, system level
simulation is performed earlier than FEA as it is computationally less
extensive and low cost. System level simulations are based on
equivalent behavioral models of MEMS device. Electrostatic
actuation based MEMS Microgripper is chosen as case study to
implement this methodology. This paper addresses the behavioral
model development and simulation of actuator part of an
electrostatically actuated Microgripper. Simulation results show that
the actuator part of Microgripper works efficiently for a voltage range
of 0-45V with the corresponding jaw displacement of 0-4.5425μm.
With some minor changes in design, this range can be enhanced to
15μm at 85V.
Abstract: Modern Society is strongly dependent on a reliable
power supply. The availability of cheap and reliable supply of
electrical energy is an indicator of societal welfare. Uninterrupted
reliable operation of a modern power system depends to a great
extent on reliable and satisfactory performance of insulators under
different environmental conditions. This paper reports result of
natural pollution tests that have been done at sites around city of
Aligarh (India). Flashover voltage per insulation distance (FOVUID)
of porcelain disc insulator for different pH values, ESDD has been
recorded for proper correlation between electrical and chemical
parameters. The pH of the contaminants has been suggested to be an
effective pollution severity indicator and may be used as a diagnostic
parameter for proper maintenance of porcelain insulators.